Jun Yeon Won
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jun Yeon Won has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Jae Sung Lee
Seoul National University
7 shared publications Guen Bae Ko
R&D Center, Brightonix Imaging Inc., Seoul
5 shared publicationsJeong-Whan Son
Brightonix Imaging Inc., Seoul, South Korea
5 shared publicationsJae Sung Lee
Department of Biomedical Sciences, Seoul National University College of Medicine, Seoul, 03080, Korea
4 shared publicationsMin Sun Lee
Nuclear Emergency and Environmental Protection Division, Korea Atomic Energy Research Institute, Daejeon, Republic of Korea
4 shared publicationsHyun Suk Yoon
Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul, 03080, Korea
3 shared publications
Latest Publications
- Open Access
- 27 February 2025
- Published by Association for Computing Machinery (ACM)
- p. 247-256
FPGA-Only Implementation of MIPI C-PHY Receiver Using Blind Oversampling CDR for CMOS Image Sensors
Field-programmable gate array (FPGA) is a preferred solution for a CMOS image sensor (CIS) automatic test equipment (ATE) because it provides fast upgradability for the timely testing of CIS products using a new interface protocol. However, implementing a Mobile Industry Processor Interface (MIPI) C-PHY receiver to receive images from the CIS in an FPGA can be challenging due to the use of three wires, three distinct voltage levels, and the requirements of fast clock data recovery (CDR) lock time and wide CDR tracking bandwidth. To overcome these challenges, we have developed an FPGA-only MIPI C-PHY receiver that utilizes a blind oversampling CDR technique, which offers fast CDR lock time and wide CDR bandwidth. We used an Altera Stratix 10 GX FPGA as an oversampling device by operating its transceiver in a lock-to-reference-clock mode. We developed a parallel gate-based clock recovery algorithm and a fork and join-based data decision algorithm. As a result, we were able to test CIS wafers at symbol rates of up to 3.5 Giga-symbols per second, achieving performance comparable to that of sophisticated ASIC-based CIS ATEs.
- 27 February 2025
- Published by Association for Computing Machinery (ACM)
- p. 247-256
Open AccessFPGA-Only Implementation of MIPI C-PHY Receiver Using Blind Oversampling CDR for CMOS Image Sensors
Field-programmable gate array (FPGA) is a preferred solution for a CMOS image sensor (CIS) automatic test equipment (ATE) because it provides fast upgradability for the timely testing of CIS products using a new interface protocol. However, implementing a Mobile Industry Processor Interface (MIPI) C-PHY receiver to receive images from the CIS in an FPGA can be challenging due to the use of three wires, three distinct voltage levels, and the requirements of fast clock data recovery (CDR) lock time and wide CDR tracking bandwidth. To overcome these challenges, we have developed an FPGA-only MIPI C-PHY receiver that utilizes a blind oversampling CDR technique, which offers fast CDR lock time and wide CDR bandwidth. We used an Altera Stratix 10 GX FPGA as an oversampling device by operating its transceiver in a lock-to-reference-clock mode. We developed a parallel gate-based clock recovery algorithm and a fork and join-based data decision algorithm. As a result, we were able to test CIS wafers at symbol rates of up to 3.5 Giga-symbols per second, achieving performance comparable to that of sophisticated ASIC-based CIS ATEs.
- 2 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 6 (6) , 690-696
Investigation of Electronic Signal Processing Chains for a Prototype TOF-PET System With 100-ps Coincidence Time Resolution
We have evaluated the coincidence time resolution (CTR) performance of four different mixed-signal front-end electronic readout configurations with the goal to achieve 100 picoseconds (ps) CTR. The proposed TOF-PET detector elements are based on two $3{\times } 3{\times }10$ mm 3 “fast LGSO” crystal segments, side coupled to linear arrays of $3{\times }3$ mm 2 silicon photomultipliers (SiPMs), to form a total crystal length of 20 mm. We studied multiple configurations and components for the front-end readout: 1) high speed radio frequency (RF) amplifiers; 2) an ASIC-based discriminator; 3) a combination of RF amplifier, balun transformer, and discriminator ASIC; and 4) combination of balun transformer and discriminator ASIC. Using two $3{\times } 3{\times }10$ mm 3 fast LGSO crystals side coupled to a linear array of three SiPMs, coincidence data were experimentally acquired for each readout configuration in combination with a low jitter field-programmable gate array (FPGA)-based time-to-digital converter (TDC). After evaluating the timing performance of the three readout schemes, the best CTR value of 99.4 ± 1.9 ps FWHM was achieved for configuration (3), which is more than 20 ps better than the results achieved using configurations (1), (2), and (4).
