Jeremy A. Barry
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jeremy A. Barry has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- David Charles Muddiman
Biological Imaging Laboratory for Disease and Exposure Research (BILDER), Department of Chemistry, North Carolina State University, Raleigh, USA
10 shared publications Guillaume Robichaud
W.M. Keck FT-ICR Mass Spectrometry Laboratory, Department of Chemistry, North Carolina State University, Raleigh, North Carolina
8 shared publications- Mark Reid Groseclose
Bioimaging, GSK, Collegeville, USA
3 shared publications Stephen Castellino
Bioimaging, GlaxoSmithKline, Collegeville, PA 19426, USA
3 shared publicationsKenneth P. Garrard
Precision Engineering Center, North Carolina State University, 27695, Raleigh, NC, USA
2 shared publicationsKristin H. Cochran
W.M. Keck Fourier Transform Mass Spectrometry Laboratory, Department of Chemistry, North Carolina State University, Raleigh, NC, 27695, USA
2 shared publications
Latest Publications
- Open Access
- 28 June 2019
- Published by Taylor & Francis in Bioanalysis
- Vol. 11 (11) , 1099-1116
Quantification and Assessment of Detection Capability in Imaging Mass Spectrometry Using a Revised Mimetic Tissue Model
Aim: A revised method of preparing the mimetic tissue model for quantitative imaging mass spectrometry (IMS) is evaluated. Concepts of assessing detection capability are adapted from other imaging ...
- 28 June 2019
- Published by Taylor & Francis in Bioanalysis
- Vol. 11 (11) , 1099-1116
Open AccessQuantification and Assessment of Detection Capability in Imaging Mass Spectrometry Using a Revised Mimetic Tissue Model
Aim: A revised method of preparing the mimetic tissue model for quantitative imaging mass spectrometry (IMS) is evaluated. Concepts of assessing detection capability are adapted from other imaging ...
- Open Access
- 2 April 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (9) , 6266-6274
Multicenter Validation Study of Quantitative Imaging Mass Spectrometry
The aim of this study was to assess potential sources of variability in quantitative imaging mass spectrometry (IMS) across multiple sites, analysts, and instruments. A sample from rat liver perfused with clozapine was distributed to three sites for analysis by three analysts using a pre-defined protocol to standardize the sample preparation, acquisition, and analysis parameters. In addition, two commonly used approaches to IMS quantification, the mimetic tissue model and dilution series, were used to quantify clozapine and its major metabolite norclozapine in isolated perfused rat liver. The quantification was evaluated in terms of precision and accuracy with comparison to liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The results of this study showed that across three analysts with six replicates each, both quantitative IMS methods achieved relative standard deviations in the low teens and accuracies of around 80% compared to LC-MS/MS quantification of adjacent tissue sections. The utility of a homogenously coated stable-isotopically labeled standard (SIL) for normalization was appraised in terms of its potential to improve precision and accuracy of quantification as well as qualitatively reduce variability in the sample tissue. SIL normalization had a larger influence on the dilution series where the use of the internal standard was necessary to achieve accuracy and precision comparable to the non-normalized mimetic tissue model data. Normalization to the internal standard appeared most effective when the intensity ratio of the analyte to internal standard was approximately one and thus precludes this method as a universal normalization approach for all ions in the acquisition.
- 2 April 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (9) , 6266-6274
Open AccessMulticenter Validation Study of Quantitative Imaging Mass Spectrometry
The aim of this study was to assess potential sources of variability in quantitative imaging mass spectrometry (IMS) across multiple sites, analysts, and instruments. A sample from rat liver perfused with clozapine was distributed to three sites for analysis by three analysts using a pre-defined protocol to standardize the sample preparation, acquisition, and analysis parameters. In addition, two commonly used approaches to IMS quantification, the mimetic tissue model and dilution series, were used to quantify clozapine and its major metabolite norclozapine in isolated perfused rat liver. The quantification was evaluated in terms of precision and accuracy with comparison to liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The results of this study showed that across three analysts with six replicates each, both quantitative IMS methods achieved relative standard deviations in the low teens and accuracies of around 80% compared to LC-MS/MS quantification of adjacent tissue sections. The utility of a homogenously coated stable-isotopically labeled standard (SIL) for normalization was appraised in terms of its potential to improve precision and accuracy of quantification as well as qualitatively reduce variability in the sample tissue. SIL normalization had a larger influence on the dilution series where the use of the internal standard was necessary to achieve accuracy and precision comparable to the non-normalized mimetic tissue model data. Normalization to the internal standard appeared most effective when the intensity ratio of the analyte to internal standard was approximately one and thus precludes this method as a universal normalization approach for all ions in the acquisition.
