Bing Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bing Chen has a total of 198 co-authors. Here are the top co-authors by number of shared publications:
- Nanyang Xu
Institute of Quantum Sensing College of Optical Science and Engineering Zhejiang University 310027 Hangzhou China
14 shared publications - Peng Qian
School of Physics and School of Microelectronic, Hefei University of Technology 1 , Hefei, Anhui 230009
10 shared publications Zhifei Yu
9 shared publications- Heng Shen
Shanxi University
8 shared publications Jianpei Geng
School of Physics Hefei University of Technology Hefei Anhui 230009 China
8 shared publications- Jing-Wei Fan
Department of Physics, Hefei University of Technology
8 shared publications
Latest Publications
- 12 November 2026
- Published by American Physical Society (APS) in Physical Review B
- Vol. 114 (28)
Topological dynamics of bound states in the continuum in bilayer metasurfaces
- 12 November 2026
- Published by American Physical Society (APS) in Physical Review B
- Vol. 114 (28)
Topological dynamics of bound states in the continuum in bilayer metasurfaces
- 20 July 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (3)
Three-dimensional high-uniformity magnetic field coils optimized by an IHO algorithm
Highly uniform-magnetic fields play a crucial role in a wide range of quantum systems. In this paper, an improved hippopotamus optimization (IHO) algorithm is introduced to optimize the structure of three-dimensional cylindrical uniform-magnetic field coils. Numerical simulations show that the IHO algorithm achieves higher solution accuracy with fewer iterations than conventional optimization algorithms. Within the proposed coil configuration, the IHO-optimized design can theoretically improve the magnetic field uniformity to the order of 10−10, resulting in improved magnetic field uniformity. We rapidly fabricated the uniform-magnetic field coil model using 3D printing and measured its performance. The measurements show that the magnetic field uniformity reaches the 10−5 level within a central region of approximately 1 cm while remaining on the order of 10−4 over a 2 cm region. These results indicate that the proposed IHO algorithm enables efficient optimization and yields coil designs with improved performance and structural simplicity, thereby offering a practical solution for quantum precision measurement and atomic spin control.
- 20 July 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (3)
Three-dimensional high-uniformity magnetic field coils optimized by an IHO algorithm
Highly uniform-magnetic fields play a crucial role in a wide range of quantum systems. In this paper, an improved hippopotamus optimization (IHO) algorithm is introduced to optimize the structure of three-dimensional cylindrical uniform-magnetic field coils. Numerical simulations show that the IHO algorithm achieves higher solution accuracy with fewer iterations than conventional optimization algorithms. Within the proposed coil configuration, the IHO-optimized design can theoretically improve the magnetic field uniformity to the order of 10−10, resulting in improved magnetic field uniformity. We rapidly fabricated the uniform-magnetic field coil model using 3D printing and measured its performance. The measurements show that the magnetic field uniformity reaches the 10−5 level within a central region of approximately 1 cm while remaining on the order of 10−4 over a 2 cm region. These results indicate that the proposed IHO algorithm enables efficient optimization and yields coil designs with improved performance and structural simplicity, thereby offering a practical solution for quantum precision measurement and atomic spin control.
- 20 July 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (3)
Diamond current sensor integrated with a magnetic flux concentrator
Low-frequency weak-current measurements are essential for applications such as nanoscale electronic characterization, biological ionic-current sensing, and battery leakage monitoring. While magnetometry with nitrogen-vacancy (NV) centers in diamond has been widely applied to high-current sensing, its use for ultra-weak-current detection remains relatively unexplored. Here, we demonstrate a room-temperature current sensor by integrating an NV-diamond magnetometry with a ring-shaped magnetic flux concentrator. Owing to the high permeability of the magnetic material and geometry-induced flux concentration, magnetic fields generated by ultra-weak currents are efficiently collected and enhanced at the sensor location. We achieve a current sensitivity of 0.39 nA/Hz, normalized to a single coil turn, and observe a linear transfer response with measurement deviations remaining below 3% across the tested current amplitudes and frequencies. These results provide a viable approach for extending NV-based sensing to low-frequency, ultra-weak-current regimes and offer a scalable platform for weak-signal detection in practical applications.
