Shubham Gupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shubham Gupta has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Hannes Luc Röst
Donnelly Centre for Cellular and Biomolecular Research, University of Toronto, Toronto, Ontario, Canada
8 shared publications - Justin Cyril Sing
University of Toronto
3 shared publications - Arshia Mahmoodi
University of Toronto
1 shared publication - Binwu Ying
Department of Laboratory Medicine, Clinical Laboratory Medicine Research Center, West China Hospital Sichuan University, Sichuan Clinical Research Center for Laboratory Medicine Sichuan P. R. China
1 shared publication George Rosenberger
Department of Systems Biology, Columbia University, New York, New York 10032, United States
1 shared publicationHannes Röst
Donnelly Center for Biomolecular Research, University of Toronto, Toronto, Ontario ON M5S 3E1, Canada
1 shared publication
Latest Publications
- Open Access
STRIDE: Signal Transfer and Aligned Ion-Peak Discrimination for Peptidoform Evidence for Consistent Quantification of Site-Localized Post-Translational Modifications in Large-Scale DIA-MS
Data-independent acquisition (DIA) mass spectrometry has emerged as a powerful method for comprehensive post-translational modification profiling in proteomics, but faces challenges in consistently assigning peptidoforms to the same chromatographic peaks across multiple samples. This study introduces STRIDE to address this challenge by implementing dynamic programming alignment and propagating unique ion signature signals across runs. We benchmarked STRIDE using a synthetic phosphopeptide dilution series dataset, demonstrating an 11.3-fold reduction in false-negative rate compared to DIA-NN, from 68% with DIA-NN to 6% with STRIDE at 5% false-positive rate when requiring both correct site-localization and correct peak assignment. STRIDE also improved over the base OpenSWATH (IPF), reducing the false-negative rate from 14% to 6% for correct peak assignment. When applied to a phospho-enriched U2OS nocodazole dataset, our approach reduced missing values from 38.6% to 15.2% in a representative quantification matrix, increased highly reproducible phosphopeptide detections from 7,698 to 12,510 in nocodazole-treated samples, and identified 5,431 differentially abundant phosphopeptides compared to 2,588 with DIA-NN. This increased the number of enriched pathways recovered from differential phosphopeptide analysis, including pathways related to mitotic arrest, microtubule organization, chromatin regulation, RNA processing and kinase signalling. Lastly, we analyzed acetyllysine and glycopeptide-enriched DIA datasets, where STRIDE improved complete replicate detection, reduced missing quantification values, and increased site-specific glycan reproducibility. Together, these results demonstrate that STRIDE improves peptidoform proteomics through reduced false-negative rates, consistent peak assignment, and more complete quantification across runs.
Open AccessSTRIDE: Signal Transfer and Aligned Ion-Peak Discrimination for Peptidoform Evidence for Consistent Quantification of Site-Localized Post-Translational Modifications in Large-Scale DIA-MS
Data-independent acquisition (DIA) mass spectrometry has emerged as a powerful method for comprehensive post-translational modification profiling in proteomics, but faces challenges in consistently assigning peptidoforms to the same chromatographic peaks across multiple samples. This study introduces STRIDE to address this challenge by implementing dynamic programming alignment and propagating unique ion signature signals across runs. We benchmarked STRIDE using a synthetic phosphopeptide dilution series dataset, demonstrating an 11.3-fold reduction in false-negative rate compared to DIA-NN, from 68% with DIA-NN to 6% with STRIDE at 5% false-positive rate when requiring both correct site-localization and correct peak assignment. STRIDE also improved over the base OpenSWATH (IPF), reducing the false-negative rate from 14% to 6% for correct peak assignment. When applied to a phospho-enriched U2OS nocodazole dataset, our approach reduced missing values from 38.6% to 15.2% in a representative quantification matrix, increased highly reproducible phosphopeptide detections from 7,698 to 12,510 in nocodazole-treated samples, and identified 5,431 differentially abundant phosphopeptides compared to 2,588 with DIA-NN. This increased the number of enriched pathways recovered from differential phosphopeptide analysis, including pathways related to mitotic arrest, microtubule organization, chromatin regulation, RNA processing and kinase signalling. Lastly, we analyzed acetyllysine and glycopeptide-enriched DIA datasets, where STRIDE improved complete replicate detection, reduced missing quantification values, and increased site-specific glycan reproducibility. Together, these results demonstrate that STRIDE improves peptidoform proteomics through reduced false-negative rates, consistent peak assignment, and more complete quantification across runs.
