Yong Geon Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yong Geon Park has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Hui Taek Kim
Department of Orthopaedic Surgery, College of Medicine, Pusan National University, Busan, Korea
3 shared publications - Jung Sub Lee
Pusan National University Hospital
2 shared publications - Tae Sik Goh
Department of Orthopaedic Surgery, Pusan National University Hospital, Busan, Republic of Korea
2 shared publications - Tae Young Ahn
Department of Orthopaedic Surgery, Bio-Medical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan 49241, Republic of Korea
2 shared publications - Chang Ho Jeon
Department of Radiology, Eunpyeong St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
1 shared publication - Dong Ho Lee
Department of Orthopaedic Surgery, Barun Hospital, Busan, Korea
1 shared publication
Latest Publications
- Open Access
- 17 March 2026
- Published by SAGE Publications in Global Spine Journal
- Vol. 16 (7) , 3379-3386
High-Speed Instance Segmentation for Endoscopic Spine Surgery: Multicenter Validation and Inference Speed Evaluation
Study Design: Retrospective Multicenter Cohort Study. Objectives: To develop and validate an AI-based high-speed multi-class instance segmentation system for lumbar spinal endoscopic surgery using multicenter surgical video data and to assess performance across hardware environments. Methods: Endoscopic videos from 112 patients at 5 hospitals (2020-2025) were analyzed. One frame per 300 frames was sampled, yielding 58,087 annotated images for 7 classes (instrument, fat, soft tissue, bone, nerve, disc, vessel). A Segment Anything Model (SAM)-assisted workflow improved annotation efficiency, followed by expert refinement. A YOLOv11-seg model was trained with a patient-level 4:1 split. Performance was evaluated using precision, recall, F1-score, mAP50, and mAP50-95, stratified by surgical approach. Inference speed was benchmarked across CPU (Intel i5/i7) and GPU (RTX 4080/5080) configurations. Results: In the biportal group, overall precision, recall, F1-score, and mAP50 were 0.975, 0.633, 0.768, and 0.629, respectively. The uniportal group demonstrated 0.659, 0.670, 0.664, and 0.682, respectively. Class-wise performance varied substantially by surgical approach: the instrument class showed exceptionally high mAP50 (0.949) in uniportal settings, whereas anatomical structures like vessels were detected with superior accuracy in biportal settings (mAP50 = 0.863). Benchmarking yielded 21.86-27.45 FPS with CPU-only, ∼92 FPS with RTX 4080, and ∼117 FPS with RTX 5080. Conclusions: This multicenter study highlights the potential of high-speed, multi-class instance segmentation in endoscopic spine surgery. Improving model robustness in visually degraded environments requires further research. Prioritizing high precision to prevent surgeon distraction, supported by rapid inference to maintain temporal continuity, is a practical direction for future surgical AI models.
- 17 March 2026
- Published by SAGE Publications in Global Spine Journal
- Vol. 16 (7) , 3379-3386
Open AccessHigh-Speed Instance Segmentation for Endoscopic Spine Surgery: Multicenter Validation and Inference Speed Evaluation
Study Design: Retrospective Multicenter Cohort Study. Objectives: To develop and validate an AI-based high-speed multi-class instance segmentation system for lumbar spinal endoscopic surgery using multicenter surgical video data and to assess performance across hardware environments. Methods: Endoscopic videos from 112 patients at 5 hospitals (2020-2025) were analyzed. One frame per 300 frames was sampled, yielding 58,087 annotated images for 7 classes (instrument, fat, soft tissue, bone, nerve, disc, vessel). A Segment Anything Model (SAM)-assisted workflow improved annotation efficiency, followed by expert refinement. A YOLOv11-seg model was trained with a patient-level 4:1 split. Performance was evaluated using precision, recall, F1-score, mAP50, and mAP50-95, stratified by surgical approach. Inference speed was benchmarked across CPU (Intel i5/i7) and GPU (RTX 4080/5080) configurations. Results: In the biportal group, overall precision, recall, F1-score, and mAP50 were 0.975, 0.633, 0.768, and 0.629, respectively. The uniportal group demonstrated 0.659, 0.670, 0.664, and 0.682, respectively. Class-wise performance varied substantially by surgical approach: the instrument class showed exceptionally high mAP50 (0.949) in uniportal settings, whereas anatomical structures like vessels were detected with superior accuracy in biportal settings (mAP50 = 0.863). Benchmarking yielded 21.86-27.45 FPS with CPU-only, ∼92 FPS with RTX 4080, and ∼117 FPS with RTX 5080. Conclusions: This multicenter study highlights the potential of high-speed, multi-class instance segmentation in endoscopic spine surgery. Improving model robustness in visually degraded environments requires further research. Prioritizing high precision to prevent surgeon distraction, supported by rapid inference to maintain temporal continuity, is a practical direction for future surgical AI models.
