Hou-Tai Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hou-Tai Chang has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- Inéz Frerichs
University Hospital Schleswig-Holstein
6 shared publications - Zhanqi Zhao
School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, China
6 shared publications - Knut Möller
Institute of Technical Medicine, Furtwangen University, 78054 Villingen-Schwenningen, Germany
3 shared publications - Mei-Yun Chang
Division of Respiratory Therapy, Department of Internal Medicine, Far Eastern Memorial Hospital, New Taipei City 220, Taiwan
3 shared publications - Yeong-Long Hsu
Department of Chest Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan
3 shared publications - Chen-Hsi Hsieh
Department of Medical Research, Mackay Memorial Hospital, Taipei, Taiwan
2 shared publications
Latest Publications
- Open Access
- 21 August 2024
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 11, 1391641
Optimizing patient outcomes in severe pneumonia: the role of multiplex PCR in the treatment of critically ill patients
Herein, we evaluated the optimal timing for implementing the BioFire® FilmArray® Pneumonia Panel (FA-PP) in the medical intensive care unit (MICU). Respiratory samples from 135 MICU-admitted patients with acute respiratory failure and severe pneumonia were examined using FA-PP. The cohort had an average age of 67.1 years, and 69.6% were male. Notably, 38.5% were smokers, and the mean acute physiology and chronic health evaluation-II (APACHE-II) score at initial MICU admission was 30.62, and the mean sequential organ failure assessment score (SOFA) was 11.23, indicating sever illness. Furthermore, 28.9, 52.6, and 43% of patients had a history of malignancy, hypertension, and diabetes mellitus, respectively. Community-acquired pneumonia accounted for 42.2% of cases, whereas hospital-acquired pneumonia accounted for 37%. The average time interval between pneumonia diagnosis and FA-PP implementation was 1.9 days, and the mean MICU length of stay was 19.42 days. The mortality rate was 50.4%. Multivariate logistic regression analysis identified two variables as significant independent predictors of mortality: APACHE-II score (p = 0.033, OR = 1.06, 95% CI 1.00–1.11), history of malignancy (OR = 3.89, 95% CI 1.64–9.26). The Kaplan–Meier survival analysis indicated that early FA-PP testing did not provide a survival benefit. The study suggested that the FA-PP test did not significantly impact the mortality rate of patients with severe pneumonia with acute respiratory failure. However, a history of cancer and a higher APACHE-II score remain important independent risk factors for mortality.
- 21 August 2024
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 11, 1391641
Open AccessOptimizing patient outcomes in severe pneumonia: the role of multiplex PCR in the treatment of critically ill patients
Herein, we evaluated the optimal timing for implementing the BioFire® FilmArray® Pneumonia Panel (FA-PP) in the medical intensive care unit (MICU). Respiratory samples from 135 MICU-admitted patients with acute respiratory failure and severe pneumonia were examined using FA-PP. The cohort had an average age of 67.1 years, and 69.6% were male. Notably, 38.5% were smokers, and the mean acute physiology and chronic health evaluation-II (APACHE-II) score at initial MICU admission was 30.62, and the mean sequential organ failure assessment score (SOFA) was 11.23, indicating sever illness. Furthermore, 28.9, 52.6, and 43% of patients had a history of malignancy, hypertension, and diabetes mellitus, respectively. Community-acquired pneumonia accounted for 42.2% of cases, whereas hospital-acquired pneumonia accounted for 37%. The average time interval between pneumonia diagnosis and FA-PP implementation was 1.9 days, and the mean MICU length of stay was 19.42 days. The mortality rate was 50.4%. Multivariate logistic regression analysis identified two variables as significant independent predictors of mortality: APACHE-II score (p = 0.033, OR = 1.06, 95% CI 1.00–1.11), history of malignancy (OR = 3.89, 95% CI 1.64–9.26). The Kaplan–Meier survival analysis indicated that early FA-PP testing did not provide a survival benefit. The study suggested that the FA-PP test did not significantly impact the mortality rate of patients with severe pneumonia with acute respiratory failure. However, a history of cancer and a higher APACHE-II score remain important independent risk factors for mortality.
