Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Febrina Amelia Saputri has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Aliya Nur Hasanah

    Department of Pharmaceutical Analysis and Medicinal Chemistry, Faculty of Pharmacy, Universitas Padjadjaran, Indonesia

    1 shared publication
  • Anisahtul Alawiyah

    Department of Pharmaceutical Analysis and Medicinal Chemistry, Faculty of Pharmacy, Universitas Padjadjaran, Indonesia

    1 shared publication
  • Annisa Mayangsari

    Department of Pharmaceutical Analysis and Medicinal Chemistry, Faculty of Pharmacy, Universitas Padjadjaran, Jl Raya Bandung Sumedang Km 21 Jatinangor, West Java, Indonesia, 45363

    1 shared publication
  • Arif Satria Wira Kusuma

    Department of Biological Pharmacy, Faculty of Pharmacy, Universitas Padjadjaran, Indonesia

    1 shared publication
  • Ayu Brilliany Firsty

    Department of Pharmaceutical Analysis and Medicinal Chemistry, Faculty of Pharmacy, Universitas Padjadjaran, Indonesia

    1 shared publication
  • Daniel Blascke Carrão

    Departamento de Química, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, 14040-901, Ribeirao Preto, SP, Brazil

    1 shared publication

Latest Publications

  • Open Access

    A Review of Analytical Methods for Codeine Determination

    by Rimadani Pratiwi, Eka Noviana, Rizky Fauziati, Daniel Blascke Carrão, Firas Adinda Gandhi, Mutiara Aini Majid, Febrina Amelia Saputri

    Codeine is derived from morphine, an opioid analgesic, and has weaker analgesic and sedative effects than the parent molecule. This weak opioid is commonly used in combination with other drugs for over-the-counter cough relief medication. Due to the psychoactive properties of opioid drugs, the easily obtained codeine often becomes subject to misuse. Codeine misuse has emerged as a concerning public health issue due to its associated adverse effects such as headache, nausea, vomiting, and hemorrhage. Thus, it is very important to develop reliable analytical techniques to detect codeine for both quality control of pharmaceutical formulations and identifying drug misuse in the community. This review aims to provide critical outlooks on analytical methods applicable to the determination of codeine.


  • Open Access

    MOLECULARLY IMPRINTED POLYMER NANOPARTICLES (MIP-NPs) APPLICATIONS IN ELECTROCHEMICAL SENSORS

    by Diane Fauzi, Febrina Amelia Saputri

    Molecularly Imprinted Polymers (MIPs) is a polymer that binds together to form a specific binding site that is selective for certain analytes. Its high stability, its synthesize simplicity, and it can ease costs significantly make it was applied widely as a receptor instead of antibodies or enzymes. MIPs can be re-developed into MIPs nanoparticles (MIP-NPs) which have greater potential. MIPs use in electrochemical sensors have relevant applications in daily life and have been tested in human samples. Electrochemical sensors have been successfully functioned with MIP-NPs leading to real-time monitoring of drugs, pesticides, environmental contaminants, and secondary metabolites, as well as molecules with biological relevance. The aim of this review is to summarize the developments and applications of MIP-NPs as a selective recognition component in electrochemical sensors with special emphasis on their analytical applications.


  • Open Access

    THE OPTIMIZATION OF ELUTING CONDITION OF SOLID PHASE EXTRACTION METHOD FOR -MANGOSTIN PURIFICATION IN MANGOSTEEN PERICARP EXTRACT

    by Febrina Amelia Saputri, Annisa Mayangsari, Muchtaridi Muchtaridi

    Objective: To obtain the optimum condition of eluent selection for purification of α-mangostin in mangosteen pericarp extract with solid phase extraction (SPE) method. Methods: The analysis was conducted by SPE cartridge octadecylsilane (ODS)-5, solvents used were methanol for conditioning, aqua bidestilated for washing and three different eluents for eluting: methanol, ethanol and ethyl acetate. Results: Recovery value for each eluent were 32.4741% for methanol, 46.6130% for ethanol and 33.6383% for ethyl acetate. Comparison of alpha-mangostin level in the mangosteen pericarp extract for each eluent i.e. 14.4578% for methanol, 10.0598% for ethanol, and 14.2898 % for ethyl acetate while compared to the extract without SPE was 21.7934%. Conclusion: Ethanol had the highest recovery value, compared to methanol and ethyl acetate.


  • Open Access

    Development and validation of simple simultaneous analysis for amlodipine and glibenclamide by nonderivatization high-performance liquid chromatography-fluorescence

    by Febrina Amelia Saputri, Anisahtul Alawiyah, Ayu Brilliany Firsty, Sandra Megantara, Arif Satria Wira Kusuma, Taofik Rusdiana, Aliya Nur Hasanah, Mutakin Mutakin, Ingrid S Surono, Rizky Abdulah

    Studies have shown that about 65% of diabetics have hypertension. Treatment for diabetic patients with hypertension is usually given a combination of drugs such as amlodipine (AML) and glibenclamide (GLI). The aim of this study was to develop and validate the simple simultaneous analysis method for separation of AML and GLI using high-performance liquid chromatography (HPLC) with fluorescence detector without derivatization. The arrangement of isocratic and gradient methods, mobile phase compositions, and flow rates to develop and validate the simple simultaneous analysis method for separation of AML and GLI by nonderivatization HPLC fluorescence was done. Optimum condition was obtained using an RP 18 (125 mm × 4 mm, i.d., 5 μm) and guard column RP 18 (4 mm × 4 mm, i.d., 5 μm) with mobile phase composition containing acetonitrile and phosphate buffer pH 3.0 using a 20:80 gradient condition at flow rate 1.0 ml/min measured at 361 nm for λ excitation and 442 nm for λ emission for AML and 235 nm for λ excitation and 354 nm for λ emission for GLI. The analysis of AML and GLI demonstrated a valid result with r2 value 0.999, recoveries were 100.04% and 99.14% relative standard deviations were 0.508% and 0,797%, respectively, detection limits were 0.055 and 0.104 μg/ml, and quantification limits were 0.166 and 0.316 μg/ml, respectively. An accurate method of separation for AML and GLI using HPLC with fluorescence detector without derivatization has been validated.