- Open Access
Scoring information integration with statistical quality control enhanced cross-run analysis of data-independent acquisition proteomics data
The peptide-centric strategy is widely applied in data-independent acquisition (DIA) proteomics to analyze multiplexed MS2 spectra. However, current software tools often rely on single-run data for peptide peak identification, leading to inconsistent quantification across heterogeneous datasets. Match-between-runs (MBR) algorithms address this by aligning peaks or elution profiles across runs post-analysis but they are often ad-hoc and lack statistical frameworks for controlling peak quality, resulting in false positives and reduced quantitative reproducibility. Here we present DreamDIAlignR, a cross-run peptide-centric tool that integrates peptide elution behavior across runs with a deep learning peak identifier and signal alignment algorithm for consistent peak picking and FDR-controlled scoring. DreamDIAlignR outperformed state-of-the-art MBR methods, identifying up to 25.6% more quantitatively changing proteins on a benchmark dataset and 38.5% more on a cancer dataset. Additionally, DreamDIAlignR establishes an improved methodology for performing MBR compatible with existing DIA analysis tools, thereby enhancing the overall quality of DIA analysis.
Open AccessScoring information integration with statistical quality control enhanced cross-run analysis of data-independent acquisition proteomics data
The peptide-centric strategy is widely applied in data-independent acquisition (DIA) proteomics to analyze multiplexed MS2 spectra. However, current software tools often rely on single-run data for peptide peak identification, leading to inconsistent quantification across heterogeneous datasets. Match-between-runs (MBR) algorithms address this by aligning peaks or elution profiles across runs post-analysis but they are often ad-hoc and lack statistical frameworks for controlling peak quality, resulting in false positives and reduced quantitative reproducibility. Here we present DreamDIAlignR, a cross-run peptide-centric tool that integrates peptide elution behavior across runs with a deep learning peak identifier and signal alignment algorithm for consistent peak picking and FDR-controlled scoring. DreamDIAlignR outperformed state-of-the-art MBR methods, identifying up to 25.6% more quantitatively changing proteins on a benchmark dataset and 38.5% more on a cancer dataset. Additionally, DreamDIAlignR establishes an improved methodology for performing MBR compatible with existing DIA analysis tools, thereby enhancing the overall quality of DIA analysis.
- Open Access
- 30 October 2023
- Published by Springer Nature in Communications Biology
- Vol. 6 (1) , 1-12
Achieving quantitative reproducibility in label-free multisite DIA experiments through multirun alignment
DIA is a mainstream method for quantitative proteomics, but consistent quantification across multiple LC-MS/MS instruments remains a bottleneck in parallelizing data acquisition. One reason for this inconsistency and missing quantification is the retention time shift which current software does not adequately address for runs from multiple sites. We present multirun chromatogram alignment strategies to map peaks across columns, including the traditional reference-based Star method, and two novel approaches: MST and Progressive alignment. These reference-free strategies produce a quantitatively accurate data-matrix, even from heterogeneous multi-column studies. Progressive alignment also generates merged chromatograms from all runs which has not been previously achieved for LC-MS/MS data. First, we demonstrate the effectiveness of multirun alignment strategies on a gold-standard annotated dataset, resulting in a threefold reduction in quantitation error-rate compared to non-aligned DIA results. Subsequently, on a multi-species dataset that DIAlignR effectively controls the quantitative error rate, improves precision in protein measurements, and exhibits conservative peak alignment. We next show that the MST alignment reduces cross-site CV by 50% for highly abundant proteins when applied to a dataset from 11 different LC-MS/MS setups. Finally, the reanalysis of 949 plasma runs with multirun alignment revealed a more than 50% increase in insulin resistance (IR) and respiratory viral infection (RVI) proteins, identifying 11 and 13 proteins respectively, compared to prior analysis without it. The three strategies are implemented in our DIAlignR workflow (>2.3) and can be combined with linear, non-linear, or hybrid pairwise alignment.
