GUGian Paolo Ussia

Gian Paolo Ussia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gian Paolo Ussia has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Impact of burden and distribution of aortic valve calcification on the hemodynamic performance and procedural outcomes of a self-expanding, intra-annular transcatheter aortic valve system

    by Annunziata Nusca, Michele Mattia Viscusi, Simone Circhetta, Valeria Cammalleri, Fabio Mangiacapra, Elisabetta Ricottini, Rosetta Melfi, Paolo Gallo, Nino Cocco, Raffaele Rinaldi, et al.

    Aortic valve calcification (AVC) has been explored as a powerful predictor of procedural complications in patients undergoing transcatheter aortic valve implantation (TAVI). However, little evidence exists on its impact on intra-annular devices’ performance. We aimed to investigate the impact of AVC burden and distribution pattern on the occurrence of paravalvular leak (PVL), conduction disturbances requiring permanent pacemaker implantation (PPI) and 30-day clinical outcomes in patients undergoing TAVI with a self-expanding, intra-annular device. According to AVC, 103 patients enrolled in a single medical centre from November 2019 to December 2022 were divided into tertiles. Valve Academic Research Consortium (VARC)-3 definitions were used to classify procedural complications and outcomes. Patients in the highest AVC tertile showed an increased occurrence of mild or more PVL and conduction disorders (p < 0.001 and p = 0.006). AVC tertiles (highest tertile) emerged as an independent predictor of PVL (OR 7.32, 95%CI 3.10-17.28, p < 0.001) and post-TAVI conduction disturbances (OR 3.73, 95%CI 1.31–10.60, p = 0.013) but not of PPI (OR 1.44, 95%CI 0.39–5.35, p = 0.579). Considering calcium distribution, ROC analyses revealed that annular AVC but not left ventricle outflow tract (LVOT) calcium burden significantly indicated the development of PVL (AUC 0.863, 0.77–0.93, p < 0.001) and conduction disorders/PPI (AUC 0.797, 0.70–0.89, p < 0.001 and 0.723, 0.58–0.86, p = 0.018, respectively). After adjustment for age and sex, the highest tertile remained an independent predictor of the 30-day composite outcome (death, myocardial infarction, stroke, major vascular complications, type 3/4 bleedings, acute kidney injury, PPI and ≥ moderate PVL) (OR 3.26; 95%CI 1.26–8.40, p = 0.014). A higher AVC is associated with an increased risk of PVL and conduction disturbances after TAVI with a self-expanding, intra-annular device. However, our findings suggest a minor role for LVOT calcification compared with annular AVC in the performance of this specific prosthesis.


  • Combined procedure of transcatheter aortic valve replacement and coronary intravascular lithotripsy

    by Elisabetta Ricottini, Myriam Carpenito, Annunziata Nusca, Rosetta Melfi, Raffaele Rinaldi, Francesco Grigioni, Gian Paolo Ussia


  • Open Access

    Invasive Assessment of Coronary Microvascular Function

    by Fabio Mangiacapra, Michele Mattia Viscusi, Giuseppe Verolino, Luca Paolucci, Annunziata Nusca, Rosetta Melfi, Gian Paolo Ussia, Francesco Grigioni

    The critical role of the coronary microvascular compartment and its invasive functional assessment has become apparent in light of the significant proportion of patients presenting signs and symptoms of myocardial ischemia, despite the absence of epicardial disease, or after the adequate treatment of it. However, coronary microvascular dysfunction (CMD) represents a diagnostic challenge because of the small dimensions of the coronary microvasculature, which prevents direct angiographic visualization. Several diagnostic tools are now available for the invasive assessment of the coronary microvascular function, which, in association with the physiological indices used to investigate the epicardial department, may provide a comprehensive evaluation of the coronary circulation as a whole. Recent evidence suggests that the physiology-guided management of CMD, although apparently costly and time-consuming, may offer a net clinical benefit in terms of symptom improvement among patients with angina and ischemic heart disease. However, despite the results of several observational studies, the prognostic effect of the physiology-driven management of CMD within this population is currently a matter of debate, and therefore represents an unmet clinical need that urgently deserves further investigation.


  • Open Access

    One-Year Outcomes after Surgical versus Transcatheter Aortic Valve Replacement with Newer Generation Devices

    by Stefano Rosato, Fausto Biancari, Paola D’errigo, Marco Barbanti, Giuseppe Tarantini, Francesco Bedogni, Marco Ranucci, Giuliano Costa, Tatu Juvonen, Gian Paolo Ussia, et al.

    The superiority of transcatheter (TAVR) over surgical aortic valve replacement (SAVR) for severe aortic stenosis (AS) has not been fully demonstrated in a real-world setting. This prospective study included 5706 AS patients who underwent SAVR from 2010 to 2012 and 2989 AS patients who underwent TAVR from 2017 to 2018 from the prospective multicenter observational studies OBSERVANT I and II. Early adverse events as well as all-cause mortality, major adverse cardiac and cerebrovascular events (MACCEs), and hospital readmission due to heart failure at 1-year were investigated. Among 1008 propensity score matched pairs, TAVR was associated with significantly lower 30-day mortality (1.8 vs. 3.5%, p = 0.020), stroke (0.8 vs. 2.3%, p = 0.005), and acute kidney injury (0.6 vs. 8.2%, p < 0.001) compared to SAVR. Moderate-to-severe paravalvular regurgitation (5.9 vs. 2.0%, p < 0.001) and permanent pacemaker implantation (13.8 vs. 3.3%, p < 0.001) were more frequent after TAVR. At 1-year, TAVR was associated with lower risk of all-cause mortality (7.9 vs. 11.5%, p = 0.006), MACCE (12.0 vs. 15.8%, p = 0.011), readmission due to heart failure (10.8 vs. 15.9%, p < 0.001), and stroke (3.2 vs. 5.1%, p = 0.033) compared to SAVR. TAVR reduced 1-year mortality in the subgroups of patients aged 80 years or older (HR 0.49, 95% CI 0.33–0.71), in females (HR 0.57, 0.38–0.85), and among patients with EuroSCORE II ≥ 4.0% (HR 0.48, 95% CI 0.32–0.71). In a real-world setting, TAVR using new-generation devices was associated with lower rates of adverse events up to 1-year follow-up compared to SAVR.


  • Severe calcified paravalvular leak: usefulness of intravascular lithotripsy technology

    by Elisabetta Ricottini, Myriam Carpenito, Simona Mega, Gian Paolo Ussia

    The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)