JSJavier Samanes

Javier Samanes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Javier Samanes has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Torque Preservation in DFIG Systems During Voltage Dips With Modulated Stator-Connected Dynamic Braking Resistor

    by Filip Baum, Jesus Lopez, Javier Samanes, Jan Bauer

    This article proposes a novel approach to enhancing the low-voltage ride-through capability of doubly-fed induction generator wind turbines using a dynamically modulated braking resistor (DBR) connected in series with the stator windings. Unlike conventional DBR-based methods that focus primarily on mitigating electrical transients, the proposed approach emphasizes maintaining the generator’s electromagnetic torque at its prefault level during grid voltage dips. The DBR resistance is calculated in real time based on analytical expressions derived from the system’s model. By properly selecting the DBR resistance during the fault, the excess mechanical power that cannot be transferred to the grid is dissipated within the resistor, allowing the generator torque to remain constant during the fault, which helps maintain rotor speed and mitigate electrical transients. The proposed strategy is validated through both simulation and experimental results under symmetrical fault conditions, demonstrating superior torque stability, reduced current transients, and improved postfault recovery compared to fixed-resistance DBR schemes.


  • Single-Loop Droop Control Strategy for a Grid-Connected DFIG Wind Turbine

    by Iker Oraa, Javier Samanes, Jesus Lopez, Eugenio Gubia

    When grid-forming droop control strategies are implemented in grid-connected power converters, two control strategies are widely used: the single-loop and multiloop droop controls. However, only multiloop droop control strategies with inner control loops have been implemented in doubly fed induction generator (DFIG)-based wind turbines so far. This article proposes the application of a single-loop droop control strategy to a DFIG wind turbine, which has not been previously explored or implemented. As shown in the article, the application of the conventional droop control without inner control loops to DFIG-based wind power systems does not ensure a stable response. After modeling the system dynamics and evaluating its stability, two causes of instability have been identified: a resonance at the rotor electrical frequency relevant at high slips and a phase margin reduction at low slips. To solve these instability issues two control solutions are proposed: the emulation of a virtual resistor and a phase rotation. The proposed control strategy allows stabilizing the system and achieving a fast and damped dynamic response. The effectiveness of the proposed control strategy is validated by experimental results.


  • Selective Harmonic Mitigation: Limitations of Classical Control Strategies and Benefits of Model Predictive Control

    by Leyre Rosado, Javier Samanes, Eugenio Gubia, Jesus Lopez

    Selective harmonic mitigation pulsewidth modulation (SHMPWM) combined with model predictive control (MPC) is a promising approach for grid-connected power converters. SHMPWM can guarantee grid code compliance in steady state, e.g. grid harmonic injection, with a reduced output converter filter, while MPC improves dynamic response and allows grid code compliance in the event of grid transients. This paper presents a survey of the MPC strategies already published in the literature developed for their use with SHMPWM. The existing strategies fall into two categories: direct model predictive control with an implicit selective harmonic mitigation modulator, and direct model predictive control based on finite control set (FCS-MPC). One representative control strategy of each group is compared to each other and to the performance of classical proportional- integral (PI) controllers combined with SHMPWM. The goal is to identify the potential benefits of MPC for grid-connected power converters, and determine the main advantages and limitations of the two selected state-of-the-art control strategies. Their performance is assessed through Hardware-in-the-Loop (HIL) experimental results in terms of real-time implementation, harmonic content grid code compliance, dynamic response and performance under grid transients.


  • Deadbeat Voltage Control for a Grid-Forming Power Converter With LCL Filter

    by Javier Samanes, Leyre Rosado, Eugenio Gubia, Jesus Lopez, Marcelo A. Perez

    Grid-forming power converters are controlled as voltage sources to regulate the grid voltage and frequency. These converters can increase power system strength if they impose a voltage waveform resilient to grid transients. For this reason, in this paper, we propose a deadbeat control strategy of the capacitor voltage for high power converters with $LCL$ filter. To damp the LCL resonant poles, an active damping strategy is developed, based on a modification of the deadbeat control law. With this purpose, a notch filter is applied to the electrical variables allowing to emulate different damping resistances for the fundamental component and the harmonics. As a result, the active damping does not introduce tracking errors of the fundamental frequency component, while it provides damping to the filter resonance. The proposed strategy does not require knowledge of the grid impedance, an interesting feature in grid-connected power converters because the grid impedance is generally unknown. Experimental results validate the proposed strategy.


  • Open Access

    Modeling of a Droop-Controlled Grid-Connected DFIG Wind Turbine

    by Iker Oraa, Javier Samanes, Jesus Lopez, Eugenio Gubia

    Traditionally, to characterize the response of droop-controlled systems RMS models have been used. However, as it is demonstrated in this work, when droop control is applied to doubly-fed induction generators, RMS models do not allow to predict the system stability and dynamic response. Thus, in this article, a linearized small-signal model that overcomes the limitations of RMS models is presented. The proposed model is validated by simulation in MATLAB/Simulink demonstrating that it allows to accurately analyze the stability and dynamic response of the system under study. This model is an interesting tool that can be used in future works to design and adjust grid-forming controllers for doubly-fed induction generators.


