Khan Mahmud Amanat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Khan Mahmud Amanat has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- A. K. M. Jahangir Alam
Engineering Office, Bangladesh University of Engineering and Technology (BUET), Dhaka-1000, Bangladesh
1 shared publication - Dipan Dhali
Department of Civil Engineering, Bangladesh University of Engineering and Technology
1 shared publication - Iftesham Bashar
Department of Civil Engineering Bangladesh University of Engineering and Technology Dhaka Bangladesh buet.ac.bd
1 shared publication - Israt Jahan
Department of Pathology, Faculty of Agriculture, Bangladesh Agricultural University, Mymensingh- 2202, Bangladesh
1 shared publication - Mehsam Tanzim Khan
Department of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208, USA
1 shared publication - Mohammad Asad Hussain
Institute of Water and Flood Management (IWFM), Bangladesh University of Engineering and Technology (BUET), Dhaka, Bangladesh
1 shared publication
Latest Publications
- 16 April 2026
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 33 (1)
Comparison of concrete core testing methods based on destructive test of RC column samples
- 16 April 2026
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 33 (1)
Comparison of concrete core testing methods based on destructive test of RC column samples
- Open Access
- 1 January 2026
- Published by Wiley in Advances in Civil Engineering
- Vol. 2026 (1)
Comparison of Codes in Predicting Compression Capacity of Welded High‐Strength I‐Shaped Sections
This study presents a comprehensive investigation into the axial load‐bearing capacity of welded high‐strength steel (HSS) I‐shaped sections subjected to concentric compressive loading. Advanced nonlinear finite element (FE) simulations incorporating experimentally measured geometric imperfections, welding‐induced residual stresses, and nonlinear stress–strain behavior were developed and validated against previously reported experimental data covering a wide range of nominal yield stresses, cross‐sectional dimensions, and member slenderness ratios. The FE models demonstrated excellent predictive capability, when compared with experimental results. The experimental results were also employed to evaluate the predictive performance of 11 major international design code provisions: ASCE 10‐15, AISC 360‐22, AASHTO LRFD (2024), SSRC Guide, Eurocode EN 1993‐1‐1, BS 5950‐1, Russian SP 16.13330, Australian AS 4100, Indian IS 800, Chinese GB 50017‐2017, and the Japanese Code through comprehensive statistical analyses. The code predicted capacities showed some variations, with correlation coefficients between 0.92 and 0.95. IS 800, Eurocode 3, and the Chinese code were most conservative, underpredicting capacities by 20%–25%; AISC 360‐22, AASHTO, BS 5950, AS 4100, the Japanese code, and the Russian code were moderately conservative (9%–15%); ASCE 10‐15 and SSRC showed the closest agreement with test results. Classification of specimens by slenderness and steel grade revealed that prediction accuracy is governed primarily by each code’s inherent design philosophy rather than member slenderness, while conservatism increases systematically with steel grade, from conventional HSS (Q420–Q460) to advanced HSS (Q550–Q960). Compactness checks confirmed all specimens were non‐slender, indicating that capacity discrepancies arise from global buckling behavior rather than local plate element instability. These findings provide a unified, cross‐code benchmarking framework and practical guidance for engineers selecting design provisions for welded HSS I‐section columns.
- 1 January 2026
- Published by Wiley in Advances in Civil Engineering
- Vol. 2026 (1)
Open AccessComparison of Codes in Predicting Compression Capacity of Welded High‐Strength I‐Shaped Sections
This study presents a comprehensive investigation into the axial load‐bearing capacity of welded high‐strength steel (HSS) I‐shaped sections subjected to concentric compressive loading. Advanced nonlinear finite element (FE) simulations incorporating experimentally measured geometric imperfections, welding‐induced residual stresses, and nonlinear stress–strain behavior were developed and validated against previously reported experimental data covering a wide range of nominal yield stresses, cross‐sectional dimensions, and member slenderness ratios. The FE models demonstrated excellent predictive capability, when compared with experimental results. The experimental results were also employed to evaluate the predictive performance of 11 major international design code provisions: ASCE 10‐15, AISC 360‐22, AASHTO LRFD (2024), SSRC Guide, Eurocode EN 1993‐1‐1, BS 5950‐1, Russian SP 16.13330, Australian AS 4100, Indian IS 800, Chinese GB 50017‐2017, and the Japanese Code through comprehensive statistical analyses. The code predicted capacities showed some variations, with correlation coefficients between 0.92 and 0.95. IS 800, Eurocode 3, and the Chinese code were most conservative, underpredicting capacities by 20%–25%; AISC 360‐22, AASHTO, BS 5950, AS 4100, the Japanese code, and the Russian code were moderately conservative (9%–15%); ASCE 10‐15 and SSRC showed the closest agreement with test results. Classification of specimens by slenderness and steel grade revealed that prediction accuracy is governed primarily by each code’s inherent design philosophy rather than member slenderness, while conservatism increases systematically with steel grade, from conventional HSS (Q420–Q460) to advanced HSS (Q550–Q960). Compactness checks confirmed all specimens were non‐slender, indicating that capacity discrepancies arise from global buckling behavior rather than local plate element instability. These findings provide a unified, cross‐code benchmarking framework and practical guidance for engineers selecting design provisions for welded HSS I‐section columns.
