Raju Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Raju Kumar has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
M. Jain
Department of Physics, Technical University of Denmark, DTU Risø Campus, 4000, Roskilde, Denmark
4 shared publicationsJean-Luc Schwenninger
3 shared publications- Mayank Jain
Technical University of Denmark
3 shared publications - Andrew Sean Murray
Department of Geoscience, Aarhus University, Aarhus, Denmark
2 shared publications D. Vandenberghe
Department of Geology, Ghent University, 9000, Ghent, Belgium
2 shared publicationsJ. De Grave
Department of Geology, Ghent University, 9000, Ghent, Belgium
2 shared publications
Latest Publications
- Open Access
- 18 April 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 246
Spatially resolved infrared-radiofluorescence (SR IR-RF) measurements for single-grain feldspar dating
- 18 April 2026
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 246
Open AccessSpatially resolved infrared-radiofluorescence (SR IR-RF) measurements for single-grain feldspar dating
- Open Access
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , C01010
Preparing Timepix3 for deployment in low-radioactivity natural settings: an integrated workflow for charged particle detection and imaging
The natural sedimentary environment possesses a mixed field of α-, β-, and γ-radiation emitted from the radioactive decay of radionuclides such as potassium-40 (K-40), uranium-238 (U-238), and thorium-232 (Th-232). These emissions are responsible for dose accumulation in feldspar and quartz mineral grains, forming the basis of luminescence dating. The inhomogeneous spatial distribution of radionuclides in sediments and local energy deposition at the grain level can cause microdosimetric variations, contributing to overdispersion in equivalent dose (D_e) distributions. Understanding and resolving these variations requires a detector that can simultaneously map various types of radiation and their energy deposition at the micron scale. Here we present a workflow for configuring and applying Timepix3 (silicon-based hybrid pixel detector, 14 × 14 mm 2 active area, 256 × 256 pixels, 300 μm thickness) for high-sensitivity imaging of α- and β-particles simultaneously in mixed-radiation fields. The workflow includes particle-track reconstruction, charged-particle identification, background suppression, and energy calibration with a mixed α-particle source (Pu-239, Am-241, Cm-244; 5.15–5.80 MeV) in air. A linear energy calibration response was obtained; however, the detector was unable to fully resolve three α-particle peaks. While this appears to be a limitation, it ultimately provides insights into the detector's response under conditions that closely mimic the energy spectra of natural radiation, broad energy distributions, and measurement conditions such as ambient atmospheric pressure.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , C01010
Open AccessPreparing Timepix3 for deployment in low-radioactivity natural settings: an integrated workflow for charged particle detection and imaging
The natural sedimentary environment possesses a mixed field of α-, β-, and γ-radiation emitted from the radioactive decay of radionuclides such as potassium-40 (K-40), uranium-238 (U-238), and thorium-232 (Th-232). These emissions are responsible for dose accumulation in feldspar and quartz mineral grains, forming the basis of luminescence dating. The inhomogeneous spatial distribution of radionuclides in sediments and local energy deposition at the grain level can cause microdosimetric variations, contributing to overdispersion in equivalent dose (D_e) distributions. Understanding and resolving these variations requires a detector that can simultaneously map various types of radiation and their energy deposition at the micron scale. Here we present a workflow for configuring and applying Timepix3 (silicon-based hybrid pixel detector, 14 × 14 mm 2 active area, 256 × 256 pixels, 300 μm thickness) for high-sensitivity imaging of α- and β-particles simultaneously in mixed-radiation fields. The workflow includes particle-track reconstruction, charged-particle identification, background suppression, and energy calibration with a mixed α-particle source (Pu-239, Am-241, Cm-244; 5.15–5.80 MeV) in air. A linear energy calibration response was obtained; however, the detector was unable to fully resolve three α-particle peaks. While this appears to be a limitation, it ultimately provides insights into the detector's response under conditions that closely mimic the energy spectra of natural radiation, broad energy distributions, and measurement conditions such as ambient atmospheric pressure.