- 2 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 6 (6) , 690-696
Investigation of Electronic Signal Processing Chains for a Prototype TOF-PET System With 100-ps Coincidence Time Resolution
We have evaluated the coincidence time resolution (CTR) performance of four different mixed-signal front-end electronic readout configurations with the goal to achieve 100 picoseconds (ps) CTR. The proposed TOF-PET detector elements are based on two $3{\times } 3{\times }10$ mm 3 “fast LGSO” crystal segments, side coupled to linear arrays of $3{\times }3$ mm 2 silicon photomultipliers (SiPMs), to form a total crystal length of 20 mm. We studied multiple configurations and components for the front-end readout: 1) high speed radio frequency (RF) amplifiers; 2) an ASIC-based discriminator; 3) a combination of RF amplifier, balun transformer, and discriminator ASIC; and 4) combination of balun transformer and discriminator ASIC. Using two $3{\times } 3{\times }10$ mm 3 fast LGSO crystals side coupled to a linear array of three SiPMs, coincidence data were experimentally acquired for each readout configuration in combination with a low jitter field-programmable gate array (FPGA)-based time-to-digital converter (TDC). After evaluating the timing performance of the three readout schemes, the best CTR value of 99.4 ± 1.9 ps FWHM was achieved for configuration (3), which is more than 20 ps better than the results achieved using configurations (1), (2), and (4).
- 14 April 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (8) , 085005
Scalable electronic readout design for a 100 ps coincidence time resolution TOF-PET system
We have developed a scalable detector readout design for a 100 ps coincidence time resolution (CTR) time of flight (TOF) positron emission tomography (PET) detector technology. The basic scintillation detectors studied in this paper are based on 2 × 4 arrays of 3 × 3 × 10 mm 3 ‘fast-LGSO:Ce’ scintillation crystals side-coupled to 6 × 4 arrays of 3 × 3 mm 2 silicon photomultipliers (SiPMs). We employed a novel mixed-signal front-end electronic configuration and a low timing jitter Field Programming Gate Array-based time to digital converter for data acquisition. Using a 22 Na point source, >10 000 coincidence events were experimentally acquired for several SiPM bias voltages, leading edge time-pickoff thresholds, and timing channels. CTR of 102.03 ± 1.9 ps full-width-at-half-maximum (FWHM) was achieved using single 3 × 3 × 10 mm 3 ‘fast-LGSO’ crystal elements, wrapped in Teflon tape and side coupled to a linear array of 3 SiPMs. In addition, the measured average CTR was 113.4 ± 0.7 ps for the side-coupled 2 × 4 crystal array. The readout architecture presented in this work is designed to be scalable to large area module detectors with a goal to create the first TOF-PET system with 100 ps FWHM CTR.
- 14 April 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (8) , 085005
Scalable electronic readout design for a 100 ps coincidence time resolution TOF-PET system
We have developed a scalable detector readout design for a 100 ps coincidence time resolution (CTR) time of flight (TOF) positron emission tomography (PET) detector technology. The basic scintillation detectors studied in this paper are based on 2 × 4 arrays of 3 × 3 × 10 mm 3 ‘fast-LGSO:Ce’ scintillation crystals side-coupled to 6 × 4 arrays of 3 × 3 mm 2 silicon photomultipliers (SiPMs). We employed a novel mixed-signal front-end electronic configuration and a low timing jitter Field Programming Gate Array-based time to digital converter for data acquisition. Using a 22 Na point source, >10 000 coincidence events were experimentally acquired for several SiPM bias voltages, leading edge time-pickoff thresholds, and timing channels. CTR of 102.03 ± 1.9 ps full-width-at-half-maximum (FWHM) was achieved using single 3 × 3 × 10 mm 3 ‘fast-LGSO’ crystal elements, wrapped in Teflon tape and side coupled to a linear array of 3 SiPMs. In addition, the measured average CTR was 113.4 ± 0.7 ps for the side-coupled 2 × 4 crystal array. The readout architecture presented in this work is designed to be scalable to large area module detectors with a goal to create the first TOF-PET system with 100 ps FWHM CTR.
