BCBeth Catlett

Beth Catlett

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Beth Catlett has a total of 92 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Co‐Producing a Patient Reported Experience Measure (PREM) With and for People With Intellectual Disability

    by Bronwyn Newman, Ling Wu, Laurel Mimmo, Beth Catlett, Matthew Van Hoeke, Maya Tokutake, Karen Phillips, Deborah Van Hoeke, Kim Bowen, Dalal Dawood Baumgarter, et al.

    Background: Patient reported experience measures (PREMs) are widely used as key indicators of value in healthcare towards improved services but are rarely applied among people with intellectual disability. Incorporating the experiences of people with intellectual disability in PREMs data is vital as this group often encounter poor healthcare access and outcomes. This study reports the coproduction of accessible PREMs for people with intellectual disability from a 3‐year inclusive research project called Listen to Me. Objective: To coproduce a PREM suitable for people with intellectual disability. Method: Co‐production occurred through inclusive data collection methods in five hybrid co‐production workshops within an inclusive research project structure. Preliminary user testing of the Listen to Me PREM was conducted via semi‐structured interviews using the ‘think aloud’ method. Results: Co‐production included two people with intellectual disability, six people who support family members with intellectual disability, three researchers and three people with experience health service management or direct care. Preliminary user testing was completed by 11 people with intellectual disability with a range of communication needs and preferences. The resulting 9‐item Listen to Me PREMs are digitally‐enabled tools that include accessible features, such as large font and audible options to enable completion directly by people with a range of communication approaches. Conclusion: The Listen to Me PREMs provide an innovative tool to capture patent‐reported experiences directly from people with intellectual disability. By applying tools such as the Listen to Me PREMs, health services are better equipped to identify opportunities for improvement, to enhance access, quality and outcomes in health care delivery for consumers with high healthcare needs. Patient or Public Contribution: People with diverse abilities and communication preferences have been engaged both as members of the Listen to Me research team, and in all elements of data collection. The Listen to Me project has grown from a collaboration with consumers and all elements of this research engage with a diverse consumer group. The CanEngage Consumer Leadership Group (CLG) is central to all research activities including governance, data collection, analysis, preparation and dissemination of findings. The CLG has eight members, two members have intellectual disability and six are parents or siblings who support family members with intellectual disability to access health care. The CLG were involved in the design of the research proposal, reviewing and contributing to the ethics protocols, the coproduction of the Patient reported experience measure (PREM) and as authors of this paper. People who support family members with intellectual disability to access healthcare were involved in constructing and editing the paper. Two people with intellectual disability were involved in reviewing the accessible summary of the paper and provided feedback on clarity. Some authors are family members of people living with an intellectual disability. These family members are crucial advocates for people with a severe intellectual disability who do not have the capacity or capability of communicating using speech or writing.


  • Open Access

    Co‐Producing Patient‐Reported Experience Measures With People With Intellectual Disability to Improve Healthcare Quality and Outcomes: The ‘Listen to Me’ Project Protocol

    by Reema Harrison, Bronwyn Newman, Beth Catlett, Laurel Mimmo, Ling Wu, Maya Tokutake, Karen Phillips, Matthew Van Hoek, Debbie Van Hoek, Elizabeth Manias, et al.

    Introduction: Intellectual disability, defined by significant limitations in both intellectual functioning and adaptive behaviour with onset during the developmental period, affects an estimated 2% (108 million) of people worldwide. People with intellectual disability experience major health inequity, poor health outcomes and premature deaths, with mortality rates that are 7–12 times higher than the general population. Patient‐reported experience measures (PREMs) are used worldwide to target improvements in healthcare delivery. Yet, systematic review evidence confirms that people with intellectual disability are excluded from PREMs due to a lack of suitable measurement instruments and supports. To improve healthcare quality and outcomes, people with intellectual disability and their supporters, and academic and clinician researchers will together Coproduce PREMs for, and with, this population apply the PREM in hospitals and use the data to inform local quality improvement projects. Methods and Analysis: Our 3‐year project employs a multi‐method design using coproduction, underpinned by an implementation science framework. We will coproduce PREMs that will be applied to improve healthcare quality and outcomes for people with intellectual disability whilst engaging in co‐research with people with lived experience of having an intellectual disability and their carers, clinicians and academic researchers. Study 1 will coproduce PREMs for use by people with intellectual disability to report their experiences of inpatient hospital care. Study 2 will use the co‐produced PREMs to capture the experiences of people with intellectual disability as inpatients in Australian hospitals; determine PREMs reliability and validity; and costs associated with use. Study 3 will develop the required capability to translate our PREMs into hospitals across Australia. Study 4 will apply PREMs data via continuous quality improvement in partnering hospitals to reduce preventable healthcare associated harm, hospitalisation, and prolonged length of stay experienced by people with intellectual disability. Study 5 will provide a process evaluation of our co‐research approach. Quantitative and qualitative analysis will be undertaken, and results will be examined against the project aims. Ethics and Dissemination: Ethical approval has been obtained (520241735259588; X24‐0366; 115771). This study is being conducted with partner health agencies and services nationally in Australia to support achievement of the research aims and translation of findings into practice. Targeted outputs with research dissemination will be guided by, and in collaboration with, the project Consumer Leadership Group, consumer and health system stakeholders, with governance from the Project Steering Group. Patient or Public Contribution: The Listen to Me project has been designed and planned to ensure the involvement of people with a broad range of abilities, including those with profound intellectual disability who will be able to contribute along with their support person/s. The governance structure of Listen to Me is innovative and inclusive, with consumers providing leadership across all elements of the project. This is co‐research conceptualised and conducted with a Consumer Leadership Group (CLG) comprising eight people with lived experiences of intellectual disability; two of whom have an intellectual disability and six of whom are parents or siblings who support family members with intellectual disability. The CLG were involved in the design of the research proposal, reviewing and contributing to the ethics protocols, and the writing of this protocol as authors. The CLG will direct and contribute to all aspects of the research as part of the research team. An easy read summary of this protocol is provided in Supplementary file 1.


