FSFadia Sebaaly

Fadia Sebaaly

*This is an algorithmically generated author record based on publicly available information.

Fadia Sebaaly has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Z Packed U-Cell Modular Multilevel Converter for STATCOM Applications

    by Sandy Atanalian, Fadia Sebaaly, Rawad Zgheib, Kamal Al-Haddad

    The Modular Multilevel Converter (MMC) is a promising topology for STATCOM applications due to its key features, such as modularity, scalability, and reduced harmonic content. Increasing the number of voltage levels in MMC reduces harmonics but simultaneously increases the number of submodules (SMs) per arm, leading to larger sizes and higher costs, which presents a challenge. To address this, this article introduces a novel 17-level MMC-STATCOM based on the Z Packed U-Cell (ZPUC) converter as its SM, which enables the generation of more voltage levels with fewer components and reduced harmonic content, offering significant advantages in terms of size and cost. Given the complex structure of the proposed converter and the associated challenges in building a physical prototype, real-time (RT) simulation using FPGA technology is employed for validation. The key contributions include integrating the ZPUC-SM into a three-phase STATCOM for the first time and adapting the converter model and its control system to RT tools, including RT-LAB with an electric hardware solver for FPGA execution. In addition, capacitor voltage balancing and energy sorting algorithms are integrated within Phase-Shift Pulse Width Modulation, eliminating the need for an additional controller while maintaining the floating capacitors of ZPUC-SMs balanced and regulated. The specifications of the proposed converter are defined, the mathematical model and control system are derived, and a real-time implementation based on CPU and FPGA execution is built to verify the scheme. The obtained RT simulation results provide practical evidence confirming the effective operation of the proposed scheme in VAR compensation mode.

  • Three-Phase ZPUC-MMC Grid Connected Converter

    by Sandy Atanalian, Fadia Sebaaly, Saeed Arazm, Rawad Zgheib, Kamal Al-Haddad, Hadi Y. Kanaan

    Modular Multilevel Converter (MMC) is a promising topology that gained lot of interest in medium-voltage grid-connected applications due to its modularity, scalability, and adaptability. Although increasing the number of submodules per arm leads to a higher number of voltage levels and better waveforms quality, the size and then the cost of the converter remains a challenge. Therefore, a trade-off between topology complexity and power quality exists. This paper proposes an MMC based on Z Packed U-Cell converter as Submodule (ZPUC-SM) to generate a higher number of voltage levels with reduced number of SMs. When compared to HB-MMC, this topology features reduced components count for generating the same voltage levels. Thus, the candidate topology is considered to be a promising solution for medium-voltage applications connecting the utility. This paper details the design, modeling and control of ZPUC-MMC operating as a three-phase grid-connected converter. The controller task is to regulate output current to fulfill grid connectivity requirements. A Phase shifted-PWM with an integrated voltage balancing algorithm takes in action of controlling the three-capacitors voltages of each arm. Thus, no additional voltage controllers are required. The performance of the proposed converter along with its control system are validated with MATLAB/SIMULINK, and the simulation results validate the robustness and effectiveness of the proposed control during both steady-state and dynamic operations.


  • Multilevel Switching-Mode Operation of Finite-Set Model Predictive Control for Grid-Connected Packed E-Cell Inverter

    by Fadia Sebaaly, Mohammad Sharifzadeh, Hadi Youssef Kanaan, Kamal Al-Haddad

    This paper proposes a Modified Finite-Set Model Predictive Control (M-FS-MPC) for multilevel switching mode operation of grid-connected nine-level Packed E-Cell (PEC9) inverter. With single-DC source, six power switches, back-to-back connected switches as bidirectional and two capacitors horizontally extended, PEC9 inverter topology has remarkably reduced components count. PEC prominent feature is the capability to switch among different multilevel voltage; nine- seven- or five- level under faulty switch case without any structure modification and only if the controller is appropriately designed. M-FS-MPC is proposed to operate grid-connected PEC with multilevel switching mode under bidirectional switch fault operation. Switching among five- seven- or nine-level voltages is attained by proper DC capacitors voltages regulation whereas the desired current injection with low THD and requested power factor for addressing grid connectivity applications is guaranteed. System discrete model is developed and experimental results verify the performance and robustness of M-FS-MPC in targeting the capability of PEC multilevel switching mode operation and grid connectivity requirements in both steady and transient states.


  • Comparative Analysis of Predictive Control Systems Applied to a Grid-Tied NPC Inverter

    by Raghda Hariri, Fadia Sebaaly, Hadi Y. Kanaan

    In this paper, two control methods based on predictive technique have been proposed for NPC grid tied inverter. The first method is the well-known Finite Set Model Predictive Controller (FS-MPC). It deals with the finite number of the converter switching states that optimizes a predefined cost function. The absence of the modulator in steady state performance results in generating variable switching frequency increasing system losses. Model Predictive Control with constant switching frequency (MPC-CSF), is introduced and discussed. The algorithm of MPC-CSF works in finding the optimal angle of the voltage vector in the first loop and then in finding the optimal amplitude of the voltage vector in the second loop. Simulations for the two proposed concepts were performed on Matlab/Simulink in order to verify their performance. Both methods are compared with respect to their complexity, simplicity, ability to inject current with low THD, dynamic response, and capacitor voltage balance.


