Matthew Hudson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matthew Hudson has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- Nigel Charles Jones
Department of Neuroscience Monash University Melbourne Victoria Australia
6 shared publications - Terence John O'BRien
Department of Neuroscience, School of Translational Medicine Monash University Melbourne Victoria Australia
5 shared publications Asla Pitkänen
A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
4 shared publications- Cesar Santana-Gomez
Department of Neurology David Geffen School of Medicine at UCLA Los Angeles California USA
4 shared publications Gregory Smith
Department of Neurosurgery, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
4 shared publications- Idrish Ali
Department of Neuroscience, School of Translational Medicine Monash University Melbourne Victoria Australia
4 shared publications
Latest Publications
- Open Access
High-Frequency Activity for Language Mapping during Stereo-EEG: Comparison with Direct Cortical Stimulation
Objective: Direct cortical stimulation (DCS) is the gold standard for language mapping during SEEG but is prone to false negatives and false positives that may contribute to post-operative dysphasia or else overly conservative resections. Task-induced high-frequency activity (HFA, 30-200Hz) is an emerging functional biomarker that may augment DCS, but its clinical utility remains uncertain. We aimed to quantify HFA’s diagnostic concordance with DCS, assessing its potential as both a surrogate marker and a screening tool. Methods: In this single-centre prospective study, 23 adults undergoing SEEG completed language mapping with DCS and HFA. HFA was mapped using auditory and visual naming tasks (ANT/VNT), quantified via Morlet wavelet transforms with baseline-normalised z-scores. DCS-positive channels were those where 50Hz stimulation elicited language disruption. HFA distribution was examined independently of DCS. HFA-DCS concordance was assessed for individual and combined (ANT+VNT; maximal HFA across tasks) conditions at channel and sublobar levels across two thresholds: a specificity-optimized ‘stringent’ threshold (Z>0.8) to examine HFA as a surrogate for DCS, and a sensitivity-optimized ‘permissive’ threshold (Z>0.3) to evaluate its potential as a screening tool. Results: Twelve (52%) participants were female, and 17 (74%) were MRI-negative. HFA patterns differed by task: VNT produced greater HFA magnitude in the dominant frontal lobe (p=0.0498), while ANT produced greater magnitude and activation rate in the non-dominant temporal lobe (p=0.015; p=0.0189), highest in the non-dominant superior temporal gyrus. In the combined condition, concordance with DCS was low at the stringent threshold (channel-wise sensitivity/specificity=0.24/0.88; region-wise=0.43/0.77). Sensitivity improved at the permissive threshold (channel-wise 0.56, NPV=0.96), with region-wise sensitivity of 0.75, specificity=0.45, and NPV=0.94. Significance: Region-level HFA at a permissive threshold is useful for identifying language-negative regions and prioritising DCS testing. Poor concordance at a stringent threshold suggests HFA and DCS index distinct functional properties and are not interchangeable. Anatomically plausible HFA localisation supports the need for further multimodal validation to clarify its role in presurgical mapping. Key Points: HFA and DCS show threshold- and scale-dependent diagnostic concordance for language mapping during SEEG Sensitivity-optimized sublobar HFA shows high negative predictive value and moderate sensitivity for DCS-positive language sites These metrics support sublobar HFA as a screening tool to exclude non-eloquent regions and streamline DCS language mapping Specificity-optimized HFA concords poorly with DCS, indicating these markers index distinct properties and are not interchangeable Combined HFA/DCS profiles may help stratify surgical risk: HFA-/DCS-regions as low risk, while HFA+/DCS+ sites denote high risk
Open AccessHigh-Frequency Activity for Language Mapping during Stereo-EEG: Comparison with Direct Cortical Stimulation
Objective: Direct cortical stimulation (DCS) is the gold standard for language mapping during SEEG but is prone to false negatives and false positives that may contribute to post-operative dysphasia or else overly conservative resections. Task-induced high-frequency activity (HFA, 30-200Hz) is an emerging functional biomarker that may augment DCS, but its clinical utility remains uncertain. We aimed to quantify HFA’s diagnostic concordance with DCS, assessing its potential as both a surrogate marker and a screening tool. Methods: In this single-centre prospective study, 23 adults undergoing SEEG completed language mapping with DCS and HFA. HFA was mapped using auditory and visual naming tasks (ANT/VNT), quantified via Morlet wavelet transforms with baseline-normalised z-scores. DCS-positive channels were those where 50Hz stimulation elicited language disruption. HFA distribution was examined independently of DCS. HFA-DCS concordance was assessed for individual and combined (ANT+VNT; maximal HFA