Vijay Viswam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vijay Viswam has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Hierlemann
Department of Biosystems Science and Engineering, ETH Zurich, Basel, Switzerland
6 shared publications Raziyeh Bounik
ETH Zürich, D-BSSE, Switzerland
4 shared publicationsAmir Shadmani
Bio Engineering Laboratory, ETH Zurich, Basel, Switzerland
3 shared publications- Amir Shadmani
Bio Engineering Laboratory, Department of Biosystems Science and Engineering, ETH Zurich, Basel 4058, Switzerland
3 shared publications Jelena Dragas
Bio Engineering Laboratory, Department of Biosystems Science and Engineering, ETH Zurich, Basel 4058, Switzerland
3 shared publications- Marie Engelene J. Obien
MaxWell Biosystems, Zurich, Switzerland
3 shared publications
Latest Publications
- 1 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (9) , 2481-2490
Stimulation and Artifact-Suppression Techniques for In Vitro High-Density Microelectrode Array Systems
We present novel voltage stimulation buffers with controlled output current, along with recording circuits featuring adjustable high-pass cut-off filtering to perform efficient stimulation while actively suppressing stimulation artifacts in high-density microelectrode arrays. Owing to the dense packing and close proximity of the electrodes in such systems, a stimulation through one electrode can cause large electrical artifacts on neighboring electrodes that easily saturate the corresponding recording amplifiers. To suppress such artifacts, the high-pass corner frequencies of all available 2048 recording channels can be raised from several Hz to several kHz by applying a “soft-reset” or pole-shifting technique. With the implemented artifact suppression technique, the saturation time of the recording circuits, connected to electrodes in immediate vicinity to the stimulation site, could be reduced to less than 150 μs. For the stimulation buffer, we developed a circuit, which can operate in two modes: either control of only the stimulation voltage or control of current and voltage during stimulation. The voltage-only controlled mode employs a local common-mode feedback operational transconductance amplifier with a near rail-to-rail input/output range, suitable for driving high-capacitive loads. The current/voltage controlled mode is based on a positive current conveyor generating adjustable output currents, whereas its upper and lower output voltages are limited by two feedback loops. The current/voltage controlled circuit can generate stimulation pulses up to 30 μA with less than ±0.1% linearity error in the low-current mode and up to 300 μA with less than ±0.2% linearity error in the high-current mode.
- 1 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (9) , 2481-2490
Stimulation and Artifact-Suppression Techniques for In Vitro High-Density Microelectrode Array Systems
We present novel voltage stimulation buffers with controlled output current, along with recording circuits featuring adjustable high-pass cut-off filtering to perform efficient stimulation while actively suppressing stimulation artifacts in high-density microelectrode arrays. Owing to the dense packing and close proximity of the electrodes in such systems, a stimulation through one electrode can cause large electrical artifacts on neighboring electrodes that easily saturate the corresponding recording amplifiers. To suppress such artifacts, the high-pass corner frequencies of all available 2048 recording channels can be raised from several Hz to several kHz by applying a “soft-reset” or pole-shifting technique. With the implemented artifact suppression technique, the saturation time of the recording circuits, connected to electrodes in immediate vicinity to the stimulation site, could be reduced to less than 150 μs. For the stimulation buffer, we developed a circuit, which can operate in two modes: either control of only the stimulation voltage or control of current and voltage during stimulation. The voltage-only controlled mode employs a local common-mode feedback operational transconductance amplifier with a near rail-to-rail input/output range, suitable for driving high-capacitive loads. The current/voltage controlled mode is based on a positive current conveyor generating adjustable output currents, whereas its upper and lower output voltages are limited by two feedback loops. The current/voltage controlled circuit can generate stimulation pulses up to 30 μA with less than ±0.1% linearity error in the low-current mode and up to 300 μA with less than ±0.2% linearity error in the high-current mode.
- 11 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (6) , 1356-1368
Impedance Spectroscopy and Electrophysiological Imaging of Cells With a High-Density CMOS Microelectrode Array System
A monolithic multi-functional CMOS microelectrode array system was developed that enables label-free electrochemical impedance spectroscopy of cells in vitro at high spatiotemporal resolution. The electrode array includes 59,760 platinum microelectrodes, densely packed within a 4.5 mm × 2.5 mm sensing region at a pitch of 13.5 μm. A total of 32 on-chip lock-in amplifiers can be used to measure the impedance of any arbitrarily chosen subset of electrodes in the array. A sinusoidal voltage, generated by an on-chip waveform generator with a frequency range from 1 Hz to 1 MHz, was applied to the reference electrode. The sensing currents through the selected recording electrodes were amplified, demodulated, filtered, and digitized to obtain the magnitude and phase information of the respective impedances. The circuitry consumes only 412 μW at 3.3 V supply voltage and occupies only 0.1 mm 2 , for each channel. The system also included 2048 extracellular action-potential recording channels on the same chip. Proof of concept measurements of electrical impedance imaging and electrophysiology recording of cardiac cells and brain slices are demonstrated in this paper. Optical and impedance images showed a strong correlation.