- Open Access
- 24 August 2018
- Published by Springer Nature in Protocol Exchange
Revised Preparation of a Mimetic Tissue Model for Quantitative Imaging Mass Spectrometry
- 24 August 2018
- Published by Springer Nature in Protocol Exchange
Open AccessRevised Preparation of a Mimetic Tissue Model for Quantitative Imaging Mass Spectrometry
- 1 February 2015
- Published by Elsevier in International Journal of Mass Spectrometry
- Vol. 377, 448-455
Assessing drug and metabolite detection in liver tissue by UV-MALDI and IR-MALDESI mass spectrometry imaging coupled to FT-ICR MS
- 1 February 2015
- Published by Elsevier in International Journal of Mass Spectrometry
- Vol. 377, 448-455
Assessing drug and metabolite detection in liver tissue by UV-MALDI and IR-MALDESI mass spectrometry imaging coupled to FT-ICR MS
- 1 August 2014
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (3) , 813-820
Analysis of trace fibers by IR-MALDESI imaging coupled with high resolving power MS
Trace evidence is a significant portion of forensic cases. Textile fibers are a common form of trace evidence that are gaining importance in criminal cases. Currently, qualitative techniques that do not yield structural information are primarily used for fiber analysis, but mass spectrometry is gaining an increasing role in this field. Mass spectrometry yields more quantitative structural information about the dye and polymer that can be used for more conclusive comparisons. Matrix-assisted laser desorption electrospray ionization (MALDESI) is a hybrid ambient ionization source being investigated for use in mass spectrometric fiber analysis. In this manuscript, IR-MALDESI was used as a source for mass spectrometry imaging (MSI) of a dyed nylon fiber cluster and single fiber. Information about the fiber polymer as well as the dye were obtained from a single fiber which was on the order of 10 μm in diameter. These experiments were performed directly from the surface of a tape lift of the fiber with a background of extraneous fibers. IR-MALDESI Imaging of Fibers on Tape-Lift
- 1 August 2014
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (3) , 813-820
Analysis of trace fibers by IR-MALDESI imaging coupled with high resolving power MS
Trace evidence is a significant portion of forensic cases. Textile fibers are a common form of trace evidence that are gaining importance in criminal cases. Currently, qualitative techniques that do not yield structural information are primarily used for fiber analysis, but mass spectrometry is gaining an increasing role in this field. Mass spectrometry yields more quantitative structural information about the dye and polymer that can be used for more conclusive comparisons. Matrix-assisted laser desorption electrospray ionization (MALDESI) is a hybrid ambient ionization source being investigated for use in mass spectrometric fiber analysis. In this manuscript, IR-MALDESI was used as a source for mass spectrometry imaging (MSI) of a dyed nylon fiber cluster and single fiber. Information about the fiber polymer as well as the dye were obtained from a single fiber which was on the order of 10 μm in diameter. These experiments were performed directly from the surface of a tape lift of the fiber with a background of extraneous fibers. IR-MALDESI Imaging of Fibers on Tape-Lift
- 18 April 2014
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 25 (12) , 2038-2047
Mapping Antiretroviral Drugs in Tissue by IR-MALDESI MSI Coupled to the Q Exactive and Comparison with LC-MS/MS SRM Assay
This work describes the coupling of the IR-MALDESI imaging source with the Q Exactive mass spectrometer. IR-MALDESI MSI was used to elucidate the spatial distribution of several HIV drugs in cervical tissues that had been incubated in either a low or high concentration. Serial sections of those analyzed by IR-MALDESI MSI were homogenized and analyzed by LC-MS/MS to quantify the amount of each drug present in the tissue. By comparing the two techniques, an agreement between the average intensities from the imaging experiment and the absolute quantities for each drug was observed. This correlation between these two techniques serves as a prerequisite to quantitative IR-MALDESI MSI. In addition, a targeted MS2 imaging experiment was also conducted to demonstrate the capabilities of the Q Exactive and to highlight the added selectivity that can be obtained with SRM or MRM imaging experiments.
