SPSergio Pérez

Sergio Pérez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sergio Pérez has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Hybrid and Coupled Model Predictions on the Performance of Separate Two- and Three-Stage Upflow Anaerobic Filters

    by Julio Maldonado-Maldonado, Adriana Márquez-Romance, Sergio Pérez-Pacheco, Edilberto Guevara-Pérez

    This paper deals with hybrid model (HM) and coupled model (CM) predictions on performance of upflow anaerobic filters (UAF) separated in two and three stages (UAF-2SS and UAF-3SS) for removing organic matter from leachates generated in two sanitary landfills in Colombia. Experimental factors to treat leachates in UAF-2SS involved volumetric organic load (VOL) {[1.8 to 4.64 kg chemical oxygen demand (COD)]/m 3 /d} and temperatures (20°C to 34°C). Leachates were treated in UAF-3SS configuring VOL (1.7 to 17.48    kg   COD / m 3 / d ) and temperature (20°C to 36°C). Six HMs and five CMs were analyzed through their kinetic parameters. Among the HMs, HM2 was made up of the main experimental factors controlled in the design and operation of the UAF-2SS and UAF-3SS, such as the depth ratio of the UAFs, temperature, and VOL. For HM5, maximum substrate utilization rate was improved as the depth ( d ) ratio was tested from d 1 / d 2 : 20%/80%, 50%/50%, and 80%/20% in UAF-2SS; and d 1 / d 2 / d 3 : 4%/16%/80%, 10%/10%/80%, and 16%/4%/80% in UAF-3SS. Maximum microbial cell growth rate was significantly increased when temperature was changed from 20°C to 34°C, and methane yield rate tended to slightly vary 10 0 − 10 1    mg CH 4 / d . CM1 to CM5 exhibited adequate trends for the UAF-2SS and UAF-3SS reactors when the substrate utilization rate ( k ) was evaluated using the medium and lower limit of the calibration interval for these models and for feeding VOL to UAF (2 to 5    kg   COD / m 3 / d ). In general, experimental data points validated the predictions of HMs and CMs, finding a satisfactory approximation for the curves obtained from the intermediate values with low VOL and those obtained from the lower limit of the calibrated intervals of the parameters with the predicted curves for high VOL, represented for the maximum S e / S i ratios. This study offers comprehensive information for the transport and transformation processes in removing COD contained in leachates from UAF-2SS and UAF-3SS.

  • Insights on Coupled Model Estimations for Designing Upflow Anaerobic Filters Separated in Two and Three Stages Removing Organic Matter from Sanitary Landfill Leachates

    by Julio Maldonado‐Maldonado, Adriana Márquez‐Romance, Sergio Pérez‐Pacheco, Edilberto Guevara‐Pérez

    This paper deals with the coupled model predictions on performance of upflow anaerobic filters separated in two and three stages (UAF‐2SS and UAF‐3SS) for removing organic matter from sanitary landfill leachates (SLLs) generated from Guayabal sanitary landfill (GSL) and La Cortada ‐SL (LCSL), Colombia. Five coupled models (CMs) were analyzed through their kinetic parameters. CM1 to CM5 exhibited adequate trends for the UAF‐2SS and UAF‐3SS reactors when the substrate utilization rate (k) was evaluated using medium and lower limit of the calibration interval for these models. All of the proposed CMs gave suitable results of S e / S i in the calibration VOL interval expressed as chemical oxygen demand (COD) (2 to 5 kg COD/m 3 /d) for UAF‐2SS and UAF‐3SS design. The best option for the UAF‐2SS and UAF‐3SS design is the CM2, followed by CM4 and CM5 due to the appropriate results of the remaining substrate ratio ( S e / S i ) in the suitable interval for feeding VOLs to UAFs (2 to 5 kg COD/m 3 /d), taking into account a comprehensive information for the transport and transformation processes in removing COD contained in SLLs from UAF‐2SS and UAF‐3SS.