- Open Access
- 1 January 2023
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 15 (2) , 249-256
Relationships between Clinical Status and Gait Parameters in Ankylosing Spondylitis
Park YG, et al. Clin Orthop Surg. 2023 Jan;15:e6. https://doi.org/10.4055/cios22112
- 1 January 2023
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 15 (2) , 249-256
Open AccessRelationships between Clinical Status and Gait Parameters in Ankylosing Spondylitis
Park YG, et al. Clin Orthop Surg. 2023 Jan;15:e6. https://doi.org/10.4055/cios22112
- Open Access
- 1 January 2022
- Published by The Korean Orthopaedic Association in Journal of the Korean Orthopaedic Association
- Vol. 57 (3) , 183-190
Pediatric Hip Disease (II): Developmental Dysplasia of the Hip – Treatment of Residual Dysplasia
- 1 January 2022
- Published by The Korean Orthopaedic Association in Journal of the Korean Orthopaedic Association
- Vol. 57 (3) , 183-190
Open AccessPediatric Hip Disease (II): Developmental Dysplasia of the Hip – Treatment of Residual Dysplasia
- Open Access
- 1 January 2020
- Published by The Korean Orthopaedic Association in Journal of the Korean Orthopaedic Association
- Vol. 55 (5) , 359-365
Pediatric Hip Disease (I): Diagnosis and Treatment of Developmental Dysplasia of the Hip
김휘택, et al. J Korean Orthop Assoc. 2020 Oct;55(5):359-365. https://doi.org/10.4055/jkoa.2020.55.5.359
- 1 January 2020
- Published by The Korean Orthopaedic Association in Journal of the Korean Orthopaedic Association
- Vol. 55 (5) , 359-365
Open AccessPediatric Hip Disease (I): Diagnosis and Treatment of Developmental Dysplasia of the Hip
김휘택, et al. J Korean Orthop Assoc. 2020 Oct;55(5):359-365. https://doi.org/10.4055/jkoa.2020.55.5.359
- Open Access
- 1 January 2020
- Published by The Korean Orthopaedic Association in Journal of the Korean Orthopaedic Association
- Vol. 55 (1)
Arthroscopic Full-Thickness Rotator Cuff Repair in Elderly Patients
- 1 January 2020
- Published by The Korean Orthopaedic Association in Journal of the Korean Orthopaedic Association
- Vol. 55 (1)
Open AccessArthroscopic Full-Thickness Rotator Cuff Repair in Elderly Patients
- Open Access
- 1 January 2019
- Published by The Korean Orthopaedic Trauma Association in Journal of the Korean Fracture Society
- Vol. 32 (1) , 56-60
Bilateral Gluteal Necrosis and Deep Infection after Transarterial Embolization for Pelvic Ring Injury in Patient with Hemodynamic Instability: A Case Report
Park SJ, et al. J Korean Fract Soc. 2019 Jan;32(1):56-60. https://doi.org/10.12671/jkfs.2019.32.1.56
- 1 January 2019
- Published by The Korean Orthopaedic Trauma Association in Journal of the Korean Fracture Society
- Vol. 32 (1) , 56-60
Open AccessBilateral Gluteal Necrosis and Deep Infection after Transarterial Embolization for Pelvic Ring Injury in Patient with Hemodynamic Instability: A Case Report
Park SJ, et al. J Korean Fract Soc. 2019 Jan;32(1):56-60. https://doi.org/10.12671/jkfs.2019.32.1.56
- 1 December 2018
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 8 (4) , e104
Double-Layered Lateral Meniscus Including a Ring-Shaped Accessory Meniscus
Case: We report the rare case of a double-layered lateral meniscus that was comprised of a normal meniscus and a ring-shaped accessory meniscus. An 11-year-old boy presented with left knee pain, and magnetic resonance imaging initially was interpreted as showing a horizontal meniscal tear. However, arthroscopic exploration revealed a double-layered meniscus. A superior accessory meniscus was fused with the inferior normal meniscus at the posterior horn and had more mobility compared with the normal meniscus. The symptoms improved substantially after resection of the superior accessory meniscus. The patient returned to sports at 4 months postoperatively; at 15 months postoperatively, radiographs demonstrated no evidence of degenerative changes. Conclusion: A double-layered lateral meniscus that includes a ring-shaped accessory meniscus is a rare abnormality that can be corrected arthroscopically by resection of the accessory meniscus.
- 1 December 2018
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 8 (4) , e104
Double-Layered Lateral Meniscus Including a Ring-Shaped Accessory Meniscus
Case: We report the rare case of a double-layered lateral meniscus that was comprised of a normal meniscus and a ring-shaped accessory meniscus. An 11-year-old boy presented with left knee pain, and magnetic resonance imaging initially was interpreted as showing a horizontal meniscal tear. However, arthroscopic exploration revealed a double-layered meniscus. A superior accessory meniscus was fused with the inferior normal meniscus at the posterior horn and had more mobility compared with the normal meniscus. The symptoms improved substantially after resection of the superior accessory meniscus. The patient returned to sports at 4 months postoperatively; at 15 months postoperatively, radiographs demonstrated no evidence of degenerative changes. Conclusion: A double-layered lateral meniscus that includes a ring-shaped accessory meniscus is a rare abnormality that can be corrected arthroscopically by resection of the accessory meniscus.