Jingzhe Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jingzhe Yu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Hao Zhou
College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
5 shared publications Hao Zhou
Zhejiang Provincial Key Laboratory of Electrical Machine Systems College of Electrical Engineering, Zhejiang University Hangzhou 310027 People's Republic of China
3 shared publicationsXiangrong Chen
Zhejiang Provincial Key Laboratory of Electrical Machine Systems, Zhejiang University, Hangzhou, China
3 shared publications- Bincai Zhao
State Grid Weifang Power Supply Company
1 shared publication - Chen Jiang
Department of Electronic Engineering, Tsinghua University, Beijing, China
1 shared publication Fei Su
State Grid Jinan Power Supply Company
1 shared publication
Latest Publications
- Open Access
- 1 July 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (14) , 2959-2966
Thermo‐electric field analysis of AC XLPE cable in monopole, bipole, and tripole DC operation modes
This paper presents a numerical analysis of thermo‐electric fields of 10 and 35 kV AC XLPE cables in monopole, and tripole DC operating modes based on conduction current measurements. DC conductivities and electric field thresholds of the space charge accumulation for XLPE materials were estimated at different temperatures and electric fields. The result showed that the electric field threshold of the space charge accumulation for the materials reduced with an increase of the temperature. DC currents of the cables were increased with the increase of the operating temperatures in the three DC operation modes. The maximum DC operation voltage of the cables increased with the decline of the operation temperature in the three DC operation modes. The maximum transient electric fields were below the threshold of the space charge accumulation for the cables in the tripole DC operation. The maximum transmission power of the 10 kV XLPE cable in the DC operation modes was at 60 ° C, whereas the maximum transmission power of the 35 kV XLPE cable was at 50 ° C. It was elucidated that the 10 kV AC XLPE cable could have more advantages than the 35 kV AC XLPE cable in the three DC operation modes.
- 1 July 2019
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (14) , 2959-2966
Open AccessThermo‐electric field analysis of AC XLPE cable in monopole, bipole, and tripole DC operation modes
This paper presents a numerical analysis of thermo‐electric fields of 10 and 35 kV AC XLPE cables in monopole, and tripole DC operating modes based on conduction current measurements. DC conductivities and electric field thresholds of the space charge accumulation for XLPE materials were estimated at different temperatures and electric fields. The result showed that the electric field threshold of the space charge accumulation for the materials reduced with an increase of the temperature. DC currents of the cables were increased with the increase of the operating temperatures in the three DC operation modes. The maximum DC operation voltage of the cables increased with the decline of the operation temperature in the three DC operation modes. The maximum transient electric fields were below the threshold of the space charge accumulation for the cables in the tripole DC operation. The maximum transmission power of the 10 kV XLPE cable in the DC operation modes was at 60 ° C, whereas the maximum transmission power of the 35 kV XLPE cable was at 50 ° C. It was elucidated that the 10 kV AC XLPE cable could have more advantages than the 35 kV AC XLPE cable in the three DC operation modes.
- Open Access
- 28 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 8226-8234
Numerical Analysis of Thermo-Electric Field for AC XLPE Cable in DC Operation Based on Conduction Current Measurement
With a rapid development of renewable energies and direct current (DC) loads in distribution grids, converting alternating current (AC) distribution grids into DC operation has become a promising method to utmost utilize the present AC distribution grid in large cities. This paper reports a numerical investigation of thermo-electric fields of a three-core 10 kV AC cross-linked polyethylene (XLPE) cable and cable joint in the DC operation. DC conduction current for the XLPE and silicon rubber (SiR) was evaluated at different temperatures and electric fields. The thermo-electric field simulation was performed by COMSOL Multiphysics according to the measured data. The obtained result showed that the threshold of XLPE at 65 °C is 3.1 MV/m, whereas the threshold of SiR at 60 °C is 2.2 MV/m. It was found that the maximum electric field of the cable operated in DC voltage up to 12.5 kV was below the threshold of 3.1 MV/m. The maximum electric field in the cable joint appeared at the high voltage screen tube, whereas the maximum electric field at the high voltage screen tube was less than the threshold of SiR at temperature difference of 25 °C. Moreover, the maximum transmission power of the three-core 10 kV AC XLPE cables running at the ±10 kV bipolar DC operation was 1.36 times of the power in the AC operation. It was elucidated that the three-core AC 10 kV XLPE cable could be operated reliably at ±10 kV in bipolar DC topology with sufficient safety margin. It is beneficial to upgrade the AC distribution grid to the DC distribution grid.
