Xu Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xu Yang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Bart J. van Wees
Zernike Institute for Advanced Materials, University of Groningen, NL-9747AG Groningen, The Netherlands
10 shared publicationsCaspar H. van der Wal
Zernike Institute for Advanced Materials University of Groningen NL-9747AG Groningen The Netherlands
4 shared publications- Caspar H. van der Wal
Zernike Institute for Advanced Materials, University of Groningen, NL-9747AG Groningen, The Netherlands
4 shared publications Tom Bosma
Zernike Institute for Advanced Materials University of Groningen NL-9747AG Groningen The Netherlands
1 shared publication- Tom Bosma
University Medical Centre Utrecht
1 shared publication
Latest Publications
- 15 October 2021
- Published by American Physical Society (APS) in Physical Review B
- Vol. 104 (15) , 155420
Linear-response magnetoresistance effects in chiral systems
The chirality-induced spin selectivity (CISS) effect enables the detection of chirality as electrical charge signals. It is often studied using a two-terminal circuit geometry where a ferromagnet is connected to a chiral component, and a change of electrical resistance is reported upon magnetization reversal. This is however not expected in the linear response regime because of compensating reciprocal processes, limiting the interpretation of experimental results. Here we show that magnetoresistance effects can indeed appear even in the linear response regime, either by changing the magnitude or the direction of the magnetization or an applied magnetic field. We illustrate this in a spin-valve device and in a chiral thin film as the CISS-induced Hanle magnetoresistance (CHMR) effect. This effect helps to distinguish spin-transport-related effects from other effects, and can thereby provide further insight into the origin of CISS.
- 15 October 2021
- Published by American Physical Society (APS) in Physical Review B
- Vol. 104 (15) , 155420
Linear-response magnetoresistance effects in chiral systems
The chirality-induced spin selectivity (CISS) effect enables the detection of chirality as electrical charge signals. It is often studied using a two-terminal circuit geometry where a ferromagnet is connected to a chiral component, and a change of electrical resistance is reported upon magnetization reversal. This is however not expected in the linear response regime because of compensating reciprocal processes, limiting the interpretation of experimental results. Here we show that magnetoresistance effects can indeed appear even in the linear response regime, either by changing the magnitude or the direction of the magnetization or an applied magnetic field. We illustrate this in a spin-valve device and in a chiral thin film as the CISS-induced Hanle magnetoresistance (CHMR) effect. This effect helps to distinguish spin-transport-related effects from other effects, and can thereby provide further insight into the origin of CISS.
- Open Access
Linear-response magnetoresistance effects in chiral systems
The chirality-induced spin selectivity (CISS) effect enables the detection of chirality as electrical charge signals. It is often studied using a two-terminal circuit geometry where a ferromagnet is connected to a chiral component, and a change of electrical resistance is reported upon magnetization reversal. This is however not expected in the linear response regime because of compensating reciprocal processes, limiting the interpretation of experimental results. Here we show that magnetoresistance effects can indeed appear even in the linear response regime, either by changing the magnitude or the direction of the magnetization or an applied magnetic field. We illustrate this in a spin-valve device and in a chiral thin film as the CISS-induced Hanle magnetoresistance (CHMR) effect. This effect helps to distinguish spin-transport-related effects from other effects, and can thereby provide further insight into the origin of CISS.
Open AccessLinear-response magnetoresistance effects in chiral systems
The chirality-induced spin selectivity (CISS) effect enables the detection of chirality as electrical charge signals. It is often studied using a two-terminal circuit geometry where a ferromagnet is connected to a chiral component, and a change of electrical resistance is reported upon magnetization reversal. This is however not expected in the linear response regime because of compensating reciprocal processes, limiting the interpretation of experimental results. Here we show that magnetoresistance effects can indeed appear even in the linear response regime, either by changing the magnitude or the direction of the magnetization or an applied magnetic field. We illustrate this in a spin-valve device and in a chiral thin film as the CISS-induced Hanle magnetoresistance (CHMR) effect. This effect helps to distinguish spin-transport-related effects from other effects, and can thereby provide further insight into the origin of CISS.