- Open Access
- 24 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 40 (6) , 1579-1590
Development and Initial Results of a Brain PET Insert for Simultaneous 7-Tesla PET/MRI Using an FPGA-Only Signal Digitization Method
In study, we developed a positron emission tomography (PET) insert for simultaneous brain imaging within 7-Tesla (7T) magnetic resonance (MR) imaging scanners. The PET insert has 18 sectors, and each sector is assembled with two-layer depth-of-interaction (DOI)-capable high-resolution block detectors. The PET scanner features a 16.7-cm-long axial field-of-view (FOV) to provide entire human brain images without bed movement. The PET scanner early digitizes a large number of block detector signals at a front-end data acquisition (DAQ) board using a novel field-programmable gate array (FPGA)-only signal digitization method. All the digitized PET data from the front-end DAQ boards are transferred using gigabit transceivers via non-magnetic high-definition multimedia interface (HDMI) cables. A back-end DAQ system provides a common clock and synchronization signal for FPGAs over the HDMI cables. An active cooling system using copper heat pipes is applied for thermal regulation. All the 2.17-mm-pitch crystals with two-layer DOI information were clearly identified in the block detectors, exhibiting a system-level energy resolution of 12.6%. The PET scanner yielded clear hot-rod and Hoffman brain phantom images and demonstrated 3D PET imaging capability without bed movement. We also performed a pilot simultaneous PET/MR imaging study of a brain phantom. The PET scanner achieved a spatial resolution of 2.5 mm at the center FOV (NU 4) and a sensitivity of 18.9 kcps/MBq (NU 2) and 6.19% (NU 4) in accordance with the National Electrical Manufacturers Association (NEMA) standards.
- 24 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 40 (6) , 1579-1590
Open AccessDevelopment and Initial Results of a Brain PET Insert for Simultaneous 7-Tesla PET/MRI Using an FPGA-Only Signal Digitization Method
In study, we developed a positron emission tomography (PET) insert for simultaneous brain imaging within 7-Tesla (7T) magnetic resonance (MR) imaging scanners. The PET insert has 18 sectors, and each sector is assembled with two-layer depth-of-interaction (DOI)-capable high-resolution block detectors. The PET scanner features a 16.7-cm-long axial field-of-view (FOV) to provide entire human brain images without bed movement. The PET scanner early digitizes a large number of block detector signals at a front-end data acquisition (DAQ) board using a novel field-programmable gate array (FPGA)-only signal digitization method. All the digitized PET data from the front-end DAQ boards are transferred using gigabit transceivers via non-magnetic high-definition multimedia interface (HDMI) cables. A back-end DAQ system provides a common clock and synchronization signal for FPGAs over the HDMI cables. An active cooling system using copper heat pipes is applied for thermal regulation. All the 2.17-mm-pitch crystals with two-layer DOI information were clearly identified in the block detectors, exhibiting a system-level energy resolution of 12.6%. The PET scanner yielded clear hot-rod and Hoffman brain phantom images and demonstrated 3D PET imaging capability without bed movement. We also performed a pilot simultaneous PET/MR imaging study of a brain phantom. The PET scanner achieved a spatial resolution of 2.5 mm at the center FOV (NU 4) and a sensitivity of 18.9 kcps/MBq (NU 2) and 6.19% (NU 4) in accordance with the National Electrical Manufacturers Association (NEMA) standards.
- 29 July 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (15) , 155007
Comparator-less PET data acquisition system using single-ended memory interface input receivers of FPGA
In this study, we propose a linear field-programmable gate array (FPGA)-based charge measurement method by combining a charge-to-time converter (QTC) with a single-ended memory interface (SeMI) input receiver. The QTC automatically converts the input charge into a dual-slope pulse, which has a width proportional to the input charge. Dual-slope pulses are directly digitized by the FPGA input/output (I/O) buffers configured with SeMI input receivers. A proof-of-concept comparator-less QTC/SeMI data acquisition (DAQ) system, consisting of 132 energy and 33 timing channels, was developed and applied to a prototype brain-dedicated positron emission tomography (PET) scanner. The PET scanner consisted of 14 sectors, each containing 2 × 1 block detectors, and each block detector yielded four energy signals and one timing signal. Because a single QTC/SeMI DAQ system can receive signals from up to eight sectors, two QTC/SeMI DAQ systems connected using high-speed gigabit transceivers were used to acquire data from the PET scanner. All crystals in the PET block detectors, consisting of dual-layer stacked lutetium oxyorthosilicate (LSO) scintillation crystal and silicon photomultiplier arrays, were clearly resolved in the flood maps with an excellent energy resolution. The PET images of hot-rod, cylindrical, and two-dimensional Hoffman brain phantoms were also acquired using the prototype PET scanner and two QTC/SeMI DAQ systems.