- Open Access
- 29 September 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (10) , 2670
Effect of the Timing of Hyperbaric Oxygen Therapy on the Prognosis of Patients with Idiopathic Sudden Sensorineural Hearing Loss
This study aimed to evaluate the effects of hyperbaric oxygen therapy (HBOT) on the hearing recovery of patients with idiopathic sudden sensorineural hearing loss (ISSNHL). The clinical data of 79 patients diagnosed with ISSNHL and treated with HBOT between January 2017 and December 2019 were retrospectively reviewed. The pure tone audiometry (PTA) scores before and after HBOT were recorded. The associations of HBOT efficacy with demographic and clinical characteristics and the duration from disease onset to HBOT administration were determined. The average PTA score was 80.06 ± 25.94 dB before and 60.75 ± 21.26 dB after HBOT; the difference was significant. HBOT improved the hearing of 55.7% of the patients with ISSNHL (defined as an average PTA ≥ 11dB or a final average PTA score below 29 dB). There was a significant inverse relationship between the duration from symptom onset to HBOT administration and PTA score reduction after HBOT, which was adjusted for factors including age, sex, laterality of hearing loss, initial PTA score, reception of intratympanic steroid injections, tinnitus, dizziness, vertigo, diabetes, hypertension, and coronary artery disease. Commencing HBOT at an earlier stage is closely linked to greater improvements in hearing for patients with ISSNHL.
- 29 September 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (10) , 2670
Open AccessEffect of the Timing of Hyperbaric Oxygen Therapy on the Prognosis of Patients with Idiopathic Sudden Sensorineural Hearing Loss
This study aimed to evaluate the effects of hyperbaric oxygen therapy (HBOT) on the hearing recovery of patients with idiopathic sudden sensorineural hearing loss (ISSNHL). The clinical data of 79 patients diagnosed with ISSNHL and treated with HBOT between January 2017 and December 2019 were retrospectively reviewed. The pure tone audiometry (PTA) scores before and after HBOT were recorded. The associations of HBOT efficacy with demographic and clinical characteristics and the duration from disease onset to HBOT administration were determined. The average PTA score was 80.06 ± 25.94 dB before and 60.75 ± 21.26 dB after HBOT; the difference was significant. HBOT improved the hearing of 55.7% of the patients with ISSNHL (defined as an average PTA ≥ 11dB or a final average PTA score below 29 dB). There was a significant inverse relationship between the duration from symptom onset to HBOT administration and PTA score reduction after HBOT, which was adjusted for factors including age, sex, laterality of hearing loss, initial PTA score, reception of intratympanic steroid injections, tinnitus, dizziness, vertigo, diabetes, hypertension, and coronary artery disease. Commencing HBOT at an earlier stage is closely linked to greater improvements in hearing for patients with ISSNHL.
- Open Access
- 23 June 2023
- Published by MDPI AG in Tropical Medicine and Infectious Disease
- Vol. 8 (7) , 335
Single-Center Experience of Control of Ventilator-Circuit-Transmitted Burkholderia cepacia Outbreak in an Intensive Care Unit
Burkholderia cepacia is an emerging nosocomial pathogen frequently associated with outbreaks, but the exact transmission route of this pathogen can at times be elusive in spite of extensive environmental investigative cultures. Active surveillance for sputum cultures was performed for all patients from September 2008 to September 2009 in an intensive care unit (ICU) with B. cepacia outbreak. With evidence of persistent positive conversion of sputum cultures (colonization) and infections among patients, discontinuing re-usable ventilator circuits was introduced. A total of 689 patients were admitted to this unit for a mean duration of 8.7 ± 7.5 days. There were 489 patients (71.0%) with a stay for one to ten days; 161 (23.4%) patients for 11 to 20 days; and 39 (5.7%) with over 20 days. In the first group, 13.5% of patients had cultures converting from negative to positive, in contrast to 66.7% in the last group (p < 0.01). With intervention of using disposable ventilator circuits since June 2009, the incidence of isolated B. cepacia decreased gradually. The estimated 30-day isolation-free probabilities of the groups before, during, one month (August 2009) after, and two months (September 2009) after this intervention were 38.5%, 47.3%, 66.5%, and 96.0%, respectively (p < 0.01). Furthermore, the effect of discontinuing reusable ventilator circuit persisted in the following 6 years; both total isolates of B. cepacia and the infection caused by it were much lower compared to the outbreak period. In summary, this six-year outbreak in a medical ICU persisted until reusable ventilator circuits were discontinued in 2009. The effect of disposable circuits on the decreased incidence of B. cepacia infection maintained in the following years.
