Mirella M. C. Molenschot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mirella M. C. Molenschot has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Gregor Krings
Cleveland Clinic, Cleveland, OH
8 shared publications - Johannes M. P. J. Breur
Department of Pediatric Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands
5 shared publications - Michiel Voskuil
Department of Cardiology, University Medical Center Utrecht , Utrecht
3 shared publications - Femke van der Stelt
Department of Pediatric Cardiology, Wilhelmina Children's Hospital, University Medical Center Utrecht, Lundlaan 6, P.O. Box 85090, 3508 AB, Utrecht, the Netherlands
2 shared publications - Timion A. Meijs
Department of Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands
2 shared publications - Allard E. van Ark
Department of Pediatric Cardiology, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 14 September 2026
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 13 (9) , 463
Airway Management in Fontan Patients with LPA Stenosis
Left pulmonary artery (LPA) stenosis is encountered in up to 65% of patients with a Fontan circulation. Stenting of LPA stenosis can be complicated by compression of the left bronchus. We evaluated the effect of periprocedural airway management with three-dimensional rotational angiography (3DRA) and bronchoscopy on the occurrence of left main bronchus compression in Fontan patients undergoing percutaneous treatment for LPA stenosis. All pediatric cardiac catheterizations for LPA stenosis between 2011 and 2024 as well as the pre- and postoperative course were analyzed. In 64 of a total of 109 procedures airway imaging was used (3DRA (n = 50), bronchoscopy (n = 1), bronchoscopy and 3DRA (n = 13)). Airway imaging led to an adaptation of the intervention in 43 cases; stent ovalization was performed in 23 cases, balloon interrogation with simultaneous airway visualization was performed in 24 cases and the intended procedure was abandoned in two cases. In six cases balloon dilatation of a compressed left main bronchus was performed with mild success in two cases where balloon dilatation led to altered LPA stent morphology increasing the lumen of the left main bronchus. Thus, the left main bronchus is at high risk for compression when LPA stenting is performed in patients with a Fontan circulation. Periprocedural imaging of the airway has the potential to prevent airway compression. Bronchus dilatation offered no successful treatment for airway compression by an LPA stent.
- 14 September 2026
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 13 (9) , 463
Open AccessAirway Management in Fontan Patients with LPA Stenosis
Left pulmonary artery (LPA) stenosis is encountered in up to 65% of patients with a Fontan circulation. Stenting of LPA stenosis can be complicated by compression of the left bronchus. We evaluated the effect of periprocedural airway management with three-dimensional rotational angiography (3DRA) and bronchoscopy on the occurrence of left main bronchus compression in Fontan patients undergoing percutaneous treatment for LPA stenosis. All pediatric cardiac catheterizations for LPA stenosis between 2011 and 2024 as well as the pre- and postoperative course were analyzed. In 64 of a total of 109 procedures airway imaging was used (3DRA (n = 50), bronchoscopy (n = 1), bronchoscopy and 3DRA (n = 13)). Airway imaging led to an adaptation of the intervention in 43 cases; stent ovalization was performed in 23 cases, balloon interrogation with simultaneous airway visualization was performed in 24 cases and the intended procedure was abandoned in two cases. In six cases balloon dilatation of a compressed left main bronchus was performed with mild success in two cases where balloon dilatation led to altered LPA stent morphology increasing the lumen of the left main bronchus. Thus, the left main bronchus is at high risk for compression when LPA stenting is performed in patients with a Fontan circulation. Periprocedural imaging of the airway has the potential to prevent airway compression. Bronchus dilatation offered no successful treatment for airway compression by an LPA stent.
- Open Access
- 1 March 2022
- Published by Elsevier in International Journal of Cardiology Congenital Heart Disease
- Vol. 7, 100306
To treat or not to treat pulmonary arteries: epinephrine provocation to unmask right ventricular load
- 1 March 2022
- Published by Elsevier in International Journal of Cardiology Congenital Heart Disease
- Vol. 7, 100306
Open AccessTo treat or not to treat pulmonary arteries: epinephrine provocation to unmask right ventricular load
- 16 January 2022
- Published by Springer Nature in Pediatric Cardiology
- Vol. 43 (3) , 704-708
Troubled Judging of Bronchus Compression Due to Contrast-Filled Balloon in Three-Dimensional Rotational Angiography
Three-dimensional rotational angiography (3DRA) is a suitable technique to detect the risk of left main bronchus (LMB) compression during left pulmonary artery (LPA) stenting in partial cavopulmonary connection and total cavopulmonary connection (TCPC). We report on a case of a 4-year-old boy with hypoplastic left heart syndrome and TCPC in which 3DRA and bronchoscopy gave conflicting information on airway patency during balloon interrogation. The balloon with high contrast concentration created a severe artifact impeding visibility of the LMB. Simultaneous flexible bronchoscopy revealed an unobstructed LMB. Repeated 3DRAs with lower contrast concentration had no artifact and showed a patent airway in accordance with the bronchoscopy. Conventional LPA stenting was performed without indication for stent ovalization. The benefit of low contrast concentration in the interrogation balloon was demonstrated in a second case of an 11-year-old boy with TCPC. The margins of the LPA and LMB were clearly visible without blank-out artifact. Oval stent procedure was necessary to prevent LMB compression. When 3DRA is used for vessel–airway interrogation, the balloon contrast concentration should be low in order to avoid artifacts. When in doubt, simultaneous flexible bronchoscopy can overcome the dilemma in airway judgment.