- 29 July 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (15) , 155007
Comparator-less PET data acquisition system using single-ended memory interface input receivers of FPGA
In this study, we propose a linear field-programmable gate array (FPGA)-based charge measurement method by combining a charge-to-time converter (QTC) with a single-ended memory interface (SeMI) input receiver. The QTC automatically converts the input charge into a dual-slope pulse, which has a width proportional to the input charge. Dual-slope pulses are directly digitized by the FPGA input/output (I/O) buffers configured with SeMI input receivers. A proof-of-concept comparator-less QTC/SeMI data acquisition (DAQ) system, consisting of 132 energy and 33 timing channels, was developed and applied to a prototype brain-dedicated positron emission tomography (PET) scanner. The PET scanner consisted of 14 sectors, each containing 2 × 1 block detectors, and each block detector yielded four energy signals and one timing signal. Because a single QTC/SeMI DAQ system can receive signals from up to eight sectors, two QTC/SeMI DAQ systems connected using high-speed gigabit transceivers were used to acquire data from the PET scanner. All crystals in the PET block detectors, consisting of dual-layer stacked lutetium oxyorthosilicate (LSO) scintillation crystal and silicon photomultiplier arrays, were clearly resolved in the flood maps with an excellent energy resolution. The PET images of hot-rod, cylindrical, and two-dimensional Hoffman brain phantoms were also acquired using the prototype PET scanner and two QTC/SeMI DAQ systems.
- 15 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (6) , 1401-1409
Highly Integrated FPGA-Only Signal Digitization Method Using Single-Ended Memory Interface Input Receivers for Time-of-Flight PET Detectors
We propose a new highly integrated FPGA-only signal digitization method for individual signal digitization of time-of-flight positron emission tomography (TOF PET). We configured I/O port of the FPGA with a single-ended memory interface (SeMI) input receiver. The SeMI is a single-ended voltage-referenced interface that has a common reference voltage per I/O Bank, such that each SeMI input receiver can serve as a voltage comparator. The FPGA-only digitizer that uses the single-ended input receivers does not require a separate digitizing integrated chip, and can obtain twice as many signals as that using LVDS input receivers. We implemented a highly integrated digitizer consisting of 82 energy and 82 timing channels using a 28-nm FPGA. The energy and arrival time were measured using a 625-ps binary counter, and a 10-ps TDC, respectively. We first measured the intrinsic characteristics of the proposed FPGA-only digitizer. The SeMI input receiver functioned as the voltage comparator without undesirable offset voltage. The standard deviation value of the time difference measured using two SeMI input receivers with respective TDCs was less than 14.6 ps RMS. In addition, we fed signals from the TOF PET detectors to the SeMI input receivers directly and collected data. The TOF PET detector consisted of a 3×3×20 mm3 LYSO crystal coupled with a silicon photomultiplier. The energy resolutions were 7.7% and 7.1% for two TOF PET detectors. The coincidence resolving time was 204 ps FWHM. The SeMI digitizer with a high-performance signal digitizer, processor, and high-speed transceivers provides a compact all-in-one data acquisition system.
- 15 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (6) , 1401-1409
Highly Integrated FPGA-Only Signal Digitization Method Using Single-Ended Memory Interface Input Receivers for Time-of-Flight PET Detectors
We propose a new highly integrated FPGA-only signal digitization method for individual signal digitization of time-of-flight positron emission tomography (TOF PET). We configured I/O port of the FPGA with a single-ended memory interface (SeMI) input receiver. The SeMI is a single-ended voltage-referenced interface that has a common reference voltage per I/O Bank, such that each SeMI input receiver can serve as a voltage comparator. The FPGA-only digitizer that uses the single-ended input receivers does not require a separate digitizing integrated chip, and can obtain twice as many signals as that using LVDS input receivers. We implemented a highly integrated digitizer consisting of 82 energy and 82 timing channels using a 28-nm FPGA. The energy and arrival time were measured using a 625-ps binary counter, and a 10-ps TDC, respectively. We first measured the intrinsic characteristics of the proposed FPGA-only digitizer. The SeMI input receiver functioned as the voltage comparator without undesirable offset voltage. The standard deviation value of the time difference measured using two SeMI input receivers with respective TDCs was less than 14.6 ps RMS. In addition, we fed signals from the TOF PET detectors to the SeMI input receivers directly and collected data. The TOF PET detector consisted of a 3×3×20 mm3 LYSO crystal coupled with a silicon photomultiplier. The energy resolutions were 7.7% and 7.1% for two TOF PET detectors. The coincidence resolving time was 204 ps FWHM. The SeMI digitizer with a high-performance signal digitizer, processor, and high-speed transceivers provides a compact all-in-one data acquisition system.
