Hui Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hui Li has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
Linbo Wang
Jiangsu Key Laboratory of Medical Optics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences
10 shared publicationsXiaohu Chen
School of Electronic Information Huzhou College Huzhou Zhejiang China
8 shared publicationsXin Jin
Jiangsu Key Laboratory of Medical Optics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences
8 shared publicationsYong Liang
Jiangsu Key Laboratory of Medical Optics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences
8 shared publicationsGang Wen
Jiangsu Key Laboratory of Medical Optics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences
7 shared publicationsSimin Li
College of Chemistry, Chemical Engineering, and Materials Science, Shandong Normal University
7 shared publications
Latest Publications
- 2 September 2026
- Published by Wiley in Laser & Photonics Reviews
Full‐Field‐of‐View Metalens Scanner Optical Module for High‐Speed Imaging Toward Miniaturized Two‐Photon Microscopy
Two‐photon microscopy is a widely used imaging technique in life sciences, offering deep‐tissue penetration and high signal‐to‐noise ratio. However, the performance of miniaturized two‐photon systems is often constrained by the bulky dimensions of conventional objectives, limited aberration correction, and a restricted field of view, which together hinder high‐quality imaging in freely behaving animals. Here, we design and experimentally validate a full‐field‐of‐view metalens scanner optical module based on a gallium nitride metasurface toward high‐speed miniaturized two‐photon microscopy. Guided by generalized Snell's law, the optimized phase profile of the full‐field‐of‐view metalens suppresses off‐axis aberrations and maintains well‐confined focusing over a 100 µm field of view. Transmission and reflection imaging experiments demonstrate that, when integrated with a piezoelectric fiber scanner, the metalens scanner optical module achieves an acquisition rate of 20 fps. The present study does not directly demonstrate two‐photon excitation, fluorescence imaging, or nonlinear optical sectioning, but rather establishes an optical foundation for the future integration of the metalens scanner module into a compact two‐photon fluorescence imaging system.
- 2 September 2026
- Published by Wiley in Laser & Photonics Reviews
Full‐Field‐of‐View Metalens Scanner Optical Module for High‐Speed Imaging Toward Miniaturized Two‐Photon Microscopy
Two‐photon microscopy is a widely used imaging technique in life sciences, offering deep‐tissue penetration and high signal‐to‐noise ratio. However, the performance of miniaturized two‐photon systems is often constrained by the bulky dimensions of conventional objectives, limited aberration correction, and a restricted field of view, which together hinder high‐quality imaging in freely behaving animals. Here, we design and experimentally validate a full‐field‐of‐view metalens scanner optical module based on a gallium nitride metasurface toward high‐speed miniaturized two‐photon microscopy. Guided by generalized Snell's law, the optimized phase profile of the full‐field‐of‐view metalens suppresses off‐axis aberrations and maintains well‐confined focusing over a 100 µm field of view. Transmission and reflection imaging experiments demonstrate that, when integrated with a piezoelectric fiber scanner, the metalens scanner optical module achieves an acquisition rate of 20 fps. The present study does not directly demonstrate two‐photon excitation, fluorescence imaging, or nonlinear optical sectioning, but rather establishes an optical foundation for the future integration of the metalens scanner module into a compact two‐photon fluorescence imaging system.
- Open Access
- 28 February 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 19 (02)
Traction force microscopy: Bridging cytology and mechanics through optics
Cells interact with the extracellular matrix and generate traction forces, which play fundamental roles in many cytological activities, such as migration and differentiation. The quantification of these traction forces is a prerequisite for understanding the interaction and regulation between force and functions, which can be accomplished by traction force microscopy (TFM). In TFM, the forces are determined by tracking the displacement of fiducial markers through optical microscopy. The type of fiducial marker, microscopy modality, and image processing algorithms are key factors determining the final resolution of TFM. This review summarizes efforts in three aspects to enhance the performance of TFM and discusses the challenges of further development, particularly from an optical view.
- 28 February 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 19 (02)
Open AccessTraction force microscopy: Bridging cytology and mechanics through optics
Cells interact with the extracellular matrix and generate traction forces, which play fundamental roles in many cytological activities, such as migration and differentiation. The quantification of these traction forces is a prerequisite for understanding the interaction and regulation between force and functions, which can be accomplished by traction force microscopy (TFM). In TFM, the forces are determined by tracking the displacement of fiducial markers through optical microscopy. The type of fiducial marker, microscopy modality, and image processing algorithms are key factors determining the final resolution of TFM. This review summarizes efforts in three aspects to enhance the performance of TFM and discusses the challenges of further development, particularly from an optical view.