- 27 August 2020
- Published by University of Groningen Press
Connecting chirality and spin in electronic devices
- 27 August 2020
- Published by University of Groningen Press
Connecting chirality and spin in electronic devices
- Open Access
- 16 July 2020
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 20 (8) , 6148-6154
Detecting Chirality in Two-Terminal Electronic Nanodevices
Central to spintronics is the interconversion between electronic charge and spin currents, and this can arise from the chirality-induced spin selectivity (CISS) effect. CISS is often studied as magnetoresistance (MR) in two-terminal (2T) electronic nanodevices containing a chiral (molecular) component and a ferromagnet. However, fundamental understanding of when and how this MR can occur is lacking. Here, we uncover an elementary mechanism that generates such a MR for nonlinear response. It requires energy-dependent transport and energy relaxation within the device. The sign of the MR depends on chirality, charge carrier type, and bias direction. Additionally, we reveal how CISS can be detected in the linear response regime in magnet-free 2T nanodevices, either by forming a chirality-based spin-valve using two or more chiral components, or by Hanle spin precession in devices with a single chiral component. Our results provide operation principles and design guidelines for chirality-based spintronic nanodevices and technologies.
- 16 July 2020
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 20 (8) , 6148-6154
Open AccessDetecting Chirality in Two-Terminal Electronic Nanodevices
Central to spintronics is the interconversion between electronic charge and spin currents, and this can arise from the chirality-induced spin selectivity (CISS) effect. CISS is often studied as magnetoresistance (MR) in two-terminal (2T) electronic nanodevices containing a chiral (molecular) component and a ferromagnet. However, fundamental understanding of when and how this MR can occur is lacking. Here, we uncover an elementary mechanism that generates such a MR for nonlinear response. It requires energy-dependent transport and energy relaxation within the device. The sign of the MR depends on chirality, charge carrier type, and bias direction. Additionally, we reveal how CISS can be detected in the linear response regime in magnet-free 2T nanodevices, either by forming a chirality-based spin-valve using two or more chiral components, or by Hanle spin precession in devices with a single chiral component. Our results provide operation principles and design guidelines for chirality-based spintronic nanodevices and technologies.
- Open Access
Detecting chirality in two-terminal electronic devices
Central to spintronics is the interconversion between electronic charge and spin currents, and this can arise from the chirality-induced spin selectivity (CISS) effect. CISS is often studied as magnetoresistance (MR) in two-terminal (2T) electronic devices containing a chiral (molecular) component and a ferromagnet. However, fundamental understanding of when and how this MR can occur is lacking. Here, we uncover an elementary mechanism that generates such a MR for nonlinear response. It requires energy-dependent transport and energy relaxation within the device. The sign of the MR depends on chirality, charge carrier type, and bias direction. Additionally, we reveal how CISS can be detected in the linear response regime in magnet-free 2T devices, either by forming a chirality-based spin-valve using two or more chiral components, or by Hanle spin precession in devices with a single chiral component. Our results provide operation principles and design guidelines for chirality-based spintronic devices and technologies.
Open AccessDetecting chirality in two-terminal electronic devices
Central to spintronics is the interconversion between electronic charge and spin currents, and this can arise from the chirality-induced spin selectivity (CISS) effect. CISS is often studied as magnetoresistance (MR) in two-terminal (2T) electronic devices containing a chiral (molecular) component and a ferromagnet. However, fundamental understanding of when and how this MR can occur is lacking. Here, we uncover an elementary mechanism that generates such a MR for nonlinear response. It requires energy-dependent transport and energy relaxation within the device. The sign of the MR depends on chirality, charge carrier type, and bias direction. Additionally, we reveal how CISS can be detected in the linear response regime in magnet-free 2T devices, either by forming a chirality-based spin-valve using two or more chiral components, or by Hanle spin precession in devices with a single chiral component. Our results provide operation principles and design guidelines for chirality-based spintronic devices and technologies.
