SDSumit Dass

Sumit Dass

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sumit Dass has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Optical Biosensing Through Surface Plasmon Resonance

    by Sumit Dass

    Surface plasmon resonance (SPR) is a well-established optical technique used to study biomolecular interactions in a label-free and real-time manner. This chapter presents a review of SPR-based biosensing, focusing on experimental developments and applications over the years. SPR’s ability to monitor binding events without the need for fluorescent or radioactive labeling has supported its use across a variety of biosensing scenarios. The chapter outlines key stages in the development of SPR-based sensors, including strategies to enhance sensitivity, selectivity, and system integration. Representative examples illustrate SPR’s role in disease biomarker detection, antibody characterization, pollutant and pathogen surveillance, and genetic analysis. The chapter also discusses recent trends toward miniaturization, multiplexing, and field-deployable formats. By tracing both foundational and current work, the chapter aims to provide readers with a broad perspective on the use of SPR in biosensing and its evolving role in the design of analytical platforms.

  • Open Access

    An in situ stereo‐imaging system for characterizing behavior, distributions, and aggregations of meso‐ and macro‐zooplankton in diverse aquatic environments

    by Sumit Dass, Alexis Base, Karuna Agarwal, Aditya R. Nayak

    Zooplankton play a critical role in aquatic ecosystems, serving as a key link in food webs and contributing to nutrient cycling and the biological pump. Despite their importance, challenges remain in capturing high‐resolution in situ data, especially for understanding zooplankton behavior and aggregation across multiple size classes. This study introduces a custom‐built stereo‐imaging system capable of precise spatial 3D estimation, enabling characterization of individual and group behavioral observations of meso‐ and macrozooplankton and other organisms (e.g., micronekton) in the ~ 0.5 mm to 9 cm size range in their natural habitats. The stereo‐imaging system employs two high‐resolution monochrome cameras, offering real‐time visualization and adaptive sampling. Laboratory validation experiments demonstrated consistent and reliable performance across various configurations for spatial 3D measurement within the imaging volume, with overall coefficients of variation < 2%. Field deployments successfully highlighted the in situ observational capabilities of the system, with data processing allowing for computation of both individual and aggregation metrics, including but not limited to organism swimming speeds and acceleration, swarm/school densities, orientation, polarization order, and nearest neighbor distances. The comprehensive observations enabled by the stereo‐imaging system can potentially offer valuable insights into complex behavioral patterns, social interactions, and predator–prey dynamics, highlighting how future applications in targeted studies could enhance our understanding of meso‐ and macrozooplankton ecology.

  • Underwater low acoustic frequency detection based on in-line Mach–Zehnder interferometer

    by Sumit Dass, Rajan Jha

    We propose and demonstrate an in-line Mach–Zehnder interferometer (IMZI) as an optical hydrophone. The IMZI is fabricated by creating two tapers in the single-mode fiber (SMF), and the two tapered sections are separated by a small section of untapered SMF. To achieve higher sensitivity, this IMZI is attached to a circular natural rubber (NR) diaphragm. The sensing mechanism is based on the acoustic pressure-induced wavelength shift of the IMZI transmission spectrum. The proposed hydrophone is tested underwater with acoustic signals of different frequencies in the range of 15–250 Hz. For a specific IMZI structure, the hydrophone shows a sensitivity of 27.93 nm/Pa and a noise-limited minimum detectable pressure of 5.53 m P a / √ H z . One can tailor the acoustic sensitivity of the proposed hydrophone by changing different parameters of diaphragm and IMZI. The excellent underwater performance of the NR diaphragm makes the proposed hydrophone an efficient and economical system for underwater low-frequency acoustic signal detection.


  • In Reflection Metal-Coated Diaphragm Microphone Using PCF Modal Interferometer

    by Sumit Dass, Kalipada Chatterjee, Santosh Kachhap, Rajan Jha

    Starting from non-destructive testing to underwater surveillance, acoustic sensors are finding a variety of modern-day applications. In this article, we propose a double/hybrid interferometry optical microphone. We have combined the intermodal interference of SMF-SCPCF section with extrinsic Fabry-Perot interferometer to construct a highly sensitive, compact and robust optical microphone. The sensor head consists of an SMF-SCPCF spliced section placed in front of an aluminium coated nitrile diaphragm. The acoustic sensitivity and noise-limited minimum detectable pressure (MDP) of the proposed microphone is 34.8 nm/kPa and 0.26 P/√Hz at 1400 Hz. We also recorded the angular response of the proposed optical microphone and the final directionality pattern is of `cardioid' type which makes it a preferable option for a wide variety of applications.