  • Diagnostic Accuracy of Assays Using Point-of-Care Testing or Dried Blood Spot Samples for the Determination of Hepatitis C Virus RNA: A Systematic Review

    by Beth Catlett, Behzad Hajarizadeh, Evan Cunningham, Brett Wolfson-Stofko, Alice Wheeler, Benazir Khandaker-Hussain, Jordan J Feld, Elisa Martró, Stéphane Chevaliez, Jean Michel Pawlotsky, et al.

    Background: Finger-stick point-of-care and dried blood spot (DBS) hepatitis C virus (HCV) RNA testing increases testing uptake and linkage to care. This systematic review evaluated the diagnostic accuracy of point-of-care testing and DBS to detect HCV RNA. Methods: Bibliographic databases and conference presentations were searched for eligible studies. Meta-analysis was used to pool estimates. Results: Of 359 articles identified, 43 studies were eligible and included. When comparing the Xpert HCV Viral Load Fingerstick assay to venous blood samples (7 studies with 987 samples), the sensitivity and specificity for HCV RNA detection was 99% (95% confidence interval [CI], 97%–99%) and 99% (95% CI, 94%–100%) and for HCV RNA quantification was 100% (95% CI, 93%–100%) and 100% (95% CI, 94%–100%). The proportion of invalid results following Xpert HCV Viral Load Fingerstick testing was 6% (95% CI, 3%–11%). When comparing DBS to venous blood samples (28 studies with 3988 samples) the sensitivity and specificity for HCV RNA detection was 97% (95% CI, 95%–98%) and 100% (95% CI, 98%–100%) and for HCV RNA quantification was 98% (95% CI, 96%–99%) and 100% (95% CI, 95%–100%). Conclusions: Excellent diagnostic accuracy was observed across assays for detection of HCV RNA from finger-stick and DBS samples. The proportion of invalid results following Xpert HCV Viral Load Fingerstick testing highlights the importance of operator training and quality assurance programs.


  • Evaluation of the Aptima HCV Quant Dx Assay for Hepatitis C Virus RNA Detection from Fingerstick Capillary Dried Blood Spot and Venepuncture-Collected Samples

    by Beth Catlett, Sahar Bajis, Mitchell Starr, Gregory J Dore, Behzad Hajarizadeh, Philip H Cunningham, Tanya L Applegate, Jason Grebely

    Simplified diagnostic strategies are needed increase hepatitis C virus (HCV) testing to determine active infection and link people into treatment. Collection methods such as dried blood spots (DBS) have advantages over standard phlebotomy, especially within marginalized populations. We evaluated the diagnostic performance of the Aptima HCV Quant assay for the quantification and detection of HCV RNA from paired DBS and venepuncture samples. Specimens were collected from participants enrolled in an Australian observational study. We compared HCV RNA detection from DBS against venepuncture samples (gold standard). One hundred sixty-four participants had paired samples and HCV RNA was detected in 45 (27% [95% confidence interval, 21%–35%]) by the Aptima assay in venepuncture samples. Sensitivity of the Aptima assay for HCV RNA quantification from DBS (≥10 IU/mL in plasma) was 100% and specificity was 100%. Sensitivity for HCV RNA detection from DBS was 95.6% and specificity was 94.1%. A small bias in plasma over DBS was observed with good agreement (R2 = 0.96). The Aptima HCV Quant assay detects active infection from DBS samples with acceptable diagnostic performance and is clinically comparable to plasma. These data will strengthen the case for the registration of a DBS kit insert claim, enabling future clinical utility.