- Open Access
- 11 January 2025
- Published by Cantonal and University Library Fribourg in Ancient TL
- Vol. 42 (2) , 3-13
A new reference block for field gamma spectrometry applications in ESR and luminescence dating
A new granite-doped concrete block with 60 cm x 60 cm x 60 cm dimensions has been built at CENIEH, Burgos, Spain, for dosimetry calibration and cross-referencing purposes. Independent evaluations of the block’s gamma dose rate using passive Al2O3:C dosimeters and various field gamma spectrometer (NaI) probes produce consistent results of 1495 ± 51 μGy a-1 and 1514 ± 43 μGy a-1 (or 1537 ± 19 μGy a-1, depending on the evaluation procedure employed), respectively. Bulk radioelement concentrations calculated from field gamma spectrometry using the Windows method are as follows: K = 1.58 ± 0.08 %, U = 4.26 ± 0.28 ppm, and Th = 12.62 ± 0.72 ppm. This new block complements existing dosimetry reference materials accessible at other laboratories and is available for the broader trapped charge dating community to use for instrument calibration, reproducibility assessments and intercomparison studies.
- 11 January 2025
- Published by Cantonal and University Library Fribourg in Ancient TL
- Vol. 42 (2) , 3-13
Open AccessA new reference block for field gamma spectrometry applications in ESR and luminescence dating
A new granite-doped concrete block with 60 cm x 60 cm x 60 cm dimensions has been built at CENIEH, Burgos, Spain, for dosimetry calibration and cross-referencing purposes. Independent evaluations of the block’s gamma dose rate using passive Al2O3:C dosimeters and various field gamma spectrometer (NaI) probes produce consistent results of 1495 ± 51 μGy a-1 and 1514 ± 43 μGy a-1 (or 1537 ± 19 μGy a-1, depending on the evaluation procedure employed), respectively. Bulk radioelement concentrations calculated from field gamma spectrometry using the Windows method are as follows: K = 1.58 ± 0.08 %, U = 4.26 ± 0.28 ppm, and Th = 12.62 ± 0.72 ppm. This new block complements existing dosimetry reference materials accessible at other laboratories and is available for the broader trapped charge dating community to use for instrument calibration, reproducibility assessments and intercomparison studies.
- 14 October 2022
- Published by Elsevier in Journal of Luminescence
- Vol. 252
Does hole instability cause anomalous fading of luminescence in feldspar?
- 14 October 2022
- Published by Elsevier in Journal of Luminescence
- Vol. 252
Does hole instability cause anomalous fading of luminescence in feldspar?
- Open Access
- 25 April 2022
- Published by Elsevier in Radiation Measurements
- Vol. 154, 106761
OxGamma: A MATLAB based application for the analysis of gamma-ray spectra
- 25 April 2022
- Published by Elsevier in Radiation Measurements
- Vol. 154, 106761
Open AccessOxGamma: A MATLAB based application for the analysis of gamma-ray spectra
- 15 July 2021
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 54 (38) , 385107
Site-selective characterisation of electron trapping centres in relation to chemistry, structural state and mineral phases present in single crystal alkali feldspars
Feldspars are ubiquitous natural dosimeters widely used in luminescence dating. Despite decades of research, the lattice defects as well as the mechanisms involved in luminescence production in feldspars remain poorly understood. The recently developed method of infrared photoluminescence (IRPL) excitation-emission spectroscopy has revealed the presence of two electron trapping centres emitting IRPL at 1.3 eV and 1.41 eV (IRPL 1.3 and IRPL 1.41 centres), and it enables detailed investigations into the ground and excited state energies of these centres. Here we make measurements of a range of single crystal alkali feldspars to understand the effects of feldspar chemical composition, crystal structure and framework disorder on the physical characteristics of IRPL 1.3 and IRPL 1.41 electron trapping centres. Measurements of our sample suite reveals IRPL and IR-radioluminescence (RL) emissions at 1.41 eV, 1.3 eV and, for the first time, at 1.2 eV. Our results show that whilst the IRPL 1.3 trapping centre is unaffected by the M site cation occupancy, the presence of IRPL 1.41 trapping centres seems to be linked to the presence of K + ions on M sites. However, no clear trends in IRPL and IR-RL emission energies and signal intensities with chemical composition of the samples were found. Exploring the effect of framework disorder on IRPL 1.3 and IRPL 1.41 emissions revealed no significant changes to IRPL and IR-RL emission energies or ground state energies of the trapping centres, suggesting that the corresponding defects are not located on bridging O ions. Variations in ground state energies across the whole sample suite range from 2.04 eV to 2.20 eV for the IRPL 1.3 centre and from 2.16 eV to 2.46 eV for the IRPL 1.41 centre. Variations in trap depth seem to be driven by other factors than sample chemistry, degree of Al 3+ disorder and number of phases present in a single crystal feldspar. Interestingly, the IR resonance peak is invariant between samples. Regarding the use of IRPL in luminescence dating, we show that optical resetting differs for the three different emissions, with the emission at ∼1.41 eV not being reset in some samples even after 18 h of solar bleaching.