- 30 October 2023
- Published by Springer Nature in Communications Biology
- Vol. 6 (1) , 1-12
Open AccessAchieving quantitative reproducibility in label-free multisite DIA experiments through multirun alignment
DIA is a mainstream method for quantitative proteomics, but consistent quantification across multiple LC-MS/MS instruments remains a bottleneck in parallelizing data acquisition. One reason for this inconsistency and missing quantification is the retention time shift which current software does not adequately address for runs from multiple sites. We present multirun chromatogram alignment strategies to map peaks across columns, including the traditional reference-based Star method, and two novel approaches: MST and Progressive alignment. These reference-free strategies produce a quantitatively accurate data-matrix, even from heterogeneous multi-column studies. Progressive alignment also generates merged chromatograms from all runs which has not been previously achieved for LC-MS/MS data. First, we demonstrate the effectiveness of multirun alignment strategies on a gold-standard annotated dataset, resulting in a threefold reduction in quantitation error-rate compared to non-aligned DIA results. Subsequently, on a multi-species dataset that DIAlignR effectively controls the quantitative error rate, improves precision in protein measurements, and exhibits conservative peak alignment. We next show that the MST alignment reduces cross-site CV by 50% for highly abundant proteins when applied to a dataset from 11 different LC-MS/MS setups. Finally, the reanalysis of 949 plasma runs with multirun alignment revealed a more than 50% increase in insulin resistance (IR) and respiratory viral infection (RVI) proteins, identifying 11 and 13 proteins respectively, compared to prior analysis without it. The three strategies are implemented in our DIAlignR workflow (>2.3) and can be combined with linear, non-linear, or hybrid pairwise alignment.
- Open Access
Signal Alignment Enables Analysis of DIA Proteomics Data from Multisite Experiments
DIA has become a mainstream method for quantitative proteomics, however consistent quantification across multiple LC-MS/MS instruments remains a bottleneck in parallelizing the data-acquisition. To produce a highly consistent and quantitatively accurate data matrix, we have developed DIAlignR which uses raw fragment-ion chromatograms for cross-run alignment. Its performance on a gold standard annotated dataset, demonstrates a threefold reduction in the identification error-rate when compared to standard non-aligned DIA results. A similar performance is achieved for a dataset of 229 runs acquired using 11 different LC-MS/MS setups. Finally, the analysis of 949 plasma runs with DIAlignR increased the number of statistically significant proteins by 43% and 62% for insulin resistant (IR) and respiratory viral infection (RVI), respectively compared to prior analysis without it. Hence, DIAlignR fills a gap in analyzing DIA runs acquired in-parallel using different LC-MS/MS instrumentation.
Open AccessSignal Alignment Enables Analysis of DIA Proteomics Data from Multisite Experiments
DIA has become a mainstream method for quantitative proteomics, however consistent quantification across multiple LC-MS/MS instruments remains a bottleneck in parallelizing the data-acquisition. To produce a highly consistent and quantitatively accurate data matrix, we have developed DIAlignR which uses raw fragment-ion chromatograms for cross-run alignment. Its performance on a gold standard annotated dataset, demonstrates a threefold reduction in the identification error-rate when compared to standard non-aligned DIA results. A similar performance is achieved for a dataset of 229 runs acquired using 11 different LC-MS/MS setups. Finally, the analysis of 949 plasma runs with DIAlignR increased the number of statistically significant proteins by 43% and 62% for insulin resistant (IR) and respiratory viral infection (RVI), respectively compared to prior analysis without it. Hence, DIAlignR fills a gap in analyzing DIA runs acquired in-parallel using different LC-MS/MS instrumentation.