- 1 March 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (5) , 05NT03
Performance of a new accelerating-electrode-equipped fast-time-response PMT coupled with fast LGSO
In this study, we measured the performance of a newly developed Hamamatsu Photonics R13478 photomultiplier tube (PMT) and compared the results with those of an existing R9800 PMT. In R13478, an accelerating electrode is placed between the focusing electrode and first dynode for time resolution improvement through reduced transit time jitter. We investigated the time resolution dependence on the supply voltage and time pickoff method for R13478 and R9800 PMTs, each coupled with a 2.9 × 2.9 × 20 mm 3 fast LGSO:Ce (0.025 mol%) crystal. In addition, we measured the PMT time resolutions coupled with the crystals in edge and laid positions to determine the effects of the reduced position dependence of transit time in R13478. R13478 exhibited a better time performance than R9800 in various ways. The rise time of R13478 for our experimental setup was 1.54 ns, 100 ps shorter than that of R9800 because of the reduced transit time. Further, R13478 achieved a 169 ps single time resolution at the recommended supply voltage, while this value was 187 ps for R9800. The time resolution of R13478 was also significantly better for a low time pickoff threshold level and a high supplied voltage, which are conditions vulnerable to transit time jitter and noise, respectively. A considerable difference in time resolution was observed for the laid position (R13478: 144 ps; R9800: 167 ps), indicating that the accelerating electrode reduced spatial transit time difference. Overall, we showed the effects of the differentiated characteristics of R13478 PMT compared with R9800 and confirmed its excellent time performance. We suggest use of this device as a photodetector effective for fast timing applications such as time-of-flight positron emission tomography.
- 1 March 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (5) , 05NT03
Performance of a new accelerating-electrode-equipped fast-time-response PMT coupled with fast LGSO
In this study, we measured the performance of a newly developed Hamamatsu Photonics R13478 photomultiplier tube (PMT) and compared the results with those of an existing R9800 PMT. In R13478, an accelerating electrode is placed between the focusing electrode and first dynode for time resolution improvement through reduced transit time jitter. We investigated the time resolution dependence on the supply voltage and time pickoff method for R13478 and R9800 PMTs, each coupled with a 2.9 × 2.9 × 20 mm 3 fast LGSO:Ce (0.025 mol%) crystal. In addition, we measured the PMT time resolutions coupled with the crystals in edge and laid positions to determine the effects of the reduced position dependence of transit time in R13478. R13478 exhibited a better time performance than R9800 in various ways. The rise time of R13478 for our experimental setup was 1.54 ns, 100 ps shorter than that of R9800 because of the reduced transit time. Further, R13478 achieved a 169 ps single time resolution at the recommended supply voltage, while this value was 187 ps for R9800. The time resolution of R13478 was also significantly better for a low time pickoff threshold level and a high supplied voltage, which are conditions vulnerable to transit time jitter and noise, respectively. A considerable difference in time resolution was observed for the laid position (R13478: 144 ps; R9800: 167 ps), indicating that the accelerating electrode reduced spatial transit time difference. Overall, we showed the effects of the differentiated characteristics of R13478 PMT compared with R9800 and confirmed its excellent time performance. We suggest use of this device as a photodetector effective for fast timing applications such as time-of-flight positron emission tomography.