- 20 July 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (3)
Diamond current sensor integrated with a magnetic flux concentrator
Low-frequency weak-current measurements are essential for applications such as nanoscale electronic characterization, biological ionic-current sensing, and battery leakage monitoring. While magnetometry with nitrogen-vacancy (NV) centers in diamond has been widely applied to high-current sensing, its use for ultra-weak-current detection remains relatively unexplored. Here, we demonstrate a room-temperature current sensor by integrating an NV-diamond magnetometry with a ring-shaped magnetic flux concentrator. Owing to the high permeability of the magnetic material and geometry-induced flux concentration, magnetic fields generated by ultra-weak currents are efficiently collected and enhanced at the sensor location. We achieve a current sensitivity of 0.39 nA/Hz, normalized to a single coil turn, and observe a linear transfer response with measurement deviations remaining below 3% across the tested current amplitudes and frequencies. These results provide a viable approach for extending NV-based sensing to low-frequency, ultra-weak-current regimes and offer a scalable platform for weak-signal detection in practical applications.
- 5 December 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (25) , 52698-52713
High-Q quasi-bound states in the continuum in dimer dielectric resonators
Bound states in the continuum (BICs) offer an exceptional platform for wave trapping. Quasi-BICs in an isolated dielectric resonator with high quality factors (Q-factors) can be realized through leveraging avoided crossing between two modes due to strong coupling arising from destructive interference. In this work, we present a general strategy for constructing quasi-BICs in dimer dielectric resonators, achieving Q-factors that are enhanced by two to tens of times compared to quasi-BICs in a single dielectric resonator. Starting from a single dielectric structure supporting quasi-BICs, we optimize the Q-factors of supercavity modes by introducing an air gap within the single structure and systematically varying several structural dimensions of the dimer configuration. Multipole decomposition indicates that the enhancement in Q-factors originates from the suppression of multiple radiation channels. Moreover, we demonstrate that the design approach is universal via investigating high-Q quasi-BICs in both one-dimensional (1D) dimer rectangular nanowires (NWs) for transverse electric (TE) and transverse magnetic (TM) polarizations and three-dimensional (3D) dimer cuboids. Additionally, we explore the potential for further increasing the Q-factors of quasi-BICs using a trimer-resonator system. This work provides a rational framework for designing ultrahigh-Q resonances based on dimer or trimer dielectric resonators, with promising applications for enhancing light-matter interactions.
- 5 December 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (25) , 52698-52713
High-Q quasi-bound states in the continuum in dimer dielectric resonators
Bound states in the continuum (BICs) offer an exceptional platform for wave trapping. Quasi-BICs in an isolated dielectric resonator with high quality factors (Q-factors) can be realized through leveraging avoided crossing between two modes due to strong coupling arising from destructive interference. In this work, we present a general strategy for constructing quasi-BICs in dimer dielectric resonators, achieving Q-factors that are enhanced by two to tens of times compared to quasi-BICs in a single dielectric resonator. Starting from a single dielectric structure supporting quasi-BICs, we optimize the Q-factors of supercavity modes by introducing an air gap within the single structure and systematically varying several structural dimensions of the dimer configuration. Multipole decomposition indicates that the enhancement in Q-factors originates from the suppression of multiple radiation channels. Moreover, we demonstrate that the design approach is universal via investigating high-Q quasi-BICs in both one-dimensional (1D) dimer rectangular nanowires (NWs) for transverse electric (TE) and transverse magnetic (TM) polarizations and three-dimensional (3D) dimer cuboids. Additionally, we explore the potential for further increasing the Q-factors of quasi-BICs using a trimer-resonator system. This work provides a rational framework for designing ultrahigh-Q resonances based on dimer or trimer dielectric resonators, with promising applications for enhancing light-matter interactions.
