Keiichi Tanabe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Keiichi Tanabe has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
- Tsunehiro Hato
Superconducting Sensing Technology Research Association, Yokohama, Japan
17 shared publications - Seiji Adachi
Superconducting technology research association, Yokohama, Kanagawa Japan 223-0051
12 shared publications - Akira Tsukamoto
Superconducting sensing technology research association, Japan
7 shared publications - Yasuo Oshikubo
Superconducting Sensing Technology Research Association
6 shared publications - Seiji Adachi
International Superconductivity Technology Center, 1-10-13, Shinonome Koto-ku, Tokyo 135-0062, Japan
5 shared publications - Michitaka Maruyama
National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan
4 shared publications
Latest Publications
- 23 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (3) , 1-9
Design and Fabrication of HTS-SQUID Gradiometer With Imbalance of 10–4 Using a Gradiometric SQUID Structure
We have succeeded in fabricating a high-temperature superconducting (HTS) thin-film gradiometer with small imbalance by applying an HTS multilayer process, including crossovers, superconductive contacts, and ramp-edge Josephson junctions. The gradiometer consists of a series pickup coil and a gradiometric superconducting quantum interference device (SQUID) structure. Since the intrinsic imbalance of the series pickup coil is found to be small, a highly balanced gradiometer can be obtained by selecting the gradiometric SQUID inductor with imbalance that cancels the imbalance of the pickup coil out. The fabricated gradiometer showed the imbalance better than 10 –4 by applying a homogeneous magnetic field using a large circular coil in an outdoor experiment.
- 23 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (3) , 1-9
Design and Fabrication of HTS-SQUID Gradiometer With Imbalance of 10–4 Using a Gradiometric SQUID Structure
We have succeeded in fabricating a high-temperature superconducting (HTS) thin-film gradiometer with small imbalance by applying an HTS multilayer process, including crossovers, superconductive contacts, and ramp-edge Josephson junctions. The gradiometer consists of a series pickup coil and a gradiometric superconducting quantum interference device (SQUID) structure. Since the intrinsic imbalance of the series pickup coil is found to be small, a highly balanced gradiometer can be obtained by selecting the gradiometric SQUID inductor with imbalance that cancels the imbalance of the pickup coil out. The fabricated gradiometer showed the imbalance better than 10 –4 by applying a homogeneous magnetic field using a large circular coil in an outdoor experiment.
- Open Access
- 20 March 2021
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 56 (2) , 94-95
Superconducting Sensing Technology Corporation (SUSTEC)
- 20 March 2021
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 56 (2) , 94-95
Open AccessSuperconducting Sensing Technology Corporation (SUSTEC)
- 12 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Development of Three-Channel HTS-SQUID Inspection System for Orthotropic Steel Decks of Expressway Bridges
We have developed a three-channel HTS-SQUID eddy current testing (ECT) system for detection of a fatigue crack which occurs in a steel deck plate used in expressway bridges. To avoid physical interference between adjacent channels, a dipole coil with compact design is employed. A field test using the three channel ECT system was performed on an expressway bridge having an orthotropic steel deck structure under traffic lane restrictions. Although a signal corresponding to existence of a fatigue crack was not detected due to a low occurrence rate of fatigue crack, we could demonstrate a stable and long-time operation in an urban area during the daytime and acquisition of correct data corresponding to some structural features of the expressway bridge.
- 12 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Development of Three-Channel HTS-SQUID Inspection System for Orthotropic Steel Decks of Expressway Bridges
We have developed a three-channel HTS-SQUID eddy current testing (ECT) system for detection of a fatigue crack which occurs in a steel deck plate used in expressway bridges. To avoid physical interference between adjacent channels, a dipole coil with compact design is employed. A field test using the three channel ECT system was performed on an expressway bridge having an orthotropic steel deck structure under traffic lane restrictions. Although a signal corresponding to existence of a fatigue crack was not detected due to a low occurrence rate of fatigue crack, we could demonstrate a stable and long-time operation in an urban area during the daytime and acquisition of correct data corresponding to some structural features of the expressway bridge.
- 12 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
All-Round Inspection of a Pipe Based on Ultrasonic Guided Wave Testing Utilizing Magnetostrictive Method and HTS-SQUID Gradiometer
We developed an ultrasonic guided wave testing system for pipes utilizing magnetostrictive method and hightemperature superconductor (HTS) superconducting quantum interference device (SQUID) gradiometer. Two pre-magnetized nickel thin plates were adhered on an aluminium pipe. One of them with a field coil was used as a magnetostriction-based T (0, 1) mode guided wave transmitter, while the other was used as a receiver. Allround inspections of the pipe without and with a circumference slit were conducted by measuring the T (0,1) mode guide waves around circumference of the pipe using the HTS-SQUID-based guided wave testing system. The optimum experimental setup about excitation frequency and input current to the transmitter was investigated using ez-SQUID electronics. By applying a sine burst current of 0.2 A at 50 kHz with single cycle to the transmitter and rotating the pipe stepwise at 30°, “B-scan” images of the guided wave propagating on the pipe without and with slit were measured. An axisymmetric distribution of a reflected wave from the slit was well detected. We analyzed distribution of incident waves and reflected waves from the end of the pipe based on magnetization in the nickel plates using an electromagnetic simulator and proposed a new transducer.