- 18 August 2017
- Published by Wiley in Medical Physics
- Vol. 44 (10) , 5314-5324
Proof-of-concept prototype time-of-flight PET system based on high-quantum-efficiency multianode PMTs
Time-of-flight (TOF) information in positron emission tomography (PET) scanners enhances the diagnostic power of PET scans owing to the increased signal-to-noise ratio of reconstructed images. There are numerous additional benefits of TOF reconstruction, including the simultaneous estimation of activity and attenuation distributions from emission data only. Exploring further TOF gains by using TOF PET scanners is important because it can broaden the applications of PET scans and expand our understanding of TOF techniques. Herein, we present a prototype TOF PET scanner with fine-time performance that can experimentally demonstrate the benefits of TOF information.A single-ring PET system with a coincidence resolving time of 360 ps and a spatial resolution of 3.1/2.2 mm (filtered backprojection/ordered-subset expectation maximization) was developed. The scanner was based on advanced high-quantum-efficiency (high-QE) multi-anode photomultiplier tubes (PMTs). The impact of its fine-time performance was demonstrated by evaluating body phantom images reconstructed with and without TOF information. Moreover, the feasibility of the scanner as an experimental validator of TOF gains was verified by investigating the improvement of images under various conditions, such as the use of joint estimation algorithms of activity and attenuation, erroneous data correction factors (e.g., without normalization correction), and incompletely sampled data.The prototype scanner showed excellent performance, producing improved phantom images, when TOF information was employed in the reconstruction process. In addition, investigation of the TOF benefits using the phantom data in different conditions verified the usefulness of the developed system for demonstrating the practical effects of TOF reconstruction.We developed a prototype TOF PET scanner with good performance and a fine-timing resolution based on advanced high-QE multi-anode PMTs and demonstrated its feasibility as an experimental validator of TOF gains, suggesting its usefulness for investigating new applications of PET scans and clarifying TOF techniques in detail. This article is protected by copyright. All rights reserved.
- 18 August 2017
- Published by Wiley in Medical Physics
- Vol. 44 (10) , 5314-5324
Proof-of-concept prototype time-of-flight PET system based on high-quantum-efficiency multianode PMTs
Time-of-flight (TOF) information in positron emission tomography (PET) scanners enhances the diagnostic power of PET scans owing to the increased signal-to-noise ratio of reconstructed images. There are numerous additional benefits of TOF reconstruction, including the simultaneous estimation of activity and attenuation distributions from emission data only. Exploring further TOF gains by using TOF PET scanners is important because it can broaden the applications of PET scans and expand our understanding of TOF techniques. Herein, we present a prototype TOF PET scanner with fine-time performance that can experimentally demonstrate the benefits of TOF information.A single-ring PET system with a coincidence resolving time of 360 ps and a spatial resolution of 3.1/2.2 mm (filtered backprojection/ordered-subset expectation maximization) was developed. The scanner was based on advanced high-quantum-efficiency (high-QE) multi-anode photomultiplier tubes (PMTs). The impact of its fine-time performance was demonstrated by evaluating body phantom images reconstructed with and without TOF information. Moreover, the feasibility of the scanner as an experimental validator of TOF gains was verified by investigating the improvement of images under various conditions, such as the use of joint estimation algorithms of activity and attenuation, erroneous data correction factors (e.g., without normalization correction), and incompletely sampled data.The prototype scanner showed excellent performance, producing improved phantom images, when TOF information was employed in the reconstruction process. In addition, investigation of the TOF benefits using the phantom data in different conditions verified the usefulness of the developed system for demonstrating the practical effects of TOF reconstruction.We developed a prototype TOF PET scanner with good performance and a fine-timing resolution based on advanced high-QE multi-anode PMTs and demonstrated its feasibility as an experimental validator of TOF gains, suggesting its usefulness for investigating new applications of PET scans and clarifying TOF techniques in detail. This article is protected by copyright. All rights reserved.
- 20 September 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (19) , 7113-7135
Delay grid multiplexing: simple time-based multiplexing and readout method for silicon photomultipliers
In this paper, we propose a fully time-based multiplexing and readout method that uses the principle of the global positioning system. Time-based multiplexing allows simplifying the multiplexing circuits where the only innate traces that connect the signal pins of the silicon photomultiplier (SiPM) channels to the readout channels are used as the multiplexing circuit. Every SiPM channel is connected to the delay grid that consists of the traces on a printed circuit board, and the inherent transit times from each SiPM channel to the readout channels encode the position information uniquely. Thus, the position of each SiPM can be identified using the time difference of arrival (TDOA) measurements. The proposed multiplexing can also allow simplification of the readout circuit using the time-to-digital converter (TDC) implemented in a field-programmable gate array (FPGA), where the time-over-threshold (ToT) is used to extract the energy information after multiplexing. In order to verify the proposed multiplexing method, we built a positron emission tomography (PET) detector that consisted of an array of 4 × 4 LGSO crystals, each with a dimension of 3 × 3 × 20 mm3, and one- to-one coupled SiPM channels. We first employed the waveform sampler as an initial study, and then replaced the waveform sampler with an FPGA-TDC to further simplify the readout circuits. The 16 crystals were clearly resolved using only the time information obtained from the four readout channels. The coincidence resolving times (CRTs) were 382 and 406 ps FWHM when using the waveform sampler and the FPGA-TDC, respectively. The proposed simple multiplexing and readout methods can be useful for time-of-flight (TOF) PET scanners.