across tasks) conditions at channel and sublobar levels across two thresholds: a specificity-optimized ‘stringent’ threshold (Z>0.8) to examine HFA as a surrogate for DCS, and a sensitivity-optimized ‘permissive’ threshold (Z>0.3) to evaluate its potential as a screening tool. Results: Twelve (52%) participants were female, and 17 (74%) were MRI-negative. HFA patterns differed by task: VNT produced greater HFA magnitude in the dominant frontal lobe (p=0.0498), while ANT produced greater magnitude and activation rate in the non-dominant temporal lobe (p=0.015; p=0.0189), highest in the non-dominant superior temporal gyrus. In the combined condition, concordance with DCS was low at the stringent threshold (channel-wise sensitivity/specificity=0.24/0.88; region-wise=0.43/0.77). Sensitivity improved at the permissive threshold (channel-wise 0.56, NPV=0.96), with region-wise sensitivity of 0.75, specificity=0.45, and NPV=0.94. Significance: Region-level HFA at a permissive threshold is useful for identifying language-negative regions and prioritising DCS testing. Poor concordance at a stringent threshold suggests HFA and DCS index distinct functional properties and are not interchangeable. Anatomically plausible HFA localisation supports the need for further multimodal validation to clarify its role in presurgical mapping. Key Points: HFA and DCS show threshold- and scale-dependent diagnostic concordance for language mapping during SEEG Sensitivity-optimized sublobar HFA shows high negative predictive value and moderate sensitivity for DCS-positive language sites These metrics support sublobar HFA as a screening tool to exclude non-eloquent regions and streamline DCS language mapping Specificity-optimized HFA concords poorly with DCS, indicating these markers index distinct properties and are not interchangeable Combined HFA/DCS profiles may help stratify surgical risk: HFA-/DCS-regions as low risk, while HFA+/DCS+ sites denote high risk
- Open Access
- 17 October 2025
- Published by Wiley in Epilepsia Open
- Vol. 10 (6) , 1938-1952
Using stereo‐electroencephalography data to model the optimal intracranial venous sinus location for an endovascular seizure detection device: A feasibility study
Objective: We investigated the theoretical optimal venous location for an endovascular seizure detection device using stereo‐EEG (SEEG) data. Methods: Six venous sinus segments from consecutive SEEG patients: anterior, middle, and posterior sagittal sinus (SS‐A, SS‐M, SS‐P), straight sinus, and the ipsilateral/contralateral (relative to primary epileptogenic zone) transverse sinus (ITS, CTS). 25 mm was selected as optimal propagation distance, satisfying two criteria: (1) >80% of seizures propagated to the reference point and (2) >90% of patients had at least one electrode within this range. A sinus was classified as “detecting” a seizure if SEEG contacts within a 25 mm radius showed ictal activity at <5 s, <10 s, or any time from onset. We analyzed data at seizure level (focal‐preserved‐consciousness seizure (FPC), focal‐impaired‐consciousness seizure (FIC), and focal‐to‐bilateral‐tonic‐clonic (FBTCS)) and epilepsy level (temporal/extratemporal (TLE/ETLE)). Multilevel regression and pairwise comparisons were performed to assess detection rates across sinuses. Results: We analyzed 113 seizures (FPC: 30.1%, FIC: 50.4%, FBTCS: 19.5%) from 40 patients (TLE: 50%). At the optimal propagation distance, 86.11% of seizures propagated to the reference point. Additionally, 92.5% of seizures were detectable from at least one sinus location at any time point, with an average minimum sinus‐to‐contact distance of 9.38 mm. Seizure level: ITS had the highest seizure detection rate at any time point (FPC: 71.43%, FIC: 95.56%, FBTCS: 100%) and was superior or non‐inferior to other sinuses for FPC and FIC. No significant differences were observed for FBTCS between sinuses. Epilepsy‐level: ITS detected the most seizures at any time point (TLE: 93.75%, ETLE: 82.35%). ITS outperformed other sinuses for TLE, except the straight sinus. For ETLE, only SS‐P was significantly less effective than SS‐M and SS‐A. Significance: Based upon SEEG seizure propagation modeling, over 90% of seizures were detectable from venous sinus locations, supporting the feasibility of endovascular seizure detection devices. ITS demonstrated a high yield for seizure detection across seizure and epilepsy types. Plain Language Summary: This study aims to investigate whether seizures can be detected from venous locations and to determine the best placement for endovascular devices. Over 90% of seizures were detectable within 25 mm of the venous sinus, supporting the feasibility of this approach. The most effective venous sinus depended on the type of seizure and epilepsy. The transverse sinus on the same side as the seizure origin (ipsilateral transverse sinus, ITS) showed the highest overall potential for seizure detection. Sagittal sinus‐middle (SS‐M) was the best for detecting focal‐preserved‐consciousness seizures, while ITS and straight sinus were the best for detecting focal‐impaired‐consciousness seizures.