- 23 June 2023
- Published by MDPI AG in Tropical Medicine and Infectious Disease
- Vol. 8 (7) , 335
Open AccessSingle-Center Experience of Control of Ventilator-Circuit-Transmitted Burkholderia cepacia Outbreak in an Intensive Care Unit
Burkholderia cepacia is an emerging nosocomial pathogen frequently associated with outbreaks, but the exact transmission route of this pathogen can at times be elusive in spite of extensive environmental investigative cultures. Active surveillance for sputum cultures was performed for all patients from September 2008 to September 2009 in an intensive care unit (ICU) with B. cepacia outbreak. With evidence of persistent positive conversion of sputum cultures (colonization) and infections among patients, discontinuing re-usable ventilator circuits was introduced. A total of 689 patients were admitted to this unit for a mean duration of 8.7 ± 7.5 days. There were 489 patients (71.0%) with a stay for one to ten days; 161 (23.4%) patients for 11 to 20 days; and 39 (5.7%) with over 20 days. In the first group, 13.5% of patients had cultures converting from negative to positive, in contrast to 66.7% in the last group (p < 0.01). With intervention of using disposable ventilator circuits since June 2009, the incidence of isolated B. cepacia decreased gradually. The estimated 30-day isolation-free probabilities of the groups before, during, one month (August 2009) after, and two months (September 2009) after this intervention were 38.5%, 47.3%, 66.5%, and 96.0%, respectively (p < 0.01). Furthermore, the effect of discontinuing reusable ventilator circuit persisted in the following 6 years; both total isolates of B. cepacia and the infection caused by it were much lower compared to the outbreak period. In summary, this six-year outbreak in a medical ICU persisted until reusable ventilator circuits were discontinued in 2009. The effect of disposable circuits on the decreased incidence of B. cepacia infection maintained in the following years.
- Open Access
- 21 June 2023
- Published by Springer Nature in Critical Care
- Vol. 27 (1) , 1-3
The absolute value of recruitment-to-inflation ratio does not correlate with the recruited volume
- 21 June 2023
- Published by Springer Nature in Critical Care
- Vol. 27 (1) , 1-3
Open AccessThe absolute value of recruitment-to-inflation ratio does not correlate with the recruited volume
- Open Access
- 17 April 2023
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 10
Hyperbaric oxygen therapy as rescue therapy for pediatric frosted branch angiitis with Purtscher-like retinopathy: A case report
Introduction: Frosted branch angiitis (FBA) is an uncommon uveitis characterized by fulminant retinal vasculitis. Purtscher-like retinopathy (PuR) is a rare retinal angiopathy associated with a non-traumatic etiology. Both FBA and PuR can cause profound visual impairments.Case report: We describe the case of a 10-year-old male who presented with sudden bilateral painless visual loss due to FBA with concurrent PuR, with notable viral prodrome 1 month prior to presentation. Systemic investigations revealed a recent herpes simplex virus 2 infection with a high titer of IgM, positive antinuclear antibody (ANA) (1:640), and abnormal liver function tests. After administration of systemic corticosteroids, anti-viral agents, and subsequent immunosuppressive medications, the FBA was gradually alleviated. However, fundoscopy and optical coherence tomography (OCT) revealed persistent PuR and macular ischemia. Hence, hyperbaric oxygen therapy was administered as a rescue strategy, which resulted in gradual bilateral visual acuity improvement.Conclusion: Hyperbaric oxygen therapy may be a beneficial rescue treatment for retinal ischemia secondary to FBA with PuR.
- 17 April 2023
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 10
Open AccessHyperbaric oxygen therapy as rescue therapy for pediatric frosted branch angiitis with Purtscher-like retinopathy: A case report
Introduction: Frosted branch angiitis (FBA) is an uncommon uveitis characterized by fulminant retinal vasculitis. Purtscher-like retinopathy (PuR) is a rare retinal angiopathy associated with a non-traumatic etiology. Both FBA and PuR can cause profound visual impairments.Case report: We describe the case of a 10-year-old male who presented with sudden bilateral painless visual loss due to FBA with concurrent PuR, with notable viral prodrome 1 month prior to presentation. Systemic investigations revealed a recent herpes simplex virus 2 infection with a high titer of IgM, positive antinuclear antibody (ANA) (1:640), and abnormal liver function tests. After administration of systemic corticosteroids, anti-viral agents, and subsequent immunosuppressive medications, the FBA was gradually alleviated. However, fundoscopy and optical coherence tomography (OCT) revealed persistent PuR and macular ischemia. Hence, hyperbaric oxygen therapy was administered as a rescue strategy, which resulted in gradual bilateral visual acuity improvement.Conclusion: Hyperbaric oxygen therapy may be a beneficial rescue treatment for retinal ischemia secondary to FBA with PuR.