- 2 June 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (7) , 2573-2583
Direct blood flow velocity measurements of zebrafish cerebral vessels with a dual-mode light-sheet microscope
Characterization of cerebral blood flow is critical to studying brain function and disorders. We report a method for directly measuring zebrafish cerebral blood flow velocity in 3D. A dual-mode light sheet microscopy combined with structured illumination was developed to image zebrafish 3D brain vasculature in structured illumination mode and to trace the blood cells in fast imaging mode at the same region. Evans blue (EB) was injected into the heart of zebrafish to visualize the vessels, while the blood cells appeared to be dark in the vessels. Our approach significantly improves imaging speed to 100 Hz. Algorithms were developed to trace the blood cells and match the flow velocity to vascular structures. The blood flow velocity in the cerebral microvessels at different depths was obtained for zebrafish up to 8 days post-fertilization (dpf). The flow velocity and flux in “Y” shaped and curved vessels were analyzed.
- 2 June 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (7) , 2573-2583
Direct blood flow velocity measurements of zebrafish cerebral vessels with a dual-mode light-sheet microscope
Characterization of cerebral blood flow is critical to studying brain function and disorders. We report a method for directly measuring zebrafish cerebral blood flow velocity in 3D. A dual-mode light sheet microscopy combined with structured illumination was developed to image zebrafish 3D brain vasculature in structured illumination mode and to trace the blood cells in fast imaging mode at the same region. Evans blue (EB) was injected into the heart of zebrafish to visualize the vessels, while the blood cells appeared to be dark in the vessels. Our approach significantly improves imaging speed to 100 Hz. Algorithms were developed to trace the blood cells and match the flow velocity to vascular structures. The blood flow velocity in the cerebral microvessels at different depths was obtained for zebrafish up to 8 days post-fertilization (dpf). The flow velocity and flux in “Y” shaped and curved vessels were analyzed.
- Open Access
- 29 October 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 18 (01)
Quantitative evaluation of intensity fidelity of super-resolution reconstruction for structured illumination microscopy
Super-resolution structured illumination microscopy (SR-SIM) relies heavily on post-processing reconstruction to obtain high-quality SR images from raw data. Although many SIM reconstruction algorithms have been developed to recover fine cellular structures with high fidelity even from the noisy data, whether the pixel intensities of reconstructed SR images are still proportional to the original fluorescence intensity has been less explored. The linearity between the intensity before and after reconstruction is defined as the intensity fidelity. Here, we proposed a method to evaluate the reconstructed SR image intensity fidelity at different spatial frequencies. With the proposed metric, we systematically investigated the impact of the key factors on the intensity fidelity in the standard Wiener-SIM reconstructions with simulated data, then evaluated the intensity fidelity of the SR images reconstructed by representative open-source packages. Our work provides a reference for SR-SIM image intensity fidelity improvement.
- 29 October 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 18 (01)
Open AccessQuantitative evaluation of intensity fidelity of super-resolution reconstruction for structured illumination microscopy
Super-resolution structured illumination microscopy (SR-SIM) relies heavily on post-processing reconstruction to obtain high-quality SR images from raw data. Although many SIM reconstruction algorithms have been developed to recover fine cellular structures with high fidelity even from the noisy data, whether the pixel intensities of reconstructed SR images are still proportional to the original fluorescence intensity has been less explored. The linearity between the intensity before and after reconstruction is defined as the intensity fidelity. Here, we proposed a method to evaluate the reconstructed SR image intensity fidelity at different spatial frequencies. With the proposed metric, we systematically investigated the impact of the key factors on the intensity fidelity in the standard Wiener-SIM reconstructions with simulated data, then evaluated the intensity fidelity of the SR images reconstructed by representative open-source packages. Our work provides a reference for SR-SIM image intensity fidelity improvement.