- Open Access
- 21 June 2021
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 20 (7) , 3758-3766
DIAproteomics: A Multifunctional Data Analysis Pipeline for Data-Independent Acquisition Proteomics and Peptidomics
Data-independent acquisition (DIA) is becoming a leading analysis method in biomedical mass spectrometry. The main advantages include greater reproducibility and sensitivity and a greater dynamic range compared with data-dependent acquisition (DDA). However, the data analysis is complex and often requires expert knowledge when dealing with large-scale data sets. Here we present DIAproteomics, a multifunctional, automated, high-throughput pipeline implemented in the Nextflow workflow management system that allows one to easily process proteomics and peptidomics DIA data sets on diverse compute infrastructures. The central components are well-established tools such as the OpenSwathWorkflow for the DIA spectral library search and PyProphet for the false discovery rate assessment. In addition, it provides options to generate spectral libraries from existing DDA data and to carry out the retention time and chromatogram alignment. The output includes annotated tables and diagnostic visualizations from the statistical postprocessing and computation of fold-changes across pairwise conditions, predefined in an experimental design. DIAproteomics is well documented open-source software and is available under a permissive license to the scientific community at https://www.openms.de/diaproteomics/.
- 21 June 2021
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 20 (7) , 3758-3766
Open AccessDIAproteomics: A Multifunctional Data Analysis Pipeline for Data-Independent Acquisition Proteomics and Peptidomics
Data-independent acquisition (DIA) is becoming a leading analysis method in biomedical mass spectrometry. The main advantages include greater reproducibility and sensitivity and a greater dynamic range compared with data-dependent acquisition (DDA). However, the data analysis is complex and often requires expert knowledge when dealing with large-scale data sets. Here we present DIAproteomics, a multifunctional, automated, high-throughput pipeline implemented in the Nextflow workflow management system that allows one to easily process proteomics and peptidomics DIA data sets on diverse compute infrastructures. The central components are well-established tools such as the OpenSwathWorkflow for the DIA spectral library search and PyProphet for the false discovery rate assessment. In addition, it provides options to generate spectral libraries from existing DDA data and to carry out the retention time and chromatogram alignment. The output includes annotated tables and diagnostic visualizations from the statistical postprocessing and computation of fold-changes across pairwise conditions, predefined in an experimental design. DIAproteomics is well documented open-source software and is available under a permissive license to the scientific community at https://www.openms.de/diaproteomics/.
- Open Access
- 23 January 2020
- Published by Cold Spring Harbor Laboratory in bioRxiv
Automated Workflow For Peptide-level Quantitation From DIA/ SWATH-MS Data
Data Independent Acquisition (DIA) is a powerful method to acquire spectra from all ionized precursors of a sample. Considering the complexity of the highly multiplexed spectral data, sophisticated workflows have been developed to obtain peptides quantification. Here we describe an open-source and easy-to-use workflow to obtain a quantitative matrix from multiple DIA runs. This workflow requires as prior information an “assay library”, which contains the MS coordinates of peptides. It consists of OpenSWATH, pyProphet and DIAlignR software. For the ease of installation and to isolate operating system related dependency, docker-based containerization is utilized in this workflow.
- 23 January 2020
- Published by Cold Spring Harbor Laboratory in bioRxiv
Open AccessAutomated Workflow For Peptide-level Quantitation From DIA/ SWATH-MS Data
Data Independent Acquisition (DIA) is a powerful method to acquire spectra from all ionized precursors of a sample. Considering the complexity of the highly multiplexed spectral data, sophisticated workflows have been developed to obtain peptides quantification. Here we describe an open-source and easy-to-use workflow to obtain a quantitative matrix from multiple DIA runs. This workflow requires as prior information an “assay library”, which contains the MS coordinates of peptides. It consists of OpenSWATH, pyProphet and DIAlignR software. For the ease of installation and to isolate operating system related dependency, docker-based containerization is utilized in this workflow.