- Open Access
Reply to "Comment on 'Spin-dependent electron transmission model for chiral molecules in mesoscopic devices'"
Here we emphasize once more the distinction between generating CISS (spin-charge current conversion) in a chiral system and detecting it as magnetoresistance in two-terminal electronic devices. We also highlight important differences between electrical measurement results obtained in the linear response regime and those obtained in the nonlinear regime.
Open AccessReply to "Comment on 'Spin-dependent electron transmission model for chiral molecules in mesoscopic devices'"
Here we emphasize once more the distinction between generating CISS (spin-charge current conversion) in a chiral system and detecting it as magnetoresistance in two-terminal electronic devices. We also highlight important differences between electrical measurement results obtained in the linear response regime and those obtained in the nonlinear regime.
- 17 January 2020
- Published by American Physical Society (APS) in Physical Review B
- Vol. 101 (2) , 026404
Reply to “Comment on ‘Spin-dependent electron transmission model for chiral molecules in mesoscopic devices’”
In this Reply, we emphasize once more the distinction between generating CISS (spin-charge current conversion) in a chiral spin-orbit system and detecting it as magnetoresistance in two-terminal electronic devices. We also highlight important differences between electrical measurement results obtained in the linear response regime and those obtained in the nonlinear regime.
- 17 January 2020
- Published by American Physical Society (APS) in Physical Review B
- Vol. 101 (2) , 026404
Reply to “Comment on ‘Spin-dependent electron transmission model for chiral molecules in mesoscopic devices’”
In this Reply, we emphasize once more the distinction between generating CISS (spin-charge current conversion) in a chiral spin-orbit system and detecting it as magnetoresistance in two-terminal electronic devices. We also highlight important differences between electrical measurement results obtained in the linear response regime and those obtained in the nonlinear regime.
- 20 June 2019
- Published by American Physical Society (APS) in Physical Review B
- Vol. 99 (21) , 214428
Circuit-model analysis for spintronic devices with chiral molecules as spin injectors
Recent research discovered that charge-transfer processes in chiral molecules can be spin-selective, and the effect was named chiral-induced spin selectivity (CISS). Follow-up work studied hybrid spintronic devices with conventional electronic materials and chiral (bio)molecules. However, a theoretical foundation for the CISS effect is still in development, and the spintronic signals were not evaluated quantitatively. We present a circuit-model approach that can provide quantitative evaluations. Our analysis assumes the scheme of a recent experiment that used photosystem I (PSI) as spin injectors, for which we find that the experimentally observed signals are, under any reasonable assumptions on relevant PSI timescales, too high to be fully due to the CISS effect. We also show that the CISS effect can in principle be detected using the same type of solid-state device, and by replacing silver with graphene, the signals due to spin generation can be enlarged four orders of magnitude. Our approach thus provides a generic framework for analyzing these types of experiments and advancing the understanding of the CISS effect.
- 20 June 2019
- Published by American Physical Society (APS) in Physical Review B
- Vol. 99 (21) , 214428
Circuit-model analysis for spintronic devices with chiral molecules as spin injectors
Recent research discovered that charge-transfer processes in chiral molecules can be spin-selective, and the effect was named chiral-induced spin selectivity (CISS). Follow-up work studied hybrid spintronic devices with conventional electronic materials and chiral (bio)molecules. However, a theoretical foundation for the CISS effect is still in development, and the spintronic signals were not evaluated quantitatively. We present a circuit-model approach that can provide quantitative evaluations. Our analysis assumes the scheme of a recent experiment that used photosystem I (PSI) as spin injectors, for which we find that the experimentally observed signals are, under any reasonable assumptions on relevant PSI timescales, too high to be fully due to the CISS effect. We also show that the CISS effect can in principle be detected using the same type of solid-state device, and by replacing silver with graphene, the signals due to spin generation can be enlarged four orders of magnitude. Our approach thus provides a generic framework for analyzing these types of experiments and advancing the understanding of the CISS effect.