  • Comparative Analysis of Hybrid Models for Designing Upflow Anaerobic Filters Separated in Two and Three Stages Treating Sanitary Landfill Leachates

    by Julio Maldonado‐Maldonado, Adriana Márquez‐Romance, Sergio Pérez‐Pacheco, Edilberto Guevara‐Pérez

    This article deals with a comparative analysis of hybrid models for designing upflow anaerobic filters separated in two and three stages (UAF‐2SS and UAF‐3SS) treating sanitary landfill leachates (SLLs) generated from Guayabal sanitary landfill (GSL) and La Cortada ‐SL (LCSL), Colombia. Experimental factors (EFs) to treat SLLs from GSL in UAF‐2SS were configured through two experimental designs (EDs). EDs1‐GSL involved volumetric organic load (VOL) (1.8 to 4.64 kg COD (Chemical Oxygen Demand)/m 3 /d), Hydraulic Retention Time (HRT) (18 h), temperatures (T) (20°C, 27°C, 34°C) SLLs from LCSL were treated in UAF‐3SS configuring four EDs: (VOL(1.7 to 17.48 kg COD/m 3 /d), T (32°C to 36°C)), HRT(8.6 h, to 22.1 h). Six hybrid models (HMs) were analyzed through their kinetic parameters and graphical depictions. Among the HMs, HMs‐1, HMs‐2, HMs‐3 and HMs‐6 tended to give satisfactory results, being suitable to select intermediate curves that relate organic remaining fraction and VOLs for the reactor design purposes. It is also recommended to low‐VOL calibrated interval (1.7 to 4.64 kgCOD/m 3 /d. For HM5, substrate utilization rate and microbial cell growth rate for methanogenic and non‐methanogenic bacteria tended to be increased as the VOL was decreased, as well as methane yield was relatively steady under different VOLs, temperature and depth ratios. The novelty consists of to provide graphical predictions to illustrate and complement the design parameters included in hybrid models for achieving an appropriate physical configuration and operation of UAF‐2SS and UAF‐3SS reactors.


  • Open Access

    Aplicación de técnicas de detección de cambios en el uso y la cobertura del suelo en la cuenca del río Pao, Venezuela, usando imágenes de satélites Landsat

    by Mairim Márquez-Romance, Adriana Márquez-Romance, Bettys Farías-De-Márquez, Sergio Pérez-Pacheco, Edilberto Guevara-Pérez

    En esta investigación se aplicaron técnicas de variación espacio-temporal de cobertura y uso en la cuenca del río Pao, localizada espacialmente en territorio venezolano, mediante procesamiento de imágenes satelitales. Se adquirieron 11 imágenes de satélite desde satélites Landsat: L5TM, L7ETM SLC (Scan Line Corrector, por sus siglas en inglés)-on, L8OLI. Las técnicas para detección de cambios han sido posclasificación y preclasificación aplicadas entre imágenes de dos fechas: 1986-2016; 1990-2016; 1991-2016, 1998-2016, 1999-2016, 2000 SLC:on-2016, 2001-2016, 2002 SLC:on-2016, 2003 SLC:on-2016, 2015-2016. Se aplicaron siete métodos de preclasificación y uno de posclasificación. La categorización de métodos de preclasificación en orden del más al menos exacto para estimación de proporción de área de cambio/ningún cambio bitemporal en coberturas y usos terrestres en la cuenca del río Pao obtenida a partir de matriz de error y ajuste de métodos a características locales de escena en imagen del satélite Landsat dieron como resultado: 1) análisis de componentes principales, 2) diferencia de imágenes de reflectancia, 3) transformación Kauth-Thomas, 4) vector de cambio, 5) relación de imágenes de reflectancia, 6) diferencia de imágenes de índice de vegetación de diferencia normalizada y 7) regresión de imágenes de reflectancia. En el método de posclasificación, la diferencia de área correspondiente a la cuenca del río Pao entre 1986 (fecha 1) y 2016 (fecha 2) dio los siguientes resultados en clases: urbano, -1.37 %; agropecuario, -22.99 %; agrícola, 1.12 %; agua, 0.55 %; vegetación, 8.1 %; suelo degradado, 9.66 %; nubes, 2.49 %; sombras, 2.28 %. El método posclasificación ha sido la opción predominante con respecto a métodos de preclasificación.

