Rotimi Adedayo Ibikunle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rotimi Adedayo Ibikunle has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Adeniyi Olayanju
Landmark University
3 shared publications - Peter Pelumi Ikubanni
Bowen University
3 shared publications - Adekunle Akanni Adeleke
Department of Mechanical Engineering, Nile University of Nigeria, Abuja, Nigeria
2 shared publications B.O. Akinnuli
2 shared publications- Bamidele Ogunsemi
Innovative Manufacturing Research Group, School of Engineering and Engineering Technology, Federal University of Technology Akure, PMB 704, Akure, Ondo State, Nigeria
2 shared publications C.O Osueke
2 shared publications
Latest Publications
- Open Access
- 16 June 2022
- Published by Akademiai Kiado Zrt. in International Review of Applied Sciences and Engineering
- Vol. 13 (2) , 124-132
Estimation of coefficient of performance of thermoelectric cooler using a 30 W single-stage type
In this study, a single stage thermoelectric cooler (TER, of size: 21 × 14.2 × 13.5 cm) with thermoelectric module (TEM, of type inbc1-127. 05 with size 40 × 40 × 4.0 mm) and applied electrical power of 30 W and current of 2.5 A, was adopted to estimate the coefficient of performance (COP) of thermoelectric refrigerator (TER). The TER uses a fan to cool the heat exchange region of the TEM. The temperature of the fruit/vegetable samples used in this study was taken before and after cooling for a specific period. The temperatures at both the hot and cold sides of the TEM were also taken at every specific cooling period. The experimented TER can cool vegetable/fruit from about 27 to 5°C within 3 h. The aim of this study is to determine the COP of TER to ascertain the possible applications. The temperature gradient at the heat exchange section of TEM was used to estimate the average theoretical COP to be 0.99, the heat extracted from the cooling chamber and the power supplied was used to estimate the average practical cooling COP to be 0.52; which is within 0.4–0.7 standard COP for a single stage type of TER.
- 16 June 2022
- Published by Akademiai Kiado Zrt. in International Review of Applied Sciences and Engineering
- Vol. 13 (2) , 124-132
Open AccessEstimation of coefficient of performance of thermoelectric cooler using a 30 W single-stage type
In this study, a single stage thermoelectric cooler (TER, of size: 21 × 14.2 × 13.5 cm) with thermoelectric module (TEM, of type inbc1-127. 05 with size 40 × 40 × 4.0 mm) and applied electrical power of 30 W and current of 2.5 A, was adopted to estimate the coefficient of performance (COP) of thermoelectric refrigerator (TER). The TER uses a fan to cool the heat exchange region of the TEM. The temperature of the fruit/vegetable samples used in this study was taken before and after cooling for a specific period. The temperatures at both the hot and cold sides of the TEM were also taken at every specific cooling period. The experimented TER can cool vegetable/fruit from about 27 to 5°C within 3 h. The aim of this study is to determine the COP of TER to ascertain the possible applications. The temperature gradient at the heat exchange section of TEM was used to estimate the average theoretical COP to be 0.99, the heat extracted from the cooling chamber and the power supplied was used to estimate the average practical cooling COP to be 0.52; which is within 0.4–0.7 standard COP for a single stage type of TER.
- 22 April 2022
- Published by Springer Nature in Journal of Material Cycles and Waste Management
- Vol. 24 (4) , 1591-1602
Exploration and prediction of wet season municipal solid waste for power generation in Ilorin metropolis, Nigeria
The wet season municipal solid waste (MSW) was characterized on Lasoju/Eyenkorin dumpsite for May to August 2020. The aggregate of waste generated was estimated to be 135,882 tons, while the aggregate characterized was estimated to be 80,700 tons. There are thirty-two samples of 240 L (bin of MSW) per sample considered in this investigation. There are twenty-one waste components categorized altogether, with packaging box having the highest proportion of 10.04%, followed by food residue of 9.64%, nylon 9.51%, and leather with the least fraction (0.75%) of the weight basis. Experimental investigations were performed on fourteen combustible fractions of the waste to determine the moisture content, elemental contents, and high heating value. The laboratory analysis reveals that the average carbon content available is 55%, 7% hydrogen, 1.35% nitrogen, 0.44% sulphur, and 30% oxygen; the low heating value of the waste was determined to be 23 MJ/kg. About 672 tons of MSW were investigated for energy production to give an energy and power potentials of 4.2 GWh and 53 MW discretely. The estimated electrical power potential for the wet season MSW is capable of meeting about 59% of the power demand for the Ilorin metropolis.
