Ashish Avachat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ashish Avachat has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Seth Kilby
Idaho National Laboratory, Idaho Falls, USA
6 shared publications - Hyoung Koo Lee
Missouri University of Science and Technology, 222 Fulton Hall 301 W. 14th St., Rolla, MO, 65401, USA
5 shared publications - Joseph Graham
Department of Nuclear Engineering and Radiation Science Missouri University of Science and Technology Rolla Missouri USA
4 shared publications - Jordan Fox3 shared publications
- Ayodeji Alajo
Missouri University of Science and Technology
2 shared publications Carlos H. C. Giraldo
The Department of Mining and Nuclear Engineering, Missouri University of Science and Technology, Rolla, Missouri
2 shared publications
Latest Publications
- Open Access
- 10 June 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1091
Prototyping pinhole collimators for imaging irradiated nuclear fuel
- 10 June 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1091
Open AccessPrototyping pinhole collimators for imaging irradiated nuclear fuel
- 2 December 2025
- Published by Elsevier in Radiation Measurements
- Vol. 191
Use of gamma-ray spectroscopy in thickness gauging of a complex-shaped lead shield
- 2 December 2025
- Published by Elsevier in Radiation Measurements
- Vol. 191
Use of gamma-ray spectroscopy in thickness gauging of a complex-shaped lead shield
- 26 December 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1072
Modeling and simulation study for the design of the Fuel Interrogation and Examination using Submersible Tomography Analysis Mk II instrument
- 26 December 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1072
Modeling and simulation study for the design of the Fuel Interrogation and Examination using Submersible Tomography Analysis Mk II instrument
- Open Access
- 3 April 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (8) , 085005
Investigating the robustness of a deep learning-based method for quantitative phase retrieval from propagation-based x-ray phase contrast measurements under laboratory conditions
Objective. Quantitative phase retrieval (QPR) in propagation-based x-ray phase contrast imaging of heterogeneous and structurally complicated objects is challenging under laboratory conditions due to partial spatial coherence and polychromaticity. A deep learning-based method (DLBM) provides a nonlinear approach to this problem while not being constrained by restrictive assumptions about object properties and beam coherence. The objective of this work is to assess a DLBM for its applicability under practical scenarios by evaluating its robustness and generalizability under typical experimental variations. Approach. Towards this end, an end-to-end DLBM was employed for QPR under laboratory conditions and its robustness was investigated across various system and object conditions. The robustness of the method was tested via varying propagation distances and its generalizability with respect to object structure and experimental data was also tested. Main results. Although the end-to-end DLBM was stable under the studied variations, its successful deployment was found to be affected by choices pertaining to data pre-processing, network training considerations and system modeling. Significance. To our knowledge, we demonstrated for the first time, the potential applicability of an end-to-end learning-based QPR method, trained on simulated data, to experimental propagation-based x-ray phase contrast measurements acquired under laboratory conditions with a commercial x-ray source and a conventional detector. We considered conditions of polychromaticity, partial spatial coherence, and high noise levels, typical to laboratory conditions. This work further explored the robustness of this method to practical variations in propagation distances and object structure with the goal of assessing its potential for experimental use. Such an exploration of any DLBM (irrespective of its network architecture) before practical deployment provides an understanding of its potential behavior under experimental settings.
- 3 April 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (8) , 085005
Open AccessInvestigating the robustness of a deep learning-based method for quantitative phase retrieval from propagation-based x-ray phase contrast measurements under laboratory conditions
Objective. Quantitative phase retrieval (QPR) in propagation-based x-ray phase contrast imaging of heterogeneous and structurally complicated objects is challenging under laboratory conditions due to partial spatial coherence and polychromaticity. A deep learning-based method (DLBM) provides a nonlinear approach to this problem while not being constrained by restrictive assumptions about object properties and beam coherence. The objective of this work is to assess a DLBM for its applicability under practical scenarios by evaluating its robustness and generalizability under typical experimental variations. Approach. Towards this end, an end-to-end DLBM was employed for QPR under laboratory conditions and its robustness was investigated across various system and object conditions. The robustness of the method was tested via varying propagation distances and its generalizability with respect to object structure and experimental data was also tested. Main results. Although the end-to-end DLBM was stable under the studied variations, its successful deployment was found to be affected by choices pertaining to data pre-processing, network training considerations and system modeling. Significance. To our knowledge, we demonstrated for the first time, the potential applicability of an end-to-end learning-based QPR method, trained on simulated data, to experimental propagation-based x-ray phase contrast measurements acquired under laboratory conditions with a commercial x-ray source and a conventional detector. We considered conditions of polychromaticity, partial spatial coherence, and high noise levels, typical to laboratory conditions. This work further explored the robustness of this method to practical variations in propagation distances and object structure with the goal of assessing its potential for experimental use. Such an exploration of any DLBM (irrespective of its network architecture) before practical deployment provides an understanding of its potential behavior under experimental settings.