  • Evaluation of a hepatitis C virus core antigen assay from venepuncture and dried blood spot collected samples: A cohort study

    by Beth Catlett, Francois M. J. Lamoury, Sahar Bajis, Behzad Hajarizadeh, Danica Martinez, Yasmin Mowat, Philip H. Cunningham, Brendan P. Jacka, Gavin A Cloherty, Philippa Marks, et al.

    The global scale‐up of hepatitis C virus (HCV) diagnosis requires simplified and affordable HCV diagnostic pathways. This study evaluated the sensitivity and specificity of the HCV Architect core antigen (HCVcAg) assay for detection of active HCV infection in plasma and capillary whole blood dried blood spots (DBS) compared with HCV RNA testing in plasma (Abbott RealTime HCV Viral Load). Samples were collected from participants in an observational cohort enrolled at three sites in Australia (two‐drug treatment and alcohol clinics and one homelessness service). Of 205 participants, 200 had results across all samples and assay types and 186 were included in this analysis (14 participants receiving HCV therapy were excluded). HCV RNA was detected in 29% of participants ([95% CI: 22.6‐36.1], 54 of 186). The sensitivity of HCVcAg for detection of active HCV infection in plasma was 98.1% (95% CI: 90‐100) and 100% (95% CI: 93‐100) when compared to HCV RNA thresholds of ≥12 and ≥1000 IU/mL, respectively. The sensitivity of the HCVcAg assay for detection of active HCV infection in DBS was 90.7% (95% CI: 80‐97) and 92.5% (95% CI: 82‐98) when compared to HCV RNA thresholds of ≥12 and ≥1000 IU/mL, respectively. The specificity of HCV core antigen for detection of active infection was 100% (95% CI: 97‐100) for all samples and RNA thresholds. These data indicate that the detection of HCVcAg is a useful tool for determining active HCV infection; to facilitate enhanced testing, linkage to care and treatment particularly when testing plasma samples are collected by venepuncture.


  • Performance evaluation of the Hologic Aptima HCV Quant Dx assay for detection of HCV RNA from dried blood spots

    by Beth Catlett, Alex Carrera, Mitchell Starr, Tanya L Applegate, Peter Lowe, Jason Grebely, H. Philip Cunningham


  • Open Access

    Evaluation of the Xpert HCV Viral Load Finger-Stick Point-of-Care Assay

    by Francois M J Lamoury, Sahar Bajis, Behzad Hajarizadeh, Alison D Marshall, Marianne Martinello, Elena Ivanova, Beth Catlett, Yasmin Mowat, Philippa Marks, Janaki Amin, et al.

    Point-of-care hepatitis C virus (HCV) RNA testing is advantageous, enabling diagnosis of active infection in a single visit. This study evaluated the sensitivity and specificity of the Xpert HCV Viral Load Finger-Stick assay (Xpert HCV VL FS) for HCV RNA detection (finger-stick) and the Xpert HCV Viral Load assay (plasma) compared with the Abbott RealTime HCV Viral Load assay by venepuncture. Plasma and finger-stick capillary whole-blood samples were collected from participants in an observational cohort in Australia. Of 223 participants enrolled, HCV RNA was detected in 40% of participants (85 of 210) with available Xpert HCV Viral Load testing. Participants receiving HCV therapy were excluded from subsequent analyses (n = 16). Sensitivity of the Xpert HCV Viral Load assay for HCV RNA quantification in plasma collected by venepuncture was 100.0% (95% confidence interval [CI] 96.9%–100.0%) and specificity was 100.0% (95% CI, 94.4%–100.0%). Sensitivity of the Xpert HCV VL FS assay for HCV RNA quantification in samples collected by finger-stick was 100.0% (95% CI, 93.9%–100.0%) and specificity was 100.0% (95% CI, 96.6%–100.0%). The Xpert HCV VL FS test can accurately detect active infection from a finger-stick sample in 1 hour allowing single-visit HCV diagnosis.


  • Estimating the cascade of hepatitis C testing, care and treatment among people who inject drugs in Australia

    by Jenny Iversen, Jason Grebely, Beth Catlett, Philip Cunningham, Gregory J. Dore, Lisa Maher


  • Evaluation of the Xpert HCV Viral Load point-of-care assay from venepuncture-collected and finger-stick capillary whole-blood samples: a cohort study

    by Jason Grebely, Francois M J Lamoury, Behzad Hajarizadeh, Yasmin Mowat, Alison D Marshall, Sahar Bajis, Philippa Marks, Janaki Amin, Julie Smith, Michael Edwards, et al.