- Open Access
Flat-field super-resolution structured illumination microscopy with joint spatial-temporal light modulation
Super-resolution structured illumination microscope (SR-SIM) has been established as a powerful tool for visualizing subcellular dynamics and studying organelle interactions in live cells. However, the interfering Gaussian beams result in a limited and nonuniform field of view (FOV) which hinders its application for large whole-cell dynamics and pathological sample imaging. Here, we proposed a joint spatial-temporal light modulation (JSTLM) method to reshape the excitation light field into flat-field structured illumination without disturbing the interfering fringes. Our flat-field structured illumination microscopy (flat-field SIM) improves the uniformity across the whole FOV significantly, hence enabling SR image stitching. Skeleton dynamics and vesicle transportation in and between whole cells were visualized by flat-field SIM. With the stitching of multi-FOV flat-field SIM images, millimeter-sized SR images can be obtained which provides the possibility for cell heterogeneity studies and pathological diagnoses. The JSTLM method can be further incorporated with regions of interest to reduce unnecessary photodamage to live cells during multicolor imaging. Contributions Y.L. and X.H.C. conceived and designed the idea. Y.L., S.M.L., X.J., and G.W. built the SIM setup. Y.L. performed the data acquisitions. Y.L. and X.H.C. conducted the optical wave simulation. J.Z. prepared the cell samples. Y.T. and L.B.W. performed the image analyses. Y.L. prepared the illustrations. X.H.C. and J.G. supervised the project. Y.L. and H.L. wrote the manuscript.
Open AccessFlat-field super-resolution structured illumination microscopy with joint spatial-temporal light modulation
Super-resolution structured illumination microscope (SR-SIM) has been established as a powerful tool for visualizing subcellular dynamics and studying organelle interactions in live cells. However, the interfering Gaussian beams result in a limited and nonuniform field of view (FOV) which hinders its application for large whole-cell dynamics and pathological sample imaging. Here, we proposed a joint spatial-temporal light modulation (JSTLM) method to reshape the excitation light field into flat-field structured illumination without disturbing the interfering fringes. Our flat-field structured illumination microscopy (flat-field SIM) improves the uniformity across the whole FOV significantly, hence enabling SR image stitching. Skeleton dynamics and vesicle transportation in and between whole cells were visualized by flat-field SIM. With the stitching of multi-FOV flat-field SIM images, millimeter-sized SR images can be obtained which provides the possibility for cell heterogeneity studies and pathological diagnoses. The JSTLM method can be further incorporated with regions of interest to reduce unnecessary photodamage to live cells during multicolor imaging. Contributions Y.L. and X.H.C. conceived and designed the idea. Y.L., S.M.L., X.J., and G.W. built the SIM setup. Y.L. performed the data acquisitions. Y.L. and X.H.C. conducted the optical wave simulation. J.Z. prepared the cell samples. Y.T. and L.B.W. performed the image analyses. Y.L. prepared the illustrations. X.H.C. and J.G. supervised the project. Y.L. and H.L. wrote the manuscript.
- 20 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 35 (24) , 1407-1410
Single-Wavelength Focusing Metalens for Multichannel Two-Photon Microscopy
The miniatured two-photon microscope is promising for monitoring brain activities of free-behaving animals or in-situ endoscope diagnosis. Ultrathin and lightweight metalens presents a potential alternative to bulky refractive lenses for a miniaturized optical system. However, designing and fabricating achromatic metalens covering the near-infrared and visible light spectrum range is challenging. This paper proposes a metalens focusing at one wavelength while capable of multichannel microscopy due to the nonlinear properties of two-photon excitation. The metalens was designed solely to focus near-infrared excitation laser (1040 nm) using geometric phase regardless of the chromatic correction for visible emission light. Our method simplifies the design process, reduces manufacturing costs, and increases the focusing efficiency for the excitation light while maintaining a high transmittance for visible light. Using the metalens, two-photon biological imaging with three different labels was experimentally demonstrated with subcellular resolution.
- 20 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 35 (24) , 1407-1410
Single-Wavelength Focusing Metalens for Multichannel Two-Photon Microscopy
The miniatured two-photon microscope is promising for monitoring brain activities of free-behaving animals or in-situ endoscope diagnosis. Ultrathin and lightweight metalens presents a potential alternative to bulky refractive lenses for a miniaturized optical system. However, designing and fabricating achromatic metalens covering the near-infrared and visible light spectrum range is challenging. This paper proposes a metalens focusing at one wavelength while capable of multichannel microscopy due to the nonlinear properties of two-photon excitation. The metalens was designed solely to focus near-infrared excitation laser (1040 nm) using geometric phase regardless of the chromatic correction for visible emission light. Our method simplifies the design process, reduces manufacturing costs, and increases the focusing efficiency for the excitation light while maintaining a high transmittance for visible light. Using the metalens, two-photon biological imaging with three different labels was experimentally demonstrated with subcellular resolution.