- 22 April 2022
- Published by Springer Nature in Journal of Material Cycles and Waste Management
- Vol. 24 (4) , 1591-1602
Exploration and prediction of wet season municipal solid waste for power generation in Ilorin metropolis, Nigeria
The wet season municipal solid waste (MSW) was characterized on Lasoju/Eyenkorin dumpsite for May to August 2020. The aggregate of waste generated was estimated to be 135,882 tons, while the aggregate characterized was estimated to be 80,700 tons. There are thirty-two samples of 240 L (bin of MSW) per sample considered in this investigation. There are twenty-one waste components categorized altogether, with packaging box having the highest proportion of 10.04%, followed by food residue of 9.64%, nylon 9.51%, and leather with the least fraction (0.75%) of the weight basis. Experimental investigations were performed on fourteen combustible fractions of the waste to determine the moisture content, elemental contents, and high heating value. The laboratory analysis reveals that the average carbon content available is 55%, 7% hydrogen, 1.35% nitrogen, 0.44% sulphur, and 30% oxygen; the low heating value of the waste was determined to be 23 MJ/kg. About 672 tons of MSW were investigated for energy production to give an energy and power potentials of 4.2 GWh and 53 MW discretely. The estimated electrical power potential for the wet season MSW is capable of meeting about 59% of the power demand for the Ilorin metropolis.
- Open Access
- 21 October 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (21) , 11665
Development of a Software System for Selecting Steam Power Plant to Convert Municipal Solid Waste to Energy
A software system that enhances the selection of appropriate power plant capacity that will convert combustible municipal solid waste (MSW) into energy was developed. The aggregate of waste to be converted was determined and the corresponding heating value was established. The capacities of steam power plants’ components required for the conversion were determined, using thermodynamic mathematical models. An algorithm based on models used to determine the energy potential, the power potential of MSW, the capacities of the components of the steam power plant, were translated into computer soft code using Java programming language; saturated steam and superheated steam tables, together with the thermodynamic properties of the power plant required were incorporated into the soft code. About 584 tons of MSW having a heating value of 20 MJ/kg was the quantity of waste experimented for energy generation. This information was input into the software as data and was processed. Then, the software was able to predict 3245.54 MWh energy potential for the quantity of waste, and electrical power potential of 40.54 MW. The capacities of the steam power plant components that were predicted include 100.35 MW of boiler power, 40.54 MW of turbine power, and 59.80 MW of condenser power. The methodology adopted will make it easy for the managers in the waste-to-energy sector to appropriately select the suitable capacity of the required steam power plant that can convert any quantify of MSW at any geographical location, without going through the engineering calculation and stress or rigor involved in the plant capacity design. Moreover, the accuracy obtained for the software is greater than 99%.
- 21 October 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (21) , 11665
Open AccessDevelopment of a Software System for Selecting Steam Power Plant to Convert Municipal Solid Waste to Energy
A software system that enhances the selection of appropriate power plant capacity that will convert combustible municipal solid waste (MSW) into energy was developed. The aggregate of waste to be converted was determined and the corresponding heating value was established. The capacities of steam power plants’ components required for the conversion were determined, using thermodynamic mathematical models. An algorithm based on models used to determine the energy potential, the power potential of MSW, the capacities of the components of the steam power plant, were translated into computer soft code using Java programming language; saturated steam and superheated steam tables, together with the thermodynamic properties of the power plant required were incorporated into the soft code. About 584 tons of MSW having a heating value of 20 MJ/kg was the quantity of waste experimented for energy generation. This information was input into the software as data and was processed. Then, the software was able to predict 3245.54 MWh energy potential for the quantity of waste, and electrical power potential of 40.54 MW. The capacities of the steam power plant components that were predicted include 100.35 MW of boiler power, 40.54 MW of turbine power, and 59.80 MW of condenser power. The methodology adopted will make it easy for the managers in the waste-to-energy sector to appropriately select the suitable capacity of the required steam power plant that can convert any quantify of MSW at any geographical location, without going through the engineering calculation and stress or rigor involved in the plant capacity design. Moreover, the accuracy obtained for the software is greater than 99%.
