Junsong Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Junsong Zheng has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
Hui Huang
Department of Clinical and Military Laboratory Medicine, College of Medical Laboratory Science
17 shared publicationsLichao Fang
Department of Clinical and Military Laboratory Medicine, College of Pharmacy and Laboratory Medicine, Third Military Medical University (Army Medical University), No. 30 Gaotanyan Street, Shapingba District, Chongqing 400038, China
15 shared publicationsChenghong Li
Department of Clinical and Military Laboratory Medicine, College of Medical Laboratory Science
10 shared publicationsHuamin Liu
Department of Clinical and Military Laboratory Medicine, College of Medical Laboratory Science
10 shared publicationsJun Deng
Department of Clinical and Military Laboratory Medicine, College of Medical Laboratory Science, Army Medical University, Chongqing, China
9 shared publicationsLina Wang
Department of Clinical and Military Laboratory Medicine, College of Medical Laboratory Science, Army Medical University, 400038, Chongqing, China
7 shared publications
Latest Publications
- 3 February 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (6) , 4666-4674
Application of an l -Cysteine-Enhanced Ag NCs@C NF Amplification-Free ECL Biosensor for miRNA
Even though a lot of research shows that blood miRNA-155 is a specific, early stage biomarker for sepsis and associated consequences, current detection techniques need to be improved. In this work, we created Ag NCs@C NF nanocomposite luminous materials using carbon nanoflowers (C NFs) as a framework. The Ag NCs@C NF signal is much improved by the addition of l-cysteine (l-Cys), causing the biosensor response to change from "ON" to "super ON." By modifying the hammerhead ribozyme (HHR) into an artificial allosteric blocking ribozyme (BRmiRNA-155) that specifically binds to miRNA-155, this ribozyme rapidly and repeatedly cleaves locked crRNA in the presence of miRNA-155, enabling non-nucleic acid amplification-based miRNA detection. This amplification-free electrochemiluminescence (ECL) biosensor system detects miRNA-155 within a range of 100 aM-100 nM, with a limit of detection (LOD) of 47.4 aM. Additional tests demonstrating specificity, sensitivity, stability, and reproducibility also yielded excellent performance. This technology opens new avenues for the early diagnosis of sepsis and its complications.
- 3 February 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (6) , 4666-4674
Application of an l -Cysteine-Enhanced Ag NCs@C NF Amplification-Free ECL Biosensor for miRNA
Even though a lot of research shows that blood miRNA-155 is a specific, early stage biomarker for sepsis and associated consequences, current detection techniques need to be improved. In this work, we created Ag NCs@C NF nanocomposite luminous materials using carbon nanoflowers (C NFs) as a framework. The Ag NCs@C NF signal is much improved by the addition of l-cysteine (l-Cys), causing the biosensor response to change from "ON" to "super ON." By modifying the hammerhead ribozyme (HHR) into an artificial allosteric blocking ribozyme (BRmiRNA-155) that specifically binds to miRNA-155, this ribozyme rapidly and repeatedly cleaves locked crRNA in the presence of miRNA-155, enabling non-nucleic acid amplification-based miRNA detection. This amplification-free electrochemiluminescence (ECL) biosensor system detects miRNA-155 within a range of 100 aM-100 nM, with a limit of detection (LOD) of 47.4 aM. Additional tests demonstrating specificity, sensitivity, stability, and reproducibility also yielded excellent performance. This technology opens new avenues for the early diagnosis of sepsis and its complications.