- 12 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
All-Round Inspection of a Pipe Based on Ultrasonic Guided Wave Testing Utilizing Magnetostrictive Method and HTS-SQUID Gradiometer
We developed an ultrasonic guided wave testing system for pipes utilizing magnetostrictive method and hightemperature superconductor (HTS) superconducting quantum interference device (SQUID) gradiometer. Two pre-magnetized nickel thin plates were adhered on an aluminium pipe. One of them with a field coil was used as a magnetostriction-based T (0, 1) mode guided wave transmitter, while the other was used as a receiver. Allround inspections of the pipe without and with a circumference slit were conducted by measuring the T (0,1) mode guide waves around circumference of the pipe using the HTS-SQUID-based guided wave testing system. The optimum experimental setup about excitation frequency and input current to the transmitter was investigated using ez-SQUID electronics. By applying a sine burst current of 0.2 A at 50 kHz with single cycle to the transmitter and rotating the pipe stepwise at 30°, “B-scan” images of the guided wave propagating on the pipe without and with slit were measured. An axisymmetric distribution of a reflected wave from the slit was well detected. We analyzed distribution of incident waves and reflected waves from the end of the pipe based on magnetization in the nickel plates using an electromagnetic simulator and proposed a new transducer.
- 12 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Development of a Highly Sensitive Magnetic Field Detector With a Wide Frequency Range for Nondestructive Testing Using an HTS Coil With Magnetic Sensors
To perform an early stage detection of the deteriora-tion of steel parts used in infrastructures, a nondestructive testing method is required, which is capable of evaluating hidden parts, such as a steel deck covered with an asphalt pavement. To achieve this, a magnetic field detector should be sufficiently large to detect magnetic fields over a wide range to account for high lift-off. In ad-dition, the detector must be capable of functioning at high frequen-cies for a high-speed inspection of surface cracks, and at low fre-quencies to compensate for the skin effect during the inspection of inner or rear side cracks. In this study, we developed a magnetic field detector for eddy current testing in a wide frequency range by combining a high-temperature superconducting (HTS) coil made using DI-BSCCO tapes with a tunnel magnetoresistive (TMR) sen-sor. The TMR sensor was attached on the inside of the loop of the HTS coil to maximize the shielding characteristic. We applied the developed system to nondestructive testing, which can detect a signal from an artificial crack with a lift-off of 75 mm, which is greater than the thickness of the asphalt pavement. In addition, inner cracks that are 2.7 mm beneath the surface can be detected with a 10 Hz applied magnetic field.
- 12 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Development of a Highly Sensitive Magnetic Field Detector With a Wide Frequency Range for Nondestructive Testing Using an HTS Coil With Magnetic Sensors
To perform an early stage detection of the deteriora-tion of steel parts used in infrastructures, a nondestructive testing method is required, which is capable of evaluating hidden parts, such as a steel deck covered with an asphalt pavement. To achieve this, a magnetic field detector should be sufficiently large to detect magnetic fields over a wide range to account for high lift-off. In ad-dition, the detector must be capable of functioning at high frequen-cies for a high-speed inspection of surface cracks, and at low fre-quencies to compensate for the skin effect during the inspection of inner or rear side cracks. In this study, we developed a magnetic field detector for eddy current testing in a wide frequency range by combining a high-temperature superconducting (HTS) coil made using DI-BSCCO tapes with a tunnel magnetoresistive (TMR) sen-sor. The TMR sensor was attached on the inside of the loop of the HTS coil to maximize the shielding characteristic. We applied the developed system to nondestructive testing, which can detect a signal from an artificial crack with a lift-off of 75 mm, which is greater than the thickness of the asphalt pavement. In addition, inner cracks that are 2.7 mm beneath the surface can be detected with a 10 Hz applied magnetic field.
