Alessandro Coppolecchia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alessandro Coppolecchia has a total of 405 co-authors. Here are the top co-authors by number of shared publications:
- Fabio Columbro
Sapienza University of Rome
12 shared publications - Francesco Piacentini
Dipartimento di Fisica, Sapienza Universit di Roma, Roma, Italy
12 shared publications - Alessandro Paiella
Sapienza University of Rome
11 shared publications - Pierluigi De Bernardis
Sapienza University of Rome
11 shared publications - Silvia Masi
Sapienza University of Rome
9 shared publications - Elia Stefano Battistelli
Sapienza University of Rome
8 shared publications
Latest Publications
- Open Access
- 2 June 2026
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 1004 (1)
Intracluster Medium Fluctuations on Scales up to 1 Mpc: A Combined eROSITA and SPT/Planck Analysis of A3266
Galaxy clusters form through hierarchical assembly, where smaller substructures merge to build the largest gravitationally bound objects in the Universe. These mergers, combined with feedback from active galactic nucleus (AGN), filamentary accretion, and other energy injection processes, generate turbulence and perturbations within the intracluster medium (ICM). X-ray and Sunyaev–Zel’dovich (SZ) observations can be utilized to measure these ICM density and pressure inhomogeneities, in turn providing constraints on the effective equation of state of the perturbations and ICM velocities. In this work, we analyze deep SRG-eROSITA (hereafter eROSITA) and Planck/South Pole Telescope (SPT) observations of A3266, a dynamically complex merging cluster with elongated morphology and significant substructure. We measure pressure and density fluctuations, and compute the power spectra and deprojected 3D amplitudes of these perturbations. We estimate the ratio of pressure-to-density fluctuation amplitudes as 1.07 ± 0.55 and nonthermal pressure support 0.067 ± 0.049. Density fluctuations are found to be stronger in the northern sector of the cluster compared to the south, consistent with ongoing accretion along a filamentary structure revealed by eROSITA. Further, we find the amplitude of density fluctuations increases with radius, qualitatively consistent with the trend found in cosmological simulations. Uncertainties in our results are dominated by the relatively low sensitivity of current Planck/SPT data, suggesting that improvements in SZ data quality could substantially improve our understanding of ICM energy injection, transport, and dissipation from this technique.
- 2 June 2026
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 1004 (1)
Open AccessIntracluster Medium Fluctuations on Scales up to 1 Mpc: A Combined eROSITA and SPT/Planck Analysis of A3266
Galaxy clusters form through hierarchical assembly, where smaller substructures merge to build the largest gravitationally bound objects in the Universe. These mergers, combined with feedback from active galactic nucleus (AGN), filamentary accretion, and other energy injection processes, generate turbulence and perturbations within the intracluster medium (ICM). X-ray and Sunyaev–Zel’dovich (SZ) observations can be utilized to measure these ICM density and pressure inhomogeneities, in turn providing constraints on the effective equation of state of the perturbations and ICM velocities. In this work, we analyze deep SRG-eROSITA (hereafter eROSITA) and Planck/South Pole Telescope (SPT) observations of A3266, a dynamically complex merging cluster with elongated morphology and significant substructure. We measure pressure and density fluctuations, and compute the power spectra and deprojected 3D amplitudes of these perturbations. We estimate the ratio of pressure-to-density fluctuation amplitudes as 1.07 ± 0.55 and nonthermal pressure support 0.067 ± 0.049. Density fluctuations are found to be stronger in the northern sector of the cluster compared to the south, consistent with ongoing accretion along a filamentary structure revealed by eROSITA. Further, we find the amplitude of density fluctuations increases with radius, qualitatively consistent with the trend found in cosmological simulations. Uncertainties in our results are dominated by the relatively low sensitivity of current Planck/SPT data, suggesting that improvements in SZ data quality could substantially improve our understanding of ICM energy injection, transport, and dissipation from this technique.
