Zhangji Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhangji Lu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Lilong Cai
2 shared publications- Lilong Cai
Department of Mechanical and Aerospace Engineering, The Hong Kong University of Science and Technology, Hong Kong, China
2 shared publications - Zhou Liu
Guangdong Laboratory of Artificial Intelligence and Digital Economy (Shenzhen), Shenzhen, China
2 shared publications Bo Zhang
1 shared publicationBruce Macdonald
1 shared publicationChengbo Zhang
1 shared publication
Latest Publications
- Open Access
- 9 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 12069-12078
TR-GS: High-Fidelity Sparse-View CT Volumetric Rendering via t-Distribution Gaussian Splatting and Ray-Confidence Modeling
High-fidelity 3D medical visualization supports applications such as clinical assessment and surgical planning. Sparse-view computed tomography (CT) can reduce projection requirements and associated radiation exposure, but limited observations may introduce structural artifacts and reconstruction uncertainty. Although 3D Gaussian Splatting (3DGS) provides an efficient explicit representation for volumetric rendering, existing CT methods based on standard Gaussian primitives may be sensitive to unreliable observations under sparse-view acquisition. We present TR-GS, a Gaussian-splatting framework for sparse-view CT volumetric rendering. TR-GS replaces standard Gaussian primitives with projectable Student's \(t\)-distribution primitives and introduces a ray-confidence model that regulates their degrees of freedom according to local ray observability. Confidence-guided 3D wavelet regularization is further used to balance high-frequency detail preservation and noise suppression. Experiments on synthetic and real-world datasets show that TR-GS improves over representative baselines in most evaluated settings and remains competitive in the remaining cases. The resulting volumetric representations may support downstream medical multimedia applications, including XR-based visualization and interactive clinical rendering.- 9 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 12069-12078
Open AccessTR-GS: High-Fidelity Sparse-View CT Volumetric Rendering via t-Distribution Gaussian Splatting and Ray-Confidence Modeling
High-fidelity 3D medical visualization supports applications such as clinical assessment and surgical planning. Sparse-view computed tomography (CT) can reduce projection requirements and associated radiation exposure, but limited observations may introduce structural artifacts and reconstruction uncertainty. Although 3D Gaussian Splatting (3DGS) provides an efficient explicit representation for volumetric rendering, existing CT methods based on standard Gaussian primitives may be sensitive to unreliable observations under sparse-view acquisition. We present TR-GS, a Gaussian-splatting framework for sparse-view CT volumetric rendering. TR-GS replaces standard Gaussian primitives with projectable Student's \(t\)-distribution primitives and introduces a ray-confidence model that regulates their degrees of freedom according to local ray observability. Confidence-guided 3D wavelet regularization is further used to balance high-frequency detail preservation and noise suppression. Experiments on synthetic and real-world datasets show that TR-GS improves over representative baselines in most evaluated settings and remains competitive in the remaining cases. The resulting volumetric representations may support downstream medical multimedia applications, including XR-based visualization and interactive clinical rendering. - Open Access
- 10 June 2026
- Published by Elsevier in SSRN Electronic Journal
NF-ViT: Night-Flight Vision Transformer for High-Speed Quadrotor Obstacle Avoidance in Low-Light Environments
Quadrotors possess extremely high maneuverability, but this often relies on costly sensors such as radar and depth cameras. In dense and cluttered environments with abnormal lighting conditions, traditional algorithm-based navigation methods face reduced efficiency due to sensor degradation, error accumulation, and processing delays. Learning-based end-to-end vision-control approaches show great potential in such scenarios. However, their performance typically depends on high-quality inputs, such as depth images. In nighttime or cave environments, low-light conditions degrade such information, impairing control effectiveness. This paper presents Night-Flight Vision Transformer (NF-ViT), an end-to-end visual control network designed for low-light environments. By unifying the optimization of low-light enhancement and depth estimation, we reduce sensor requirements to low-light monocular RGB images, improving generalization. Simulations and real-world flight tests demonstrate that NF-ViT outperforms existing methods at speeds up to 7 m/s, representing the first end-to-end visual control network tailored for low-light environments. A demo video is available here: https://www.bilibili.com/video/BV1DqroBUErr/
- 10 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNF-ViT: Night-Flight Vision Transformer for High-Speed Quadrotor Obstacle Avoidance in Low-Light Environments