- Open Access
- 1 November 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (11)
Multimode vector beam synthesis and rapid modulation via interferometric methods
Optical interference techniques are widely regarded as an effective approach for generating vector beams. In this paper, we theoretically simulate the generation of multimode vector beams through the vortex beams interference. Then, in the experiment, we employ a Mach–Zehnder interferometer configuration to coherently generate both vector beams and vector vortex beams by combining two circularly polarized vortex beams with opposite orbital angular momentum. Furthermore, by investigating the relationship between the polarization distribution of the vector beams and the phase difference of the interferometer’s two arms, we have achieved precise phase control and rapid modulation for generating vector beams. This has enabled the efficient generation of vector beams with various polarization states. Our experimental setup is compact and easy to operate, enabling the generation and rapid modulation of multimode vector beams, as well as the verification of the topological charge of vortex beams.
- 1 November 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (11)
Open AccessMultimode vector beam synthesis and rapid modulation via interferometric methods
Optical interference techniques are widely regarded as an effective approach for generating vector beams. In this paper, we theoretically simulate the generation of multimode vector beams through the vortex beams interference. Then, in the experiment, we employ a Mach–Zehnder interferometer configuration to coherently generate both vector beams and vector vortex beams by combining two circularly polarized vortex beams with opposite orbital angular momentum. Furthermore, by investigating the relationship between the polarization distribution of the vector beams and the phase difference of the interferometer’s two arms, we have achieved precise phase control and rapid modulation for generating vector beams. This has enabled the efficient generation of vector beams with various polarization states. Our experimental setup is compact and easy to operate, enabling the generation and rapid modulation of multimode vector beams, as well as the verification of the topological charge of vortex beams.
- 30 September 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (41) , 15031-15039
Off-Axis Magnetic Sensing via Dissipative Spin Dynamics Probed by Time-Resolved Fluorescence in Diamond
Magnetic field sensing with a nitrogen-vacancy (NV) center in diamond typically relies on coherent spin manipulation, which is susceptible to spin dephasing noise. Here, we demonstrate an alternative protocol that exploits dissipative spin dynamics, probed through time-resolved fluorescence, to extract off-axis magnetic field information without relying on spin coherence. The approach operates under continuous optical excitation and leverages spin-dependent transition channels to encode both the strength and orientation of the magnetic field into the fluorescence dynamics. Numerical simulations incorporating Gaussian magnetic noise confirm that the protocol remains robust against spin dephasing, maintaining a stable estimation performance even under short coherence times. We further develop a general parameter estimation framework based on photoluminescence trajectories, enabling off-axis field reconstruction from experimental measurements. The method is experimentally validated and may be adapted to other fluorescence-based spin defect platforms including silicon carbide and hexagonal boron nitride.
- 30 September 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (41) , 15031-15039
Off-Axis Magnetic Sensing via Dissipative Spin Dynamics Probed by Time-Resolved Fluorescence in Diamond
Magnetic field sensing with a nitrogen-vacancy (NV) center in diamond typically relies on coherent spin manipulation, which is susceptible to spin dephasing noise. Here, we demonstrate an alternative protocol that exploits dissipative spin dynamics, probed through time-resolved fluorescence, to extract off-axis magnetic field information without relying on spin coherence. The approach operates under continuous optical excitation and leverages spin-dependent transition channels to encode both the strength and orientation of the magnetic field into the fluorescence dynamics. Numerical simulations incorporating Gaussian magnetic noise confirm that the protocol remains robust against spin dephasing, maintaining a stable estimation performance even under short coherence times. We further develop a general parameter estimation framework based on photoluminescence trajectories, enabling off-axis field reconstruction from experimental measurements. The method is experimentally validated and may be adapted to other fluorescence-based spin defect platforms including silicon carbide and hexagonal boron nitride.