- Open Access
- 1 January 2025
- Published by Wiley in Advances in Civil Engineering
- Vol. 2025 (1)
Vibrational Response of Solid RC Slab System Under Synchronized Multiperson Walking Excitation
Solid reinforced concrete (RC) floor systems have become susceptible to vibration from walking‐induced excitation due to the lightweight characteristics of concrete. This reduces the serviceability of the building in terms of occupant discomfort, adaptability to dynamic load, durability issues resulting from undesirable cracking, and service life. The present study evaluates the vibrational response of square solid RC slab panels supported on column line beams for synchronized multiperson walking. The study adopts a finite element (FE) methodology using linear modal time history analyses. The FE analyses model used for the study has been developed to replicate the response of a commercial space on an intermediate floor of a multistory building when subjected to synchronized multiperson walking excitation. The adopted methodology has been validated against past experimental results. A justification has also been established behind the walking and data acquisition parameters used for this study. A parametric study has been conducted to evaluate the response of the slab system for varying span lengths, slab thickness, and number of people. Peak acceleration responses obtained were then compared against different design guide limits for minimum slab thickness and allowable peak acceleration levels. The comparison revealed that existing design guide limits for minimum slab thickness might be insufficient to circumvent walking‐induced vibration discomfort. Based on the observations, revised minimum slab thickness was also proposed for different span lengths, which varied from 175 mm at 5 m to 225 mm at 9 m span for commercial spaces and 225 mm at 5 m to 350 mm at 9 m span for residential buildings. These findings will assist engineers in deciding the minimum slab thickness based on the span length, circumventing walking‐induced vibration discomfort.
- 1 January 2025
- Published by Wiley in Advances in Civil Engineering
- Vol. 2025 (1)
Open AccessVibrational Response of Solid RC Slab System Under Synchronized Multiperson Walking Excitation
Solid reinforced concrete (RC) floor systems have become susceptible to vibration from walking‐induced excitation due to the lightweight characteristics of concrete. This reduces the serviceability of the building in terms of occupant discomfort, adaptability to dynamic load, durability issues resulting from undesirable cracking, and service life. The present study evaluates the vibrational response of square solid RC slab panels supported on column line beams for synchronized multiperson walking. The study adopts a finite element (FE) methodology using linear modal time history analyses. The FE analyses model used for the study has been developed to replicate the response of a commercial space on an intermediate floor of a multistory building when subjected to synchronized multiperson walking excitation. The adopted methodology has been validated against past experimental results. A justification has also been established behind the walking and data acquisition parameters used for this study. A parametric study has been conducted to evaluate the response of the slab system for varying span lengths, slab thickness, and number of people. Peak acceleration responses obtained were then compared against different design guide limits for minimum slab thickness and allowable peak acceleration levels. The comparison revealed that existing design guide limits for minimum slab thickness might be insufficient to circumvent walking‐induced vibration discomfort. Based on the observations, revised minimum slab thickness was also proposed for different span lengths, which varied from 175 mm at 5 m to 225 mm at 9 m span for commercial spaces and 225 mm at 5 m to 350 mm at 9 m span for residential buildings. These findings will assist engineers in deciding the minimum slab thickness based on the span length, circumventing walking‐induced vibration discomfort.
- Open Access
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
Hydro-Structural Response of Complex Elevated Pile Cap Substructures to Strom Surge Impact by Smoothed Particle Hydrodynamics: Part 2: Model Results
This is the second article of a two-part series where the model validated in part 1 is extended to study the hydrodynamic response and group effect of elevated pile cap substructures to impulsive surge impact. Two conventional grids (2×2, 2×3 array-layout) and a hexagonal pile arrangement under three submersion levels are considered in studying the pile group effect on hydrodynamic forcing mechanism, flow characteristics, and factors governing pressure variability. The uplift thrust on the pile cap was found to be dependent on the surge fluid mass, incident velocity, and vertical distance between the surge breaking point and cap bottom. At impulsive impact, gridded pile arrangement offered greater resistance to incident surge flow. In reference to free flow condition, hexagonal layout can reduce the average flow velocity by 8.22-19.76%, while for a gridded system, it is between 14.00%-23.52% depending on the submersion level. However, the reversed under quasi-steady state, where the hexagonal system showed greater flow resistance. The study also compared the numerical results to accepted offshore design standards, which were found to underestimate the pile’s group effect, specifically for complex hexagonal layouts. . Later, it proposes rationalized force diagrams to be applied in design of complex elevated structures.