- Open Access
DrawAlignR: An interactive tool for across run chromatogram alignment visualization
Multi-run alignment is widely used in proteomics to establish analyte correspondence across runs. Generally alignment algorithms return a cumulative score, which may not be easily interpretable for each peptide. Here we present a novel tool, DrawAlignR, to visualize each chromatographic alignment for DIA/SWATH data. Furthermore, we have developed a novel C++ based implementation of raw chromatogram alignment which is 35 times faster than the previously published algorithm. This not only enables users to plot alignment interactively by DrawAlignR, but also allows other software platforms to use the algorithm. DrawAlignR is an open-source web application using R Shiny that can be hosted using the source-code available at https://github.com/Roestlab/DrawAlignR .
Open AccessDrawAlignR: An interactive tool for across run chromatogram alignment visualization
Multi-run alignment is widely used in proteomics to establish analyte correspondence across runs. Generally alignment algorithms return a cumulative score, which may not be easily interpretable for each peptide. Here we present a novel tool, DrawAlignR, to visualize each chromatographic alignment for DIA/SWATH data. Furthermore, we have developed a novel C++ based implementation of raw chromatogram alignment which is 35 times faster than the previously published algorithm. This not only enables users to plot alignment interactively by DrawAlignR, but also allows other software platforms to use the algorithm. DrawAlignR is an open-source web application using R Shiny that can be hosted using the source-code available at https://github.com/Roestlab/DrawAlignR .
- Open Access
LncRNA and predictive model to improve the diagnosis of clinically diagnosed pulmonary tuberculosis
Background: Clinically diagnosed pulmonary tuberculosis (PTB) patients lack Mycobacterium tuberculosis (MTB) microbiologic evidence, and misdiagnosis or delayed diagnosis often occurs as a consequence. We investigated the potential of lncRNAs and corresponding predictive models to diagnose these patients. Methods: We enrolled 1372 subjects, including clinically diagnosed PTB patients, non-TB disease controls and healthy controls, in three cohorts (Screening, Selection and Validation). Candidate lncRNAs differentially expressed in blood samples of the PTB and healthy control groups were identified by microarray and qRT-PCR in the Screening Cohort. Logistic regression models were developed using lncRNAs and/or electronic health records (EHRs) from clinically diagnosed PTB patients and non-TB disease controls in the Selection Cohort. These models were evaluated by AUC and decision curve analysis, and the optimal model was presented as a Web-based nomogram, which was evaluated in the Validation Cohort. The biological function of lncRNAs was interrogated using ELISA, lactate dehydrogenase release analysis and flow cytometry. Results: Three differentially expressed lncRNAs ( ENST00000497872, n333737, n335265 ) were identified. The optimal model (i.e., nomogram) incorporated these three lncRNAs and six EHR variables (age, hemoglobin, weight loss, low-grade fever, CT calcification and TB-IGRA). The nomogram showed an AUC of 0.89, sensitivity of 0.86 and specificity of 0.82 in the Validation Cohort, which demonstrated better discrimination and clinical net benefit than the EHR model. ENST00000497872 may regulate inflammatory cytokine production, cell death and apoptosis during MTB infection. Conclusion: LncRNAs and the user-friendly nomogram could facilitate the early identification of PTB cases among suspected patients with negative MTB microbiologic evidence. Key Messages: What is the key question?: Does integrating immune-related lncRNA signatures and electronic health records (EHRs) promote the early identification of PTB patients who are symptomatic but lack microbiologic evidence of Mycobacterium tuberculosis (MTB)? What is the bottom line?: We found three long non-coding RNAs (lncRNAs), i.e., ENST00000497872 , n 333737 and n335265 , were potential diagnostic biomarkers for clinically diagnosed PTB patients; and we further developed and validated a novel nomogram incorporating these three lncRNAs and six electronic health records (EHRs), which were readily obtainable even in a resource-constrained setting and achieved a c-statistic of 0.89, sensitivity of 0.86 and specificity of 0.82 in a separate validation cohort. Why read on?: This study focuses on the challenge of accurately diagnosing PTB patients with negative MTB microbiological evidence and serves as the first proof-of-concept that integrating lncRNA signatures and EHR data could be a more promising diagnostic approach for clinically diagnosed PTB patients. SUMMARY: This study developed and validated a novel nomogram that incorporated three lncRNAs and six EHR fields could be a useful predictive tool in identifying PTB patients who lack MTB microbiologic evidence.
