Melissa Weissner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Melissa Weissner has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Helen Ullrich
Zentrum für Kardiologie, University Hospital Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany and German Center for Cardiac and Vascular Research (DZHK), Standort Rhein-Main
3 shared publications - Remzi Anadol
Kardiologie I, Zentrum für Kardiologie, University Medical Center Mainz and Deutsches Zentrum für Herz und Kreislauf Forschung, Standort Rhein-Main 55131 Mainz, Germany
3 shared publications - Thomas Münzel
University Medical Center Mainz, Johannes Gutenberg University, Mainz, Germany
3 shared publications - Tommaso Gori
Kardiologie I, Center for Cardiology, University Medical Centre Mainz and DZHK Standort Rhein-Main , Mainz
3 shared publications - Alberto Polimeni
Department of Pharmacy, Health and Nutritional Sciences, University of Calabria, 87036 Rende, Italy
2 shared publications - Christian W. Hamm
Department of Medicine I, Cardiology and Angiology, University Hospital Giessen and Marburg, 35392 Giessen, Germany
1 shared publication
Latest Publications
- Open Access
- 27 April 2019
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 8 (5) , 580
Incidental Finding of Strut Malapposition Is a Predictor of Late and Very Late Thrombosis in Coronary Bioresorbable Scaffolds
Malapposition is a common finding in stent and scaffold thrombosis (ScT). Evidence from studies with prospective follow-up, however, is scarce. We hypothesized that incidental observations of strut malapposition might be predictive of late ScT during subsequent follow-up. One hundred ninety-seven patients were enrolled in a multicentre registry with prospective follow-up. Optical coherence tomography (OCT), performed in an elective setting, was available in all at 353 (0–376) days after bioresorbable scaffold (BRS) implantation. Forty-four patients showed evidence of malapposition that was deemed not worthy of intervention. Malapposition was not associated with any clinical or procedural parameter except for a higher implantation pressure (p = 0.0008). OCT revealed that malapposition was associated with larger vessel size, less eccentricity (all p < 0.01), and a tendency for more uncovered struts (p = 0.06). Late or very late ScT was recorded in seven of these patients 293 (38–579) days after OCT. OCT-diagnosed malapposition was a predictor of late and very late scaffold thrombosis (p < 0.001) that was independent of the timing of diagnosis. We provide evidence that an incidental finding of malapposition—regardless of the timing of diagnosis of the malapposition—during an elective exam is a predictor of late and very late ScT. Our data provide a rationale to consider prolonged dual antiplatelet therapy if strut malapposition is observed.
- 27 April 2019
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 8 (5) , 580
Open AccessIncidental Finding of Strut Malapposition Is a Predictor of Late and Very Late Thrombosis in Coronary Bioresorbable Scaffolds
Malapposition is a common finding in stent and scaffold thrombosis (ScT). Evidence from studies with prospective follow-up, however, is scarce. We hypothesized that incidental observations of strut malapposition might be predictive of late ScT during subsequent follow-up. One hundred ninety-seven patients were enrolled in a multicentre registry with prospective follow-up. Optical coherence tomography (OCT), performed in an elective setting, was available in all at 353 (0–376) days after bioresorbable scaffold (BRS) implantation. Forty-four patients showed evidence of malapposition that was deemed not worthy of intervention. Malapposition was not associated with any clinical or procedural parameter except for a higher implantation pressure (p = 0.0008). OCT revealed that malapposition was associated with larger vessel size, less eccentricity (all p < 0.01), and a tendency for more uncovered struts (p = 0.06). Late or very late ScT was recorded in seven of these patients 293 (38–579) days after OCT. OCT-diagnosed malapposition was a predictor of late and very late scaffold thrombosis (p < 0.001) that was independent of the timing of diagnosis. We provide evidence that an incidental finding of malapposition—regardless of the timing of diagnosis of the malapposition—during an elective exam is a predictor of late and very late ScT. Our data provide a rationale to consider prolonged dual antiplatelet therapy if strut malapposition is observed.
- Open Access
- 15 January 2019
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 8 (1) , 93
Procedural Predictors for Bioresorbable Vascular Scaffold Thrombosis: Analysis of the Individual Components of the “PSP” Technique
The technique used at the time of implantation has a central role in determining the risk of thrombosis in bioresorbable vascular scaffolds (BRS). Different definitions of the “optimal” implantation technique exist, however. The impact of individual procedural characteristics on the risk of scaffold thrombosis (ScT) was evaluated in a single-center observational study that enrolled 657 patients (79% males, mean age 63 ± 12 years) with 763 lesions who received a total of 925 BRS for de novo lesions. During a median 1076 (762–1206) days’ follow-up there were 28 cases of thrombosis. Independent predictors of ScT included the use of predilatation balloons bigger than the nominal BRS diameter (hazard ratio (HR) = 0.4 (0.16–0.98), p = 0.04), sizing (implantation in vessels with reference vessel diameter >3.5 mm or p = 0.0002) and the degree of vessel expansion (ratio of minimum lumen to reference vessel diameter, HR: 0.005 (0.0001–0.23), p = 0.007). In addition, a mild BRS oversizing (final BRS diameter to vessel diameter 1.14–1.28) was associated with a lower thrombosis risk, whereas undersizing and more severe oversizing (final BRS diameter to vessel diameter 1.35, respectively) were associated with an increased risk of ScT (HR = 0.13 (0.02–0.59), p = 0.0007). In conclusion, different components of the “optimal” technique have different impacts on the risk of BRS thrombosis. Besides predilatation with a balloon larger than the BRS diameter, correct vessel size selection and a mild to moderate oversizing appear to be protective.
