Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Guofeng Cui has a total of 76 co-authors. Here are the top co-authors by number of shared publications:

  • Jie Zhao

    School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou, 510640, People's Republic of China

    11 shared publications
  • Jie Zhao

    School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510640, P. R. China

    8 shared publications
  • Peng Sun

    Guangdong Provincial Engineering Technology Research Center of Vacuum Coating Technologies and New Energy Materials, Siyuan Laboratory, Guangzhou Key Laboratory of Vacuum Coating Technologies and New Energy Materials, Department of Physics, Jinan University, Guangzhou, Guangdong 510632, People's Republic of China

    7 shared publications
  • Peng Sun

    Siyuan Laboratory, Guangzhou Key Laboratory of Vacuum Coating Technologies and New Energy Materials, Guangdong Provincial Engineering Technology Research Center of Vacuum Coating Technologies and New Energy Materials, Guangdong Provincial Key Laboratory of Nanophotonic Manipulation, Department of Physics, College of Physics & Optoelectronic Engineering, Jinan University, Guangdong 510632, People's Republic of China

    7 shared publications
  • Gang Wu

    Department of Energy, Environmental & Chemical Engineering Washington University in St. Louis St. Louis MO 63130 USA

    6 shared publications
  • Meijia Qiu

    Key Laboratory for Polymeric Composite & Functional Materials of Ministry of Education, School of Chemistry, Key Laboratory of Low-carbon Chemistry & Energy Conservation of Guangdong Province, Sun Yat-sen University, Guangzhou 510275, People’s Republic of China

    6 shared publications

Latest Publications

  • A novel carbonate ion-selective electrode based on pine-leaf porous silver nanoparticles/polyaniline composites as the solid contact for marine monitoring

    by Shaojun Ke, Jie Zhao, Xinyu Meng, Suyun Wei, Mingjia Zou, Qingze Han, Guofeng Cui

    The design of carbonate-selective electrodes with high sensitivity, stability, and selectivity holds significant potential for applications in marine environmental monitoring. In this study, a novel pine-leaf porous structure carbonate ion-selective electrode was prepared with a solid contact layer of silver nanoparticles/polyaniline (AgNPs@PANI) using a two-step electrochemical method involving electropolymerized PANI and electrodeposited AgNPs. The novel structure provides additional charge transport paths and a larger contact area for carbonate ions passing through the selective membrane, thereby enhancing the membrane's carbonate-responsive performance. The results indicate that the GE/AgNPs@PANI/CO3 2−-ISE demonstrates a near-Nernst response (−29.5 ± 0.2 mV per decade) to carbonate ions over a wide concentration range (10−1–10−6 M) as well as a low carbonate detection limit (1.15 × 10−7 M), with excellent performance in terms of response speed (5.5 s), reversibility (1.35 mV), long-term potential stability (0.17 mV h−1), and selectivity. The developed electrode was applied to the detection of carbonate in real seawater using the standard addition method, and the average recovery was found to be 95–105%. Meanwhile, the results of carbonate ion detection in real samples using this electrode were largely consistent with those obtained by potentiometric titration, demonstrating significant practicality in marine chemistry research.


  • Negative space charge modulated ion transport through PEDOT:PSS hydrogels integrating nanofluidic channels for highly efficient osmotic energy harvesting

    by Rui Zhu, Peng Sun, Guofeng Cui, Yaoguang Yu, Shaojun Ke, Jie Zhao

    The exploitation of ion-selective membranes with high power density and low resistance is crucial for harvesting osmotic energy in natural environments. However, the exploration of membranes that synergistically satisfy the demands of these properties in osmotic energy conversion remains largely unresolved. Herein, we demonstrate the application of a negative surface-modified 3D porous poly(3,4-ethylenedioxythiophene)–poly(styrenesulfonate) (PEDOT:PSS) hydrogel for osmotic membranes, which effectively improved their deficiencies. Experiments, validation and simulations confirmed that the hydrogel membranes have remarkable space charge-modulated ion transport properties. Consequently, an impressive power output of 6.26 W m−2 can be realized, which exceeds the prevailing commercial standard (5 W m−2). Meanwhile, five device units were connected in series to charge a supercapacitor which exhibited an impressive selectivity rate of 95.6%, coupled with an electrochemical energy conversion efficiency of approximately 45.8%. This research paves a new avenue towards the application of hydrogels in ultra-high performance osmotic membranes.