- 17 October 2025
- Published by Wiley in Epilepsia Open
- Vol. 10 (6) , 1938-1952
Open AccessUsing stereo‐electroencephalography data to model the optimal intracranial venous sinus location for an endovascular seizure detection device: A feasibility study
Objective: We investigated the theoretical optimal venous location for an endovascular seizure detection device using stereo‐EEG (SEEG) data. Methods: Six venous sinus segments from consecutive SEEG patients: anterior, middle, and posterior sagittal sinus (SS‐A, SS‐M, SS‐P), straight sinus, and the ipsilateral/contralateral (relative to primary epileptogenic zone) transverse sinus (ITS, CTS). 25 mm was selected as optimal propagation distance, satisfying two criteria: (1) >80% of seizures propagated to the reference point and (2) >90% of patients had at least one electrode within this range. A sinus was classified as “detecting” a seizure if SEEG contacts within a 25 mm radius showed ictal activity at <5 s, <10 s, or any time from onset. We analyzed data at seizure level (focal‐preserved‐consciousness seizure (FPC), focal‐impaired‐consciousness seizure (FIC), and focal‐to‐bilateral‐tonic‐clonic (FBTCS)) and epilepsy level (temporal/extratemporal (TLE/ETLE)). Multilevel regression and pairwise comparisons were performed to assess detection rates across sinuses. Results: We analyzed 113 seizures (FPC: 30.1%, FIC: 50.4%, FBTCS: 19.5%) from 40 patients (TLE: 50%). At the optimal propagation distance, 86.11% of seizures propagated to the reference point. Additionally, 92.5% of seizures were detectable from at least one sinus location at any time point, with an average minimum sinus‐to‐contact distance of 9.38 mm. Seizure level: ITS had the highest seizure detection rate at any time point (FPC: 71.43%, FIC: 95.56%, FBTCS: 100%) and was superior or non‐inferior to other sinuses for FPC and FIC. No significant differences were observed for FBTCS between sinuses. Epilepsy‐level: ITS detected the most seizures at any time point (TLE: 93.75%, ETLE: 82.35%). ITS outperformed other sinuses for TLE, except the straight sinus. For ETLE, only SS‐P was significantly less effective than SS‐M and SS‐A. Significance: Based upon SEEG seizure propagation modeling, over 90% of seizures were detectable from venous sinus locations, supporting the feasibility of endovascular seizure detection devices. ITS demonstrated a high yield for seizure detection across seizure and epilepsy types. Plain Language Summary: This study aims to investigate whether seizures can be detected from venous locations and to determine the best placement for endovascular devices. Over 90% of seizures were detectable within 25 mm of the venous sinus, supporting the feasibility of this approach. The most effective venous sinus depended on the type of seizure and epilepsy. The transverse sinus on the same side as the seizure origin (ipsilateral transverse sinus, ITS) showed the highest overall potential for seizure detection. Sagittal sinus‐middle (SS‐M) was the best for detecting focal‐preserved‐consciousness seizures, while ITS and straight sinus were the best for detecting focal‐impaired‐consciousness seizures.