Open AccessLncRNA and predictive model to improve the diagnosis of clinically diagnosed pulmonary tuberculosis
Background: Clinically diagnosed pulmonary tuberculosis (PTB) patients lack Mycobacterium tuberculosis (MTB) microbiologic evidence, and misdiagnosis or delayed diagnosis often occurs as a consequence. We investigated the potential of lncRNAs and corresponding predictive models to diagnose these patients. Methods: We enrolled 1372 subjects, including clinically diagnosed PTB patients, non-TB disease controls and healthy controls, in three cohorts (Screening, Selection and Validation). Candidate lncRNAs differentially expressed in blood samples of the PTB and healthy control groups were identified by microarray and qRT-PCR in the Screening Cohort. Logistic regression models were developed using lncRNAs and/or electronic health records (EHRs) from clinically diagnosed PTB patients and non-TB disease controls in the Selection Cohort. These models were evaluated by AUC and decision curve analysis, and the optimal model was presented as a Web-based nomogram, which was evaluated in the Validation Cohort. The biological function of lncRNAs was interrogated using ELISA, lactate dehydrogenase release analysis and flow cytometry. Results: Three differentially expressed lncRNAs ( ENST00000497872, n333737, n335265 ) were identified. The optimal model (i.e., nomogram) incorporated these three lncRNAs and six EHR variables (age, hemoglobin, weight loss, low-grade fever, CT calcification and TB-IGRA). The nomogram showed an AUC of 0.89, sensitivity of 0.86 and specificity of 0.82 in the Validation Cohort, which demonstrated better discrimination and clinical net benefit than the EHR model. ENST00000497872 may regulate inflammatory cytokine production, cell death and apoptosis during MTB infection. Conclusion: LncRNAs and the user-friendly nomogram could facilitate the early identification of PTB cases among suspected patients with negative MTB microbiologic evidence. Key Messages: What is the key question?: Does integrating immune-related lncRNA signatures and electronic health records (EHRs) promote the early identification of PTB patients who are symptomatic but lack microbiologic evidence of Mycobacterium tuberculosis (MTB)? What is the bottom line?: We found three long non-coding RNAs (lncRNAs), i.e., ENST00000497872 , n 333737 and n335265 , were potential diagnostic biomarkers for clinically diagnosed PTB patients; and we further developed and validated a novel nomogram incorporating these three lncRNAs and six electronic health records (EHRs), which were readily obtainable even in a resource-constrained setting and achieved a c-statistic of 0.89, sensitivity of 0.86 and specificity of 0.82 in a separate validation cohort. Why read on?: This study focuses on the challenge of accurately diagnosing PTB patients with negative MTB microbiological evidence and serves as the first proof-of-concept that integrating lncRNA signatures and EHR data could be a more promising diagnostic approach for clinically diagnosed PTB patients. SUMMARY: This study developed and validated a novel nomogram that incorporated three lncRNAs and six EHR fields could be a useful predictive tool in identifying PTB patients who lack MTB microbiologic evidence.