  • Analysis of the Anaerobic Digestion Process Performed by Upflow Anaerobic Filters in Two and Three Separated Stages Treating Sanitary Landfill Leachates

    by Julio Maldonado‐Maldonado, Adriana Márquez‐Romance, Sergio Pérez‐Pacheco, Edilberto Guevara‐Pérez

    This paper deals with the analysis of the anaerobic digestion process performed by Upflow Anaerobic Filters in Two and Three Separated Stages (UAF‐2SS and UAF‐3SS), treating sanitary landfill leachates (SLLs). SLLs were fed to UAF‐2SS and UAF‐3SS at three temperatures (20°C, 27°C, and 34°C), three volumetric organic loads (VOLs) (2.25, 3.45, 4.64 kgCOD (Chemical Oxygen Demand)/m 3 /d)), total depth (D) fractionation in two‐stages (D1/D2: 20%/80%, 50%/50%, and 80%/20%), and three‐stages (D1/D2/D3: 4%/16%/80%, 10%/10%/80%, and 16%/4%/80%). The microbiological sampling demonstrated that the total depth fractionation produced the prevalence of species associated with each of the stages of anaerobic digestion. In UAF‐3SS was identified the presence of hydrolytic and acidogenic bacteria in Stage 1, acidogenic and acetogenic bacteria in Stage 2, as well as acetogenic and methanogenic bacteria in Stage 3. In general, the experimental factor causing the most significant effect on the COD removal efficiency was the temperature (T), followed by the d 1 / d 2 ratio and the least influence was produced by the VOL. The effect models for orders from first to third included coefficients of the variables associated to the principal and interaction effects, that were mainly representing to the biosorption process in the residual liquid‐biofilm interface within UAF‐2SS and UAF‐3SS reactors, whose values are similar to those reported for trickling filters and tropical rivers. These results are suggesting that the first stages in the anaerobic digestion associated with hydrolysis and acidogenic reactions constitute the fundamental processes in the UAF‐2SS and UAF‐3SS perform by treating organic mass composing SLLs. The novelty of the research consists of providing mathematical structures whose coefficients allow to estimate with greater depth the rates at which the substrate transport processes are performed in the SLLs‐biofilm interface within UAF‐2SS and UAF‐3SS.


  • Open Access

    Municipal model evaluation for providing drinking water and sanitation services in a developing country

    by Universidad de Carabobo Centro de Investigaciones Hidrológicas Y Ambientales, Kerlyn Lugo, Yorman Peraza, Adriana Márquez, Edilberto Guevara, Municipio de Naguanagua Centro de Investigaciones Hidrológicas Y Ambientales Universidad de Carabobo, Sergio Pérez, Eduardo Buroz, Caracas Universidad Central de Venezuela. Academia Nacional de Ingeniería Y Hábitat

    In this study, models for the provision of drinking water and sanitation services, were evaluated for the San Joaquin Municipality, Carabobo State, Venezuela, represented in the Municipal Autonomous Institute of Water of San Joaquin (IAGUASANJO, in Spanish) through three management indexes proposed in an integrated manner for drinking water and sanitation, a model index for the provision of drinking water services and model index for the provision of sanitation services. IAGUASANJO has oriented 65 % of the activities towards the provision of sanitation services and 35 % of the actions for the provision of the drinking water service in the period 2019-2023.


  • Aplicación de técnicas de detección de cambios en el uso y la cobertura del suelo en la cuenca del río Pao, Venezuela, usando imágenes de satélites Landsat

    by Universidad de Carabobo Centro de Investigaciones Hidrológicas Y Ambientales, Mairim Márquez-Romance, Adriana Márquez-Romance, Bettys Farías-De Márquez, Sergio Pérez-Pacheco, Edilberto Guevara-Pérez, Naguanagua Centro de Investigaciones Hidrológicas Y Ambientales Universidad de Carabobo

