Chang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chang Liu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Zhigang Zhang
3 shared publications- Dongfang Hu
School of Mechatronics Engineering, Henan University of Science and Technology, Luoyang, China
1 shared publication Haochuan Dong
School of Energy and Safety Engineering, Tianjin Chengjian University, Tianjin 300384, China
1 shared publicationHuan Gao
SPIC Central Research Institute Co., Ltd., Beijing 102209, China
1 shared publication- Ke Man
College of Civil Engineering, North China University of Technology, Beijing 100144, China
1 shared publication Xueli Liu
Tianjin Dadongyang Investment and Development Limited Company, Tianjin 300000, China
1 shared publication
Latest Publications
- Open Access
- 1 July 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 804 (4) , 042061
Applicability Analysis of Pre-cracked Material for SHPB during the High-level Radioactive Waste Geo-disposal
According to the national nuclear power plan, the high-level radioactive waste should be disposed safety and effectively. And the deep geological disposal is the main way, which is influenced by the surrounding rock and soil, especially the physical and mechanical properties. Currently, the SHPB is mature equipment for the material’s dynamic testing. It is mainly used to load the entire specimen, however, the specimen with the pre-crack is less used. Firstly, it should satisfy two hypotheses, i.e. the one dimension stress wave and the stress equalization when using the SHPB to measure the mechanics characteristics of the material, especially for the pre-cracked specimen. Then, from the point of stress equalization along the specimen, emphasize the importance of the dynamic force equilibrium during the testing data processing. Finally, the SHPB testing system could also be applied to the pre-cracked specimen has been proposed.
- 1 July 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 804 (4) , 042061
Open AccessApplicability Analysis of Pre-cracked Material for SHPB during the High-level Radioactive Waste Geo-disposal
According to the national nuclear power plan, the high-level radioactive waste should be disposed safety and effectively. And the deep geological disposal is the main way, which is influenced by the surrounding rock and soil, especially the physical and mechanical properties. Currently, the SHPB is mature equipment for the material’s dynamic testing. It is mainly used to load the entire specimen, however, the specimen with the pre-crack is less used. Firstly, it should satisfy two hypotheses, i.e. the one dimension stress wave and the stress equalization when using the SHPB to measure the mechanics characteristics of the material, especially for the pre-cracked specimen. Then, from the point of stress equalization along the specimen, emphasize the importance of the dynamic force equilibrium during the testing data processing. Finally, the SHPB testing system could also be applied to the pre-cracked specimen has been proposed.
- 1 December 2019
- Published by Elsevier in Renewable Energy
- Vol. 143, 1687-1697
Thermal response of wall implanted with heat pipes: Experimental analysis
- 1 December 2019
- Published by Elsevier in Renewable Energy
- Vol. 143, 1687-1697
Thermal response of wall implanted with heat pipes: Experimental analysis
- 20 March 2019
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 25 (4) , 504-513
Study of the thermal performance of a new type of floor heating and resulting indoor thermal comfort
The new type water floor (NTWF) is a device that combines the heating function with interior decoration to effectively supply heat indoors through low-temperature hot water circulating in the channels. This paper investigates the thermal performance of the NTWF and indoor thermal comfort experimentally and performs a numerical simulation. The experimental results indicate that two groups in parallel with 8 channels provide the optimal combination, and the indoor temperature can be maintained within the range from 19.4 °C to 24.9 °C in different operating conditions. Under the premise of meeting the heating demand, the average supply water temperature of the NTWF is 3 °C∼7 °C lower than that of a conventional floor. The simulation results show that the PMV for the indoor environment is -0.19, and only 6.2% of the occupants feel discomfort. In conclusion, the NTWF can improve the indoor thermal comfort effectively with low energy consumption and a short construction period. It has excellent prospects for future development in practical engineering.
- 20 March 2019
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 25 (4) , 504-513
Study of the thermal performance of a new type of floor heating and resulting indoor thermal comfort
The new type water floor (NTWF) is a device that combines the heating function with interior decoration to effectively supply heat indoors through low-temperature hot water circulating in the channels. This paper investigates the thermal performance of the NTWF and indoor thermal comfort experimentally and performs a numerical simulation. The experimental results indicate that two groups in parallel with 8 channels provide the optimal combination, and the indoor temperature can be maintained within the range from 19.4 °C to 24.9 °C in different operating conditions. Under the premise of meeting the heating demand, the average supply water temperature of the NTWF is 3 °C∼7 °C lower than that of a conventional floor. The simulation results show that the PMV for the indoor environment is -0.19, and only 6.2% of the occupants feel discomfort. In conclusion, the NTWF can improve the indoor thermal comfort effectively with low energy consumption and a short construction period. It has excellent prospects for future development in practical engineering.
- 4 February 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 151, 486-494
Optimisation of a wall implanted with heat pipes and applicability analysis in areas without district heating
- 4 February 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 151, 486-494
Optimisation of a wall implanted with heat pipes and applicability analysis in areas without district heating
- Open Access
- 7 September 2018
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 10 (9)
Analysis for the heat transfer of fully tempered vacuum glazing based on the thermal resistance model and finite element model
The fully tempered vacuum glazing, consisting of two fully tempered glass plates detached through a limited vacuum medium (below 0.01 Pa), is presented. The heat transfer through fully tempered vacuum glazing is complex, including heat conduction, thermal radiation, and convection. To analyze heat conduction through a stainless steel support ball, the thermal resistance of the support ball is established based on Hertzian contact model. And the total thermal resistance of the unit cell with one support ball is defined. The three-dimensional finite element model for a center unit cell of fully tempered vacuum glazing is simulated to validate the result of the total thermal resistance. The simulation transmission U-values are 0.26 W/m2 K. Meanwhile, the simulation transmission U-values of entire fully tempered vacuum glazing are 0.84 W/m2 K without frame insulation.
- 7 September 2018
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 10 (9)
Open AccessAnalysis for the heat transfer of fully tempered vacuum glazing based on the thermal resistance model and finite element model
The fully tempered vacuum glazing, consisting of two fully tempered glass plates detached through a limited vacuum medium (below 0.01 Pa), is presented. The heat transfer through fully tempered vacuum glazing is complex, including heat conduction, thermal radiation, and convection. To analyze heat conduction through a stainless steel support ball, the thermal resistance of the support ball is established based on Hertzian contact model. And the total thermal resistance of the unit cell with one support ball is defined. The three-dimensional finite element model for a center unit cell of fully tempered vacuum glazing is simulated to validate the result of the total thermal resistance. The simulation transmission U-values are 0.26 W/m2 K. Meanwhile, the simulation transmission U-values of entire fully tempered vacuum glazing are 0.84 W/m2 K without frame insulation.