Quadrotors possess extremely high maneuverability, but this often relies on costly sensors such as radar and depth cameras. In dense and cluttered environments with abnormal lighting conditions, traditional algorithm-based navigation methods face reduced efficiency due to sensor degradation, error accumulation, and processing delays. Learning-based end-to-end vision-control approaches show great potential in such scenarios. However, their performance typically depends on high-quality inputs, such as depth images. In nighttime or cave environments, low-light conditions degrade such information, impairing control effectiveness. This paper presents Night-Flight Vision Transformer (NF-ViT), an end-to-end visual control network designed for low-light environments. By unifying the optimization of low-light enhancement and depth estimation, we reduce sensor requirements to low-light monocular RGB images, improving generalization. Simulations and real-world flight tests demonstrate that NF-ViT outperforms existing methods at speeds up to 7 m/s, representing the first end-to-end visual control network tailored for low-light environments. A demo video is available here: https://www.bilibili.com/video/BV1DqroBUErr/
- Open Access
- 3 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 133-138
Generative AI-Driven Robustness Enhancement for Industrial Anomaly Detection in Complex Lighting Scenarios
- 3 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 133-138
Open AccessGenerative AI-Driven Robustness Enhancement for Industrial Anomaly Detection in Complex Lighting Scenarios
- 17 September 2025
- Published by Elsevier in Optics & Laser Technology
- Vol. 192
Boosting robust multimodal point cloud registration via tightly-coupled framework of visual and geometric features
- 17 September 2025
- Published by Elsevier in Optics & Laser Technology
- Vol. 192
Boosting robust multimodal point cloud registration via tightly-coupled framework of visual and geometric features
- 2 October 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (21) , 31140-31162
Calibration method for the electrically tunable lens based on shape-changing polymer
In this paper, a calibration method for the camera system with electrically tunable lens (ETL) based on shape-changing polymer (SCP) is proposed to improve the accuracy, robustness and practicality of the system. The camera model of the ETL based on SCP is proposed based on the analyses of its optical properties. The calibration strategy, including initial estimation of camera parameters and bundle adjustment is presented. To eliminate the influence of temperature on ETL in machine vision applications, a real-time temperature compensation method is proposed. The proposed method makes use of the existing calibration hardware without adding new components to the system. Both simulations and experiments are conducted to evaluate the effectiveness and accuracy of the proposed camera model and calibration method. The measurement error with the proposed calibration method is below 20 microns at high magnification, whose measurement accuracy is improved by five times than the existing method at high magnification. With the proposed calibration method for the camera system with ETL based on SCP, the calibration workload is reduced and accurate calibration at high magnification is achieved. It also benefits the development of autofocusing 3D measurement technology.
- 2 October 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (21) , 31140-31162
Calibration method for the electrically tunable lens based on shape-changing polymer
In this paper, a calibration method for the camera system with electrically tunable lens (ETL) based on shape-changing polymer (SCP) is proposed to improve the accuracy, robustness and practicality of the system. The camera model of the ETL based on SCP is proposed based on the analyses of its optical properties. The calibration strategy, including initial estimation of camera parameters and bundle adjustment is presented. To eliminate the influence of temperature on ETL in machine vision applications, a real-time temperature compensation method is proposed. The proposed method makes use of the existing calibration hardware without adding new components to the system. Both simulations and experiments are conducted to evaluate the effectiveness and accuracy of the proposed camera model and calibration method. The measurement error with the proposed calibration method is below 20 microns at high magnification, whose measurement accuracy is improved by five times than the existing method at high magnification. With the proposed calibration method for the camera system with ETL based on SCP, the calibration workload is reduced and accurate calibration at high magnification is achieved. It also benefits the development of autofocusing 3D measurement technology.
- 27 July 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (22) , 6600-6611
Accurate three-dimensional measurement for small objects based on the thin-lens model
Both accuracy and depth of field (DOF) are required for small objects’ measurement in advanced manufacture and accurate robotics industries. In this paper, a stereo vision system with structured light based on the thin-lens model is developed to measure small objects with high accuracy and extended DOF at high magnification. The model of the proposed stereo vision system is built. The new system calibration scheme and measurement procedures are proposed. The DOF of the used thin-lens model is extended by utilizing autofocus capability. With the thin-lens model, accurate calibration and extended DOF at high magnification can be achieved. Three measurement experiments are conducted with the proposed system to evaluate its effectiveness and accuracy. The error of the protrusions’ height on the reconstructed aluminum part is lower than 0.55%, and the standard deviation (STD) of a fitting plane reaches 1.7 µm. Low cost, high accuracy, and extended DOF can be simultaneously achieved for measuring small objects with the proposed system based on the thin-lens model.