- 5 August 2025
- Published by Wiley in Advanced Optical Materials
- Vol. 13 (26)
Enhancing Extremely Low‐Frequency Signal‐to‐Noise Ratio of Diamond Magnetometry via Nonlinear Response
Extremely low‐frequency (below 10 Hz) current‐induced magnetic field detection has significant applications in high‐voltage DC systems, lithium‐ion battery diagnostics, and industrial process monitoring. Nitrogen‐vacancy (NV) ensembles magnetometry typically employs flux concentrators to enhance magnetic detection sensitivity, but this enhancement comes at the cost of introducing more low‐frequency magnetic noise, such as the thermal magnetization noise of ferromagnetic materials, directly limiting their potential at low frequencies. Here, the enhancement of the signal‐to‐noise ratio (SNR) in extremely low‐frequency magnetic field detection within NV magnetometry, achieved via nonlinear response, is experimentally demonstrated. The approach enables the extension of the magnetic field detection bandwidth to the Hz range while simultaneously enhancing magnetic field sensitivity by using a magnetic flux concentrator. The magnetic field from the coil current, enhanced by the flux concentrator, drives NV ensembles into the nonlinear response region of the differential spectrum of the optically detected magnetic resonance (ODMR). Within this regime, nonlinear effects generate signal‐frequency mixing and 1/f noise suppression. By pre‐modulating the target signal at the driving frequency, its recovery through frequency mixing retains 1/f noise suppression, consequently enhancing SNR. For the 0.5 Hz signal, experimental results demonstrate up to a 2.6‐fold enhancement in SNR. This approach offers a new strategy for utilizing NV ensembles in extremely low‐frequency magnetic field detection.
- 5 August 2025
- Published by Wiley in Advanced Optical Materials
- Vol. 13 (26)
Enhancing Extremely Low‐Frequency Signal‐to‐Noise Ratio of Diamond Magnetometry via Nonlinear Response
Extremely low‐frequency (below 10 Hz) current‐induced magnetic field detection has significant applications in high‐voltage DC systems, lithium‐ion battery diagnostics, and industrial process monitoring. Nitrogen‐vacancy (NV) ensembles magnetometry typically employs flux concentrators to enhance magnetic detection sensitivity, but this enhancement comes at the cost of introducing more low‐frequency magnetic noise, such as the thermal magnetization noise of ferromagnetic materials, directly limiting their potential at low frequencies. Here, the enhancement of the signal‐to‐noise ratio (SNR) in extremely low‐frequency magnetic field detection within NV magnetometry, achieved via nonlinear response, is experimentally demonstrated. The approach enables the extension of the magnetic field detection bandwidth to the Hz range while simultaneously enhancing magnetic field sensitivity by using a magnetic flux concentrator. The magnetic field from the coil current, enhanced by the flux concentrator, drives NV ensembles into the nonlinear response region of the differential spectrum of the optically detected magnetic resonance (ODMR). Within this regime, nonlinear effects generate signal‐frequency mixing and 1/f noise suppression. By pre‐modulating the target signal at the driving frequency, its recovery through frequency mixing retains 1/f noise suppression, consequently enhancing SNR. For the 0.5 Hz signal, experimental results demonstrate up to a 2.6‐fold enhancement in SNR. This approach offers a new strategy for utilizing NV ensembles in extremely low‐frequency magnetic field detection.