- 28 June 2022
- Published by IOP Publishing in Physiological Measurement
- Vol. 43 (6) , 064001
Is there a need for individualized adjustment of electrode belt position during EIT-guided titration of positive end-expiratory pressure?
Objective . The aim of the present study was to evaluate the variation of tidal volume-to-impedance ratio ( V T / Z T ) during positive end-expiratory pressure (PEEP) titration with electrical impedance tomography (EIT) measurement. Approach . Forty-two patients with acute respiratory distress syndrome were retrospectively analyzed. An incremental and subsequently a decremental PEEP trial were performed with steps of 2 cm H 2 O and duration of 2 min per step during volume-controlled ventilation with decelerating flow. EIT measurement was conducted in the 5th intercostal space and V T was recorded simultaneously. The variation of V T / Z T ( RatioV ) was defined as the changes in percentage to average ratio per cm H 2 O PEEP change. A z-score > 1 was considered as a significant variation and an implication that the measurement plane was inadequate. Main results . The RatioV of 42 patients was 1.29 ± 0.80%·cm H 2 O −1 . A z-score of 1 corresponded to the variation of 2.09%·cm H 2 O −1 . Seven patients (16.7%) had a z-score > 1 and showed either positive or negative correlation between the volume-to-impedance ratio and PEEP. Significance . Electrode placement at 5th intercostal space might not be ideal for every individual during EIT measurement. Evaluation of volume-to-impedance ratio variation is necessary for patients undergoing maneuvers with wide alteration in absolute lung volume.
- 28 June 2022
- Published by IOP Publishing in Physiological Measurement
- Vol. 43 (6) , 064001
Is there a need for individualized adjustment of electrode belt position during EIT-guided titration of positive end-expiratory pressure?
Objective . The aim of the present study was to evaluate the variation of tidal volume-to-impedance ratio ( V T / Z T ) during positive end-expiratory pressure (PEEP) titration with electrical impedance tomography (EIT) measurement. Approach . Forty-two patients with acute respiratory distress syndrome were retrospectively analyzed. An incremental and subsequently a decremental PEEP trial were performed with steps of 2 cm H 2 O and duration of 2 min per step during volume-controlled ventilation with decelerating flow. EIT measurement was conducted in the 5th intercostal space and V T was recorded simultaneously. The variation of V T / Z T ( RatioV ) was defined as the changes in percentage to average ratio per cm H 2 O PEEP change. A z-score > 1 was considered as a significant variation and an implication that the measurement plane was inadequate. Main results . The RatioV of 42 patients was 1.29 ± 0.80%·cm H 2 O −1 . A z-score of 1 corresponded to the variation of 2.09%·cm H 2 O −1 . Seven patients (16.7%) had a z-score > 1 and showed either positive or negative correlation between the volume-to-impedance ratio and PEEP. Significance . Electrode placement at 5th intercostal space might not be ideal for every individual during EIT measurement. Evaluation of volume-to-impedance ratio variation is necessary for patients undergoing maneuvers with wide alteration in absolute lung volume.
- Open Access
- 22 January 2021
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 21 (1) , 1-5
The use of electrical impedance tomography for individualized ventilation strategy in COVID-19: a case report
Background: Clinical management of COVID-19 requires close monitoring of lung function. While computed tomography (CT) offers ideal way to identify the phenotypes, it cannot monitor the patient response to therapeutic interventions. We present a case of ventilation management for a COVID-19 patient where electrical impedance tomography (EIT) was used to personalize care. Case presentation: The patient developed acute respiratory distress syndrome, required invasive mechanical ventilation, and was subsequently weaned. EIT was used multiple times: to titrate the positive end-expiratory pressure, understand the influence of body position, and guide the support levels during weaning and after extubation. We show how EIT provides bedside monitoring of the patient´s response to various therapeutic interventions and helps guide treatments. Conclusion: EIT provides unique information that may help the ventilation management in the pandemic of COVID-19.
- 22 January 2021
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 21 (1) , 1-5
Open AccessThe use of electrical impedance tomography for individualized ventilation strategy in COVID-19: a case report
Background: Clinical management of COVID-19 requires close monitoring of lung function. While computed tomography (CT) offers ideal way to identify the phenotypes, it cannot monitor the patient response to therapeutic interventions. We present a case of ventilation management for a COVID-19 patient where electrical impedance tomography (EIT) was used to personalize care. Case presentation: The patient developed acute respiratory distress syndrome, required invasive mechanical ventilation, and was subsequently weaned. EIT was used multiple times: to titrate the positive end-expiratory pressure, understand the influence of body position, and guide the support levels during weaning and after extubation. We show how EIT provides bedside monitoring of the patient´s response to various therapeutic interventions and helps guide treatments. Conclusion: EIT provides unique information that may help the ventilation management in the pandemic of COVID-19.
