Benjamin Hornberger
Research Subjects
Benjamin Hornberger has a total of 219 co-authors. Here are the top co-authors by number of shared publications:
- Chris Jacobsen
Applied Physics Program, Northwestern University, Evanston, IL 60208, USA
11 shared publications Michael Feser
Carl Zeiss X-ray Microscopy, Inc. (United States)
9 shared publications- Stefan Vogt
Argonne National Laboratory
7 shared publications M. Feser
Xradia Inc., Pleasanton, CA 94588, USA
5 shared publications- Philip John Withers
The University of Manchester
5 shared publications Andrei Tkachuk
Carl Zeiss X-ray Microscopy, Inc. 2 , 4385 Hopyard Road, Suite 100, Pleasanton, California 94588, USA
4 shared publications
Latest Publications
- 1 January 2020
- Published by Optica Publishing Group
- Vol. 84, EM1A.6
Recent Developments in Compact X-ray and Gamma-ray Sources based on Inverse Compton Scattering
We present recent developments in high-brightness, tunable, narrow-band photon sources. An upgrade to Lyncean's X-ray source increases flux and brightness ten-fold. Furthermore, we discuss the design of a novel narrow-bandwidth, high spectral density gamma-ray source.
- 1 January 2020
- Published by Optica Publishing Group
- Vol. 84, EM1A.6
Recent Developments in Compact X-ray and Gamma-ray Sources based on Inverse Compton Scattering
We present recent developments in high-brightness, tunable, narrow-band photon sources. An upgrade to Lyncean's X-ray source increases flux and brightness ten-fold. Furthermore, we discuss the design of a novel narrow-bandwidth, high spectral density gamma-ray source.
- Open Access
- 1 September 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 96, 400-411
Anisotropic crack propagation and deformation in dentin observed by four-dimensional X-ray nano-computed tomography
- 1 September 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 96, 400-411
Open AccessAnisotropic crack propagation and deformation in dentin observed by four-dimensional X-ray nano-computed tomography
- 1 March 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 86, 109-116
Time-lapse three-dimensional imaging of crack propagation in beetle cuticle
- 1 March 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 86, 109-116
Time-lapse three-dimensional imaging of crack propagation in beetle cuticle
- Open Access
- 10 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 120-121
Benchmarking of Machine Learning and Conventional Image Segmentation Techniques on 3D X-ray Microscopy Data
- 10 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 120-121
Open AccessBenchmarking of Machine Learning and Conventional Image Segmentation Techniques on 3D X-ray Microscopy Data
- Open Access
- 10 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 118-119
Iterative Reconstruction for Increased Imaging Throughput in Lab-based 3D XRM
- 10 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S2) , 118-119
Open AccessIterative Reconstruction for Increased Imaging Throughput in Lab-based 3D XRM
- Open Access
- 6 August 2018
- Published by AIP Publishing in Applied Physics Letters
- Vol. 113 (6) , 063105
Comparison of image properties in full-field phase X-ray microscopes based on grating interferometry and Zernike's phase contrast optics
A grating interferometer (GI) system has been installed in an X-ray microscope equipped with a Zernike phase contrast (ZPC) system and a Cu rotating anode X-ray source. The GI and ZPC systems are switchable, and their performances of phase information extraction have been compared. The GI system is based on a Lau interferometer consisting of an absorption grating and a π/2 phase grating, which extracts a magnified phase shift map of a sample via a phase-stepping measurement. The ZPC system generates a phase contrast image by using a phase plate and a corresponding condenser device. The ZPC system and the GI system are compared in terms of detectability of phase objects. By the Fourier analysis of images of a logarithmic ruler pattern, the spatial resolution was found to be identical between the two systems. Although the sensitivity depends on the sample size, the signal-to-noise ratio of polystyrene spheres with a few microns in diameter was used for sensitivity comparison, showing the superior sensitivity of the GI system to that of the ZPC system. The quantitativeness of the GI system with the phase-stepping measurement was also demonstrated over the ZPC system, which generates halo and shade-off artifacts. The GI system exhibits twin image artifacts that need to be resolved for practical applications of the technique.
- 6 August 2018
- Published by AIP Publishing in Applied Physics Letters
- Vol. 113 (6) , 063105
Open AccessComparison of image properties in full-field phase X-ray microscopes based on grating interferometry and Zernike's phase contrast optics
A grating interferometer (GI) system has been installed in an X-ray microscope equipped with a Zernike phase contrast (ZPC) system and a Cu rotating anode X-ray source. The GI and ZPC systems are switchable, and their performances of phase information extraction have been compared. The GI system is based on a Lau interferometer consisting of an absorption grating and a π/2 phase grating, which extracts a magnified phase shift map of a sample via a phase-stepping measurement. The ZPC system generates a phase contrast image by using a phase plate and a corresponding condenser device. The ZPC system and the GI system are compared in terms of detectability of phase objects. By the Fourier analysis of images of a logarithmic ruler pattern, the spatial resolution was found to be identical between the two systems. Although the sensitivity depends on the sample size, the signal-to-noise ratio of polystyrene spheres with a few microns in diameter was used for sensitivity comparison, showing the superior sensitivity of the GI system to that of the ZPC system. The quantitativeness of the GI system with the phase-stepping measurement was also demonstrated over the ZPC system, which generates halo and shade-off artifacts. The GI system exhibits twin image artifacts that need to be resolved for practical applications of the technique.