- 1 March 2021
- Published by Springer Nature in Journal of Material Cycles and Waste Management
- Vol. 23 (3) , 1239-1257
Investigating municipal solid waste generation and management in Ilorin for possible integrated waste-management system
- 1 March 2021
- Published by Springer Nature in Journal of Material Cycles and Waste Management
- Vol. 23 (3) , 1239-1257
Investigating municipal solid waste generation and management in Ilorin for possible integrated waste-management system
- Open Access
- 1 December 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1378 (3)
Predicting the Quantity of Municipal Solid Waste Required for Power Generation Using Power Plant Design Parameters
In energy recovery technology, via municipal solid waste (MSW) as an energy resource; the capacity of the power plant required can be designed, if the potentials of the heat and electrical energy of the waste to be combusted has been established. Conversely, in this research, the amount of power potential of the waste required as fuel, is determined through the design for the capacity of the steam power plant that will utilize municipal solid waste as an energy resource. The capacity of the power plant is designed, using single reheat Rankine cycle. The pressure and temperature selected for the design of the boiler is 30 bar and 400 °C, the pressure at the reheat tube is 6 bar, and the pressure at the condenser is 0.032 bar. The heat supplied to the boiler is calculated to be 3639.2 kJ/kg, the total work-output of the turbine is 1451.4 kJ/kg and the heat rejected at the condenser is 2187.6 kJ/kg. The quantity of MSW required is predicted to be 418 MJ/kg based on the calorific value of 20 MJ/kg, and its heat energy and electrical power potentials is predicted to be 2.3 GWh and 29 MW respectively while the grid to power is 20 MW.
- 1 December 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1378 (3)
Open AccessPredicting the Quantity of Municipal Solid Waste Required for Power Generation Using Power Plant Design Parameters
In energy recovery technology, via municipal solid waste (MSW) as an energy resource; the capacity of the power plant required can be designed, if the potentials of the heat and electrical energy of the waste to be combusted has been established. Conversely, in this research, the amount of power potential of the waste required as fuel, is determined through the design for the capacity of the steam power plant that will utilize municipal solid waste as an energy resource. The capacity of the power plant is designed, using single reheat Rankine cycle. The pressure and temperature selected for the design of the boiler is 30 bar and 400 °C, the pressure at the reheat tube is 6 bar, and the pressure at the condenser is 0.032 bar. The heat supplied to the boiler is calculated to be 3639.2 kJ/kg, the total work-output of the turbine is 1451.4 kJ/kg and the heat rejected at the condenser is 2187.6 kJ/kg. The quantity of MSW required is predicted to be 418 MJ/kg based on the calorific value of 20 MJ/kg, and its heat energy and electrical power potentials is predicted to be 2.3 GWh and 29 MW respectively while the grid to power is 20 MW.
- Open Access
- 1 December 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1378 (2) , 022076
Fabrication and Evaluation of Screw-like Fish Pelletizer
Good and balanced meals are required for fish to stay healthy and the production of these meals requires some machines like pelletizer. This study therefore contributes to the improvement of existing models of this machine by designing, fabricating and evaluating the performance of a new pelletizer. After fabrication, 5 kg fish feed ingredients weight was processed for 2.5 minutes in the machine in quadruplicate. The average discharge efficiency, percentage loss due to residue ingredients and production rate for the machine are 92.25 %, 7.75 % and 110.7 kg/h, respectively. The results showed that an increase in drying days led to a corresponding increase in percentage moisture content removal with a similar reduction in the weight of the pelletized fish meal. This machine will be of great assistant to medium and small-scale aquaculture farmers, thereby reducing the need for foreign sources of fish feed in fish farming sector.