- 27 July 2020
- Published by Optica Publishing Group in Applied Optics
- Vol. 59 (22) , 6600-6611
Accurate three-dimensional measurement for small objects based on the thin-lens model
Both accuracy and depth of field (DOF) are required for small objects’ measurement in advanced manufacture and accurate robotics industries. In this paper, a stereo vision system with structured light based on the thin-lens model is developed to measure small objects with high accuracy and extended DOF at high magnification. The model of the proposed stereo vision system is built. The new system calibration scheme and measurement procedures are proposed. The DOF of the used thin-lens model is extended by utilizing autofocus capability. With the thin-lens model, accurate calibration and extended DOF at high magnification can be achieved. Three measurement experiments are conducted with the proposed system to evaluate its effectiveness and accuracy. The error of the protrusions’ height on the reconstructed aluminum part is lower than 0.55%, and the standard deviation (STD) of a fitting plane reaches 1.7 µm. Low cost, high accuracy, and extended DOF can be simultaneously achieved for measuring small objects with the proposed system based on the thin-lens model.
- 30 June 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (14) , 20858-20878
Camera calibration method with focus-related intrinsic parameters based on the thin-lens model
In this paper, a calibration method for a camera with focus-related intrinsic parameters based on the thin-lens model is proposed to realize highly accurate measurement for small objects with extended depth of field (DOF). It mainly solves inaccurate calibration and small DOF problems at high magnification of vision systems. The mathematical camera model, initial camera calibration based on the iterative radial alignment constraint (IRAC) and optimization strategy are presented. The effectiveness, accuracy and practicality of the proposed calibration method are verified by both simulations and experiments. The root mean square errors of measured points in the 3D world coordinates with the proposed calibration method decrease from 22.02 μm to 1.66 μm when the magnification of the vision system increases from 0.12× to 0.66×. With the proposed calibration method based on the thin-lens model, accurate measurement, extended DOF and low calibration workload can be achieved.
- 30 June 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (14) , 20858-20878
Camera calibration method with focus-related intrinsic parameters based on the thin-lens model
In this paper, a calibration method for a camera with focus-related intrinsic parameters based on the thin-lens model is proposed to realize highly accurate measurement for small objects with extended depth of field (DOF). It mainly solves inaccurate calibration and small DOF problems at high magnification of vision systems. The mathematical camera model, initial camera calibration based on the iterative radial alignment constraint (IRAC) and optimization strategy are presented. The effectiveness, accuracy and practicality of the proposed calibration method are verified by both simulations and experiments. The root mean square errors of measured points in the 3D world coordinates with the proposed calibration method decrease from 22.02 μm to 1.66 μm when the magnification of the vision system increases from 0.12× to 0.66×. With the proposed calibration method based on the thin-lens model, accurate measurement, extended DOF and low calibration workload can be achieved.
- 23 January 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (3) , 2044-2055
Paraxial focal length measurement method with a simple apparatus
In this paper, we realize an accurate and flexible measurement method for paraxial focal length with a simple apparatus. The proposed method utilizes the established measurement principle which is based on the differentiation of the Gaussian optical formula and geometrical relationship of camera-lens system to obtain the focal length of a lens. Some image processing methods are employed to experimentally realize this measurement principle with high accuracy and practicability. Image sharpness evaluation function is utilized to ensure the system conforms to the Gaussian optical formula. System calibration is adopted to compensate for the errors caused by the simple apparatus. In addition, aberration is considered to obtain a paraxial focal length of a lens. Experimental results indicate that repeatability error of measurement system is less than 0.11% for most lenses.
- 23 January 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (3) , 2044-2055
Paraxial focal length measurement method with a simple apparatus
In this paper, we realize an accurate and flexible measurement method for paraxial focal length with a simple apparatus. The proposed method utilizes the established measurement principle which is based on the differentiation of the Gaussian optical formula and geometrical relationship of camera-lens system to obtain the focal length of a lens. Some image processing methods are employed to experimentally realize this measurement principle with high accuracy and practicability. Image sharpness evaluation function is utilized to ensure the system conforms to the Gaussian optical formula. System calibration is adopted to compensate for the errors caused by the simple apparatus. In addition, aberration is considered to obtain a paraxial focal length of a lens. Experimental results indicate that repeatability error of measurement system is less than 0.11% for most lenses.