    En esta investigación, técnicas de variación espacio-temporal de cobertura y uso fueron aplicadas en la cuenca del río Pao, localizada espacialmente en territorio venezolano, mediante procesamiento de imágenes satelitales. Once imágenes de satélite fueron adquiridas desde satélites Landsat: L5TM, L7ETM SLC (Scan Line Corrector, por sus siglas en inglés)-on, L8OLI. Las técnicas para detección de cambios han sido post-clasificación y pre-clasificación aplicadas entre imágenes de dos fechas: 1986-2016; 1990-2016; 1991-2016, 1998-2016, 1999-2016, 2000 SLC:on-2016, 2001-2016, 2002 SLC:on-2016, 2003 SLC:on-2016, 2015-2016. Siete métodos de pre-clasificación fueron aplicados y uno de postclasificación. La categorización de métodos de pre-clasificación en orden del más al menos exacto para estimación de proporción de área de cambio/ningún cambio bitemporal en coberturas y usos terrestres en la cuenca del río Pao obtenida a partir de matriz de error y ajuste de métodos a características locales de escena en imagen del satélite Landsat dieron como resultado: 1) análisis de componentes principales 2) diferencia de imágenes de reflectancia, 3) transformación Kauth-Thomas, 4) vector de cambio, 5) relación de imágenes de reflectancia, 6) diferencia de imágenes de índice de vegetación de diferencia normalizada y 7) regresión de imágenes de reflectancia. En el método de post-clasificación, la diferencia de área correspondiente a l cuenca del río Pao entre 1986 (fecha 1) – y 2016 (fecha 2) dio los siguientes resultados en clases: Urbano: -1.37%, agropecuario: -22.99%, agrícola: 1.12%, agua: 0.55%, vegetación: 8.1%, suelo degradado: 9.66%, nubes: 2.49%, sombras: 2.28%. El método post-clasificación ha sido la opción predominante con respecto a métodos pre-clasificación.

  • Municipal model evaluation for providing drinking water and sanitation services in a developing country

    by Universidad de Carabobo Centro de Investigaciones Hidrológicas Y Ambientales, Kerlyn Lugo, Yorman Peraza, Adriana Márquez, Edilberto Guevara, Municipio de Naguanagua Centro de Investigaciones Hidrológicas Y Ambientales Universidad de Carabobo, Sergio Pérez, Eduardo Buroz, Caracas Universidad Central de Venezuela. Academia Nacional de Ingeniería Y Hábitat

    En este estudio se evaluaron los modelos de prestación de los servicios de agua potable y saneamiento para el Municipio San Joaquín, Estado Carabobo, Venezuela, representado en el Instituto Autónomo Municipal de Aguas de San Joaquín (IAGUASANJO) a través de tres índices de gestión propuestos de manera integrada para el agua potable y el saneamiento, un índice de modelo para la prestación del servicio de agua potable y un índice de modelo para la prestación del servicio de saneamiento. El IAGUASANJO ha orientado el 65% de las actividades hacia la prestación del servicio de saneamiento y el 35% de las acciones para la prestación del servicio de agua potable en el periodo 2019-2023.

  • Open Access

    Reactivation of three test benches of high, medium and low power electric generators for hydraulic energy conversion

    by Mairim Hortensia Márquez-Romance, Adriana Mercedes Márquez-Romance, Bettys Farías -De Márquez, Edilberto Guevara-Pérez, Sergio Alejandro Pérez-Pacheco

    This paper deals with the reactivation of three test benches of high, medium and low power electric generators for hydraulic energy conversion in the University of Carabobo Hydraulic Laboratory. The method involves three stages: i) Description of three high, medium and low power electric generators for hydraulic energy conversion, ii) Rehabilitation of three high, medium and low power electric generators for hydraulic energy conversion and iii) Evaluation of performance indexes of high, medium and low power electric generators for hydraulic conversion. The results indicate that for the low power electric generator, the position angle of the distributor blades is an experimental factor that has a significant effect on the response variables studied. With respect to the medium and high power electric generators, the most influential factor on operation and power generation is the flow supplied.

  • Organic mass and nitrogen removal kinetic modeling in sequencing batch reactor

    by Estefanía Freytez, Adriana Márquez, María Pire, Edilberto Guevara, Sergio Pérez