- Open Access
- 1 February 2026
- Published by IOP Publishing in Journal of Cosmology and Astroparticle Physics
- Vol. 2026 (02)
Systematic effect induced by misalignment in a reflective polarization modulator for CMB, and application to the LiteBIRD case
The LiteBIRD mission aims to measure the Cosmic Microwave Background (CMB) polarization with unprecedented precision to detect primordial B modes and constrain the tensor-to-scalar ratio r . A key component of LiteBIRD are the polarization modulators, based on Half-Wave Plates (HWP). In this work, we study the systematic effects caused by a constant misalignment between the HWP's rotation axis and optical axis, in case of a reflective HWP, when the misalignment is small and thus not corrected for in the pointing reconstruction. While the HWP shape is assumed to be ideal (i.e., plane-parallel), this misalignment mimics the effect of a physical wedge. Throughout the paper, we refer to this as a wedge-like effect. This analysis also applies to the case of transmissive HWP with non-parallel surfaces, and is quantified by a wedge angle. This misalignment leads to HWP-synchronous pointing error. Using the LiteBIRD simulation framework, we implement the wedge-like effect in time-ordered data (TOD) and analyze its impact on reconstructed maps and angular power spectra. We find that the wedge systematically bias polarization measurements, leading to spurious B modes. By evaluating the total error induced by the wedge-like effect Δ r wedge on the tensor-to-scalar ratio, we establish a constraint on the maximum allowable wedge angle ( α max ) to ensure systematic errors remain below mission requirements. Our analysis, based on CMB-only simulations with orthogonal detector pairs (ranging from two to six detectors in total), assuming perfectly matching detectors within each pair and neglecting noise and foregrounds, provides a constraint of α max = 22.7 arcmin from the point of view of spurious polarization. Beam reconstruction and pointing systematics are anyway dominant for values of α larger than 4 arcmin. Interestingly we find that the contamination mimics lensing B modes, and not primordial tensor modes and that it is reduced increasing the number of detectors. This study highlights the importance of precise optical alignment in future CMB polarization experiments. Throughout this work, we assume a constant wedge angle. However, the potential wobbling of the reflective HWP introduces a time-dependent variation of the wedge angle, which may have a non-negligible impact on the results of this paper. Future studies will address this effect by investigating the time-dependent variations in the wedge angle and their impact on the overall systematics, as well as exploring more realistic scenarios where detectors within each pair are not perfectly balanced.
- 1 February 2026
- Published by IOP Publishing in Journal of Cosmology and Astroparticle Physics
- Vol. 2026 (02)
Open AccessSystematic effect induced by misalignment in a reflective polarization modulator for CMB, and application to the LiteBIRD case
The LiteBIRD mission aims to measure the Cosmic Microwave Background (CMB) polarization with unprecedented precision to detect primordial B modes and constrain the tensor-to-scalar ratio r . A key component of LiteBIRD are the polarization modulators, based on Half-Wave Plates (HWP). In this work, we study the systematic effects caused by a constant misalignment between the HWP's rotation axis and optical axis, in case of a reflective HWP, when the misalignment is small and thus not corrected for in the pointing reconstruction. While the HWP shape is assumed to be ideal (i.e., plane-parallel), this misalignment mimics the effect of a physical wedge. Throughout the paper, we refer to this as a wedge-like effect. This analysis also applies to the case of transmissive HWP with non-parallel surfaces, and is quantified by a wedge angle. This misalignment leads to HWP-synchronous pointing error. Using the LiteBIRD simulation framework, we implement the wedge-like effect in time-ordered data (TOD) and analyze its impact on reconstructed maps and angular power spectra. We find that the wedge systematically bias polarization measurements, leading to spurious B modes. By evaluating the total error induced by the wedge-like effect Δ r wedge on the tensor-to-scalar ratio, we establish a constraint on the maximum allowable wedge angle ( α max ) to ensure systematic errors remain below mission requirements. Our analysis, based on CMB-only simulations with orthogonal detector pairs (ranging from two to six detectors in total), assuming perfectly matching detectors within each pair and neglecting noise and foregrounds, provides a constraint of α max = 22.7 arcmin from the point of view of spurious polarization. Beam reconstruction and pointing systematics are anyway dominant for values of α larger than 4 arcmin. Interestingly we find that the contamination mimics lensing B modes, and not primordial tensor modes and that it is reduced increasing the number of detectors. This study highlights the importance of precise optical alignment in future CMB polarization experiments. Throughout this work, we assume a constant wedge angle. However, the potential wobbling of the reflective HWP introduces a time-dependent variation of the wedge angle, which may have a non-negligible impact on the results of this paper. Future studies will address this effect by investigating the time-dependent variations in the wedge angle and their impact on the overall systematics, as well as exploring more realistic scenarios where detectors within each pair are not perfectly balanced.