- 29 November 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1384, 344968
Photoelectrochemical detection of epigenetic 5-hydroxymethylcytosine based on Cu2O@CuO@Ag and self-triggered isothermal amplification
- 29 November 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1384, 344968
Photoelectrochemical detection of epigenetic 5-hydroxymethylcytosine based on Cu2O@CuO@Ag and self-triggered isothermal amplification
- Open Access
- 15 May 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (20) , 10841-10848
An Efficient Electrochemiluminescence Biosensor Based on Ru(bpy) 3 2+ @AuNPs@SWCNTs for miRNAs Detection Using a Dual Engine-Triggered DNA Walker
The diagnosis and treatment of acute pancreatitis remain challenging due to the limitations of diagnostic methods, which often result in delayed treatment and suboptimal outcomes. This underscores the need for innovative diagnostic strategies to enable early detection and improve therapeutic interventions. Electrochemiluminescence (ECL)-based biosensors have emerged as a promising solution, offering advantages such as cost-effectiveness, ease of use, and high sensitivity. This study introduces an innovative ECL biosensor design, which incorporates a DNA tetrahedron as a structural scaffold, a double swing arm mechanism for enhanced motion control, and a track-based signal regulation system. This design significantly enhanced the operating efficiency and controllability of DNA walkers. The system utilizes ferrocene (Fc) as a signal quenching agent, with its electrochemical signal restored upon interaction with miRNA24-3p, a biomarker for acute pancreatitis. The platform features a composite luminescent material─tris(2,2′-bipyridine) dichlororuthenium(II)@goldnanoparticles@single-walled carbon nanotubes (Ru(bpy)32+@AuNPs@SWCNTs)─and employs persulfate as a coreactant. Under optimized conditions, this design demonstrated a wide dynamic range (10–15 M to 10–6 M) and an ultralow detection limit of approximately 60 aM for miRNA 24-3p. Additionally, it exhibited excellent specificity, reproducibility, and stability. These findings underscore the potential of this application of this ECL-based platform to revolutionize the clinical diagnosis of acute pancreatitis by enabling more timely and accurate interventions while paving the way for advancements in diagnostic technologies.
- 15 May 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (20) , 10841-10848
Open AccessAn Efficient Electrochemiluminescence Biosensor Based on Ru(bpy) 3 2+ @AuNPs@SWCNTs for miRNAs Detection Using a Dual Engine-Triggered DNA Walker
The diagnosis and treatment of acute pancreatitis remain challenging due to the limitations of diagnostic methods, which often result in delayed treatment and suboptimal outcomes. This underscores the need for innovative diagnostic strategies to enable early detection and improve therapeutic interventions. Electrochemiluminescence (ECL)-based biosensors have emerged as a promising solution, offering advantages such as cost-effectiveness, ease of use, and high sensitivity. This study introduces an innovative ECL biosensor design, which incorporates a DNA tetrahedron as a structural scaffold, a double swing arm mechanism for enhanced motion control, and a track-based signal regulation system. This design significantly enhanced the operating efficiency and controllability of DNA walkers. The system utilizes ferrocene (Fc) as a signal quenching agent, with its electrochemical signal restored upon interaction with miRNA24-3p, a biomarker for acute pancreatitis. The platform features a composite luminescent material─tris(2,2′-bipyridine) dichlororuthenium(II)@goldnanoparticles@single-walled carbon nanotubes (Ru(bpy)32+@AuNPs@SWCNTs)─and employs persulfate as a coreactant. Under optimized conditions, this design demonstrated a wide dynamic range (10–15 M to 10–6 M) and an ultralow detection limit of approximately 60 aM for miRNA 24-3p. Additionally, it exhibited excellent specificity, reproducibility, and stability. These findings underscore the potential of this application of this ECL-based platform to revolutionize the clinical diagnosis of acute pancreatitis by enabling more timely and accurate interventions while paving the way for advancements in diagnostic technologies.
