SCSamuel Lucas Charreyron

Samuel Lucas Charreyron

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Samuel Lucas Charreyron has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • On the Workspace of Electromagnetic Navigation Systems

    by Quentin Boehler, Simone Gervasoni, Samuel L. Charreyron, Christophe Chautems, Bradley J. Nelson

    In remote magnetic navigation, a magnetic navigation system is used to generate magnetic fields to apply mechanical wrenches to steer a magnetic object. This technique can be applied to navigate untethered micro- and nanorobots, as well as tethered magnetic surgical tools for minimally invasive medicine. The design and characterization of these systems have been extensively investigated over the past decade. The determination of the region in space in which these systems can operate has yet to be formalized within the research community. This region is commonly referred to as the “workspace” and constitutes a central concept for any class of robotic system. We focus on magnetic navigation systems comprised of electromagnets and propose a first set of definitions for a magnetic workspace, a methodology to determine it, and evaluation metrics to analyze its characteristics. Our methodology and tools are illustrated with several examples of planar and spatial electromagnetic magnetic navigation systems for both didactic and realistic navigation scenarios.


  • Modeling Electromagnetic Navigation Systems

    by Samuel L. Charreyron, Quentin Boehler, Byungsoo Kim, Cameron Weibel, Christophe Chautems, Bradley J. Nelson

    Remote magnetic navigation is used for the manipulation of untethered micro and nanorobots, as well as tethered magnetic surgical tools for minimally invasive medicine. Mathematical modeling of the magnetic fields generated by magnetic navigation systems is a fundamental task in the control of such tools for biomedical applications. In this article, we describe and compare several existing and newly developed methods for representations of continuous magnetic fields using interpolation in the context of remote magnetic navigation. Clinical-scale electromagnetic navigation systems feature nonlinear magnetization and magnetization interactions between electromagnets, which renders accurate magnetic field modeling challenging. We first introduce a method that can adapt existing linear models to correct for nonlinear magnetization, with similar performance to the current state-of-the-art nonlinear model. Furthermore, we present a method based on convolutional neural networks.


  • A Magnetically Navigated Microcannula for Subretinal Injections

    by Samuel Lucas Charreyron, Quentin Boehler, Aschraf N. Danun, Alexandre Mesot, Matthias Becker, Bradley J. Nelson

    Retinal disorders, including age-related macular degeneration, are leading causes of vision loss worldwide. New treatments, such as gene therapies and stem cell regeneration, require therapeutics to be introduced to the subretinal space due to poor diffusion to the active component of the retina. Subretinal injections are a difficult and risky surgical procedure and have been suggested as a candidate for robot-assisted surgery. We propose a different actuation paradigm to existing robotic approaches using remote magnetic navigation to control a flexible microcannula. A flexible cannula allows for high dexterity and considerable safety advantages over rigid tools, while maintaining the benefits of micrometer precision, hand tremor removal, and telemanipulation. The position of the cannula is tracked in real-time using near-infrared tip illumination, allowing for semi-automatic placement of the cannula and an intuitive user interface. Using this tool, we successfully performed several subretinal injections in ex-vivo porcine eyes under both microscope and optical coherence tomography visualization.


  • A Magnetically Steered Endolaser Probe for Automated Panretinal Photocoagulation

    by Samuel L. Charreyron, Edoardo Gabbi, Quentin Boehler, Matthias Becker, Bradley J. Nelson

    The advanced state of diabetic retinopathy, a leading cause of blindness, is treated by panretinal photocoagulation (PRP), a repetitive procedure performed by a surgeon using a handheld laser probe. In its place we propose a soft-robotic flexible probe precisely steered using magnetic fields generated by an external magnetic steering system. We develop a kinematic model for the PRP task and show that the process can be automated given image feedback of the retina through a fundus camera. We demonstrate the concept in an eye phantom of a human eye, achieving clinical-level accuracy and faster speeds than human surgeons.


  • Real-Time Holographic Tracking and Control of Microrobots

    by Ayoung Hong, Burak Zeydan, Samuel Charreyron, Olgac Ergeneman, Salvador Pane, M. Fatih Toy, Andrew J. Petruska, Bradley J. Nelson

    Digital holography is used to track the three-dimensional position of a magnetic microrobot maneuvered in real time by means of an electromagnetic manipulation system. The method presented is able to process holograms at 40 Hz with a position accuracy in the imaging plane and in depth of $\pm$ 23 and $\pm$ 180 $\mu$ m, respectively. As this method does not require magnification, microrobots can be tracked in significantly larger working volumes than conventional optical methods. The performance of this tracking method is demonstrated by visually servoing a magnetic bead around a cubic trajectory.