- 15 January 2019
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 8 (1) , 93
Open AccessProcedural Predictors for Bioresorbable Vascular Scaffold Thrombosis: Analysis of the Individual Components of the “PSP” Technique
The technique used at the time of implantation has a central role in determining the risk of thrombosis in bioresorbable vascular scaffolds (BRS). Different definitions of the “optimal” implantation technique exist, however. The impact of individual procedural characteristics on the risk of scaffold thrombosis (ScT) was evaluated in a single-center observational study that enrolled 657 patients (79% males, mean age 63 ± 12 years) with 763 lesions who received a total of 925 BRS for de novo lesions. During a median 1076 (762–1206) days’ follow-up there were 28 cases of thrombosis. Independent predictors of ScT included the use of predilatation balloons bigger than the nominal BRS diameter (hazard ratio (HR) = 0.4 (0.16–0.98), p = 0.04), sizing (implantation in vessels with reference vessel diameter >3.5 mm or p = 0.0002) and the degree of vessel expansion (ratio of minimum lumen to reference vessel diameter, HR: 0.005 (0.0001–0.23), p = 0.007). In addition, a mild BRS oversizing (final BRS diameter to vessel diameter 1.14–1.28) was associated with a lower thrombosis risk, whereas undersizing and more severe oversizing (final BRS diameter to vessel diameter 1.35, respectively) were associated with an increased risk of ScT (HR = 0.13 (0.02–0.59), p = 0.0007). In conclusion, different components of the “optimal” technique have different impacts on the risk of BRS thrombosis. Besides predilatation with a balloon larger than the BRS diameter, correct vessel size selection and a mild to moderate oversizing appear to be protective.
- Open Access
- 10 May 2018
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 18 (1) , 1-10
Three-years outcomes of diabetic patients treated with coronary bioresorbable scaffolds
Diabetes is among the strongest predictors of outcome after coronary artery stenting and the incidence of negative outcomes is still high in this specific group. Data of long-term outcomes comparing diabetic patients with non-diabetic patients treated with bioresorbable scaffolds are still incomplete. This work evaluates the long-term outcomes after implantation of a coronary bioresorbable scaffold (BRS) in diabetic patients compared to non-diabetics. Patients who received at least one Absorb BRS in the time of May 2012 to December 2014 were enrolled into this single-center registry. Quantitative coronary angiography (QCA) was performed. Six hundred fifty seven patients including 138 patients (21%, mean age 65 ± 11, 78% male) with diabetes were enrolled. Patients in the diabetic group were significantly older, were more likely to suffer from hypertension and hyperlipidemia and had more often a prior stroke or TIA as well as a reduced renal function (all P < 0.05). The initial stenosis was less severe in the diabetic group (74.8% vs. 79.6%, P = 0.036), but the residual stenosis after BRS implantation exceeded that of the control group (16.7% vs. 13.8%, P = 0.006). History of diabetes had no impact on the incidence of events within one year after BRS implantation. Beyond 1 year, diabetic patients had a higher incidence of cardiovascular death (6.9 vs. 1.4%, HR:5.37 [1.33–21.71], P = 0.001), scaffold restenosis (17.6 vs. 7.8%, HR:3.56 [1.40–9.05], P < 0.0001) and target lesion revascularization (P = 0.016). These results were confirmed in the propensity score analysis. In both diabetics and non-diabetics, there was a strong association (HR:18.6 [4.7–73.3]) between the risk of restenosis and the technique used at implantation; in contrast, the impact of vessel size was more manifest in non-diabetics than in diabetic patients, and an increased risk of restenosis was demonstrated for both large and small vessels. As for metal stents, beyond one year after implantation, diabetes was associated with an increased incidence of scaffold restenosis and related outcomes. This negative impact of diabetes was reset when an optimal implantation technique was used.
- 10 May 2018
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 18 (1) , 1-10
Open AccessThree-years outcomes of diabetic patients treated with coronary bioresorbable scaffolds
Diabetes is among the strongest predictors of outcome after coronary artery stenting and the incidence of negative outcomes is still high in this specific group. Data of long-term outcomes comparing diabetic patients with non-diabetic patients treated with bioresorbable scaffolds are still incomplete. This work evaluates the long-term outcomes after implantation of a coronary bioresorbable scaffold (BRS) in diabetic patients compared to non-diabetics. Patients who received at least one Absorb BRS in the time of May 2012 to December 2014 were enrolled into this single-center registry. Quantitative coronary angiography (QCA) was performed. Six hundred fifty seven patients including 138 patients (21%, mean age 65 ± 11, 78% male) with diabetes were enrolled. Patients in the diabetic group were significantly older, were more likely to suffer from hypertension and hyperlipidemia and had more often a prior stroke or TIA as well as a reduced renal function (all P < 0.05). The initial stenosis was less severe in the diabetic group (74.8% vs. 79.6%, P = 0.036), but the residual stenosis after BRS implantation exceeded that of the control group (16.7% vs. 13.8%, P = 0.006). History of diabetes had no impact on the incidence of events within one year after BRS implantation. Beyond 1 year, diabetic patients had a higher incidence of cardiovascular death (6.9 vs. 1.4%, HR:5.37 [1.33–21.71], P = 0.001), scaffold restenosis (17.6 vs. 7.8%, HR:3.56 [1.40–9.05], P < 0.0001) and target lesion revascularization (P = 0.016). These results were confirmed in the propensity score analysis. In both diabetics and non-diabetics, there was a strong association (HR:18.6 [4.7–73.3]) between the risk of restenosis and the technique used at implantation; in contrast, the impact of vessel size was more manifest in non-diabetics than in diabetic patients, and an increased risk of restenosis was demonstrated for both large and small vessels. As for metal stents, beyond one year after implantation, diabetes was associated with an increased incidence of scaffold restenosis and related outcomes. This negative impact of diabetes was reset when an optimal implantation technique was used.