- 11 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (6) , 1356-1368
Impedance Spectroscopy and Electrophysiological Imaging of Cells With a High-Density CMOS Microelectrode Array System
A monolithic multi-functional CMOS microelectrode array system was developed that enables label-free electrochemical impedance spectroscopy of cells in vitro at high spatiotemporal resolution. The electrode array includes 59,760 platinum microelectrodes, densely packed within a 4.5 mm × 2.5 mm sensing region at a pitch of 13.5 μm. A total of 32 on-chip lock-in amplifiers can be used to measure the impedance of any arbitrarily chosen subset of electrodes in the array. A sinusoidal voltage, generated by an on-chip waveform generator with a frequency range from 1 Hz to 1 MHz, was applied to the reference electrode. The sensing currents through the selected recording electrodes were amplified, demodulated, filtered, and digitized to obtain the magnitude and phase information of the respective impedances. The circuitry consumes only 412 μW at 3.3 V supply voltage and occupies only 0.1 mm 2 , for each channel. The system also included 2048 extracellular action-potential recording channels on the same chip. Proof of concept measurements of electrical impedance imaging and electrophysiology recording of cardiac cells and brain slices are demonstrated in this paper. Optical and impedance images showed a strong correlation.
- Open Access
- 1 January 2018
- Published by Frontiers Media SA in Frontiers in Cellular Neuroscience
- Vol. 12
Electrical Impedance Tomography on High-density Microelectrode Arrays
Electrical impedance tomography (EIT) is a non-invasive, label-free imaging technique that enables to reconstruct the conductivity distribution in a body from a series of impedance measurements. Impedance measurements can be used to determine the position, morphology, and growth of cells or tissues, as well as pathological signs, e.g., precancerous tissue conditions (Gersing 1999). The newest high-density microelectrode array (MEA) system developed in our group features 59,760 integrated electrodes (Dragas et al. 2017). The chip features a variety of electrophysiological functions: Action-potential recording (2048 channels), cyclic voltammetry (28 channels), local-field-potential recording (32 channels) and extracellular stimulation (16 channels) [Fig 1A]. The chip can also measure impedance through 32 channels, which enables EIT measurements. We were able to establish a proof of concept for EIT (Viswam et al. 2017). The current goal of this project is to develop an impedance measurement protocol and an appropriate reconstruction algorithm that allow for single-cell-resolution impedance imaging. Material and Methods An acute slice of mouse brain was placed on the array within a well containing carbogen-bubbled calcium-free artificial cerebrospinal fluid. A sinusoidal voltage, generated with the chip’s built-in wave generator was applied to the reference electrode, and the induced current was sensed with the MEA electrodes. Using 120 configurations of 3840 sparsely configured electrodes, an impedance map was measured. The raw data, containing the magnitude and phase of the measured signals was then processed in Matlab using a custom-made code. We are currently working on an alternate impedance measurement protocol, where selected electrodes in the array are used for the input signal, and the induced currents are then measured in adjacent electrodes [Fig. 1B]. By rapidly changing electrode configurations, a scan of the region of interest can be obtained. Results By creating an impedance magnitude heat map of the tissue, we established a proof of concept for EIT measurements with our chip. Discussion As a pixel of the array is 13.5 µm x 13.5 µm, it should be possible to improve the resolution down to single cell level, which enables exact localization of cells on the array. This is the focus of our ongoing work. After establishing a suitable electrode configuration sequence, we will develop a reconstruction code, drawing on the material available through the Electrical Impedance and Diffuse Optical Reconstruction Software project (Adler et al. 2017).