- Open Access
A critical review of high‐frequency activity for functional mapping in SEEG
Mapping functional brain networks is a critical component of stereo–electroencephalography (SEEG) evaluations. Although direct cortical stimulation (DCS) is the clinical gold standard, it has important limitations—particularly in mapping distributed, complex functions such as language and memory, where deficits may still occur despite preservation of DCS‐positive sites, impacting quality of life. More broadly, there is increasing emphasis on preserving cognitive function in epilepsy surgery. The growing use of minimally invasive treatments—such as laser interstitial thermal therapy and radiofrequency thermocoagulation—reflects this shift. This trend highlights a need for adjunctive mapping techniques that provide anatomically precise and clinically relevant information about cortical functions, complementing existing mapping methods. Task‐induced high‐frequency activity (HFA), broadly defined as neural activity above 30 Hz, reflects localized cortical processing and has emerged as a physiologically plausible signal for functional mapping. As an activation‐based technique, HFA may complement DCS by providing additional information about cortical function to inform surgical planning and outcome prediction. Despite growing interest, clinical uptake of HFA mapping in SEEG remains limited. This likely reflects methodological heterogeneity across published studies, lack of standardized analysis pipelines, and limited validation through outcome‐linked research. Together, these challenges create uncertainty around the clinical utility of HFA. In this narrative review, we describe the neurophysiological basis of HFA, review key mapping findings across functional domains, outline practical requirements for clinical implementation, and examine major barriers to clinical translation. In doing so, we aim to provide clarity on the current evidence base and identify opportunities for future research that may support the integration of HFA mapping into clinical workflows.
Open AccessA critical review of high‐frequency activity for functional mapping in SEEG
Mapping functional brain networks is a critical component of stereo–electroencephalography (SEEG) evaluations. Although direct cortical stimulation (DCS) is the clinical gold standard, it has important limitations—particularly in mapping distributed, complex functions such as language and memory, where deficits may still occur despite preservation of DCS‐positive sites, impacting quality of life. More broadly, there is increasing emphasis on preserving cognitive function in epilepsy surgery. The growing use of minimally invasive treatments—such as laser interstitial thermal therapy and radiofrequency thermocoagulation—reflects this shift. This trend highlights a need for adjunctive mapping techniques that provide anatomically precise and clinically relevant information about cortical functions, complementing existing mapping methods. Task‐induced high‐frequency activity (HFA), broadly defined as neural activity above 30 Hz, reflects localized cortical processing and has emerged as a physiologically plausible signal for functional mapping. As an activation‐based technique, HFA may complement DCS by providing additional information about cortical function to inform surgical planning and outcome prediction. Despite growing interest, clinical uptake of HFA mapping in SEEG remains limited. This likely reflects methodological heterogeneity across published studies, lack of standardized analysis pipelines, and limited validation through outcome‐linked research. Together, these challenges create uncertainty around the clinical utility of HFA. In this narrative review, we describe the neurophysiological basis of HFA, review key mapping findings across functional domains, outline practical requirements for clinical implementation, and examine major barriers to clinical translation. In doing so, we aim to provide clarity on the current evidence base and identify opportunities for future research that may support the integration of HFA mapping into clinical workflows.
- 17 August 2022
- Published by Elsevier in Experimental Neurology
- Vol. 357, 114205
Deciphering the code: Identifying true gamma neural oscillations
- 17 August 2022
- Published by Elsevier in Experimental Neurology
- Vol. 357, 114205
Deciphering the code: Identifying true gamma neural oscillations
- 1 October 2019
- Published by Elsevier in Epilepsy Research
- Vol. 156, 106110
Harmonization of pipeline for detection of HFOs in a rat model of post-traumatic epilepsy in preclinical multicenter study on post-traumatic epileptogenesis
- 1 October 2019
- Published by Elsevier in Epilepsy Research
- Vol. 156, 106110
Harmonization of pipeline for detection of HFOs in a rat model of post-traumatic epilepsy in preclinical multicenter study on post-traumatic epileptogenesis
- 1 January 2019
- Published by Elsevier in Epilepsy Research
- Vol. 149, 92-101