- 4 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
T1-Weighted Image by Ultra-Low Field SQUID-MRI
We are developing an Ultra-Low Field (ULF) Magnetic Resonance Imaging (MRI) system with a high-temperature superconductor superconducting quantum interference device (HTS-SQUID) for the purpose of food contaminant inspection. Our previous ULF SQUID-MRI system for food inspection used a resonant circuit to detect a magnetic field, which was tuned at the Larmor frequency. However, when the MR signal frequency decreases, the signal bandwidth becomes narrower. Since the line width of the NMR spectrum of food with a short relaxation time becomes broad, it is difficult to measure the MR signal. Therefore, to address this issue, we employed a non- resonant method to widen the bandwidth. In this paper, we describe a ULF SQUID-MRI system using a non-resonant Cu wound flux transformer to image food with a shorter relaxation time. As a result, $\rm T_1$ - weighted images of samples containing water and oil could be acquired by varying the polarizing time.- 4 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
T1-Weighted Image by Ultra-Low Field SQUID-MRI
We are developing an Ultra-Low Field (ULF) Magnetic Resonance Imaging (MRI) system with a high-temperature superconductor superconducting quantum interference device (HTS-SQUID) for the purpose of food contaminant inspection. Our previous ULF SQUID-MRI system for food inspection used a resonant circuit to detect a magnetic field, which was tuned at the Larmor frequency. However, when the MR signal frequency decreases, the signal bandwidth becomes narrower. Since the line width of the NMR spectrum of food with a short relaxation time becomes broad, it is difficult to measure the MR signal. Therefore, to address this issue, we employed a non- resonant method to widen the bandwidth. In this paper, we describe a ULF SQUID-MRI system using a non-resonant Cu wound flux transformer to image food with a shorter relaxation time. As a result, $\rm T_1$ - weighted images of samples containing water and oil could be acquired by varying the polarizing time.- 11 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-4
Portable Cryostat With Temperature Control Function for Operation of HTS-SQUID at a Higher Slew Rate
We examined a portable cryostat utilizing liquid nitrogen with temperature control function for operation of high-temperature superconducting quantum interference devices (HTS-SQUIDs) to have a higher slew rate. To operate a non-destructive evaluation system with HTS-SQUID in city areas with serious environmental electromagnetic noise, we often need a higher slew rate. A glass Dewar is installed in an outer case made of aluminum, which is sealed hermetically. The temperature of liquid nitrogen is controlled by using a vacuum pump connected to a feedback circuit, which monitors the temperature of liquid nitrogen. The temperature of liquid nitrogen could be controlled in the range between 73 and 77.2 K with a 0.1 K step. For example, the temperature was kept at 75 K with precision of ±0.05 K for 9 hs and SQUID was operated stably for this period. The Δ V and the slew rate of a test SQUID were increased from 22 μV and 3.2 mT/s at 77.2 K to 37 μV and 5.9 mT/s at 73 K, respectively. The white noise was also improved from 48 fT/√Hz at 77.2 K to 32 fT/√Hz at 74 K. We believe that this technology is useful to extend application of HTS-SQUIDs in the fields.
- 11 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-4
Portable Cryostat With Temperature Control Function for Operation of HTS-SQUID at a Higher Slew Rate
We examined a portable cryostat utilizing liquid nitrogen with temperature control function for operation of high-temperature superconducting quantum interference devices (HTS-SQUIDs) to have a higher slew rate. To operate a non-destructive evaluation system with HTS-SQUID in city areas with serious environmental electromagnetic noise, we often need a higher slew rate. A glass Dewar is installed in an outer case made of aluminum, which is sealed hermetically. The temperature of liquid nitrogen is controlled by using a vacuum pump connected to a feedback circuit, which monitors the temperature of liquid nitrogen. The temperature of liquid nitrogen could be controlled in the range between 73 and 77.2 K with a 0.1 K step. For example, the temperature was kept at 75 K with precision of ±0.05 K for 9 hs and SQUID was operated stably for this period. The Δ V and the slew rate of a test SQUID were increased from 22 μV and 3.2 mT/s at 77.2 K to 37 μV and 5.9 mT/s at 73 K, respectively. The white noise was also improved from 48 fT/√Hz at 77.2 K to 32 fT/√Hz at 74 K. We believe that this technology is useful to extend application of HTS-SQUIDs in the fields.
- 7 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-4
Long Period of Time Cooling Technique Using Liquid Nitrogen for HTS-SQUID System
We examined the design method of a glass Dewar for liquid nitrogen as a cooling apparatus of an HTS-SQUID system for field use. Cooling technique without stressing operators is very important. Though cooling technique using liquid nitrogen is suitable to cool HTS-SQUIDs fast at an operation site and operate them without additional noise, the operation time of SQUIDs is often limited by the holding time of liquid nitrogen. To design a system with adequate size and operation time, it is important to estimate the holding time of the cryostat. We calculated the heat inflow due to thermal conduction through the glass Dewar, probe rod, wirings to the SQUID, silver coating on the glass, heat insulator, and nitrogen gas, as well as the heat radiation from the surface of the heat insulator. We compared these results with the measured data for three types of glass Dewar. We successfully develop a simple model to calculate the holding time of the Dewar, and achieved the holding time of over 100 hours for 0.8 liters of liquid nitrogen.