- 1 January 2018
- Published by Frontiers Media SA in Frontiers in Cellular Neuroscience
- Vol. 12
Open AccessElectrical Impedance Tomography on High-density Microelectrode Arrays
Electrical impedance tomography (EIT) is a non-invasive, label-free imaging technique that enables to reconstruct the conductivity distribution in a body from a series of impedance measurements. Impedance measurements can be used to determine the position, morphology, and growth of cells or tissues, as well as pathological signs, e.g., precancerous tissue conditions (Gersing 1999). The newest high-density microelectrode array (MEA) system developed in our group features 59,760 integrated electrodes (Dragas et al. 2017). The chip features a variety of electrophysiological functions: Action-potential recording (2048 channels), cyclic voltammetry (28 channels), local-field-potential recording (32 channels) and extracellular stimulation (16 channels) [Fig 1A]. The chip can also measure impedance through 32 channels, which enables EIT measurements. We were able to establish a proof of concept for EIT (Viswam et al. 2017). The current goal of this project is to develop an impedance measurement protocol and an appropriate reconstruction algorithm that allow for single-cell-resolution impedance imaging. Material and Methods An acute slice of mouse brain was placed on the array within a well containing carbogen-bubbled calcium-free artificial cerebrospinal fluid. A sinusoidal voltage, generated with the chip’s built-in wave generator was applied to the reference electrode, and the induced current was sensed with the MEA electrodes. Using 120 configurations of 3840 sparsely configured electrodes, an impedance map was measured. The raw data, containing the magnitude and phase of the measured signals was then processed in Matlab using a custom-made code. We are currently working on an alternate impedance measurement protocol, where selected electrodes in the array are used for the input signal, and the induced currents are then measured in adjacent electrodes [Fig. 1B]. By rapidly changing electrode configurations, a scan of the region of interest can be obtained. Results By creating an impedance magnitude heat map of the tissue, we established a proof of concept for EIT measurements with our chip. Discussion As a pixel of the array is 13.5 µm x 13.5 µm, it should be possible to improve the resolution down to single cell level, which enables exact localization of cells on the array. This is the focus of our ongoing work. After establishing a suitable electrode configuration sequence, we will develop a reconstruction code, drawing on the material available through the Electrical Impedance and Diffuse Optical Reconstruction Software project (Adler et al. 2017).
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2017, 1-4
Acquisition of bioelectrical signals with small electrodes
Although the mechanisms of recording bioelectrical signals from different types of electrogenic cells (neurons, cardiac cells etc.) by means of planar metal electrodes have been extensively studied, the recording characteristics and conditions for very small electrode sizes are not yet established. Here, we present a combined experimental and computational approach to elucidate, how the electrode size influences the recorded signals, and how inherent properties of the electrode, such as impedance, noise, and transmission characteristics shape the signal. We demonstrate that good quality recordings can be achieved with electrode diameters of less than 10 μm, provided that impedance reduction measures have been implemented and provided that a set of requirements for signal amplification has been met.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2017, 1-4
Acquisition of bioelectrical signals with small electrodes
Although the mechanisms of recording bioelectrical signals from different types of electrogenic cells (neurons, cardiac cells etc.) by means of planar metal electrodes have been extensively studied, the recording characteristics and conditions for very small electrode sizes are not yet established. Here, we present a combined experimental and computational approach to elucidate, how the electrode size influences the recorded signals, and how inherent properties of the electrode, such as impedance, noise, and transmission characteristics shape the signal. We demonstrate that good quality recordings can be achieved with electrode diameters of less than 10 μm, provided that impedance reduction measures have been implemented and provided that a set of requirements for signal amplification has been met.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2017, 135-138
High-density mapping of brain slices using a large multi-functional high-density CMOS microelectrode array system
We present a CMOS-based high-density microelectrode array (HD-MEA) system that enables high-density mapping of brain slices in-vitro with multiple readout modalities. The 4.48×2.43 mm 2 array consists of 59,760 micro-electrodes at 13.5 μm pitch (5487 electrodes/mm 2 ). The overall system features 2048 action-potential, 32 local-field-potential and 32 current recording channels, 32 impedance-measurement and 28 neurotransmitter-detection channels and 16 voltage/current stimulation channels. The system enables real-time and label-free monitoring of position, size, morphology and electrical activity of brain slices.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2017, 135-138
High-density mapping of brain slices using a large multi-functional high-density CMOS microelectrode array system
We present a CMOS-based high-density microelectrode array (HD-MEA) system that enables high-density mapping of brain slices in-vitro with multiple readout modalities. The 4.48×2.43 mm 2 array consists of 59,760 micro-electrodes at 13.5 μm pitch (5487 electrodes/mm 2 ). The overall system features 2048 action-potential, 32 local-field-potential and 32 current recording channels, 32 impedance-measurement and 28 neurotransmitter-detection channels and 16 voltage/current stimulation channels. The system enables real-time and label-free monitoring of position, size, morphology and electrical activity of brain slices.