  • Hearing the Sounds of Aquatic Life Using Optical Fiber Microtip-Based Hydrophone

    by Sumit Dass, Santosh Kachhap, Rajan Jha

    For marine bioacoustics applications, the sounds by aquatic animals must be recorded with a high precision and minimal noise in order to extract valuable information. For such marine applications, we propose and demonstrate an optical fiber microtip-based hydrophone. The hydrophone design consists of an extrinsic Fabry-Perot interferometer, which utilizes fiber microtip and processed aluminum foil as two partially reflecting mirrors. The packaged optical fiber hydrophone of dimensions 1.4 cm × 1.4 cm × 2 cm, with a microtip diameter of 31.23 μm and natural rubber diaphragm of 6 mm diameter, shows a high sensitivity of 8.94 nm/mPa or -41.42-dB re 1 nm/μPa at 1 kHz. The hydrophone shows an excellent signal-to-noise low as 0.388 μPa/√Hz at 1 kHz. The linear working range of ratio, and the noise-limited minimum detectable pressure is as the hydrophone is 0-3950 Hz. The experimental results show that the proposed optical fiber hydrophone can very accurately detect the click trains produced by dolphins for echolocation. Furthermore, depending on the applications, the performance parameters of the proposed hydrophone can be tailored by changing the diaphragm thickness and diameter, thus opening a new platform to study the marine environment.


  • Open Access

    S-shaped microfiber based diaphragm supported optical microphone

    by Sumit Dass, Santosh Kachhap, Rajan Jha

    We propose and demonstrate a simple and highly sensitive optical microphone based on S-shaped tapered fibre (STF). The short pigtailed end of the STF is attached to the centre of a thin circular nitrile diaphragm. The applied acoustic signal deforms the nitrile diaphragm and due to the affixation, the STF structure gets modified leading to change in the bending angles of the two STF bends. As a consequence, the photodetector output, detecting the reflected light intensity of the STF, varies in accordance with the applied acoustic signal. Various properties of the proposed sensing setup can be easily tailored by changing the diaphragm diameter and thickness, and the shapes and size of the STF. For an optimized configuration, the proposed sensor achieves a sensitivity of 3.07 mV Pa−1 and a minimum detectable pressure of 36.48 mPa Hz−1. The sensor shows a linear behaviour up to 1300 Hz and the experimental value of its first order natural frequency is 1455 Hz.


  • Open Access

    Micro-tip Cantilever as Low Frequency Microphone

    by Sumit Dass, Rajan Jha

    We propose a very compact diaphragm free optical microphone consisting a tapered micro-tip in cantilever configuration for detection of low frequency acoustic signals. The change in the light coupling between the micro-tip and the source fiber caused by the acoustic pressure is utilized to detect the external acoustic signal. The sensitivity and working range of the sensor depend on three key factors, the length of the micro-tip cantilever, the distance between the micro-tip and SMF, and the offset between the micro-tip central axis and SMF central axis. Hence, by changing any of these parameters, the performance of the sensor can be easily tuned. Experimental results show that for a cantilever length of 15 mm, the probe has a maximum acoustic sensitivity of 10.63 mV/Pa or −159.5 dB re 1 V/μPa, noise-limited minimum detectable pressure of 19.1 mPa/√Hz and the linear frequency range is 0–400 Hz. The SMF only structure along with photodetector-based interrogation makes this acoustic sensor economical.


  • Square Knot Resonator-Based Compact Bending Sensor

    by Sumit Dass, Rajan Jha

    In this letter, design and development of a square knot resonator (SKR) for sensing applications is proposed. The SKR is developed by carefully weaving a single-ended microfiber in and out of a double-ended microfiber. The dependence of the SKR's resonance wavelength on the circular path length and the effective index of microfiber is utilized to sense the bending. Two 4.5-cm-long and 16-μm-diameter tapered microfibers are used to construct an SKR having a diameter of 885 μm which has a free spectral range of 0.505 nm, and the Q-factor is more than 14500. Experimental results show that the bending sensitivity of the SKR is 3.04 nm/m -1 with a maximum theoretical resolution of 3.29 × 10 -3 m -1 . The temperature sensitivity of the SKR is 3.2 pm/°C.


  • Tapered Fiber Attached Nitrile Diaphragm-Based Acoustic Sensor

    by Sumit Dass, Rajan Jha

    We present a low-cost acoustic sensor using tapered fiber structure attached to a nitrile polymer based diaphragm. The tapered fiber is attached in the line of symmetry of a circular diaphragm of optimized thickness and diameter. The applied acoustic pressure deforms the diaphragm which bends the tapered fiber attached with it. The bending induced change in transmission power is utilised to detect the applied acoustic pressure. The acoustic sensitivity and minimum detectable pressure at 2500 Hz are 36 mV/kPa and 21.11 Pa/$\sqrt{}$Hz, respectively, for the sensor setup with tapered fiber waist diameter of 18.37 $\mu$m. The sensor shows a reasonably flat response from 250 Hz to 2500 Hz. The performance parameters of the sensor, such as sensitivity, minimum detectable pressure and flat response range can be easily tailored by changing the dimensions of diaphragm and tapered fiber.