- 9 May 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (20) , 10765-10774
Electrochemiluminescence Sensor Based on DNA Octahedron and Nanoclusters for M6A Analysis
- 9 May 2025
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 8 (20) , 10765-10774
Electrochemiluminescence Sensor Based on DNA Octahedron and Nanoclusters for M6A Analysis
- 26 February 2025
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (3) , 1-15
A novel photoelectrochemical strategy for ultrasensitive and simultaneous detection of 5-methylcytosine and N6-methyladenosine based on proximity binding-triggered assembly MNAzyme -mediated HRCA
The preparation of UiO-66@CdTe@AuNPs composites is presented for the first time, which function as a photoelectrochemical (PEC) sensing matrix and are conjugated to a three-way junction (TWJ). We propose an antibody-based specific recognition-induced neighbor-joining reaction that initiates the assembly of two molecularly designed nucleic acid enzymes (MNAzymes), to release an oligonucleotide that hydrolyzes TWJ through the mechanism of a toehold-mediated strand displacement reaction (TSDR). Subsequently, a hybridization chain reaction application (HRCA)-based dendrimer is formed, which immobilizes a large number of quantum dots to generate a burst effect that reduces the photocurrent signal. As anticipated, the developed PEC biosensor showed excellent analytical performance for both m6A-RNA and m5C-RNA, with detection limits of 0.309 fM and 6.918 aM, respectively. The successful fabrication of this ultrasensitive and simultaneous PEC biosensor provides new insights for epigenetic research and the bioassay, mechanism investigation and clinical diagnosis of diseases associated with RNA methylation. Graphical Abstract
- 26 February 2025
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (3) , 1-15
A novel photoelectrochemical strategy for ultrasensitive and simultaneous detection of 5-methylcytosine and N6-methyladenosine based on proximity binding-triggered assembly MNAzyme -mediated HRCA
The preparation of UiO-66@CdTe@AuNPs composites is presented for the first time, which function as a photoelectrochemical (PEC) sensing matrix and are conjugated to a three-way junction (TWJ). We propose an antibody-based specific recognition-induced neighbor-joining reaction that initiates the assembly of two molecularly designed nucleic acid enzymes (MNAzymes), to release an oligonucleotide that hydrolyzes TWJ through the mechanism of a toehold-mediated strand displacement reaction (TSDR). Subsequently, a hybridization chain reaction application (HRCA)-based dendrimer is formed, which immobilizes a large number of quantum dots to generate a burst effect that reduces the photocurrent signal. As anticipated, the developed PEC biosensor showed excellent analytical performance for both m6A-RNA and m5C-RNA, with detection limits of 0.309 fM and 6.918 aM, respectively. The successful fabrication of this ultrasensitive and simultaneous PEC biosensor provides new insights for epigenetic research and the bioassay, mechanism investigation and clinical diagnosis of diseases associated with RNA methylation. Graphical Abstract
- 13 February 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1347, 343796
A strategy for electrochemical biosensing based on dendritic HCR amplification for detection of RNA m5C and m6A methylation
- 13 February 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1347, 343796
A strategy for electrochemical biosensing based on dendritic HCR amplification for detection of RNA m5C and m6A methylation
- Open Access
- 14 June 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (26) , 28228-28236
Highly Efficient Photoelectrochemical Detection of Cystatin C Based on a Core–Shell MOF Nanocomposite with Biomimetic-Catalysis Amplification
Cystatin C (CysC) has been proven to be used to diagnose acute kidney injury (AKI) rapidly and sensitively early. Therefore, it is urgent to develop a sensitive, novel, and rapid method for detecting CysC. In this work, a novel photoelectrochemical (PEC) biosensor was designed for ultrasensitive CysC detection. Ti-MOF@DM-LZU1@Au as a photosensitive material was first modified on the ITO electrode surface. Then, Ab1 and CysC were assembled on the electrode via the specific immunoresponse of an antigen and antibody. Lastly, the conjugate Ab2/l-Cys bilayer/l-Cys-hemin/G-quadruplex with self-catalytic enzyme performance, as a signal amplification approach, could further react with CysC and Ab1, which resulted in a stronger photocurrent. As expected, the constructed PEC sensor realized the ultrasensitive detection of CysC, with a detection range of 10 pg/mL to 16 μg/mL and a lower limit of 8.023 pg/mL. The biosensor had excellent repeatability, selectivity, and stability. Moreover, it can provide a new method for the sensitive and rapid detection of other protein molecules in clinical practice.
