SMSriram Muthukumar

Sriram Muthukumar

*This is an algorithmically generated author record based on publicly available information.

Sriram Muthukumar has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    SODS: Soil Health On-Demand Sensors—A Multi Parameter Field Study with Temporal Monitoring

    by Vikram Narayanan Dhamu, Mohammed A. Eldeeb, Anil C. Somenahally, Sriram Muthukumar, Shalini Prasad

    Real-time monitoring of soil health parameters is crucial for efficient use of resources, improving agricultural productivity, and sustainability. Traditional soil analysis methods, although accurate, are time-consuming and lack the spatial and temporal resolution necessary for dynamic agricultural environments. Recent advancements in sensor technology offer promising alternatives, enabling real-time, in situ monitoring of key soil health indicators. This study details the deployment and validation of novel Sensor-in-Field probes at the Donald Danforth Plant Science Center Farm in Missouri, U.S., in a winter wheat plot. Three Sensor-in-Field probes were evaluated for their ability to measure nitrate (NO3), ammonium (NH4), soil organic matter (SOM), carbonaceous soil minerals (CSMs), soil volumetric density (SVD), soil hydration state (SHS), and total soil carbon (TSC) over a 28-day period. The probes’ coefficients of variation were well within acceptable limits (<20%) for all parameters. The measured metrics averaged 0.05% ± 0.001 and 1.92% ± 0.02 for CSMs and SOM, respectively, while TSC was 1.18% ± 0.15. For the nutrients, the measured NO3 and NH4 values were 4.44 ppm ± 0.37 and 2.78 ppm ± 0.22, respectively. The accuracy of the soil probes was validated at a certified traditional soil analysis laboratory. Three samples were collected at three different time points and analyzed. Bland–Altman analysis showed <± 10% difference between the soil probes and traditional lab analysis for CSMs, SOM, and TSC, while t-test analysis reported p-values > 0.005 for NO3, NH4, and SHS/SVD, indicating non-significant differences between the probes and traditional soil analysis methods.


  • Open Access

    Electroanalytical Platform for Rapid E. coli O157:H7 Detection in Water Samples

    by Kundan Kumar Mishra, Vikram Narayanan Dhamu, Chesna Jophy, Sriram Muthukumar, Shalini Prasad

    There is a pressing need to enhance early detection methods of E. coli O157:H7 to mitigate the occurrence and consequences of pathogenic contamination and associated outbreaks. This study highlights the efficacy of a portable electrochemical sensing platform that operates without faradaic processes towards detecting and quantifying E. coli O157:H7. It is specifically tailored for quick identification in potable water. The assay processing time is approximately 5 min, addressing the need for swift and efficient pathogen detection. The sensing platform was constructed utilizing specific, monoclonal E. coli antibodies, based on single-capture, non-faradaic, electrochemical immunoassay principles. The E. coli sensor assay underwent testing over a wide concentration range, spanning from 10 to 105 CFU/mL, and a limit of detection (LoD) of 1 CFU/mL was demonstrated. Significantly, the sensor’s performance remained consistent across studies, with both inter- and intra-study coefficients of variation consistently below 20%. To evaluate real-world feasibility, a comparative examination was performed between laboratory-based benchtop data and data obtained from the portable device. The proposed sensing platform exhibited remarkable sensitivity and selectivity, enabling the detection of minimal E. coli concentrations in potable water. This successful advancement positions it as a promising solution for prompt on-site detection, characterized by its portability and user-friendly operation. This study presents electrochemical-based sensors as significant contributors to ensuring food safety and public health. They play a crucial role in preventing the occurrence of epidemics and enhancing the supervision of water quality.


  • Open Access

    A Proof-of-Concept Electrochemical Skin Sensor for Simultaneous Measurement of Glial Fibrillary Acidic Protein (GFAP) and Interleukin-6 (IL-6) for Management of Traumatic Brain Injuries

    by Sarah Shahub, Kai-Chun Lin, Sriram Muthukumar, Shalini Prasad

    This work demonstrates the use of a noninvasive, sweat-based dual biomarker electrochemical sensor for continuous, prognostic monitoring of a Traumatic Brain Injury (TBI) with the aim of enhancing patient outcomes and reducing the time to treatment after injury. A multiplexed SWEATSENSER was used for noninvasive continuous monitoring of glial fibrillary acidic protein (GFAP) and Interleukin-6 (IL-6) in a human sweat analog and in human sweat. Electrochemical impedance spectroscopy (EIS) and chronoamperometry (CA) were used to measure the sensor response. The assay chemistry was characterized using Fourier Transform Infrared Spectroscopy (FTIR). The SWEATSENSER was able to detect GFAP and IL-6 in sweat over a dynamic range of 3 log orders for GFAP and 2 log orders for IL-6. The limit of detection (LOD) for GFAP detection in the sweat analog was estimated to be 14 pg/mL using EIS and the LOD for IL-6 was estimated to be 10 pg/mL using EIS. An interference study was performed where the specific signal was significantly higher than the non-specific signal. Finally, the SWEATSENSER was able to distinguish between GFAP and IL-6 in simulated conditions of a TBI in human sweat. This work demonstrates the first proof-of-feasibility of a multiplexed TBI marker combined with cytokine and inflammatory marker detection in passively expressed sweat in a wearable form-factor that can be utilized toward better management of TBIs. This is the first step toward demonstrating a noninvasive enabling technology that can enable baseline tracking of an inflammatory response.


  • Open Access

    Enzymatic Low Volume Passive Sweat Based Assays for Multi-Biomarker Detection

    by Ashlesha Bhide, Sarah Cheeran, Sriram Muthukumar, Shalini Prasad

    Simultaneous detection of correlated multi-biomarkers on a single low-cost platform in ultra-low fluid volumes with robustness is in growing demand for the development of wearable diagnostics. A non-faradaic biosensor for the simultaneous detection of alcohol, glucose, and lactate utilizing low volumes (1–5 μL) of sweat is demonstrated. Biosensing is implemented using nanotextured ZnO films integrated on a flexible porous membrane to achieve enhanced sensor performance. The ZnO sensing region is functionalized with enzymes specific for the detection of alcohol, glucose, and lactate in the ranges encompassing their physiologically relevant levels. A non-faradaic chronoamperometry technique is used to measure the current changes associated with interactions of the target biomarkers with their specific enzyme. The specificity performance of the biosensing platform was established in the presence of cortisol as the non-specific molecule. Biosensing performance of the platform in a continuous mode performed over a 1.5-h duration showed a stable current response to cumulative lifestyle biomarker concentrations with capability to distinguish reliably between low, mid, and high concentration ranges of alcohol (0.1, 25, 100 mg/dL), glucose (0.1, 10, 50 mg/dL), and lactate (1, 50, 100 mM). The low detection limits and a broader dynamic range for the lifestyle biomarker detection are quantified in this research demonstrating its suitability for translation into a wearable device.