- Open Access
- 15 June 2023
- Published by Springer Nature in PhotoniX
- Vol. 4 (1) , 1-18
Spectrum-optimized direct image reconstruction of super-resolution structured illumination microscopy
Super-resolution structured illumination microscopy (SR-SIM) has become a widely used nanoscopy technique for rapid, long-term, and multi-color imaging of live cells. Precise but troublesome determination of the illumination pattern parameters is a prerequisite for Wiener-deconvolution-based SR-SIM image reconstruction. Here, we present a direct reconstruction SIM algorithm (direct-SIM) with an initial spatial-domain reconstruction followed by frequency-domain spectrum optimization. Without any prior knowledge of illumination patterns and bypassing the artifact-sensitive Wiener deconvolution procedures, resolution-doubled SR images could be reconstructed by direct-SIM free of common artifacts, even for the raw images with large pattern variance in the field of view (FOV). Direct-SIM can be applied to previously difficult scenarios such as very sparse samples, periodic samples, very small FOV imaging, and stitched large FOV imaging.
- 15 June 2023
- Published by Springer Nature in PhotoniX
- Vol. 4 (1) , 1-18
Open AccessSpectrum-optimized direct image reconstruction of super-resolution structured illumination microscopy
Super-resolution structured illumination microscopy (SR-SIM) has become a widely used nanoscopy technique for rapid, long-term, and multi-color imaging of live cells. Precise but troublesome determination of the illumination pattern parameters is a prerequisite for Wiener-deconvolution-based SR-SIM image reconstruction. Here, we present a direct reconstruction SIM algorithm (direct-SIM) with an initial spatial-domain reconstruction followed by frequency-domain spectrum optimization. Without any prior knowledge of illumination patterns and bypassing the artifact-sensitive Wiener deconvolution procedures, resolution-doubled SR images could be reconstructed by direct-SIM free of common artifacts, even for the raw images with large pattern variance in the field of view (FOV). Direct-SIM can be applied to previously difficult scenarios such as very sparse samples, periodic samples, very small FOV imaging, and stitched large FOV imaging.
- 28 April 2023
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 15 (19) , 8854-8862
Computational hyperspectral devices based on quasi-random metasurface supercells
Computational hyperspectral devices that use artificial filters have shown promise as compact spectral devices. However, the current designs are restricted by limited types and geometric parameters of unit cells, resulting in a high cross-correlation between the transmission spectra. This limitation prevents the fulfillment of the requirement for compressed-sensing-based spectral reconstruction. To address this challenge, we proposed and simulated a novel design for computational hyperspectral devices based on quasi-random metasurface supercells. The size of the quasi-random metasurface supercell was extended above the wavelength, which enables the exploration of a larger variety of symmetrical supercell structures. Consequently, more quasi-random supercells with lower polarization sensitivity and their spectra with low cross-correlation were obtained. Devices for narrowband spectral reconstruction and broadband hyperspectral single-shot imaging were designed and fabricated. Combined with the genetic algorithm with compressed sensing, the narrowband spectral reconstruction device reconstructs the complex narrowband hyperspectral signal with 6 nm spectral resolution and ultralow errors. The broadband hyperspectral device reconstructs a broadband hyperspectral image (λ/λ ∼ 0.001) with a high average signal fidelity of 92%. This device has the potential to be integrated into a complementary metal–oxide–semiconductor (CMOS) chip for single-shot imaging.