- 28 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 8226-8234
Open AccessNumerical Analysis of Thermo-Electric Field for AC XLPE Cable in DC Operation Based on Conduction Current Measurement
With a rapid development of renewable energies and direct current (DC) loads in distribution grids, converting alternating current (AC) distribution grids into DC operation has become a promising method to utmost utilize the present AC distribution grid in large cities. This paper reports a numerical investigation of thermo-electric fields of a three-core 10 kV AC cross-linked polyethylene (XLPE) cable and cable joint in the DC operation. DC conduction current for the XLPE and silicon rubber (SiR) was evaluated at different temperatures and electric fields. The thermo-electric field simulation was performed by COMSOL Multiphysics according to the measured data. The obtained result showed that the threshold of XLPE at 65 °C is 3.1 MV/m, whereas the threshold of SiR at 60 °C is 2.2 MV/m. It was found that the maximum electric field of the cable operated in DC voltage up to 12.5 kV was below the threshold of 3.1 MV/m. The maximum electric field in the cable joint appeared at the high voltage screen tube, whereas the maximum electric field at the high voltage screen tube was less than the threshold of SiR at temperature difference of 25 °C. Moreover, the maximum transmission power of the three-core 10 kV AC XLPE cables running at the ±10 kV bipolar DC operation was 1.36 times of the power in the AC operation. It was elucidated that the three-core AC 10 kV XLPE cable could be operated reliably at ±10 kV in bipolar DC topology with sufficient safety margin. It is beneficial to upgrade the AC distribution grid to the DC distribution grid.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 65, 629-632
Numerical analysis of thermo-electric field for 10 kV AC XLPE cable in DC operation
In this paper, a thermo-electric field coupling model was established to perform simulations on a typical three-core AC 10 kV XLPE cable in bipolar DC operation by the finite element analysis software ANSYS. The obtained results showed that when the conductor temperature of the cable was 70 o C and the cable was laid in the environmental temperature of 40 °C, the estimated cable ampacity could reach up to 440 A. The maximum of electric field in the cable insulation was settled below 3 kV/mm to minimize the effect of space charge for the cable in DC operation. It was found that the cable could run at the bipolar DC ± 10 kV with enough safety margin. Moreover, the maximum transmission power of the cable running at the bipolar DC ± 10 kV mode was 1.37 times of the power in the AC operation. It is promising for upgrading the present AC grid into future DC grid.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 65, 629-632
Numerical analysis of thermo-electric field for 10 kV AC XLPE cable in DC operation
In this paper, a thermo-electric field coupling model was established to perform simulations on a typical three-core AC 10 kV XLPE cable in bipolar DC operation by the finite element analysis software ANSYS. The obtained results showed that when the conductor temperature of the cable was 70 o C and the cable was laid in the environmental temperature of 40 °C, the estimated cable ampacity could reach up to 440 A. The maximum of electric field in the cable insulation was settled below 3 kV/mm to minimize the effect of space charge for the cable in DC operation. It was found that the cable could run at the bipolar DC ± 10 kV with enough safety margin. Moreover, the maximum transmission power of the cable running at the bipolar DC ± 10 kV mode was 1.37 times of the power in the AC operation. It is promising for upgrading the present AC grid into future DC grid.
- 22 December 2017
- Published by Springer Nature
- p. 39-66
Analysis on System Characteristics and Economy of UHV Power Transmission
- 22 December 2017
- Published by Springer Nature
- p. 39-66
Analysis on System Characteristics and Economy of UHV Power Transmission
- 22 December 2017
- Published by Springer Nature
- p. 69-162
Power Frequency Overvoltage of UHV Power Transmission Lines
- 22 December 2017
- Published by Springer Nature
- p. 69-162
Power Frequency Overvoltage of UHV Power Transmission Lines
- 22 December 2017
- Published by Springer Nature
- p. 383-460
Lightning Protection of UHVAC System
- 22 December 2017
- Published by Springer Nature
- p. 485-545
Insulation Coordination of UHVAC Transmission Lines
- 22 December 2017
- Published by Springer Nature
- p. 485-545
Insulation Coordination of UHVAC Transmission Lines