- 16 January 2022
- Published by Springer Nature in Pediatric Cardiology
- Vol. 43 (3) , 704-708
Troubled Judging of Bronchus Compression Due to Contrast-Filled Balloon in Three-Dimensional Rotational Angiography
Three-dimensional rotational angiography (3DRA) is a suitable technique to detect the risk of left main bronchus (LMB) compression during left pulmonary artery (LPA) stenting in partial cavopulmonary connection and total cavopulmonary connection (TCPC). We report on a case of a 4-year-old boy with hypoplastic left heart syndrome and TCPC in which 3DRA and bronchoscopy gave conflicting information on airway patency during balloon interrogation. The balloon with high contrast concentration created a severe artifact impeding visibility of the LMB. Simultaneous flexible bronchoscopy revealed an unobstructed LMB. Repeated 3DRAs with lower contrast concentration had no artifact and showed a patent airway in accordance with the bronchoscopy. Conventional LPA stenting was performed without indication for stent ovalization. The benefit of low contrast concentration in the interrogation balloon was demonstrated in a second case of an 11-year-old boy with TCPC. The margins of the LPA and LMB were clearly visible without blank-out artifact. Oval stent procedure was necessary to prevent LMB compression. When 3DRA is used for vessel–airway interrogation, the balloon contrast concentration should be low in order to avoid artifacts. When in doubt, simultaneous flexible bronchoscopy can overcome the dilemma in airway judgment.
- Open Access
- 1 August 2021
- Published by Elsevier in International Journal of Cardiology Congenital Heart Disease
- Vol. 4, 100190
Stent interventions guided by three-dimensional rotational angiography to treat total cavopulmonary connection stenosis
- 1 August 2021
- Published by Elsevier in International Journal of Cardiology Congenital Heart Disease
- Vol. 4, 100190
Open AccessStent interventions guided by three-dimensional rotational angiography to treat total cavopulmonary connection stenosis
- Open Access
- 29 November 2019
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 28 (3) , 145-152
Safety and efficacy of stenting for aortic arch hypoplasia in patients with coarctation of the aorta
Background: Despite a successful repair procedure for coarctation of the aorta (CoA), up to two-thirds of patients remain hypertensive. CoA is often seen in combination with abnormal aortic arch anatomy and morphology. This might be a substrate for persistent hypertension. Therefore, we performed endovascular aortic arch stent placement in patients with CoA and concomitant aortic arch hypoplasia or gothic arch morphology. The goal of this retrospective analysis was to investigate the safety and efficacy of aortic arch stenting.Methods: A retrospective analysis was performed in patients who underwent stenting of the aortic arch at the University Medical Center Utrecht. Measurements collected included office blood pressure, use of antihypertensive medication, invasive peak-to-peak systolic pressure over the arch, and aortic diameters on three-dimensional angiography. Data on follow-up were obtained at the date of most recent outpatient visit.Results: Twelve patients underwent stenting of the aortic arch. Mean follow-up duration was 14 ± 11 months. Mean peak-to-peak gradient across the arch decreased from 39 ± 13 mm Hg to 7 ± 8 mm Hg directly after stenting (p < 0.001). There were no major procedural complications. Mean systolic blood pressure decreased from 145 ± 16 mm Hg at baseline to 128 ± 9 mm Hg at latest follow-up (p = 0.014).Conclusion: This retrospective study shows that stenting of the aortic arch is successful when carried out in a state-of-the-art manner. A direct optimal angiographic and haemodynamic result was shown. No major complications occurred during or after the procedure. At short- to medium-term follow-up a decrease in mean systolic blood pressure was observed.