- Top Cited Papers
- 27 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 52 (6) , 1576-1590
In Vitro Multi-Functional Microelectrode Array Featuring 59 760 Electrodes, 2048 Electrophysiology Channels, Stimulation, Impedance Measurement, and Neurotransmitter Detection Channels
Biological cells are characterized by highly complex phenomena and processes that are, to a great extent, interdependent. To gain detailed insights, devices designed to study cellular phenomena need to enable tracking and manipulation of multiple cell parameters in parallel; they have to provide high signal quality and high-spatiotemporal resolution. To this end, we have developed a CMOS-based microelectrode array system for in vitro applications that integrates six measurement and stimulation functions, the largest number to date. Moreover, the system features the largest active electrode array area to date (4.48 × 2.43 mm 2 ) to accommodate 59760 electrodes, while its power consumption, noise characteristics, and spatial resolution (13.5-μm electrode pitch) are comparable to the best state-of-the-art devices. The system includes: 2048 action potential (AP, bandwidth: 300 Hz-10 kHz) recording units, 32 local-field-potential (LFP, bandwidth: 1 Hz-300 Hz) recording units, 32 current recording units, 32 impedance measurement units, and 28 neurotransmitter detection units, in addition to the 16 dual-mode voltage-only or current/voltage-controlled stimulation units. The electrode array architecture is based on a switch matrix, which allows for connecting any measurement/stimulation unit to any electrode in the array and for performing different measurement/stimulation functions in parallel.
- 27 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 52 (6) , 1576-1590
Top Cited PapersIn Vitro Multi-Functional Microelectrode Array Featuring 59 760 Electrodes, 2048 Electrophysiology Channels, Stimulation, Impedance Measurement, and Neurotransmitter Detection Channels
Biological cells are characterized by highly complex phenomena and processes that are, to a great extent, interdependent. To gain detailed insights, devices designed to study cellular phenomena need to enable tracking and manipulation of multiple cell parameters in parallel; they have to provide high signal quality and high-spatiotemporal resolution. To this end, we have developed a CMOS-based microelectrode array system for in vitro applications that integrates six measurement and stimulation functions, the largest number to date. Moreover, the system features the largest active electrode array area to date (4.48 × 2.43 mm 2 ) to accommodate 59760 electrodes, while its power consumption, noise characteristics, and spatial resolution (13.5-μm electrode pitch) are comparable to the best state-of-the-art devices. The system includes: 2048 action potential (AP, bandwidth: 300 Hz-10 kHz) recording units, 32 local-field-potential (LFP, bandwidth: 1 Hz-300 Hz) recording units, 32 current recording units, 32 impedance measurement units, and 28 neurotransmitter detection units, in addition to the 16 dual-mode voltage-only or current/voltage-controlled stimulation units. The electrode array architecture is based on a switch matrix, which allows for connecting any measurement/stimulation unit to any electrode in the array and for performing different measurement/stimulation functions in parallel.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2016, 136-139
2048 action potential recording channels with 2.4 μVrms noise and stimulation artifact suppression
Here, we present 2048 low-noise, low-offset, and low-power action-potential recording channels, integrated in a multi-functional high-density microelectrode array. A resistively loaded open-loop topology has been adapted for the first-stage amplifier to achieve 2.4 μVrms noise levels at low power consumption. Two novel pseudo-resistor structures have been used to realize very low HPF corner frequencies with small variations across all channels. The adjustability of pseudo resistors has been exploited to realize a "soft" reset technique that suppresses stimulation artifacts so that the amplifiers can recover from saturation within 200 μs. The chips were fabricated in a 0.18 μm 6M1P CMOS process, and measurement results are presented to show the performance of the proposed circuit structures and techniques.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2016, 136-139
2048 action potential recording channels with 2.4 μVrms noise and stimulation artifact suppression
Here, we present 2048 low-noise, low-offset, and low-power action-potential recording channels, integrated in a multi-functional high-density microelectrode array. A resistively loaded open-loop topology has been adapted for the first-stage amplifier to achieve 2.4 μVrms noise levels at low power consumption. Two novel pseudo-resistor structures have been used to realize very low HPF corner frequencies with small variations across all channels. The adjustability of pseudo resistors has been exploited to realize a "soft" reset technique that suppresses stimulation artifacts so that the amplifiers can recover from saturation within 200 μs. The chips were fabricated in a 0.18 μm 6M1P CMOS process, and measurement results are presented to show the performance of the proposed circuit structures and techniques.
