Daihua Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daihua Yu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Brad Edward Dicianno
University of Pittsburgh
6 shared publications - Bambang Parmanto
Department of Health Information Management, University of Pittsburgh, Pittsburgh, PA 15260, USA
5 shared publications - Gede Pramana
University of Pittsburgh
4 shared publications Andrea D. Fairman
2 shared publications- Andrea D. Fairman
Department of Occupational Therapy, College of Health and Wellness, Carlow University, Pittsburgh, PA 15213, USA
2 shared publications - Kuntal Chowdhary
Department of Rehabilitation Medicine, NewYork-Presbyterian Hospital, New York, USA
2 shared publications
Latest Publications
- Open Access
- 24 February 2022
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 9 (1) , e23794
User-Centered Design to Enhance mHealth Systems for Individuals With Dexterity Impairments: Accessibility and Usability Study
Background: Mobile health systems have been shown to be useful in supporting self-management by promoting adherence to schedules and longitudinal health interventions, especially in people with disabilities. The Interactive Mobile Health and Rehabilitation (iMHere) system was developed to empower people with disabilities and those with chronic conditions with supports needed for self-management and independent living. Since the first iteration of the iMHere 1.0 app, several studies have evaluated the accessibility and usability of the system. Potential opportunities to improve and simplify the user interface were identified, and the iMHere modules were redesigned accordingly. Objective: In this study, we aim to evaluate the usability of the redesigned modules within the iMHere 1.0 app. Methods: We evaluated the original and redesigned iMHere modules—MyMeds and SkinCare. The Purdue Pegboard Test was administered to assess the participants’ dexterity levels. Participants were then asked to perform a set of tasks using both the original and redesigned MyMeds and SkinCare modules to assess their efficiency and effectiveness. Usability was measured using the Telehealth Usability Questionnaire to evaluate 10 new accessibility features that were added to the redesigned app. Participants were also asked which version they preferred. Results: In total, 24 participants with disabilities and varying degrees of dexterity impairments completed the entire study protocol. Participants displayed improved efficiency and effectiveness when using the redesigned modules compared with the original modules. The participants also reported improved usability and preferred the redesigned modules. Conclusions: This study demonstrated that the iMHere system became more efficient, effective, and usable for individuals with dexterity impairments after redesigning it according to user-centered principles.
- 24 February 2022
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 9 (1) , e23794
Open AccessUser-Centered Design to Enhance mHealth Systems for Individuals With Dexterity Impairments: Accessibility and Usability Study
Background: Mobile health systems have been shown to be useful in supporting self-management by promoting adherence to schedules and longitudinal health interventions, especially in people with disabilities. The Interactive Mobile Health and Rehabilitation (iMHere) system was developed to empower people with disabilities and those with chronic conditions with supports needed for self-management and independent living. Since the first iteration of the iMHere 1.0 app, several studies have evaluated the accessibility and usability of the system. Potential opportunities to improve and simplify the user interface were identified, and the iMHere modules were redesigned accordingly. Objective: In this study, we aim to evaluate the usability of the redesigned modules within the iMHere 1.0 app. Methods: We evaluated the original and redesigned iMHere modules—MyMeds and SkinCare. The Purdue Pegboard Test was administered to assess the participants’ dexterity levels. Participants were then asked to perform a set of tasks using both the original and redesigned MyMeds and SkinCare modules to assess their efficiency and effectiveness. Usability was measured using the Telehealth Usability Questionnaire to evaluate 10 new accessibility features that were added to the redesigned app. Participants were also asked which version they preferred. Results: In total, 24 participants with disabilities and varying degrees of dexterity impairments completed the entire study protocol. Participants displayed improved efficiency and effectiveness when using the redesigned modules compared with the original modules. The participants also reported improved usability and preferred the redesigned modules. Conclusions: This study demonstrated that the iMHere system became more efficient, effective, and usable for individuals with dexterity impairments after redesigning it according to user-centered principles.