- 10 October 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1045
Multi-modal tomographic imaging system for poolside characterization of nuclear test fuels: Design considerations and studies
- 10 October 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1045
Multi-modal tomographic imaging system for poolside characterization of nuclear test fuels: Design considerations and studies
- 1 June 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1001
Comparison of a semi-analytic variance reduction technique to classical Monte Carlo variance reduction techniques for high aspect ratio pencil beam collimators for emission tomography applications
- 1 June 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1001
Comparison of a semi-analytic variance reduction technique to classical Monte Carlo variance reduction techniques for high aspect ratio pencil beam collimators for emission tomography applications
- 16 March 2020
- Published by Radiation Research Society in Radiation Research
- Vol. 193 (5) , 497-504
Looking Inside a Prototype Compact X-Ray Tube Comprising CNT-Based Cold Cathode and Transmission-Type Anode
In this article, we offer a look inside our prototype compact X-ray tube by reporting on our findings when we experimentally studied it. We studied the prototype experimentally to characterize its primary components, i.e., carbon nanotube (CNT)-based cold cathode, electrostatic lens and transmission-type anode, and to validate our previous simulation studies. We characterized the CNT-based cold cathode by studying the relationship between the electron emission current and its control parameter, electron extraction voltage. This relationship, commonly known as the current-voltage characteristic, showed an exponential-like nature that is expected from the Fowler-Nordheim model for field emission. Next, we characterized the electrostatic lens by studying the effects of lens voltage on the focal spot size. Their relationship showed a “V” trend and corroborated that we can control the focal spot size by controlling the lens voltage. We then characterized the transmission-type anode of the prototype by studying its output X-ray energy spectra at different anode voltages. We could control the highest and the mean X-ray energies generated from the transmission-type anode using the anode voltage. For the same anode voltage and aluminum filtration, when we compared the Xray energy spectrum generated from the transmission-type anode with that of the conventional reflection-type anode, we observed that the two energy spectra agreed with each other.
- 16 March 2020
- Published by Radiation Research Society in Radiation Research
- Vol. 193 (5) , 497-504
Looking Inside a Prototype Compact X-Ray Tube Comprising CNT-Based Cold Cathode and Transmission-Type Anode
In this article, we offer a look inside our prototype compact X-ray tube by reporting on our findings when we experimentally studied it. We studied the prototype experimentally to characterize its primary components, i.e., carbon nanotube (CNT)-based cold cathode, electrostatic lens and transmission-type anode, and to validate our previous simulation studies. We characterized the CNT-based cold cathode by studying the relationship between the electron emission current and its control parameter, electron extraction voltage. This relationship, commonly known as the current-voltage characteristic, showed an exponential-like nature that is expected from the Fowler-Nordheim model for field emission. Next, we characterized the electrostatic lens by studying the effects of lens voltage on the focal spot size. Their relationship showed a “V” trend and corroborated that we can control the focal spot size by controlling the lens voltage. We then characterized the transmission-type anode of the prototype by studying its output X-ray energy spectra at different anode voltages. We could control the highest and the mean X-ray energies generated from the transmission-type anode using the anode voltage. For the same anode voltage and aluminum filtration, when we compared the Xray energy spectrum generated from the transmission-type anode with that of the conventional reflection-type anode, we observed that the two energy spectra agreed with each other.
- 21 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 66 (3) , 1525-1532
Particle-In-Cell Simulations of Electron Focusing for a Compact X-Ray Tube Comprising CNT-Based Electron Source and Transmission Type Anode
For real-time computed tomography (CT), a temporal resolution lower than 30 ms is required, which cannot be delivered by conventional CT architectures with a rotation gantry. Stationary CT architecture can achieve a temporal resolution lower than 30 ms by eliminating the physical rotation of the gantry and by electronically sweeping X-ray beams across the gantry. Stationary CT architecture utilizes two separate arrays, one for distributed X-ray sources and another for detectors. These individual X-ray sources are required to be compact, fast, and individually addressable in order to acquire 200+ projections for successful CT reconstruction and to achieve a temporal resolution lower than 30 ms. A compact X-ray tube that fits these requirements is being developed. The aim of this paper was to design an electrostatic electron focusing lens for the first-generation prototype compact X-ray tube primarily consisting of a carbon nanotube-based electron source and a transmission-type anode by studying the multiple variables that affect the focal spot size (FSS) and by comparing different types of electrostatic lenses with the help of simulations. This multivariable simulation study was conducted using an object-oriented particle-in-cell code, OOPIC PRO. The results of these simulations showed the following: Einzel lens can achieve the required FSS (lower than 1 mm); lens aperture, thickness, and location of the lens can be used as a coarse control over the FSS, whereas the lens potential can be used as a fine control; and the chromatic and spherical aberrations can be reduced if Einzel lens is used.
- 21 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 66 (3) , 1525-1532
Particle-In-Cell Simulations of Electron Focusing for a Compact X-Ray Tube Comprising CNT-Based Electron Source and Transmission Type Anode
For real-time computed tomography (CT), a temporal resolution lower than 30 ms is required, which cannot be delivered by conventional CT architectures with a rotation gantry. Stationary CT architecture can achieve a temporal resolution lower than 30 ms by eliminating the physical rotation of the gantry and by electronically sweeping X-ray beams across the gantry. Stationary CT architecture utilizes two separate arrays, one for distributed X-ray sources and another for detectors. These individual X-ray sources are required to be compact, fast, and individually addressable in order to acquire 200+ projections for successful CT reconstruction and to achieve a temporal resolution lower than 30 ms. A compact X-ray tube that fits these requirements is being developed. The aim of this paper was to design an electrostatic electron focusing lens for the first-generation prototype compact X-ray tube primarily consisting of a carbon nanotube-based electron source and a transmission-type anode by studying the multiple variables that affect the focal spot size (FSS) and by comparing different types of electrostatic lenses with the help of simulations. This multivariable simulation study was conducted using an object-oriented particle-in-cell code, OOPIC PRO. The results of these simulations showed the following: Einzel lens can achieve the required FSS (lower than 1 mm); lens aperture, thickness, and location of the lens can be used as a coarse control over the FSS, whereas the lens potential can be used as a fine control; and the chromatic and spherical aberrations can be reduced if Einzel lens is used.