  • Engineering Interconnected Nanofluidic Channel in a Hydrogel Supernetwork toward K+ Ion Accelerating Transport and Efficient Sensing

    by Rui Zhu, Peng Sun, Guofeng Cui, Jie Zhao, Yaoguang Yu

    Ion transportation via the mixed mechanisms of hydrogels underpins ultrafast biological signal transmission in nature, and its application to the rapid and sensitive sensing detection of human specific ions is of great interest for the field of medical science. However, current research efforts are still unable to achieve transmission results that are comparable to those of bioelectric signals. Herein, 3D interconnected nanochannels based on poly(pyrrole-co-dopamine)/poly(vinyl alcohol) (P(Py-co-DA)/PVA) supernetwork conductive hydrogels are designed and fabricated as stimuli-responsive structures for K+ ions. Distinct from conventional configurations, which exhibit rapid electron transfer and permeability to biosubstrates, interconnected nanofluidic nanochannels collaborated with the P(Py-co-DA) conductive polymer in the supernetwork conductive hydrogel significantly improve conductivity (88.3 mS/cm), ion transport time (0.1 s), and ion sensitivity (74.6 mV/dec). The faster ion response time is attributed to the synergism of excellent conductivity originating from the P(Py-co-DA) polymer and the electronic effect in the interconnected nanofluidic channels. Furthermore, the supernetwork conductive hydrogel demonstrates K+ ion selectivity relative to other cations in biofluids such as Na+, Mg2+, and Ca2+. The DFT calculation indicates that the small solvation energy and low chemical transfer resistance are the main reasons for the excellent K+ ion selectivity. Finite element analysis (FEA) simulations further support these experimental results. Consequently, the P(Py-co-DA)/PVA supernetwork conductive hydrogels enriched with the 3D interconnected nanofluidic channels developed in this work possess excellent sensing of K+ ions. This strategy provides great insight into efficient ion sensing in traditional biomedical sensing that has not been explored by previous researchers.


  • A novel strategy for the simultaneous discrimination of dopamine and epinephrine by cyclic square wave voltammetry implemented with a customized potentiostat

    by Yuheng Deng, Jie Zhao, Yaoguang Yu, Junhan Gao, Shifan Zhao, Jianying Yuan, Qingze Han, Guofeng Cui

    An electrochemical strategy for the simultaneous detection of DA and EP with high sensitivity by cyclic square wave voltammetry using a modified open source potentiostat.


  • Chaotropic Polymer Additive with Ion Transport Tunnel Enable Dendrite-Free Zinc Battery

    by Meijia Qiu, Peng Sun, Guofeng Cui, Wenjie Mai

    Zn batteries are considered the new-generation candidate for large-scale energy storage systems, taking both safety and environmental problems into account. They are still restricted by unexpected dendrite/byproducts occurring on the Zn anodes. We hereby screen a powerful polymer type additive, hyaluronic acid (HA), to regulate the typical ZnSO4 electrolyte for obtaining dendrite-free Zn ion batteries. The intrinsically chaotropic property of the HA molecule can efficiently destruct the original hydrogen-bonds from H2O-H2O, thus restricting the common parasitic reactions derived from the large amount of active water molecules. Simultaneously, the abundant functional groups along the long chain from HA additives can construct an effective tunnel for transferring Zn2+ smoothly, enabling an obviously improved Zn ion transference number of 0.62. Owning to the above intriguing mechanism for regulating the solvation structure of electrolyte systems, the HA additives can greatly increase the cycling life of Zn-Zn symmetric cells to 2200 and 800 h under the conditions of 1 mA cm-2/1 mAh cm-2 and 5 mA cm-2/5 mAh cm-2, respectively. Modified performance for both Zn-Ti and Zn-MnO2 can all be realized by this valid additive, elucidating it can be potentially utilized in large-scale Zn based aqueous energy storage devices.