- Open Access
- 6 March 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1075
The kinetic inductance detectors for the MISTRAL instrument: Installation and characterization at the Sardinia Radio Telescope
- 6 March 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1075
Open AccessThe kinetic inductance detectors for the MISTRAL instrument: Installation and characterization at the Sardinia Radio Telescope
- Open Access
- 13 February 2025
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 218 (5) , 335-346
The Cryogenic System of the MISTRAL Instrument: Design and In-lab Performance
We describe the design and performance of the cryostat and the multi-stage sub-K single-shot sorption cooler for the MIllimeter Sardinia Radio Telescope Receiver based on Array of Lumped elements kids (MISTRAL) experiment. MISTRAL is a W-band (77 - 103 GHz) Ti/Al bi-layer Lumped Elements Kinetic Inductance Detectors (LEKIDs) camera working at the Gregorian focus of the 64 m aperture Sardinia Radio Telescope (SRT), located in Sardinia (Italy). The cryogenic system, based on a 1.5 W at 4.2 K Pulse Tube (PT) cryocooler, provides the 4 K base temperature for the sub-K refrigerator, and cools down the cold optics and the filters chain of the instrument. The sub-K sorption cooler consists of two intermediate stages, $$^{4}$$ He and $$^{3}$$ He sorption refrigerators that allow to reduce the heat load on the ultra-cold head, and a twin stage of $$^{3}$$ He sorption refrigerator providing the 0.2 K operation temperature for the 415-pixel array of LEKIDs. MISTRAL experiment was installed at SRT in May 2023, the technical commissioning started in June 2023. We will show the performance of the system in the laboratory.- 13 February 2025
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 218 (5) , 335-346
Open AccessThe Cryogenic System of the MISTRAL Instrument: Design and In-lab Performance
We describe the design and performance of the cryostat and the multi-stage sub-K single-shot sorption cooler for the MIllimeter Sardinia Radio Telescope Receiver based on Array of Lumped elements kids (MISTRAL) experiment. MISTRAL is a W-band (77 - 103 GHz) Ti/Al bi-layer Lumped Elements Kinetic Inductance Detectors (LEKIDs) camera working at the Gregorian focus of the 64 m aperture Sardinia Radio Telescope (SRT), located in Sardinia (Italy). The cryogenic system, based on a 1.5 W at 4.2 K Pulse Tube (PT) cryocooler, provides the 4 K base temperature for the sub-K refrigerator, and cools down the cold optics and the filters chain of the instrument. The sub-K sorption cooler consists of two intermediate stages, $$^{4}$$ He and $$^{3}$$ He sorption refrigerators that allow to reduce the heat load on the ultra-cold head, and a twin stage of $$^{3}$$ He sorption refrigerator providing the 0.2 K operation temperature for the 415-pixel array of LEKIDs. MISTRAL experiment was installed at SRT in May 2023, the technical commissioning started in June 2023. We will show the performance of the system in the laboratory. - Open Access
- 6 September 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
A 350 GHz array of LEKIDs for balloon-borne CMB observations
- 6 September 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
Open AccessA 350 GHz array of LEKIDs for balloon-borne CMB observations
- 21 January 2023
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 211 (5-6) , 415-425
Pulse Tube Cooler with > 100 m Flexible Lines for Operation of Cryogenic Detector Arrays at Large Radiotelescopes
- 21 January 2023
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 211 (5-6) , 415-425
Pulse Tube Cooler with > 100 m Flexible Lines for Operation of Cryogenic Detector Arrays at Large Radiotelescopes
- Open Access
- 28 October 2021
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 921 (1) , 34
The Crab Nebula as a Calibrator for Wide-beam Cosmic Microwave Background Polarization Surveys
We analyze the effect of polarized diffuse emission in the calibration of wide-beam millimeter-wave polarimeters, when using the Crab Nebula as a reference source for both polarized brightness and polarization angle. We show that, for CMB polarization experiments aiming at detecting B-mode in a scenario with a tensor to scalar ratio r ∼ 0.001, wide (a few degrees in diameter), precise ( σ Q , σ U ∼ 20 μ K CMB arcmin ), high angular resolution (<FWHM) reference maps are needed to properly take into account the effects of diffuse polarized emission and avoid significant bias in the calibration.
- 28 October 2021
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 921 (1) , 34
Open AccessThe Crab Nebula as a Calibrator for Wide-beam Cosmic Microwave Background Polarization Surveys
We analyze the effect of polarized diffuse emission in the calibration of wide-beam millimeter-wave polarimeters, when using the Crab Nebula as a reference source for both polarized brightness and polarization angle. We show that, for CMB polarization experiments aiming at detecting B-mode in a scenario with a tensor to scalar ratio r ∼ 0.001, wide (a few degrees in diameter), precise ( σ Q , σ U ∼ 20 μ K CMB arcmin ), high angular resolution (<FWHM) reference maps are needed to properly take into account the effects of diffuse polarized emission and avoid significant bias in the calibration.
- 22 July 2020
- Published by Elsevier in Cryogenics
- Vol. 110, 103129
The long duration cryogenic system of the OLIMPO balloon–borne experiment: Design and in–flight performance
- 22 July 2020
- Published by Elsevier in Cryogenics
- Vol. 110, 103129
The long duration cryogenic system of the OLIMPO balloon–borne experiment: Design and in–flight performance
- 9 December 2019
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 130-137
W-band Lumped Element Kinetic Inductance Detector Array for Large Ground-Based Telescopes
- 9 December 2019
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 130-137
W-band Lumped Element Kinetic Inductance Detector Array for Large Ground-Based Telescopes
- 1 February 2019
- Published by IOP Publishing in Journal of Cosmology and Astroparticle Physics
- Vol. 2019 (02) , E01
Erratum: Kinetic inductance detectors for the OLIMPO experiment: design and pre-flight characterization
Please see the PDF file for details.
- 1 February 2019
- Published by IOP Publishing in Journal of Cosmology and Astroparticle Physics
- Vol. 2019 (02) , E01
Erratum: Kinetic inductance detectors for the OLIMPO experiment: design and pre-flight characterization
Please see the PDF file for details.