  • Design of an Artificial Neural Network Control Based on Levenberg-Marquart Algorithm for Grid-Connected Packed U-Cell Inverter

    by Mohammad Babaie, Fadia Sebaaly, Mohammad Sharifzadeh, Hadi Y. Kanaan, Kamal Al-Haddad

    In this paper an Artificial Neural Network (ANN) controller based on Levenberg-Marquart algorithm is designed and applied to a five-level sensor-less Packed U-cell (PUC5) inverter operating as grid connected mode. The advantage of the proposed design is that there is no longer required to the conventional parameters tuning snag confronted with the traditional Proportional Integral (PI) method. An offline algorithm takes in action of the controller parameters tuning calculation. The proposed ANN regulates the grid line current while the DC bus voltage is maintained constant with no need of regulator as the capacitor is self-voltage balanced in PUC5 topology. The overall design is simple as less tuning, sensors and regulators are requested compared to the conventional PI compensator case. Simulation results on MATLAB/Simulink are conducted to validate the performance of the controller in both steady and dynamic state where low Total Harmonic Distortion (THD) of the line current and high dynamic system response can be identified.


  • Experimental Design of Fixed Switching Frequency Model Predictive Control for Sensorless Five-Level Packed U-Cell Inverter

    by Fadia Sebaaly, Hani Vahedi, Hadi Youssef Kanaan, Kamal Al-Haddad

    In this paper a fixed switching frequency Model Predictive Current Controller is designed and implemented on a sensor-less five-level Packed U-Cell (PUC5) inverter interfacing the utility. The predictive control methodology is based on a voltage vector generation technique for the cost function optimization by nullifying its derivative. The aim of the controller is to allow a fixed-frequency operation with no iterations while operating as a utility line current regulator. A pulse width modulator based on employing PUC5 redundant switching states takes the action of fixing the PUC5 auxiliary dc bus capacitor voltage to its desired level with no necessity of a regulator; the overall technique reduces system complexity with less sensors and no loops in the predictive algorithm making it suitable for industrial applications. System discrete model is developed and experimental results verify the performance of the designed controller in making a fast response in regulating the grid current and balancing the capacitor voltage.


  • Fixed switching frequency model predictive based controller for sensor-less five-level Packed U-cell (PUC5) single phase inverter

    by F. Sebaaly, H. Vahedi, H. Y. Kanaan, K. Al-Haddad

    In this paper, a new control design is developed for the Packed U-Cells (PUC) inverter. A fixed-switching frequency Model Predictive-based (MPC) algorithm is introduced for the sensor-less five-level (PUC5) inverter to regulate the current injected to the utility when it operates in grid connection mode. The proposed method generates the candidate vector that minimizes the well-known Finite Set Model Predictive (FS-MPC) cost function. Besides, the sensor-less voltage control of PUC5 takes in action of stabilizing DC capacitor voltages with no need of additional regulator. Less complexity with no sensors, nor required iterations are obtained. Discrete system model has been introduced and developed. Simulation results on MATLAB/Simulink are provided to confirm the effectiveness and robustness of the proposed algorithm.


  • Novel Current Controller Based on MPC With Fixed Switching Frequency Operation for a Grid-Tied Inverter

    by Fadia Sebaaly, Hani Vahedi, Hadi Y. Kanaan, Kamal Al-Haddad

    In this paper, a novel controller based on the predictive technique has been introduced for a neutral-point-clamped grid-tied inverter. The aim of the developed method is to achieve a constant system switching frequency operation. The proposed method generates the voltage vector by nullifying the derivative of the cost function of a finite-set model predictive controller. The developed controller takes in action of injecting the desired grid current while a closed-loop space vector modulator regulates the capacitors voltages. A comparative study with a similar model predictive algorithm with constant switching frequency (MPC-CSF) is introduced and discussed in terms of computational complexity. Experimental results are provided to verify the performance and robustness of the new method over MPC-CSF with its ability of injecting a very low total harmonic distortion to the grid with almost unity power factor during normal and transient operations.


  • New voltage vector generation method for a MPC algorithm with constant switching frequency operation

    by Fadia Sebaaly, Hadi Y. Kanaan

    This paper Introduces a novel voltage vector generation method for fixed switching frequency scheme of a finite-control set model predictive control (FS-MPC). The main feature of the proposed work is to search the optimum voltage vector responsible of minimizing the cost function. A novel algorithm based on two searching loops is introduced, the first loop optimizes the voltage vector angle while the second one defines its correspondent modulus. The optimal combination is then generated into a FS-MPC algorithm to control a 3L-NPC grid-tied inverter. A closed-loop space vector modulator takes in action of firing the switches and balancing the two DC capacitors of the inverter. The overall discrete model in (dq) frame is developed. The design of the proposed algorithm is then detailed. Simulation results verifies the effectiveness of the proposed method in fulfilling grid requirements during normal operation and against external disturbances.


  • MPC based on balanced positive-sequence extraction strategy for grid-tied converter control

    by A. Kanaan, F. Sebaaly, H. Y. Kanaan

    The massive penetration of renewable energy sources in grid-tied systems has boosted the improvement of conventional control solutions to fulfill the requirements demanded during grid faults. In this paper, balanced positive-sequence reference extraction method (BPSC) is proposed with the predictive technique to control the 3L-NPC inverter under grid sags. Only positive sequence extraction is needed to inject properly the generated reference currents through MPC controller. Moreover, no additional phase-locked loop synchronization technique is required. A Second Order Generalized Integrator filter is added for voltage sequences extraction. The overall discrete system model is developed. Simulation results show the advantages of the proposed algorithm in terms of injecting a set of balanced grid current with low harmonic content during grid sags.