- 15 July 2021
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 54 (38) , 385107
Site-selective characterisation of electron trapping centres in relation to chemistry, structural state and mineral phases present in single crystal alkali feldspars
Feldspars are ubiquitous natural dosimeters widely used in luminescence dating. Despite decades of research, the lattice defects as well as the mechanisms involved in luminescence production in feldspars remain poorly understood. The recently developed method of infrared photoluminescence (IRPL) excitation-emission spectroscopy has revealed the presence of two electron trapping centres emitting IRPL at 1.3 eV and 1.41 eV (IRPL 1.3 and IRPL 1.41 centres), and it enables detailed investigations into the ground and excited state energies of these centres. Here we make measurements of a range of single crystal alkali feldspars to understand the effects of feldspar chemical composition, crystal structure and framework disorder on the physical characteristics of IRPL 1.3 and IRPL 1.41 electron trapping centres. Measurements of our sample suite reveals IRPL and IR-radioluminescence (RL) emissions at 1.41 eV, 1.3 eV and, for the first time, at 1.2 eV. Our results show that whilst the IRPL 1.3 trapping centre is unaffected by the M site cation occupancy, the presence of IRPL 1.41 trapping centres seems to be linked to the presence of K + ions on M sites. However, no clear trends in IRPL and IR-RL emission energies and signal intensities with chemical composition of the samples were found. Exploring the effect of framework disorder on IRPL 1.3 and IRPL 1.41 emissions revealed no significant changes to IRPL and IR-RL emission energies or ground state energies of the trapping centres, suggesting that the corresponding defects are not located on bridging O ions. Variations in ground state energies across the whole sample suite range from 2.04 eV to 2.20 eV for the IRPL 1.3 centre and from 2.16 eV to 2.46 eV for the IRPL 1.41 centre. Variations in trap depth seem to be driven by other factors than sample chemistry, degree of Al 3+ disorder and number of phases present in a single crystal feldspar. Interestingly, the IR resonance peak is invariant between samples. Regarding the use of IRPL in luminescence dating, we show that optical resetting differs for the three different emissions, with the emission at ∼1.41 eV not being reset in some samples even after 18 h of solar bleaching.
- 1 March 2021
- Published by Elsevier in Quaternary Geochronology
- Vol. 62
Sediment dating using Infrared Photoluminescence
- 1 March 2021
- Published by Elsevier in Quaternary Geochronology
- Vol. 62
Sediment dating using Infrared Photoluminescence
- Open Access
- 24 September 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-14
Site-selective mapping of metastable states using electron-beam induced luminescence microscopy
Metastable states created by electron or hole capture in crystal defects are widely used in dosimetry and photonic applications. Feldspar, the most abundant mineral in the Earth’s crust (> 50%), generates metastable states with lifetimes of millions of years upon exposure to ionizing radiation. Although feldspar is widely used in dosimetry and geochronometry, the creation of metastable states and charge transfer across them is poorly understood. Understanding such phenomena requires next-generation methods based on high-resolution, site-selective probing of the metastable states. Recent studies using site-selective techniques such as photoluminescence (PL), and radioluminescence (RL) at 7 K have revealed that feldspar exhibits two near-infrared (NIR) emission bands peaking at 880 nm and 955 nm, which are believed to arise from the principal electron-trapping states. Here, we map for the first time the electron-trapping states in potassium-rich feldspar using spectrally-resolved cathodoluminescence microscopy at a spatial resolution of ~ 6 to 22 µm. Each pixel probed by a scanning electron microscope provides us a cathodoluminescence spectrum (SEM-CL) in the range 600–1000 nm, and elemental data from energy-dispersive x-ray (EDX) spectroscopy. We conclude that the two NIR emissions are spatially variable and, therefore, originate from different sites. This conclusion contradicts the existing model that the two emissions arise from two different excited states of a principal trap. Moreover, we are able to link the individual NIR emission peaks with the geochemical variations (K, Na and Fe concentration), and propose a model that explains the quenching of the NIR emission by Fe4+. Our study contributes to an improved understanding of charge storage in feldspathic minerals, with implications for developing sub-single grain (micrometer scale) measurement techniques in radiation dosimetry.