  • Robust Active Damping Strategy for DFIG Wind Turbines

    by Leyre Rosado, Javier Samanes, Eugenio Gubía, Jesús López

    Doubly fed induction generators (DFIGs) with an LCL filter are widely used for wind power generation. In these energy conversion systems, there is an interaction between the grid-side converter (GSC) and the rotor-side converter (RSC) control loops, the generator and the LCL filter that must be properly modeled. Such interaction between the GSC and the RSC proves to have a significant influence on the stability. Several active damping (AD) methods for grid-connected converters with an LCL filter have been proposed, nevertheless, the application of these techniques to a DFIG wind turbine is not straightforward, as revealed in this article. To achieve a robust damping irrespective of the grid inductance, this article proposes an AD strategy based on the capacitor current feedback and the adjustment of the control delays to emulate a virtual impedance, in parallel with the filter capacitor, with a dominant resistive component in the range of possible resonance frequencies. This work also proves that, by applying the AD strategy in both converters simultaneously, the damping of the system resonant poles is maximized when a specific value of the grid inductance is considered. Experimental results show the interaction between the GSC and the RSC and validate the proposed AD strategy.


  • Open Access

    Control Design and Stability Analysis of Power Converters: The Discrete Generalized Bode Criterion

    by Andoni Urtasun, Javier Samanes, Ernesto L. Barrios, Pablo Sanchis

    For the controller design and stability analysis of power electronic converters, the Bode stability criterion and its subsequent revisions are the most practical tools. However, even though the control of the power converter is usually implemented in a microprocessor, none of these methods is infallible when applied to a discrete system. This article therefore proposes a new stability criterion, named the Discrete Generalized Bode Criterion (DGBC). This method is based on the Nyquist criterion but developed from the open-loop Bode diagram, evaluated also at 0 Hz and at the Nyquist frequency. The proposed criterion combines the advantages of the Nyquist and Bode criteria, since it is always applicable and provides an interesting and useful tool for the controller design process. The method is applied to design an active damping control of an inverter with LCL filter, showing how the proposed criterion accurately predicts stability, in contrast to the existing Bode criteria. The theoretical analysis is validated through experimental results performed with a three-phase inverter and an LCL filter.


  • Open Access

    Sub-Synchronous Resonance Damping Control Strategy for DFIG Wind Turbines

    by Javier Samanes, Eugenio Gubia, Jesus Lopez, Rolando Burgos

    Doubly-fed induction generator (DFIG) wind turbines connected to capacitive series-compensated transmission lines are prone to exhibit oscillatory behavior. The phenomena is called sub-synchronous resonances (SSRs), as these oscillations occur at frequencies below the fundamental component. This paper first develops a modeling methodology for DFIG wind turbines, based on impedance matrices, that is applied to model a real wind farm where SSRs were reported. The stability analysis performed shows how the interaction between the grid-side converter and the rotor-side converter contribute to the instability of DFIG wind energy conversion systems connected to series compensated grids. With this model, we propose a simple sub-synchronous resonance control strategy based on an orthogonal proportional action applied to the rotor currents, and a variable gain in the PI controller adjusted as a function of the DFIG rotational speed. This control strategy depends only on the rotor currents, which are local and already measured variables in any DFIG wind turbine, and is implemented in the rotor side converter, so it does not imply an additional cost at wind farm or wind turbine level and can be applied to any DFIG wind energy conversion system (WECS). Additionally, it proves to be robust for any line impedance series compensation level, and it does not need real-time information concerning the grid at which the wind turbine is connected, or its parameters. A real case study is considered, where the sub-synchronous resonance damping strategy presented in this work is able to stabilize the system for every possible line impedance compensation level.


  • Common-Mode and Phase-to-Ground Voltage Reduction in Back-to-Back Power Converters With Discontinuous PWM

    by Javier Samanes, Eugenio Gubia, Xabier Juankorena, Carlos Girones

    Discontinuous space vector pulse-width modulation (DSVPWM) techniques are an interesting option for three-phase two-level power converters when efficiency is a key factor. Such is the case of back-to-back (B2B) power converters used mainly in wind energy conversion systems (WECS) and electrical drives. The application of DSVPMWs to B2B converters, increases the common-mode (CM) and phase-to-ground (PG) voltages by a 50%, compared to conventional space vector pulse width modulation (SVPWM7). Higher CM and PG voltages cause bearing currents and insulation stress, which reduce system reliability. In this paper, this problem is addressed and two DSVPWM strategies are presented to reduce the CM and PG voltages in B2B power converters. In the first proposal, the CM and PG are both limited to the same values as the conventional SVPWM7 without introducing additional commutations. In the second proposal, a further modification is added to reduce the CM by 50%, compared to the SVPWM7, although this modulation strategy eventually requires two additional commutations in certain periods. Experimental and simulation results validate the performance of the proposed strategies.


  • Control Design and Stability Analysis of Power Converters: The MIMO Generalized Bode Criterion

    by Javier Samanes, Andoni Urtasun, Ernesto L. Barrios, David Lumbreras, Jesus Lopez, Eugenio Gubia, Pablo Sanchis

    Three-phase dynamic systems and multiphase generators are frequently modeled and controlled in the synchronous reference frame. To properly model the cross-coupling terms in this reference frame, complex vector theory and transfer function matrices are commonly applied, obtaining multiple-input multiple output (MIMO) dynamic models. The stability of MIMO systems can be assessed through the Nyquist Generalized Stability Criterion. However, the use of the Nyquist diagram complicates the controller design. The Bode diagram is a more intuitive tool for the controller design, however, the Bode Stability Criterion is not applicable to MIMO systems. In this paper, the MIMO Generalized Bode Criterion is proposed. Since this stability criterion is based on the Nyquist Generalized Stability Criterion it can be applied to any system. Furthermore, it is simple to use, as it only requires information contained in the open-loop transfer matrix and the Bode diagram. The proposed stability criterion thus offers an interesting tool for the controller design procedure in MIMO systems, as it is shown in in this paper for two common applications: the current control loop of a power converter, a 2×2 system, and the current control loop of two independent power converters in parallel, a 4×4 system.