- 29 November 2019
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 28 (3) , 145-152
Open AccessSafety and efficacy of stenting for aortic arch hypoplasia in patients with coarctation of the aorta
Background: Despite a successful repair procedure for coarctation of the aorta (CoA), up to two-thirds of patients remain hypertensive. CoA is often seen in combination with abnormal aortic arch anatomy and morphology. This might be a substrate for persistent hypertension. Therefore, we performed endovascular aortic arch stent placement in patients with CoA and concomitant aortic arch hypoplasia or gothic arch morphology. The goal of this retrospective analysis was to investigate the safety and efficacy of aortic arch stenting.Methods: A retrospective analysis was performed in patients who underwent stenting of the aortic arch at the University Medical Center Utrecht. Measurements collected included office blood pressure, use of antihypertensive medication, invasive peak-to-peak systolic pressure over the arch, and aortic diameters on three-dimensional angiography. Data on follow-up were obtained at the date of most recent outpatient visit.Results: Twelve patients underwent stenting of the aortic arch. Mean follow-up duration was 14 ± 11 months. Mean peak-to-peak gradient across the arch decreased from 39 ± 13 mm Hg to 7 ± 8 mm Hg directly after stenting (p < 0.001). There were no major procedural complications. Mean systolic blood pressure decreased from 145 ± 16 mm Hg at baseline to 128 ± 9 mm Hg at latest follow-up (p = 0.014).Conclusion: This retrospective study shows that stenting of the aortic arch is successful when carried out in a state-of-the-art manner. A direct optimal angiographic and haemodynamic result was shown. No major complications occurred during or after the procedure. At short- to medium-term follow-up a decrease in mean systolic blood pressure was observed.
- Open Access
- 7 August 2019
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 94 (7) , 1006-1009
Endovascular coil embolization of a complex aortic arch pseudoaneurysm following arch stenting
Pseudoaneurysm formation is a life‐threatening complication of thoracic aortic stenting due to the high risk of rupture. When located in the aortic arch, anatomic features may pose difficulties in choosing the optimal treatment strategy. Here, we describe the first poststenting aortic arch pseudoaneurysm treated by endovascular coil embolization. This approach, which we performed in a multidisciplinary setting, may be a feasible alternative in patients not considered suitable for open repair or stent‐grafting. As an acute pseudoaneurysm may develop and rapidly expand during the first days after aortic stenting, early follow‐up imaging is preferable.
- 7 August 2019
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 94 (7) , 1006-1009
Open AccessEndovascular coil embolization of a complex aortic arch pseudoaneurysm following arch stenting
Pseudoaneurysm formation is a life‐threatening complication of thoracic aortic stenting due to the high risk of rupture. When located in the aortic arch, anatomic features may pose difficulties in choosing the optimal treatment strategy. Here, we describe the first poststenting aortic arch pseudoaneurysm treated by endovascular coil embolization. This approach, which we performed in a multidisciplinary setting, may be a feasible alternative in patients not considered suitable for open repair or stent‐grafting. As an acute pseudoaneurysm may develop and rapidly expand during the first days after aortic stenting, early follow‐up imaging is preferable.
- Open Access
- 24 January 2019
- Published by Springer Nature in Pediatric Cardiology
- Vol. 40 (2) , 257-264
Three-Dimensional Rotational Angiography in Pediatric Patients with Congenital Heart Disease: A Literature Review
Cardiac catheterization is a commonly used form of imaging and treatment in pediatric patients with congenital heart disease. Traditionally, two-dimensional conventional angiography was the method used, but since 2000 three-dimensional rotational angiography (3DRA) is increasingly used in the field of cardiology in both adult and pediatric patients. To investigate the use and applications of 3DRA in pediatric congenital cardiology, literature was systematically reviewed and 29 eligible articles were found. Those showed that 3DRA is already a greatly valued diagnostic and therapeutic technique in pediatric cardiology. However, the literature misses well-designed clinical, homogeneous, multicenter, prospective studies recording data in a standardized manner. These studies are necessary to ensure proper data analysis and to investigate the true advantages of 3DRA and how it exactly benefits the patients.
- 24 January 2019
- Published by Springer Nature in Pediatric Cardiology
- Vol. 40 (2) , 257-264
Open AccessThree-Dimensional Rotational Angiography in Pediatric Patients with Congenital Heart Disease: A Literature Review
Cardiac catheterization is a commonly used form of imaging and treatment in pediatric patients with congenital heart disease. Traditionally, two-dimensional conventional angiography was the method used, but since 2000 three-dimensional rotational angiography (3DRA) is increasingly used in the field of cardiology in both adult and pediatric patients. To investigate the use and applications of 3DRA in pediatric congenital cardiology, literature was systematically reviewed and 29 eligible articles were found. Those showed that 3DRA is already a greatly valued diagnostic and therapeutic technique in pediatric cardiology. However, the literature misses well-designed clinical, homogeneous, multicenter, prospective studies recording data in a standardized manner. These studies are necessary to ensure proper data analysis and to investigate the true advantages of 3DRA and how it exactly benefits the patients.