- 14 June 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (26) , 28228-28236
Open AccessHighly Efficient Photoelectrochemical Detection of Cystatin C Based on a Core–Shell MOF Nanocomposite with Biomimetic-Catalysis Amplification
Cystatin C (CysC) has been proven to be used to diagnose acute kidney injury (AKI) rapidly and sensitively early. Therefore, it is urgent to develop a sensitive, novel, and rapid method for detecting CysC. In this work, a novel photoelectrochemical (PEC) biosensor was designed for ultrasensitive CysC detection. Ti-MOF@DM-LZU1@Au as a photosensitive material was first modified on the ITO electrode surface. Then, Ab1 and CysC were assembled on the electrode via the specific immunoresponse of an antigen and antibody. Lastly, the conjugate Ab2/l-Cys bilayer/l-Cys-hemin/G-quadruplex with self-catalytic enzyme performance, as a signal amplification approach, could further react with CysC and Ab1, which resulted in a stronger photocurrent. As expected, the constructed PEC sensor realized the ultrasensitive detection of CysC, with a detection range of 10 pg/mL to 16 μg/mL and a lower limit of 8.023 pg/mL. The biosensor had excellent repeatability, selectivity, and stability. Moreover, it can provide a new method for the sensitive and rapid detection of other protein molecules in clinical practice.
- 29 February 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (3) , 1-11
Photoelectrochemical sensor based on AuNPs@WO3@TpPa-1-COF for quantification of DNA methylation levels
A “signal-off” photoelectrochemical (PEC) sensing platform has been designed for the ultrasensitive detection of DNA methylation levels and multiple methylated sites. The platform employs tungsten trioxide and TpPa-1-COF loaded by gold nanoparticle (AuNPs@WO3@TpPa-1-COF) composite material as the photoactive component and p-type reduced graphene (rGO) as an efficient quencher. The PEC signal of AuNPs@WO3@TpPa-1-COF composite is effectively quenched in the presence of p-type rGO, because p-type rGO can compete with AuNPs@WO3@TpPa-1-COF to deplete light energy and electron donors. In addition, a hybrid strand reaction (HCR) amplification strategy fixes more target DNA and then combines with rGO-modified anti-5-methylcytosine antibody to facilitate ultrasensitive DNA methylation detection. Under optimal conditions, DNA methylation can be measured within a linear concentration range of 10–14 to 10–8 M, with an exceptionally low detection limit of 0.19 fM (S/N = 3). At the same time, the platform can conduct quantitative determination of multi-site methylation, with the linear equation △I = 44.19LogA + 61.43, and the maximum number of methylation sites is 5. The sensor demonstrates high sensitivity, excellent selectivity, and satisfactory stability. Furthermore, the proposed signal-off PEC strategy was successfully employed to detect DNA methylation in spiked human serum samples, with recoveries ranging from 93.17 to 107.28% and relative standard deviation (RSD) ranging from 1.15 to 5.49%. Graphical Abstract
- 29 February 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (3) , 1-11
Photoelectrochemical sensor based on AuNPs@WO3@TpPa-1-COF for quantification of DNA methylation levels
A “signal-off” photoelectrochemical (PEC) sensing platform has been designed for the ultrasensitive detection of DNA methylation levels and multiple methylated sites. The platform employs tungsten trioxide and TpPa-1-COF loaded by gold nanoparticle (AuNPs@WO3@TpPa-1-COF) composite material as the photoactive component and p-type reduced graphene (rGO) as an efficient quencher. The PEC signal of AuNPs@WO3@TpPa-1-COF composite is effectively quenched in the presence of p-type rGO, because p-type rGO can compete with AuNPs@WO3@TpPa-1-COF to deplete light energy and electron donors. In addition, a hybrid strand reaction (HCR) amplification strategy fixes more target DNA and then combines with rGO-modified anti-5-methylcytosine antibody to facilitate ultrasensitive DNA methylation detection. Under optimal conditions, DNA methylation can be measured within a linear concentration range of 10–14 to 10–8 M, with an exceptionally low detection limit of 0.19 fM (S/N = 3). At the same time, the platform can conduct quantitative determination of multi-site methylation, with the linear equation △I = 44.19LogA + 61.43, and the maximum number of methylation sites is 5. The sensor demonstrates high sensitivity, excellent selectivity, and satisfactory stability. Furthermore, the proposed signal-off PEC strategy was successfully employed to detect DNA methylation in spiked human serum samples, with recoveries ranging from 93.17 to 107.28% and relative standard deviation (RSD) ranging from 1.15 to 5.49%. Graphical Abstract