- 28 April 2023
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 15 (19) , 8854-8862
Computational hyperspectral devices based on quasi-random metasurface supercells
Computational hyperspectral devices that use artificial filters have shown promise as compact spectral devices. However, the current designs are restricted by limited types and geometric parameters of unit cells, resulting in a high cross-correlation between the transmission spectra. This limitation prevents the fulfillment of the requirement for compressed-sensing-based spectral reconstruction. To address this challenge, we proposed and simulated a novel design for computational hyperspectral devices based on quasi-random metasurface supercells. The size of the quasi-random metasurface supercell was extended above the wavelength, which enables the exploration of a larger variety of symmetrical supercell structures. Consequently, more quasi-random supercells with lower polarization sensitivity and their spectra with low cross-correlation were obtained. Devices for narrowband spectral reconstruction and broadband hyperspectral single-shot imaging were designed and fabricated. Combined with the genetic algorithm with compressed sensing, the narrowband spectral reconstruction device reconstructs the complex narrowband hyperspectral signal with 6 nm spectral resolution and ultralow errors. The broadband hyperspectral device reconstructs a broadband hyperspectral image (λ/λ ∼ 0.001) with a high average signal fidelity of 92%. This device has the potential to be integrated into a complementary metal–oxide–semiconductor (CMOS) chip for single-shot imaging.
- 31 January 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (2) , 971-984
Three-dimensional cerebral vasculature topological parameter extraction of transgenic zebrafish embryos with a filling-enhancement deep learning network
Quantitative analysis of zebrafish cerebral vasculature is essential for the study of vascular development and disease. We developed a method to accurately extract the cerebral vasculature topological parameters of transgenic zebrafish embryos. The intermittent and hollow vascular structures of transgenic zebrafish embryos, obtained from 3D light-sheet imaging, were transformed into continuous solid structures with a filling-enhancement deep learning network. The enhancement enables the extraction of 8 vascular topological parameters accurately. Quantitation of the zebrafish cerebral vasculature vessels with the topological parameters show a developmental pattern transition from 2.5 to 5.5 dpf.
- 31 January 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (2) , 971-984
Three-dimensional cerebral vasculature topological parameter extraction of transgenic zebrafish embryos with a filling-enhancement deep learning network
Quantitative analysis of zebrafish cerebral vasculature is essential for the study of vascular development and disease. We developed a method to accurately extract the cerebral vasculature topological parameters of transgenic zebrafish embryos. The intermittent and hollow vascular structures of transgenic zebrafish embryos, obtained from 3D light-sheet imaging, were transformed into continuous solid structures with a filling-enhancement deep learning network. The enhancement enables the extraction of 8 vascular topological parameters accurately. Quantitation of the zebrafish cerebral vasculature vessels with the topological parameters show a developmental pattern transition from 2.5 to 5.5 dpf.
- Open Access
- 12 January 2023
- Published by Springer Nature in Research Square
Spectrum-optimized direct image reconstruction of super-resolution structured illumination microscopy
Super-resolution structured illumination microscopy (SR-SIM) has become a widely used nanoscopy technique for rapid, long-term, and multi-color imaging of live cells. Precise but troublesome determination of the illumination pattern parameters is a prerequisite for Wiener-deconvolution-based SR-SIM image reconstruction. Here, we present a direct reconstruction SIM algorithm (direct-SIM) with an initial spatial-domain reconstruction followed by frequency-domain spectrum optimization. Without any prior knowledge of illumination patterns and bypassing the artifact-sensitive Wiener deconvolution procedures, resolution-doubled SR images could be reconstructed by direct-SIM free of common artifacts, even for the raw images with large pattern variance in the field of view (FOV). Direct-SIM can be applied to previously difficult scenarios such as very sparse samples, periodic samples, very small FOV imaging, and stitched large FOV imaging.
- 12 January 2023
- Published by Springer Nature in Research Square
Open AccessSpectrum-optimized direct image reconstruction of super-resolution structured illumination microscopy
Super-resolution structured illumination microscopy (SR-SIM) has become a widely used nanoscopy technique for rapid, long-term, and multi-color imaging of live cells. Precise but troublesome determination of the illumination pattern parameters is a prerequisite for Wiener-deconvolution-based SR-SIM image reconstruction. Here, we present a direct reconstruction SIM algorithm (direct-SIM) with an initial spatial-domain reconstruction followed by frequency-domain spectrum optimization. Without any prior knowledge of illumination patterns and bypassing the artifact-sensitive Wiener deconvolution procedures, resolution-doubled SR images could be reconstructed by direct-SIM free of common artifacts, even for the raw images with large pattern variance in the field of view (FOV). Direct-SIM can be applied to previously difficult scenarios such as very sparse samples, periodic samples, very small FOV imaging, and stitched large FOV imaging.