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
Open AccessHydro-Structural Response of Complex Elevated Pile Cap Substructures to Strom Surge Impact by Smoothed Particle Hydrodynamics: Part 2: Model Results
This is the second article of a two-part series where the model validated in part 1 is extended to study the hydrodynamic response and group effect of elevated pile cap substructures to impulsive surge impact. Two conventional grids (2×2, 2×3 array-layout) and a hexagonal pile arrangement under three submersion levels are considered in studying the pile group effect on hydrodynamic forcing mechanism, flow characteristics, and factors governing pressure variability. The uplift thrust on the pile cap was found to be dependent on the surge fluid mass, incident velocity, and vertical distance between the surge breaking point and cap bottom. At impulsive impact, gridded pile arrangement offered greater resistance to incident surge flow. In reference to free flow condition, hexagonal layout can reduce the average flow velocity by 8.22-19.76%, while for a gridded system, it is between 14.00%-23.52% depending on the submersion level. However, the reversed under quasi-steady state, where the hexagonal system showed greater flow resistance. The study also compared the numerical results to accepted offshore design standards, which were found to underestimate the pile’s group effect, specifically for complex hexagonal layouts. . Later, it proposes rationalized force diagrams to be applied in design of complex elevated structures.
- 1 April 2020
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Construction Materials
- Vol. 173 (2) , 79-88
Splitting tensile strength of natural aggregates, recycled aggregates and brick chips concrete
This paper presents an experimental study and analysis of the splitting tensile strength (ft) and relationship between splitting tensile strength and compressive strength (f′c) of concrete made of three types of coarse aggregates; namely crushed brick chips (CBC), natural stone aggregates (SA) and recycled concrete aggregates (RCA). Four concrete mixtures with different target strengths were prepared and for each mixture, six cylindrical samples were subjected to split-cylinder tests and another six cylindrical samples were subjected to compression tests at 28 d. Raw test data were then analysed according to the American Concrete Institute (ACI) 214 and the average tensile strength obtained was compared with the relevant compressive strength based on statistical curve fitting. This study shows that while the ACI equation and equations suggested by other authors for the correlation between splitting tensile strength and compressive strength are applicable for SA concrete, they are not quite applicable for concrete made with CBC or RCA. Thus, new empirical equations are derived to predict the splitting tensile strength from concrete compressive strength for concrete made with CBC and RCA.
- 1 April 2020
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Construction Materials
- Vol. 173 (2) , 79-88
Splitting tensile strength of natural aggregates, recycled aggregates and brick chips concrete
This paper presents an experimental study and analysis of the splitting tensile strength (ft) and relationship between splitting tensile strength and compressive strength (f′c) of concrete made of three types of coarse aggregates; namely crushed brick chips (CBC), natural stone aggregates (SA) and recycled concrete aggregates (RCA). Four concrete mixtures with different target strengths were prepared and for each mixture, six cylindrical samples were subjected to split-cylinder tests and another six cylindrical samples were subjected to compression tests at 28 d. Raw test data were then analysed according to the American Concrete Institute (ACI) 214 and the average tensile strength obtained was compared with the relevant compressive strength based on statistical curve fitting. This study shows that while the ACI equation and equations suggested by other authors for the correlation between splitting tensile strength and compressive strength are applicable for SA concrete, they are not quite applicable for concrete made with CBC or RCA. Thus, new empirical equations are derived to predict the splitting tensile strength from concrete compressive strength for concrete made with CBC and RCA.
- 1 January 2015
- Published by Inderscience Publishers in International Journal of Structural Engineering
- Vol. 6 (3) , 280
Effect of column size on punching shear behaviour of multi panel RC flat plate
In flat plate floor system, due to variation of slab panel and loading pattern, various sizes of column within same thickness of slab are designed. Variation of column size is also used in high rise building in different floors within same type flat plate. In both cases punching shear capacity of flat plate is calculated by the same type of code equation. Code equations for punching strength of concrete do not consider column size or dimension as a parameter. In the present study, the effect of column size in punching shear behaviour of flat plate is identified by numerical finite element study of multi-panel flat plate. The load carrying capacity of multi panel flat plate having various column sizes is also compared with various codes of prediction. Normalised punching shear strength decreases with increase of column size is obtained in this study.
- 1 January 2015
- Published by Inderscience Publishers in International Journal of Structural Engineering
- Vol. 6 (3) , 280
Effect of column size on punching shear behaviour of multi panel RC flat plate
In flat plate floor system, due to variation of slab panel and loading pattern, various sizes of column within same thickness of slab are designed. Variation of column size is also used in high rise building in different floors within same type flat plate. In both cases punching shear capacity of flat plate is calculated by the same type of code equation. Code equations for punching strength of concrete do not consider column size or dimension as a parameter. In the present study, the effect of column size in punching shear behaviour of flat plate is identified by numerical finite element study of multi-panel flat plate. The load carrying capacity of multi panel flat plate having various column sizes is also compared with various codes of prediction. Normalised punching shear strength decreases with increase of column size is obtained in this study.