- Open Access
Circuit-Model Analysis for Spintronic Devices with Chiral Molecules as Spin Injectors
Recent research discovered that charge transfer processes in chiral molecules can be spin selective and named the effect chiral-induced spin selectivity (CISS). Follow-up work studied hybrid spintronic devices with conventional electronic materials and chiral (bio)molecules. However, a theoretical foundation for the CISS effect is still in development and the spintronic signals were not evaluated quantitatively. We present a circuit-model approach that can provide quantitative evaluations. Our analysis assumes the scheme of a recent experiment that used photosystem~I (PSI) as spin injectors, for which we find that the experimentally observed signals are, under any reasonable assumptions on relevant PSI time scales, too high to be fully due to the CISS effect. We also show that the CISS effect can in principle be detected using the same type of solid-state device, and by replacing silver with graphene, the signals due to spin generation can be enlarged four orders of magnitude. Our approach thus provides a generic framework for analyzing this type of experiments and advancing the understanding of the CISS effect.
Open AccessCircuit-Model Analysis for Spintronic Devices with Chiral Molecules as Spin Injectors
Recent research discovered that charge transfer processes in chiral molecules can be spin selective and named the effect chiral-induced spin selectivity (CISS). Follow-up work studied hybrid spintronic devices with conventional electronic materials and chiral (bio)molecules. However, a theoretical foundation for the CISS effect is still in development and the spintronic signals were not evaluated quantitatively. We present a circuit-model approach that can provide quantitative evaluations. Our analysis assumes the scheme of a recent experiment that used photosystem~I (PSI) as spin injectors, for which we find that the experimentally observed signals are, under any reasonable assumptions on relevant PSI time scales, too high to be fully due to the CISS effect. We also show that the CISS effect can in principle be detected using the same type of solid-state device, and by replacing silver with graphene, the signals due to spin generation can be enlarged four orders of magnitude. Our approach thus provides a generic framework for analyzing this type of experiments and advancing the understanding of the CISS effect.
- Open Access
Spin-Dependent Electron Transmission Model for Chiral Molecules in Mesoscopic Devices
Various device-based experiments have indicated that electron transfer in certain chiral molecules may be spin-dependent, a phenomenon known as the Chiral Induced Spin Selectivity (CISS) effect. However, due to the complexity of these devices and a lack of theoretical understanding, it is not always clear to what extent the chiral character of the molecules actually contributes to the magnetic-field-dependent signals in these experiments. To address this issue, we report here an electron transmission model that evaluates the role of the CISS effect in two-terminal and multi-terminal linear-regime electron transport experiments. Our model reveals that for the CISS effect, the chirality-dependent spin transmission is accompanied by a spin-flip electron reflection process. Furthermore, we show that more than two terminals are required in order to probe the CISS effect in the linear regime. In addition, we propose two types of multi-terminal nonlocal transport measurements that can distinguish the CISS effect from other magnetic-field-dependent signals. Our model provides an effective tool to review and design CISS-related transport experiments, and to enlighten the mechanism of the CISS effect itself.
Open AccessSpin-Dependent Electron Transmission Model for Chiral Molecules in Mesoscopic Devices
Various device-based experiments have indicated that electron transfer in certain chiral molecules may be spin-dependent, a phenomenon known as the Chiral Induced Spin Selectivity (CISS) effect. However, due to the complexity of these devices and a lack of theoretical understanding, it is not always clear to what extent the chiral character of the molecules actually contributes to the magnetic-field-dependent signals in these experiments. To address this issue, we report here an electron transmission model that evaluates the role of the CISS effect in two-terminal and multi-terminal linear-regime electron transport experiments. Our model reveals that for the CISS effect, the chirality-dependent spin transmission is accompanied by a spin-flip electron reflection process. Furthermore, we show that more than two terminals are required in order to probe the CISS effect in the linear regime. In addition, we propose two types of multi-terminal nonlocal transport measurements that can distinguish the CISS effect from other magnetic-field-dependent signals. Our model provides an effective tool to review and design CISS-related transport experiments, and to enlighten the mechanism of the CISS effect itself.