- 17 June 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (26) , 10572-10578
Robust 1-μm-Resolution Magnetic Probe Enabled by Optical Trapping of Nanodiamonds on a Tapered Fiber
High-resolution magnetic field scanning is critical for investigating nanoscale spin systems and characterizing defects in microelectronic devices. We present a fabrication-free approach to create robust magnetic probes with 1-μm spatial resolution by synergizing the quantum magnetic sensitivity of nitrogen-vacancy (NV) centers in nanodiamonds with the enhanced photon efficiency of tapered fibers. Through gradient-force optical trapping, nanodiamonds are precisely positioned at the fiber tip, where van der Waals forces immobilize them without requiring micro-nanoprocessing. In addition to possessing high spatial resolution, the probe exhibits a magnetic sensitivity reaching . By demonstrating a magnetic field scan of crossed microwires, this method can be extended to measure tiny magnetic structures or microcircuits, leveraging the integrated photonic enhancement of tapered fibers for robust high signal-to-noise sensing.- 17 June 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (26) , 10572-10578
Robust 1-μm-Resolution Magnetic Probe Enabled by Optical Trapping of Nanodiamonds on a Tapered Fiber
High-resolution magnetic field scanning is critical for investigating nanoscale spin systems and characterizing defects in microelectronic devices. We present a fabrication-free approach to create robust magnetic probes with 1-μm spatial resolution by synergizing the quantum magnetic sensitivity of nitrogen-vacancy (NV) centers in nanodiamonds with the enhanced photon efficiency of tapered fibers. Through gradient-force optical trapping, nanodiamonds are precisely positioned at the fiber tip, where van der Waals forces immobilize them without requiring micro-nanoprocessing. In addition to possessing high spatial resolution, the probe exhibits a magnetic sensitivity reaching . By demonstrating a magnetic field scan of crossed microwires, this method can be extended to measure tiny magnetic structures or microcircuits, leveraging the integrated photonic enhancement of tapered fibers for robust high signal-to-noise sensing.- 16 June 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (24)
Doping optimization of charge state stability for shallow nitrogen-vacancy center ensembles in HPHT diamonds
Since nitrogen-vacancy (NV) centers in diamond have emerged as crucial quantum sensors in physics and biology, the massive preparation of high-quality and high-concentration shallow NV center samples has become urgent and demanding. As NV centers approach the surface and their concentration increases, charge state instability can degrade coherence and introduce additional noise. This problem is further complicated in high-pressure and high-temperature (HPHT) diamonds due to the presence of unclear impurities and inhomogeneous strain. Through optically detected magnetic resonance testing on various implanted samples, we analyzed the spin and charge state properties of shallow NV center ensembles. Our results reveal that the doping dose significantly influences the quantity of NV−, charge, and charge stability. Our findings indicate that over-implanting nitrogen as electron donors before starting graphitization helps stabilize the charge environment of the shallow NV center ensembles. By controlling the nitrogen ion implantation dose, we optimized charge state stability under photoionization and prepared high-quality NV center ensemble samples in HPHT diamonds at the optimal implantation dose range of 2×1013–8×1013 ions/cm2. This method, which relies solely on nitrogen ion implantation and annealing on HPHT diamond, significantly reduces the cost of sensor samples, greatly benefiting the promotion of quantum sensing.
- 16 June 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (24)
Doping optimization of charge state stability for shallow nitrogen-vacancy center ensembles in HPHT diamonds
Since nitrogen-vacancy (NV) centers in diamond have emerged as crucial quantum sensors in physics and biology, the massive preparation of high-quality and high-concentration shallow NV center samples has become urgent and demanding. As NV centers approach the surface and their concentration increases, charge state instability can degrade coherence and introduce additional noise. This problem is further complicated in high-pressure and high-temperature (HPHT) diamonds due to the presence of unclear impurities and inhomogeneous strain. Through optically detected magnetic resonance testing on various implanted samples, we analyzed the spin and charge state properties of shallow NV center ensembles. Our results reveal that the doping dose significantly influences the quantity of NV−, charge, and charge stability. Our findings indicate that over-implanting nitrogen as electron donors before starting graphitization helps stabilize the charge environment of the shallow NV center ensembles. By controlling the nitrogen ion implantation dose, we optimized charge state stability under photoionization and prepared high-quality NV center ensemble samples in HPHT diamonds at the optimal implantation dose range of 2×1013–8×1013 ions/cm2. This method, which relies solely on nitrogen ion implantation and annealing on HPHT diamond, significantly reduces the cost of sensor samples, greatly benefiting the promotion of quantum sensing.
- 13 June 2025
- Published by American Physical Society (APS) in Physical Review B
- Vol. 111 (22)
Singlet state mediated charge and spin dynamics in nitrogen-vacancy centers in diamond
- 13 June 2025
- Published by American Physical Society (APS) in Physical Review B
- Vol. 111 (22)
Singlet state mediated charge and spin dynamics in nitrogen-vacancy centers in diamond