- 20 September 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (19) , 7113-7135
Delay grid multiplexing: simple time-based multiplexing and readout method for silicon photomultipliers
In this paper, we propose a fully time-based multiplexing and readout method that uses the principle of the global positioning system. Time-based multiplexing allows simplifying the multiplexing circuits where the only innate traces that connect the signal pins of the silicon photomultiplier (SiPM) channels to the readout channels are used as the multiplexing circuit. Every SiPM channel is connected to the delay grid that consists of the traces on a printed circuit board, and the inherent transit times from each SiPM channel to the readout channels encode the position information uniquely. Thus, the position of each SiPM can be identified using the time difference of arrival (TDOA) measurements. The proposed multiplexing can also allow simplification of the readout circuit using the time-to-digital converter (TDC) implemented in a field-programmable gate array (FPGA), where the time-over-threshold (ToT) is used to extract the energy information after multiplexing. In order to verify the proposed multiplexing method, we built a positron emission tomography (PET) detector that consisted of an array of 4 × 4 LGSO crystals, each with a dimension of 3 × 3 × 20 mm3, and one- to-one coupled SiPM channels. We first employed the waveform sampler as an initial study, and then replaced the waveform sampler with an FPGA-TDC to further simplify the readout circuits. The 16 crystals were clearly resolved using only the time information obtained from the four readout channels. The coincidence resolving times (CRTs) were 382 and 406 ps FWHM when using the waveform sampler and the FPGA-TDC, respectively. The proposed simple multiplexing and readout methods can be useful for time-of-flight (TOF) PET scanners.
- 7 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 65 (7) , 1678-1689
Time-to-Digital Converter Using a Tuned-Delay Line Evaluated in 28-, 40-, and 45-nm FPGAs
This paper proposes a bin-width tuning method for a field-programmable gate array (FPGA)-based delay line for a time-to-digital converter (TDC). Changing the hit transitions and sampling patterns of the carry chain considering delays of the sum and carry-out bins can improve the bin-width uniformity and thus measurement precision. The proposed sampling method was evaluated and compared with the ordinary tapped-delay-line (TDL) method in three different types of FPGAs: Kintex-7, Virtex-6, and Spartan-6. The linearity, equivalent bin width, and measurement precision improved for all the evaluated FPGAs by adopting the proposed method. The measurement precision obtained using the simple TDL architecture is comparable with other complex TDC architectures. In addition, the proposed method improves bin-width uniformity and measurement precision while maintaining the advantages of TDL TDCs, that is, fast conversion rate and small resource usage. Furthermore, the enhanced linearity of the delay line can also improve other carry-chain-based FPGA-TDCs.
- 7 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 65 (7) , 1678-1689
Time-to-Digital Converter Using a Tuned-Delay Line Evaluated in 28-, 40-, and 45-nm FPGAs
This paper proposes a bin-width tuning method for a field-programmable gate array (FPGA)-based delay line for a time-to-digital converter (TDC). Changing the hit transitions and sampling patterns of the carry chain considering delays of the sum and carry-out bins can improve the bin-width uniformity and thus measurement precision. The proposed sampling method was evaluated and compared with the ordinary tapped-delay-line (TDL) method in three different types of FPGAs: Kintex-7, Virtex-6, and Spartan-6. The linearity, equivalent bin width, and measurement precision improved for all the evaluated FPGAs by adopting the proposed method. The measurement precision obtained using the simple TDL architecture is comparable with other complex TDC architectures. In addition, the proposed method improves bin-width uniformity and measurement precision while maintaining the advantages of TDL TDCs, that is, fast conversion rate and small resource usage. Furthermore, the enhanced linearity of the delay line can also improve other carry-chain-based FPGA-TDCs.