- Open Access
- 23 August 2020
- Published by JMIR Publications Inc. in JMIR Preprints
User-Centered Design to Enhance mHealth Systems for Individuals With Dexterity Impairments: Accessibility and Usability Study (Preprint)
BACKGROUND Mobile health systems have been shown to be useful in supporting self-management by promoting adherence to schedules and longitudinal health interventions, especially in people with disabilities. The Interactive Mobile Health and Rehabilitation (iMHere) system was developed to empower people with disabilities and those with chronic conditions with supports needed for self-management and independent living. Since the first iteration of the iMHere 1.0 app, several studies have evaluated the accessibility and usability of the system. Potential opportunities to improve and simplify the user interface were identified, and the iMHere modules were redesigned accordingly. OBJECTIVE In this study, we aim to evaluate the usability of the redesigned modules within the iMHere 1.0 app. METHODS We evaluated the original and redesigned iMHere modules—MyMeds and SkinCare. The Purdue Pegboard Test was administered to assess the participants’ dexterity levels. Participants were then asked to perform a set of tasks using both the original and redesigned MyMeds and SkinCare modules to assess their efficiency and effectiveness. Usability was measured using the Telehealth Usability Questionnaire to evaluate 10 new accessibility features that were added to the redesigned app. Participants were also asked which version they preferred. RESULTS In total, 24 participants with disabilities and varying degrees of dexterity impairments completed the entire study protocol. Participants displayed improved efficiency and effectiveness when using the redesigned modules compared with the original modules. The participants also reported improved usability and preferred the redesigned modules. CONCLUSIONS This study demonstrated that the iMHere system became more efficient, effective, and usable for individuals with dexterity impairments after redesigning it according to user-centered principles.
- 23 August 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessUser-Centered Design to Enhance mHealth Systems for Individuals With Dexterity Impairments: Accessibility and Usability Study (Preprint)
BACKGROUND Mobile health systems have been shown to be useful in supporting self-management by promoting adherence to schedules and longitudinal health interventions, especially in people with disabilities. The Interactive Mobile Health and Rehabilitation (iMHere) system was developed to empower people with disabilities and those with chronic conditions with supports needed for self-management and independent living. Since the first iteration of the iMHere 1.0 app, several studies have evaluated the accessibility and usability of the system. Potential opportunities to improve and simplify the user interface were identified, and the iMHere modules were redesigned accordingly. OBJECTIVE In this study, we aim to evaluate the usability of the redesigned modules within the iMHere 1.0 app. METHODS We evaluated the original and redesigned iMHere modules—MyMeds and SkinCare. The Purdue Pegboard Test was administered to assess the participants’ dexterity levels. Participants were then asked to perform a set of tasks using both the original and redesigned MyMeds and SkinCare modules to assess their efficiency and effectiveness. Usability was measured using the Telehealth Usability Questionnaire to evaluate 10 new accessibility features that were added to the redesigned app. Participants were also asked which version they preferred. RESULTS In total, 24 participants with disabilities and varying degrees of dexterity impairments completed the entire study protocol. Participants displayed improved efficiency and effectiveness when using the redesigned modules compared with the original modules. The participants also reported improved usability and preferred the redesigned modules. CONCLUSIONS This study demonstrated that the iMHere system became more efficient, effective, and usable for individuals with dexterity impairments after redesigning it according to user-centered principles.
- Open Access
- 8 January 2019
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 7 (1) , e202
An mHealth App for Users with Dexterity Impairments: Accessibility Study
Background: A mobile health (mHealth) system called iMHere (interactive mobile health and rehabilitation) was developed to support individuals with chronic conditions and disability in their self-management regimens. The initial design of iMHere, however, lacked sufficient accessibility for users with a myriad of dexterity impairments. The accessibility of self-management apps is essential in ensuring usability. Objective: This study aims to increase the usability of the iMHere system for users with dexterity impairments by increasing the app’s accessibility. Methods: We targeted the accessibility redesign by focusing on the physical presentation and the navigability of the iMHere apps. Six participants presenting with dexterity impairments were included in the usability study of the original and redesigned apps. Results: We observed a lower number of touches needed to complete tasks (P=.09) and time to complete individual tasks (P=.06) with the redesigned app than with the original app; a significantly lower time for users to complete all tasks (P=.006); and a significantly lower error rate (P=.01) with the redesigned app than with the original app. In fact, no errors occurred with use of the redesigned app. Participant-reported overall average usability of the redesigned app (P=.007) and usability of individual modules (P<.001) were significantly higher than that of the original app due mostly to better ease of use and learnability, interface quality, and reliability. Conclusions: Improved usability was achieved using a redesigned app. This study offers insight into the importance of personalization in enhancing the accessibility and also identifies strategies for improving usability in app development.