- Open Access
- 1 January 2016
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 10
Highly Matched TO Pseudo-resistors for Multi-channel Neural Signal Recording Applications
Motivation To reduce drift and offset of electrodes, neural amplifiers usually employ high pass filters with very low corner frequencies (e.g., fHPF<10Hz). This approach requires huge on-chip resistances (~T½). To keep the silicon area small, "pseudo-resistors" (MOS transistors biased in the weak inversion region) are frequently used [1], but their resistance may considerably vary due to processing and fabrication spread, temperature fluctuations, and even different locations on the same chip may feature different properties. Here, specific new pseudo-resistor structures have been devised to achieve small fHPF variations. Material and Methods The new pseudo-resistors were implemented in a CMOS high-density MEA system incorporating 2048 readout channels [2]. Two different kinds of pseudo-resistor topologies were devised. For the 1st stage, open-loop amplifiers were used, while, for the 2nd stage closed-loop amplifiers were implemented. Aided by the current mirrors and level shifters, the first-order dependence of the overdrive voltages of the transistors inside RPR1 and RPR2 on their threshold voltages was cancelled out. Thus, RPR1 and RPR2 variations were substantially reduced, which lead to small fHPF variations. A wide range of resistances could also be realized by changing the bias currents, which could be digitally tuned with 7-bit current DACs implemented on-chip. Results High pass filter corner frequency (fHPF) of the the neural amplifiers tuned by pseudo-resistors were measured. The uniformity of fHPF showed the inter-channel matching of pseudo resistors across 2048 channels in the high and low frequency range. Conclusions Current-biased pseudo-resistors for neural signal recording applications are introduced in this work. The two new structures enable to realize very large resistances while keeping the silicon area small. Results on the transfer function of the neural amplifiers and the matching of the pseudo-resistors have been shown in this paper. The circuits were fabricated in 180nm 6M1P CMOS technology. References: [1] A. Tajalli, Y. Leblebici, Extreme Low-Power Mixed Signal IC Design - Subthreshold Source-Coupled Circuits, Springer, 2010. [2] V. Viswam, J. Dragas, A. Shadmani, Y. Chen, J. Müller, A. Stettler, A. Hierlemann,"Multi-functional microelectrode array system featuring 59760 electrodes, 2048 electrophysiology channels, impedance, and neurotransmitter measurement units", ISSCC 2016, Session 22.8, Digest of Technical Papers, pp. 394-396 (ISBN 978-1-4673-9467-3).
- 1 January 2016
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 10
Open AccessHighly Matched TO Pseudo-resistors for Multi-channel Neural Signal Recording Applications
Motivation To reduce drift and offset of electrodes, neural amplifiers usually employ high pass filters with very low corner frequencies (e.g., fHPF<10Hz). This approach requires huge on-chip resistances (~T½). To keep the silicon area small, "pseudo-resistors" (MOS transistors biased in the weak inversion region) are frequently used [1], but their resistance may considerably vary due to processing and fabrication spread, temperature fluctuations, and even different locations on the same chip may feature different properties. Here, specific new pseudo-resistor structures have been devised to achieve small fHPF variations. Material and Methods The new pseudo-resistors were implemented in a CMOS high-density MEA system incorporating 2048 readout channels [2]. Two different kinds of pseudo-resistor topologies were devised. For the 1st stage, open-loop amplifiers were used, while, for the 2nd stage closed-loop amplifiers were implemented. Aided by the current mirrors and level shifters, the first-order dependence of the overdrive voltages of the transistors inside RPR1 and RPR2 on their threshold voltages was cancelled out. Thus, RPR1 and RPR2 variations were substantially reduced, which lead to small fHPF variations. A wide range of resistances could also be realized by changing the bias currents, which could be digitally tuned with 7-bit current DACs implemented on-chip. Results High pass filter corner frequency (fHPF) of the the neural amplifiers tuned by pseudo-resistors were measured. The uniformity of fHPF showed the inter-channel matching of pseudo resistors across 2048 channels in the high and low frequency range. Conclusions Current-biased pseudo-resistors for neural signal recording applications are introduced in this work. The two new structures enable to realize very large resistances while keeping the silicon area small. Results on the transfer function of the neural amplifiers and the matching of the pseudo-resistors have been shown in this paper. The circuits were fabricated in 180nm 6M1P CMOS technology. References: [1] A. Tajalli, Y. Leblebici, Extreme Low-Power Mixed Signal IC Design - Subthreshold Source-Coupled Circuits, Springer, 2010. [2] V. Viswam, J. Dragas, A. Shadmani, Y. Chen, J. Müller, A. Stettler, A. Hierlemann,"Multi-functional microelectrode array system featuring 59760 electrodes, 2048 electrophysiology channels, impedance, and neurotransmitter measurement units", ISSCC 2016, Session 22.8, Digest of Technical Papers, pp. 394-396 (ISBN 978-1-4673-9467-3).