Harmonization of pipeline for preclinical multicenter plasma protein and miRNA biomarker discovery in a rat model of post-traumatic epileptogenesis
- 1 January 2019
- Published by Elsevier in Epilepsy Research
- Vol. 149, 92-101
Harmonization of pipeline for preclinical multicenter plasma protein and miRNA biomarker discovery in a rat model of post-traumatic epileptogenesis
- 27 December 2018
- Published by Elsevier in Epilepsy Research
- Vol. 150, 17-26
Informatics tools to assess the success of procedural harmonization in preclinical multicenter biomarker discovery study on post-traumatic epileptogenesis
- 27 December 2018
- Published by Elsevier in Epilepsy Research
- Vol. 150, 17-26
Informatics tools to assess the success of procedural harmonization in preclinical multicenter biomarker discovery study on post-traumatic epileptogenesis
- 6 November 2017
- Published by Wiley in European Journal of Neuroscience
- Vol. 48 (8) , 2816-2825
Brain‐derived neurotrophic factor haploinsufficiency impairs high‐frequency cortical oscillations in mice
Schizophrenia is a complex psychiatric disorder with a heterogeneous aetiology involving genetic and environmental factors. Deficiencies in both brain‐derived neurotrophic factor (BDNF) and NMDA receptor function have been implicated in the disorder and may play causal and synergistic roles. Perturbations in the regulation of electrophysiological signals, including high‐frequency (γ: 30–80 Hz and β: 20–30 Hz) neuronal oscillations, are also associated with the disorder. This study investigated the influence of BDNF deficiency and NMDA receptor hypofunction on electrophysiological responses to brief acoustic stimuli. Adult BDNF heterozygote (BDNF+/−) and wild‐type littermate C57Bl/6J mice were surgically implanted with EEG recording electrodes. All mice underwent EEG recording sessions to measure ongoing and auditory‐evoked electrophysiological responses following treatment with MK‐801 (0.3 mg/kg ip) or vehicle. Western blotting on post‐mortem cortical tissue assessed parvalbumin and GAD67 expression – markers of interneurons which are involved in the generation of gamma oscillations. Compared with wild‐type controls, BDNF+/− mice exhibited markedly dampened electrophysiological responses to auditory stimuli, including reductions in the amplitude of multiple components of the event‐related potential and auditory‐evoked oscillations, as well as reduced ongoing cortical gamma oscillations. MK‐801 elevated ongoing gamma power but suppressed evoked gamma power, and this was observed equally across genotypes. BDNF+/− mice also displayed reductions in parvalbumin, but not GAD67 expression. We conclude that reduced BDNF expression leads to impairments in the generation of high‐frequency neural oscillations, but this is not synergistic with NMDA receptor hypofunction. Reduced parvalbumin expression associated with BDNF haploinsufficiency may provide a molecular explanation for these electrophysiological deficits.
- 6 November 2017
- Published by Wiley in European Journal of Neuroscience
- Vol. 48 (8) , 2816-2825
Brain‐derived neurotrophic factor haploinsufficiency impairs high‐frequency cortical oscillations in mice
Schizophrenia is a complex psychiatric disorder with a heterogeneous aetiology involving genetic and environmental factors. Deficiencies in both brain‐derived neurotrophic factor (BDNF) and NMDA receptor function have been implicated in the disorder and may play causal and synergistic roles. Perturbations in the regulation of electrophysiological signals, including high‐frequency (γ: 30–80 Hz and β: 20–30 Hz) neuronal oscillations, are also associated with the disorder. This study investigated the influence of BDNF deficiency and NMDA receptor hypofunction on electrophysiological responses to brief acoustic stimuli. Adult BDNF heterozygote (BDNF+/−) and wild‐type littermate C57Bl/6J mice were surgically implanted with EEG recording electrodes. All mice underwent EEG recording sessions to measure ongoing and auditory‐evoked electrophysiological responses following treatment with MK‐801 (0.3 mg/kg ip) or vehicle. Western blotting on post‐mortem cortical tissue assessed parvalbumin and GAD67 expression – markers of interneurons which are involved in the generation of gamma oscillations. Compared with wild‐type controls, BDNF+/− mice exhibited markedly dampened electrophysiological responses to auditory stimuli, including reductions in the amplitude of multiple components of the event‐related potential and auditory‐evoked oscillations, as well as reduced ongoing cortical gamma oscillations. MK‐801 elevated ongoing gamma power but suppressed evoked gamma power, and this was observed equally across genotypes. BDNF+/− mice also displayed reductions in parvalbumin, but not GAD67 expression. We conclude that reduced BDNF expression leads to impairments in the generation of high‐frequency neural oscillations, but this is not synergistic with NMDA receptor hypofunction. Reduced parvalbumin expression associated with BDNF haploinsufficiency may provide a molecular explanation for these electrophysiological deficits.