- 24 September 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-14
Open AccessSite-selective mapping of metastable states using electron-beam induced luminescence microscopy
Metastable states created by electron or hole capture in crystal defects are widely used in dosimetry and photonic applications. Feldspar, the most abundant mineral in the Earth’s crust (> 50%), generates metastable states with lifetimes of millions of years upon exposure to ionizing radiation. Although feldspar is widely used in dosimetry and geochronometry, the creation of metastable states and charge transfer across them is poorly understood. Understanding such phenomena requires next-generation methods based on high-resolution, site-selective probing of the metastable states. Recent studies using site-selective techniques such as photoluminescence (PL), and radioluminescence (RL) at 7 K have revealed that feldspar exhibits two near-infrared (NIR) emission bands peaking at 880 nm and 955 nm, which are believed to arise from the principal electron-trapping states. Here, we map for the first time the electron-trapping states in potassium-rich feldspar using spectrally-resolved cathodoluminescence microscopy at a spatial resolution of ~ 6 to 22 µm. Each pixel probed by a scanning electron microscope provides us a cathodoluminescence spectrum (SEM-CL) in the range 600–1000 nm, and elemental data from energy-dispersive x-ray (EDX) spectroscopy. We conclude that the two NIR emissions are spatially variable and, therefore, originate from different sites. This conclusion contradicts the existing model that the two emissions arise from two different excited states of a principal trap. Moreover, we are able to link the individual NIR emission peaks with the geochemical variations (K, Na and Fe concentration), and propose a model that explains the quenching of the NIR emission by Fe4+. Our study contributes to an improved understanding of charge storage in feldspathic minerals, with implications for developing sub-single grain (micrometer scale) measurement techniques in radiation dosimetry.
- Open Access
Site-selective mapping of metastable states using electron-beam induced luminescence microscopy
Metastable states created by electron or hole capture in crystal defects are widely used in dosimetry and photonic applications. Feldspar, the most abundant mineral in the Earth crust (>50%), generates metastable states with lifetimes of millions of years upon exposure to ionizing radiation. Although feldspar is widely used in dosimetry and geochronometry, the creation of metastable states and charge transfer across them is poorly understood. Understanding such phenomena requires next-generation methods based on high-resolution, site-selective probing of the metastable states. Recent studies using site-selective techniques such as photoluminescence (PL), and radioluminescence (RL) at 7 K have revealed that feldspar exhibits two near-infrared (NIR) emission bands peaking at 880 nm and 955 nm, which are believed to arise from the principal electron-trapping states. Here, we map for the first time the electron-trapping states in potassium-rich feldspar using spectrally-resolved cathodoluminescence microscopy at a spatial resolution of around 6 to 22 micrometer. Each pixel probed by a scanning electron microscope provides us a cathodoluminescence spectrum (SEM-CL) in the range 600-1000 nm, and elemental data from energy-dispersive x-ray (EDX) spectroscopy. We conclude that the two NIR emissions are spatially variable and, therefore, originate from different sites. This conclusion contradicts the existing model that the two emissions arise from two different excited states of a principal trap. Moreover, we are able to link the individual NIR emission peaks with the geochemical variations (K, Na and Fe concentration), and propose a cluster model that explains the quenching of the NIR emission by Fe4+.
Open AccessSite-selective mapping of metastable states using electron-beam induced luminescence microscopy
Metastable states created by electron or hole capture in crystal defects are widely used in dosimetry and photonic applications. Feldspar, the most abundant mineral in the Earth crust (>50%), generates metastable states with lifetimes of millions of years upon exposure to ionizing radiation. Although feldspar is widely used in dosimetry and geochronometry, the creation of metastable states and charge transfer across them is poorly understood. Understanding such phenomena requires next-generation methods based on high-resolution, site-selective probing of the metastable states. Recent studies using site-selective techniques such as photoluminescence (PL), and radioluminescence (RL) at 7 K have revealed that feldspar exhibits two near-infrared (NIR) emission bands peaking at 880 nm and 955 nm, which are believed to arise from the principal electron-trapping states. Here, we map for the first time the electron-trapping states in potassium-rich feldspar using spectrally-resolved cathodoluminescence microscopy at a spatial resolution of around 6 to 22 micrometer. Each pixel probed by a scanning electron microscope provides us a cathodoluminescence spectrum (SEM-CL) in the range 600-1000 nm, and elemental data from energy-dispersive x-ray (EDX) spectroscopy. We conclude that the two NIR emissions are spatially variable and, therefore, originate from different sites. This conclusion contradicts the existing model that the two emissions arise from two different excited states of a principal trap. Moreover, we are able to link the individual NIR emission peaks with the geochemical variations (K, Na and Fe concentration), and propose a cluster model that explains the quenching of the NIR emission by Fe4+.