- 8 January 2019
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 7 (1) , e202
Open AccessAn mHealth App for Users with Dexterity Impairments: Accessibility Study
Background: A mobile health (mHealth) system called iMHere (interactive mobile health and rehabilitation) was developed to support individuals with chronic conditions and disability in their self-management regimens. The initial design of iMHere, however, lacked sufficient accessibility for users with a myriad of dexterity impairments. The accessibility of self-management apps is essential in ensuring usability. Objective: This study aims to increase the usability of the iMHere system for users with dexterity impairments by increasing the app’s accessibility. Methods: We targeted the accessibility redesign by focusing on the physical presentation and the navigability of the iMHere apps. Six participants presenting with dexterity impairments were included in the usability study of the original and redesigned apps. Results: We observed a lower number of touches needed to complete tasks (P=.09) and time to complete individual tasks (P=.06) with the redesigned app than with the original app; a significantly lower time for users to complete all tasks (P=.006); and a significantly lower error rate (P=.01) with the redesigned app than with the original app. In fact, no errors occurred with use of the redesigned app. Participant-reported overall average usability of the redesigned app (P=.007) and usability of individual modules (P<.001) were significantly higher than that of the original app due mostly to better ease of use and learnability, interface quality, and reliability. Conclusions: Improved usability was achieved using a redesigned app. This study offers insight into the importance of personalization in enhancing the accessibility and also identifies strategies for improving usability in app development.
- Open Access
- 29 January 2018
- Published by JMIR Publications Inc. in JMIR Preprints
An mHealth App for Users with Dexterity Impairments: Accessibility Study (Preprint)
BACKGROUND A mobile health (mHealth) system called iMHere (interactive mobile health and rehabilitation) was developed to support individuals with chronic conditions and disability in their self-management regimens. The initial design of iMHere, however, lacked sufficient accessibility for users with a myriad of dexterity impairments. The accessibility of self-management apps is essential in ensuring usability. OBJECTIVE This study aims to increase the usability of the iMHere system for users with dexterity impairments by increasing the app’s accessibility. METHODS We targeted the accessibility redesign by focusing on the physical presentation and the navigability of the iMHere apps. Six participants presenting with dexterity impairments were included in the usability study of the original and redesigned apps. RESULTS We observed a lower number of touches needed to complete tasks (P=.09) and time to complete individual tasks (P=.06) with the redesigned app than with the original app; a significantly lower time for users to complete all tasks (P=.006); and a significantly lower error rate (P=.01) with the redesigned app than with the original app. In fact, no errors occurred with use of the redesigned app. Participant-reported overall average usability of the redesigned app (P=.007) and usability of individual modules (P<.001) were significantly higher than that of the original app due mostly to better ease of use and learnability, interface quality, and reliability. CONCLUSIONS Improved usability was achieved using a redesigned app. This study offers insight into the importance of personalization in enhancing the accessibility and also identifies strategies for improving usability in app development.
- 29 January 2018
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessAn mHealth App for Users with Dexterity Impairments: Accessibility Study (Preprint)
BACKGROUND A mobile health (mHealth) system called iMHere (interactive mobile health and rehabilitation) was developed to support individuals with chronic conditions and disability in their self-management regimens. The initial design of iMHere, however, lacked sufficient accessibility for users with a myriad of dexterity impairments. The accessibility of self-management apps is essential in ensuring usability. OBJECTIVE This study aims to increase the usability of the iMHere system for users with dexterity impairments by increasing the app’s accessibility. METHODS We targeted the accessibility redesign by focusing on the physical presentation and the navigability of the iMHere apps. Six participants presenting with dexterity impairments were included in the usability study of the original and redesigned apps. RESULTS We observed a lower number of touches needed to complete tasks (P=.09) and time to complete individual tasks (P=.06) with the redesigned app than with the original app; a significantly lower time for users to complete all tasks (P=.006); and a significantly lower error rate (P=.01) with the redesigned app than with the original app. In fact, no errors occurred with use of the redesigned app. Participant-reported overall average usability of the redesigned app (P=.007) and usability of individual modules (P<.001) were significantly higher than that of the original app due mostly to better ease of use and learnability, interface quality, and reliability. CONCLUSIONS Improved usability was achieved using a redesigned app. This study offers insight into the importance of personalization in enhancing the accessibility and also identifies strategies for improving usability in app development.
- 8 July 2013
- Published by Global Science and Technology Forum
iMHere: mHealth Platform for Chronic Disease
- 8 July 2013
- Published by Global Science and Technology Forum
iMHere: mHealth Platform for Chronic Disease
- 1 January 2013
- Published by American Psychological Association (APA)
iMHere: mHealth Platform for Chronic Disease
- 1 January 2013
- Published by American Psychological Association (APA)
iMHere: mHealth Platform for Chronic Disease