- 7 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-4
Long Period of Time Cooling Technique Using Liquid Nitrogen for HTS-SQUID System
We examined the design method of a glass Dewar for liquid nitrogen as a cooling apparatus of an HTS-SQUID system for field use. Cooling technique without stressing operators is very important. Though cooling technique using liquid nitrogen is suitable to cool HTS-SQUIDs fast at an operation site and operate them without additional noise, the operation time of SQUIDs is often limited by the holding time of liquid nitrogen. To design a system with adequate size and operation time, it is important to estimate the holding time of the cryostat. We calculated the heat inflow due to thermal conduction through the glass Dewar, probe rod, wirings to the SQUID, silver coating on the glass, heat insulator, and nitrogen gas, as well as the heat radiation from the surface of the heat insulator. We compared these results with the measured data for three types of glass Dewar. We successfully develop a simple model to calculate the holding time of the Dewar, and achieved the holding time of over 100 hours for 0.8 liters of liquid nitrogen.
- 23 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-5
Development of Eddy Current Testing System Using HTS-SQUID on a Hand Cart for Detection of Fatigue Cracks of Steel Plate Used in Expressways
We have been developing an HTS-SQUID eddy current testing (ECT) system using an HTS-SQUID module and external pickup coil made of Bi-2223 tape to investigate the feasibility of non-destructive evaluation of a steel plate paved with asphalt. In this work, a new excitation coil intended as a current dipole source is designed and evaluated. The current dipole coil can be expected to generate a unidirectional excitation field and exhibit small field decay by distance, and thus seems suitable for a measurement under a long liftoff condition such as the case for crack detection through an asphalt pavement. It is also found that a strong single peak appears just above a slit hole as a simulated crack by applying the excitation field using a tilted current dipole coil. The developed measurement system was mounted on a hand cart, and successful detection of a 50 mm long slit hole and its stable operation were demonstrated in a field operation test.
- 23 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-5
Development of Eddy Current Testing System Using HTS-SQUID on a Hand Cart for Detection of Fatigue Cracks of Steel Plate Used in Expressways
We have been developing an HTS-SQUID eddy current testing (ECT) system using an HTS-SQUID module and external pickup coil made of Bi-2223 tape to investigate the feasibility of non-destructive evaluation of a steel plate paved with asphalt. In this work, a new excitation coil intended as a current dipole source is designed and evaluated. The current dipole coil can be expected to generate a unidirectional excitation field and exhibit small field decay by distance, and thus seems suitable for a measurement under a long liftoff condition such as the case for crack detection through an asphalt pavement. It is also found that a strong single peak appears just above a slit hole as a simulated crack by applying the excitation field using a tilted current dipole coil. The developed measurement system was mounted on a hand cart, and successful detection of a 50 mm long slit hole and its stable operation were demonstrated in a field operation test.
- 8 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-4
Production of HTS-SQUID Magnetometer With Ramp-Edge Junctions Exhibiting Lowered Noise in AC Biasing Mode
We fabricated HTS-SQUID magnetometers with ramp-edge-type Josephson junctions and measured their noise properties using dc/ac biasing mode. Some exhibited lowered low-frequency noise by ac biasing and others did not. We compared various parameters to find correlative ones with effectiveness of ac biasing. We found that the junction width and the critical current density of the counter electrode layer were weakly correlated with the low-frequency noise. The narrower width and the higher density seemed to result in the lowered noise by apply-ing ac bias current. It is likely that disorder in the counter electrode and/or disorder in the underlying barrier region give rise to fluctuation of inhomogeneous current flow in junctions or flux trapping, leading to low-frequency noise which cannot be reduced by ac biasing. Generation probability of such inhomogeneous portion seems to be reduced by making narrow junctions. High quality electrode seems to contain lesser disorder causing flux trapping.
- 8 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (4) , 1-4
Production of HTS-SQUID Magnetometer With Ramp-Edge Junctions Exhibiting Lowered Noise in AC Biasing Mode
We fabricated HTS-SQUID magnetometers with ramp-edge-type Josephson junctions and measured their noise properties using dc/ac biasing mode. Some exhibited lowered low-frequency noise by ac biasing and others did not. We compared various parameters to find correlative ones with effectiveness of ac biasing. We found that the junction width and the critical current density of the counter electrode layer were weakly correlated with the low-frequency noise. The narrower width and the higher density seemed to result in the lowered noise by apply-ing ac bias current. It is likely that disorder in the counter electrode and/or disorder in the underlying barrier region give rise to fluctuation of inhomogeneous current flow in junctions or flux trapping, leading to low-frequency noise which cannot be reduced by ac biasing. Generation probability of such inhomogeneous portion seems to be reduced by making narrow junctions. High quality electrode seems to contain lesser disorder causing flux trapping.