- 18 April 2014
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 25 (12) , 2038-2047
Mapping Antiretroviral Drugs in Tissue by IR-MALDESI MSI Coupled to the Q Exactive and Comparison with LC-MS/MS SRM Assay
This work describes the coupling of the IR-MALDESI imaging source with the Q Exactive mass spectrometer. IR-MALDESI MSI was used to elucidate the spatial distribution of several HIV drugs in cervical tissues that had been incubated in either a low or high concentration. Serial sections of those analyzed by IR-MALDESI MSI were homogenized and analyzed by LC-MS/MS to quantify the amount of each drug present in the tissue. By comparing the two techniques, an agreement between the average intensities from the imaging experiment and the absolute quantities for each drug was observed. This correlation between these two techniques serves as a prerequisite to quantitative IR-MALDESI MSI. In addition, a targeted MS2 imaging experiment was also conducted to demonstrate the capabilities of the Q Exactive and to highlight the added selectivity that can be obtained with SRM or MRM imaging experiments.
- 3 January 2014
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 25 (3) , 319-328
IR-MALDESI Mass Spectrometry Imaging of Biological Tissue Sections Using Ice as a Matrix
Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) mass spectrometry imaging of biological tissue sections using a layer of deposited ice as an energy-absorbing matrix was investigated. Dynamics of plume ablation were first explored using a nanosecond exposure shadowgraphy system designed to simultaneously collect pictures of the plume with a camera and collect the Fourier transform ion cyclotron resonance FT-ICR mass spectrum corresponding to that same ablation event. Ablation of fresh tissue analyzed with and without using ice as a matrix were compared using this technique. Effect of spot-to-spot distance, number of laser shots per pixel, and tissue condition (matrix) on ion abundance were also investigated for 50 μm-thick tissue sections. Finally, the statistical method called design of experiments was used to compare source parameters and determine the optimal conditions for IR-MALDESI of tissue sections using deposited ice as a matrix. With a better understanding of the fundamentals of ablation dynamics and a systematic approach to explore the experimental space, it was possible to improve ion abundance by nearly one order of magnitude.
- 3 January 2014
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 25 (3) , 319-328
IR-MALDESI Mass Spectrometry Imaging of Biological Tissue Sections Using Ice as a Matrix
Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) mass spectrometry imaging of biological tissue sections using a layer of deposited ice as an energy-absorbing matrix was investigated. Dynamics of plume ablation were first explored using a nanosecond exposure shadowgraphy system designed to simultaneously collect pictures of the plume with a camera and collect the Fourier transform ion cyclotron resonance FT-ICR mass spectrum corresponding to that same ablation event. Ablation of fresh tissue analyzed with and without using ice as a matrix were compared using this technique. Effect of spot-to-spot distance, number of laser shots per pixel, and tissue condition (matrix) on ion abundance were also investigated for 50 μm-thick tissue sections. Finally, the statistical method called design of experiments was used to compare source parameters and determine the optimal conditions for IR-MALDESI of tissue sections using deposited ice as a matrix. With a better understanding of the fundamentals of ablation dynamics and a systematic approach to explore the experimental space, it was possible to improve ion abundance by nearly one order of magnitude.
- 29 May 2013
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 24 (7) , 1137-1145
Mass Recalibration of FT-ICR Mass Spectrometry Imaging Data Using the Average Frequency Shift of Ambient Ions
Achieving and maintaining high mass measurement accuracy (MMA) throughout a mass spectrometry imaging (MSI) experiment is vital to the identification of the observed ions. However, when using FTMS instruments, fluctuations in the total ion abundance at each pixel due to inherent biological variation in the tissue section can introduce space charge effects that systematically shift the observed mass. Herein we apply a recalibration based on the observed cyclotron frequency shift of ions found in the ambient laboratory environment, polydimethylcyclosiloxanes (PDMS). This calibration method is capable of achieving part per billion (ppb) mass accuracy with relatively high precision for an infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) MSI dataset. Comparisons with previously published mass calibration approaches are also presented.
- 29 May 2013
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 24 (7) , 1137-1145
Mass Recalibration of FT-ICR Mass Spectrometry Imaging Data Using the Average Frequency Shift of Ambient Ions
Achieving and maintaining high mass measurement accuracy (MMA) throughout a mass spectrometry imaging (MSI) experiment is vital to the identification of the observed ions. However, when using FTMS instruments, fluctuations in the total ion abundance at each pixel due to inherent biological variation in the tissue section can introduce space charge effects that systematically shift the observed mass. Herein we apply a recalibration based on the observed cyclotron frequency shift of ions found in the ambient laboratory environment, polydimethylcyclosiloxanes (PDMS). This calibration method is capable of achieving part per billion (ppb) mass accuracy with relatively high precision for an infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) MSI dataset. Comparisons with previously published mass calibration approaches are also presented.