- 1 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S1) , 1010-1011
4D and In Situ X-ray Microscopy for Studying Damage Evolution in Materials Across Multiple Length Scales
- 1 August 2018
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 24 (S1) , 1010-1011
4D and In Situ X-ray Microscopy for Studying Damage Evolution in Materials Across Multiple Length Scales
- 17 April 2017
- Published by Wiley in Journal of Microscopy
- Vol. 267 (1) , 98-106
Time‐lapse lab‐based x‐ray nano‐CT study of corrosion damage
Summary: An experimental protocol (workflow) has been developed for time‐lapse x‐ray nanotomography (nano‐CT) imaging of environmentally driven morphological changes to materials. Two case studies are presented. First, the leaching of nanoparticle corrosion inhibitor pigment from a polymer coating was followed over 14 days, while in the second case the corrosion damage to an AA2099 aluminium alloy was imaged over 12 hours. The protocol includes several novel aspects relevant to nano‐CT with the use of a combination of x‐ray absorption and phase contrast data to provide enhanced morphological and composition information, and hence reveal the best information to provide new insights into the changes of different phases over time. For the pigmented polymer coating containing nominally strontium aluminium polyphosphate, the strontium‐rich components within the materials are observed to leach extensively whereas the aluminium‐rich components are more resistant to dissolution. In the case of AA2099 it is found that the initial grain boundary corrosion is driven by the presence of copper‐rich phases and is then followed by the corrosion of grains of specific orientation.
- 17 April 2017
- Published by Wiley in Journal of Microscopy
- Vol. 267 (1) , 98-106
Time‐lapse lab‐based x‐ray nano‐CT study of corrosion damage
Summary: An experimental protocol (workflow) has been developed for time‐lapse x‐ray nanotomography (nano‐CT) imaging of environmentally driven morphological changes to materials. Two case studies are presented. First, the leaching of nanoparticle corrosion inhibitor pigment from a polymer coating was followed over 14 days, while in the second case the corrosion damage to an AA2099 aluminium alloy was imaged over 12 hours. The protocol includes several novel aspects relevant to nano‐CT with the use of a combination of x‐ray absorption and phase contrast data to provide enhanced morphological and composition information, and hence reveal the best information to provide new insights into the changes of different phases over time. For the pigmented polymer coating containing nominally strontium aluminium polyphosphate, the strontium‐rich components within the materials are observed to leach extensively whereas the aluminium‐rich components are more resistant to dissolution. In the case of AA2099 it is found that the initial grain boundary corrosion is driven by the presence of copper‐rich phases and is then followed by the corrosion of grains of specific orientation.
- 11 August 2016
- Published by Springer Nature in Experimental Mechanics
- Vol. 56 (9) , 1585-1597
In Situ Laboratory-Based Transmission X-Ray Microscopy and Tomography of Material Deformation at the Nanoscale
- 11 August 2016
- Published by Springer Nature in Experimental Mechanics
- Vol. 56 (9) , 1585-1597
In Situ Laboratory-Based Transmission X-Ray Microscopy and Tomography of Material Deformation at the Nanoscale
- 28 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1696 (1) , 020028
2D/3D cryo x-ray fluorescence imaging at the bionanoprobe at the advanced photon source
Trace elements, particularly metals, play very important roles in biological systems. Synchrotron-based hard X-ray fluorescence microscopy offers the most suitable capabilities to quantitatively study trace metals in thick biological samples, such as whole cells and tissues. In this manuscript, we have demonstrated X-ray fluorescence imaging of frozen-hydrated whole cells using the recent developed Bionanoprobe (BNP). The BNP provides spatial resolution down to 30 nm and cryogenic capabilities. Frozen-hydrated biological cells have been directly examined on a sub-cellular level at liquid nitrogen temperatures with minimal sample preparation.
- 28 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1696 (1) , 020028
2D/3D cryo x-ray fluorescence imaging at the bionanoprobe at the advanced photon source
Trace elements, particularly metals, play very important roles in biological systems. Synchrotron-based hard X-ray fluorescence microscopy offers the most suitable capabilities to quantitatively study trace metals in thick biological samples, such as whole cells and tissues. In this manuscript, we have demonstrated X-ray fluorescence imaging of frozen-hydrated whole cells using the recent developed Bionanoprobe (BNP). The BNP provides spatial resolution down to 30 nm and cryogenic capabilities. Frozen-hydrated biological cells have been directly examined on a sub-cellular level at liquid nitrogen temperatures with minimal sample preparation.