  • A graphene-based electrochemical flow analysis device for simultaneous determination of dopamine, 5-hydroxytryptamine, and melatonin

    by Huizhen Deng, Jie Zhao, Shifan Zhao, Shuai Jiang, Guofeng Cui

    A graphene-based electrochemical flow analysis device for simultaneous determination of dopamine, 5-hydroxytryptamine, and melatonin.


  • Open Access

    Manipulating Interfacial Stability Via Absorption-Competition Mechanism for Long-Lifespan Zn Anode

    by Meijia Qiu, Liang Ma, Peng Sun, Zilong Wang, Guofeng Cui, Wenjie Mai

    The stability of Zn anode in various Zn-based energy storage devices is the key problem to be solved. Herein, aromatic aldehyde additives are selected to modulate the interface reactions between the Zn anode and electrolyte. Through comprehensively considering electrochemical measurements, DFT calculations and FEA simulations, novel mechanisms of one kind of aromatic aldehyde, veratraldehyde in inhibiting Zn dendrite/by-products can be obtained. This additive prefers to absorb on the Zn surface than H2O molecules and Zn2+, while competes with hydrogen evolution reaction and Zn plating/stripping process via redox reactions, thus preventing the decomposition of active H2O near the interface and uncontrollable Zn dendrite growth via a synactic absorption-competition mechanism. As a result, Zn–Zn symmetric cells with the veratraldehyde additive realize an excellent cycling life of 3200 h under 1 mA cm−2/1 mAh cm−2 and over 800 h even under 5 mA cm−2/5 mAh cm−2. Moreover, Zn–Ti and Zn–MnO2 cells with the veratraldehyde additive both obtain elevated performance than that with pure ZnSO4 electrolyte. Finally, two more aromatic aldehyde additives are chosen to prove their universality in stabilizing Zn anodes.


  • Liquid-like Polymer Coating as a Promising Candidate for Reducing Electrode Contamination and Noise in Complex Biofluids

    by Chengduan Yang, Cheng Yang, Xiangling Li, Aihua Zhang, Gen He, Qianni Wu, Xingxing Liu, Shuang Huang, Xinshuo Huang, Guofeng Cui, et al.

    Biosensors that can automatically and continuously track fluctuations in biomarker levels over time are essential for real-time sensing in biomedical and environmental applications. Although many electrochemical sensors have been developed to quickly and sensitively monitor biomarkers, their sensing stability in complex biofluids is disturbed by unavoidable nonspecific adhesion of proteins or bacteria. Recently, various substrate surface modification techniques have been developed to resist biofouling, yet functionalization of electrodes in sensors to be anti-biofouling is rarely achieved. Here, we report an integrated three-electrode system (ITES) modified with a “liquid-like” polydimethylsiloxane (PDMS) brush that can continuously and stably monitor reactive oxygen species (ROS) in complex fluids. Based on the slippery “liquid-like” coating, the modified ITES surface could prevent the adhesion of various liquids as well as the adhesion of proteins and bacteria. The “liquid-like” coating does not significantly affect the sensitivity of the electrode in detecting ROS, while the sensing performance could remain stable and free of bacterial attack even after 3 days of incubation with bacteria. In addition, the PDMS brush-modified ITES (PMITES) could continuously record ROS levels in bacterial-rich fluids with excellent stability over 24 h due to the reduced bacterial contamination on the electrode surface. This technique offers new opportunities for continuous and real-time monitoring of biomarkers that will facilitate the development of advanced sensors for biomedical and environmental applications.