CCCharles P. Clark

Charles P. Clark

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Charles P. Clark has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Closable Valves and Channels for Polymeric Microfluidic Devices

    by Charles P. Clark, M. Shane Woolf, Sarah L. Karstens, Hannah M. Lewis, Aeren Q. Nauman, James P. Landers

    This study explores three unique approaches for closing valves and channels within microfluidic systems, specifically multilayer, centrifugally driven polymeric devices. Precise control over the cessation of liquid movement is achieved through either the introduction of expanding polyurethane foam, the application of direct contact heating, or the redeposition of xerographic toner via chloroform solvation and evaporation. Each of these techniques modifies the substrate of the microdevice in a different way. All three are effective at closing a previously open fluidic pathway after a desired unit operation has taken place, i.e., sample metering, chemical reaction, or analytical measurement. Closing previously open valves and channels imparts stringent fluidic control—preventing backflow, maintaining pressurized chambers within the microdevice, and facilitating sample fractionation without cross-contamination. As such, a variety of microfluidic bioanalytical systems would benefit from the integration of these valving approaches.


  • Open Access

    Real Time Electronic Feedback for Improved Acoustic Trapping of Micron-Scale Particles

    by Charles P. Clark, Vahid Farmehini, Liam Spiers, M. Shane Woolf, Nathan S. Swami, James P. Landers

    Acoustic differential extraction has been previously reported as a viable alternative to the repetitive manual pipetting and centrifugation steps for isolating sperm cells from female epithelial cells in sexual assault sample evidence. However, the efficiency of sperm cell isolation can be compromised in samples containing an extremely large number of epithelial cells. When highly concentrated samples are lysed, changes to the physicochemical nature of the medium surrounding the cells impacts the acoustic frequency needed for optimal trapping. Previous work has demonstrated successful, automated adjustment of acoustic frequency to account for changes in temperature and buffer properties in various samples. Here we show that, during acoustic trapping, real-time monitoring of voltage measurements across the piezoelectric transducer correlates with sample-dependent changes in the medium. This is achieved with a wideband peak detector circuit, which identifies the resonant frequency with minimal disruption to the applied voltage. We further demonstrate that immediate, corresponding adjustments to acoustic trapping frequency provides retention of sperm cells from high epithelial cell-containing mock sexual assault samples.


  • Acoustic trapping of sperm cells from mock sexual assault samples

    by Charles P. Clark, Kerui Xu, Orion Scott, Jeffrey Hickey, An-Chi Tsuei, Kimberly Jackson, James P. Landers


  • Isolation of a Low Number of Sperm Cells from Female DNA in a Glass–PDMS–Glass Microchip via Bead-Assisted Acoustic Differential Extraction

    by Kerui Xu, Charles P. Clark, Brian L. Poe, Jenny A. Lounsbury, Johan Nilsson, Thomas Laurell, James P. Landers

    We report an improved separation method for the isolation of sperm cells from dilute, “large volume” samples containing female DNA using bead-assisted acoustic trapping. In an enclosed glass–PDMS–glass (GPG) resonator, we exploit a three-layer microfluidic architecture to generate “trapping nodes” in ultrasonic standing waves. We investigate the dependence of trapping efficiency on particle concentration for both sperm cells and polymeric beads. After determination of the critical concentration of polymeric beads required to seed the trapping event, sperm cells in dilute solution are trapped as a result of the enhanced secondary radiation force (SRF). Sperm-cell-containing samples with volumes up to 300 μL and cell concentrations as low as ∼10 cells/μL are amenable to effective trapping in the presence of an abundance of female DNA in solution. Complete processing of samples is accomplished with separation of the female and male fractions within 15 min. We demonstrate that the collected fractions are amenable to subsequent DNA extraction, short tandem repeat PCR, and the generation of STR profiles for the isolated sperm cells.