- 1 December 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1378 (2) , 022076
Open AccessFabrication and Evaluation of Screw-like Fish Pelletizer
Good and balanced meals are required for fish to stay healthy and the production of these meals requires some machines like pelletizer. This study therefore contributes to the improvement of existing models of this machine by designing, fabricating and evaluating the performance of a new pelletizer. After fabrication, 5 kg fish feed ingredients weight was processed for 2.5 minutes in the machine in quadruplicate. The average discharge efficiency, percentage loss due to residue ingredients and production rate for the machine are 92.25 %, 7.75 % and 110.7 kg/h, respectively. The results showed that an increase in drying days led to a corresponding increase in percentage moisture content removal with a similar reduction in the weight of the pelletized fish meal. This machine will be of great assistant to medium and small-scale aquaculture farmers, thereby reducing the need for foreign sources of fish feed in fish farming sector.
- Open Access
- 1 November 2019
- Published by Elsevier in Energy Reports
- Vol. 5, 126-135
Estimation of power generation from municipal solid wastes: A case Study of Ilorin metropolis, Nigeria
- 1 November 2019
- Published by Elsevier in Energy Reports
- Vol. 5, 126-135
Open AccessEstimation of power generation from municipal solid wastes: A case Study of Ilorin metropolis, Nigeria
- Open Access
- 1 August 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1299 (1) , 012003
Impact of Physical and Chemical Properties of Municipal Solid Waste on its Electrical Power Rating Potential
Waste-to-energy (WTE) management method, has been considered as the best option; because, it reduces the quantity of waste generated by about 71 %, and ensure energy recovery for efficient waste management. In this study, physical, chemical and the heating properties of the waste components, generated in Ilorin were determined. The heating value was modelled against the physicochemical properties of MSW components to ascertain their correlation. The electrical power rating potential of the MSW was determined using Dulong’s model. The regression model developed on the correlation analysis was used to predict the effect of the physicochemical properties on the heating value and the power generation potential. It was concluded that 1 % increase in fixed carbon and volatile matter, total carbon and Nitrogen content, increases electrical power rating by 8 %, 37 %, 21 % and 10.80 % respectively; while 1 % increase in moisture and hydrogen content, reduces the electrical power rating by 11 % and 69.3 % respectively.
- 1 August 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1299 (1) , 012003
Open AccessImpact of Physical and Chemical Properties of Municipal Solid Waste on its Electrical Power Rating Potential
Waste-to-energy (WTE) management method, has been considered as the best option; because, it reduces the quantity of waste generated by about 71 %, and ensure energy recovery for efficient waste management. In this study, physical, chemical and the heating properties of the waste components, generated in Ilorin were determined. The heating value was modelled against the physicochemical properties of MSW components to ascertain their correlation. The electrical power rating potential of the MSW was determined using Dulong’s model. The regression model developed on the correlation analysis was used to predict the effect of the physicochemical properties on the heating value and the power generation potential. It was concluded that 1 % increase in fixed carbon and volatile matter, total carbon and Nitrogen content, increases electrical power rating by 8 %, 37 %, 21 % and 10.80 % respectively; while 1 % increase in moisture and hydrogen content, reduces the electrical power rating by 11 % and 69.3 % respectively.
- Open Access
- 1 December 2018
- Published by Elsevier in Data in Brief
- Vol. 21, 1496-1503
Dataset for the development of a diagnostic schedule for a defective LC-195V5 CNC milling machine at FUTA central workshop
- 1 December 2018
- Published by Elsevier in Data in Brief
- Vol. 21, 1496-1503
Open AccessDataset for the development of a diagnostic schedule for a defective LC-195V5 CNC milling machine at FUTA central workshop
- 4 August 2017
- Published by Springer Nature in MAPAN
- Vol. 32 (4) , 321-327
Generation of Calibration Charts for Horizontal Petroleum Storage Tanks Using Microsoft Excel
- 4 August 2017
- Published by Springer Nature in MAPAN
- Vol. 32 (4) , 321-327
Generation of Calibration Charts for Horizontal Petroleum Storage Tanks Using Microsoft Excel