- Open Access
- 1 April 2019
- Published by Elsevier in Molecular & Cellular Proteomics
- Vol. 18 (4) , 806-817
DIAlignR Provides Precise Retention Time Alignment Across Distant Runs in DIA and Targeted Proteomics
- 1 April 2019
- Published by Elsevier in Molecular & Cellular Proteomics
- Vol. 18 (4) , 806-817
Open AccessDIAlignR Provides Precise Retention Time Alignment Across Distant Runs in DIA and Targeted Proteomics
- Open Access
DIAlignR provides precise retention time alignment across distant runs in DIA and targeted proteomics
SWATH-MS has been widely used for proteomics analysis given its high-throughput and reproducibility but ensuring consistent quantification of analytes across large-scale studies of heterogeneous samples such as human-plasma remains challenging. Heterogeneity in large-scale studies can be caused by large time intervals between data-acquisition, acquisition by different operators or instruments, intermittent repair or replacement of parts, such as the liquid chromatography column, all of which affect retention time (RT) reproducibility and successively performance of SWATH-MS data analysis. Here, we present a novel algorithm for retention time alignment of SWATH-MS data based on direct alignment of raw MS2 chromatograms using a hybrid dynamic programming approach. The algorithm does not impose a chronological order of elution and allows for alignment of elution-order swapped peaks. Furthermore, allowing RT-mapping in a certain window around coarse global fit makes it robust against noise. On a manually validated dataset, this strategy outperforms the current state-of-the-art approaches. In addition, on a real-world clinical data, our approach outperforms global alignment methods by mapping 98% of peaks compared to 67% cumulatively and DIAlignR can reduce alignment error up to 30-fold for extremely distant runs. The robustness of technical parameters used in this pairwise alignment strategy has also been demonstrated. The source code is released under the BSD license at https://github.com/Roestlab/DIAlignR . Abbreviations: AUC Area Under the Curve DIA Data-independent acquisition LC Liquid chromatography LOESS Local weighted regression RSE Residual Standard Error RT Retention time XIC Extracted ion chromatograms Data Availability: Raw chromatograms and features extracted by OpenSWATH are available on PeptideAtlas. Servername: ftp.peptideatlas.org Username: PASS01280 Password: KQ2592b
Open AccessDIAlignR provides precise retention time alignment across distant runs in DIA and targeted proteomics
SWATH-MS has been widely used for proteomics analysis given its high-throughput and reproducibility but ensuring consistent quantification of analytes across large-scale studies of heterogeneous samples such as human-plasma remains challenging. Heterogeneity in large-scale studies can be caused by large time intervals between data-acquisition, acquisition by different operators or instruments, intermittent repair or replacement of parts, such as the liquid chromatography column, all of which affect retention time (RT) reproducibility and successively performance of SWATH-MS data analysis. Here, we present a novel algorithm for retention time alignment of SWATH-MS data based on direct alignment of raw MS2 chromatograms using a hybrid dynamic programming approach. The algorithm does not impose a chronological order of elution and allows for alignment of elution-order swapped peaks. Furthermore, allowing RT-mapping in a certain window around coarse global fit makes it robust against noise. On a manually validated dataset, this strategy outperforms the current state-of-the-art approaches. In addition, on a real-world clinical data, our approach outperforms global alignment methods by mapping 98% of peaks compared to 67% cumulatively and DIAlignR can reduce alignment error up to 30-fold for extremely distant runs. The robustness of technical parameters used in this pairwise alignment strategy has also been demonstrated. The source code is released under the BSD license at https://github.com/Roestlab/DIAlignR . Abbreviations: AUC Area Under the Curve DIA Data-independent acquisition LC Liquid chromatography LOESS Local weighted regression RSE Residual Standard Error RT Retention time XIC Extracted ion chromatograms Data Availability: Raw chromatograms and features extracted by OpenSWATH are available on PeptideAtlas. Servername: ftp.peptideatlas.org Username: PASS01280 Password: KQ2592b