- Open Access
- 29 May 2020
- Published by Springer Nature in Critical Care
- Vol. 24 (1) , 1-3
COVID-19 pneumonia: phenotype assessment requires bedside tools
- 29 May 2020
- Published by Springer Nature in Critical Care
- Vol. 24 (1) , 1-3
Open AccessCOVID-19 pneumonia: phenotype assessment requires bedside tools
- 5 October 2019
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 34 (5) , 1005-1013
The incidence and interpretation of large differences in EIT-based measures for PEEP titration in ARDS patients
Positive end-expiratory pressure (PEEP) can be titrated by electrical impedance tomography (EIT). The aim of the present study was to examine the performance of different EIT measures during PEEP trials with the aim of identifying “optimum” PEEP and to provide possible interpretations of largely diverging results. After recruitment (maximum plateau pressure 35 cmH2O), decremental PEEP trial with steps of 2 cmH2O and duration of 2 min per step was performed. Ventilation gain and loss, the global inhomogeneity (GI) index, trend of end-expiratory lung impedance (EELI) and regional compliance (Creg) for estimation of overdistension and collapse were calculated. Largely diverging results of PEEP selection among the measures were defined as differences ≥ 4 PEEP steps (i.e. ≥ 8 cmH2O). In 30 ARDS patients we examined so far, 3 patients showed significant differences in PEEP selections. Overdistension and collapse estimation based on Creg tended to select lower PEEP while the GI index and EELI trend suggested higher PEEP settings. Regional inspiration times were heterogeneous indicating that the assumption of a uniform driving pressure in the calculation of Creg may not be valid. Judging by the predominant ventilation distribution in the most dependent regions, these patients were non-recruitable with the applied recruitment method or pressure levels. The existence of differences in the recommended PEEP among the analyzed EIT measures might be an indicator of non-recruitable lungs and heterogeneous airway resistances. In these extreme cases, the largely diverging results may prompt the attending clinician to develop individual ventilation strategies. Clinical Trial Registration Registration number NCT03112512, https://clinicaltrials.gov/ Registered 13 April 2017.
- 5 October 2019
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 34 (5) , 1005-1013
The incidence and interpretation of large differences in EIT-based measures for PEEP titration in ARDS patients
Positive end-expiratory pressure (PEEP) can be titrated by electrical impedance tomography (EIT). The aim of the present study was to examine the performance of different EIT measures during PEEP trials with the aim of identifying “optimum” PEEP and to provide possible interpretations of largely diverging results. After recruitment (maximum plateau pressure 35 cmH2O), decremental PEEP trial with steps of 2 cmH2O and duration of 2 min per step was performed. Ventilation gain and loss, the global inhomogeneity (GI) index, trend of end-expiratory lung impedance (EELI) and regional compliance (Creg) for estimation of overdistension and collapse were calculated. Largely diverging results of PEEP selection among the measures were defined as differences ≥ 4 PEEP steps (i.e. ≥ 8 cmH2O). In 30 ARDS patients we examined so far, 3 patients showed significant differences in PEEP selections. Overdistension and collapse estimation based on Creg tended to select lower PEEP while the GI index and EELI trend suggested higher PEEP settings. Regional inspiration times were heterogeneous indicating that the assumption of a uniform driving pressure in the calculation of Creg may not be valid. Judging by the predominant ventilation distribution in the most dependent regions, these patients were non-recruitable with the applied recruitment method or pressure levels. The existence of differences in the recommended PEEP among the analyzed EIT measures might be an indicator of non-recruitable lungs and heterogeneous airway resistances. In these extreme cases, the largely diverging results may prompt the attending clinician to develop individual ventilation strategies. Clinical Trial Registration Registration number NCT03112512, https://clinicaltrials.gov/ Registered 13 April 2017.
- Open Access
- 17 January 2019
- Published by Elsevier in Annals of Intensive Care
- Vol. 9 (1) , 7-9
Positive end-expiratory pressure titration with electrical impedance tomography and pressure–volume curve in severe acute respiratory distress syndrome
- 17 January 2019
- Published by Elsevier in Annals of Intensive Care
- Vol. 9 (1) , 7-9
Open AccessPositive end-expiratory pressure titration with electrical impedance tomography and pressure–volume curve in severe acute respiratory distress syndrome