- 1 October 2018
- Published by Elsevier in International Journal of Cardiology
- Vol. 268, 202-207
The Y-stenting technique for pulmonary artery bifurcation stenosis: Initial results and mid-term outcomes
- 1 October 2018
- Published by Elsevier in International Journal of Cardiology
- Vol. 268, 202-207
The Y-stenting technique for pulmonary artery bifurcation stenosis: Initial results and mid-term outcomes
- Open Access
- 25 June 2018
- Published by S. Karger AG in Neonatology
- Vol. 114 (3) , 198-204
Cardiac Valve Annulus Diameters in Extremely Preterm Infants: A Cross-Sectional Echocardiographic Study
Background: With the increasing incidence of births of very preterm very-low-birth-weight infants, there is a demand for echocardiographic reference values of cardiac dimensions. Objectives: The aim of this study was to provide reference values of cardiac valve annulus diameters in a cohort of extremely preterm very-low-birth-weight neonates and to correlate these with patient characteristics. Methods: Valve diameters of 376 infants of < 32 weeks’ gestation and with a birth weight of ≤2,000 g were measured using 2-dimensional echocardiography. Correlations between valve diameters and patient characteristics (birth length/weight, body surface area, gestational age, and sex) were assessed. Birth weight was used to establish linear regression models. Inter- and intraobserver agreement was assessed through intraclass correlation coefficient (ICC) analysis. Results: Substantial variability was found (aortic valve mean [standard deviation; range]: 5.0 mm [0.6; 3.7–6.5]; pulmonic valve: 5.8 mm [0.8; 3.4–7.9]; mitral valve: 8.0 mm [1.0; 5.5–10.5]; tricuspid valve: 7.6 mm [1.2; 4.9–10.6]). There was a moderate correlation between birth weight and valve diameter (R2 aortic valve: 0.36; pulmonic valve: 0.20; mitral valve: 0.24; tricuspid valve: 0.24). Adequate intraobserver (ICC range 0.74–0.91) and interobserver agreement (ICC range 0.77–0.89) was found. Conclusions: Our study provides ready-to-use reference values for cardiac valve annulus diameters for extremely preterm infants.
- 25 June 2018
- Published by S. Karger AG in Neonatology
- Vol. 114 (3) , 198-204
Open AccessCardiac Valve Annulus Diameters in Extremely Preterm Infants: A Cross-Sectional Echocardiographic Study
Background: With the increasing incidence of births of very preterm very-low-birth-weight infants, there is a demand for echocardiographic reference values of cardiac dimensions. Objectives: The aim of this study was to provide reference values of cardiac valve annulus diameters in a cohort of extremely preterm very-low-birth-weight neonates and to correlate these with patient characteristics. Methods: Valve diameters of 376 infants of < 32 weeks’ gestation and with a birth weight of ≤2,000 g were measured using 2-dimensional echocardiography. Correlations between valve diameters and patient characteristics (birth length/weight, body surface area, gestational age, and sex) were assessed. Birth weight was used to establish linear regression models. Inter- and intraobserver agreement was assessed through intraclass correlation coefficient (ICC) analysis. Results: Substantial variability was found (aortic valve mean [standard deviation; range]: 5.0 mm [0.6; 3.7–6.5]; pulmonic valve: 5.8 mm [0.8; 3.4–7.9]; mitral valve: 8.0 mm [1.0; 5.5–10.5]; tricuspid valve: 7.6 mm [1.2; 4.9–10.6]). There was a moderate correlation between birth weight and valve diameter (R2 aortic valve: 0.36; pulmonic valve: 0.20; mitral valve: 0.24; tricuspid valve: 0.24). Adequate intraobserver (ICC range 0.74–0.91) and interobserver agreement (ICC range 0.77–0.89) was found. Conclusions: Our study provides ready-to-use reference values for cardiac valve annulus diameters for extremely preterm infants.
- Open Access
- 1 April 2001
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 71 (4) , 1346-1347
Aneurysmal pericardial patch producing right ventricular inflow obstruction
- 1 April 2001
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 71 (4) , 1346-1347
Open AccessAneurysmal pericardial patch producing right ventricular inflow obstruction