JHJack Harvie-Clark

Jack Harvie-Clark

*This is an algorithmically generated author record based on publicly available information.

Jack Harvie-Clark has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Room acoustic target values in offices: a global review

    by Virginia Tardini, Giulia Fratoni, Jack Harvie-Clark, Valtteri Hongisto

  • Assessing noise and overheating in dwellings: Aligning acoustic and thermal models for partially open windows

    by Jack Harvie-Clark, Gioia Fusaro, Luis Pereira, James Hill, James Healey

    Building regulations increasingly require balanced solutions for thermal comfort and acoustic performance, particularly for naturally ventilated dwellings. England’s Approved Document O (ADO) establishes noise thresholds for bedrooms using open windows for ventilation, allowing partially open windows (POW) rather than fully open ones to balance sound insulation with overheating mitigation. This study addresses the fundamental challenge of aligning acoustic and thermal modelling methodologies for POWs. Through field measurements at eight residential sites with diverse window configurations, we compared two assessment approaches: the theoretically-derived ‘Acoustic Open Area’ (AcOA) and the ventilation-based ‘Equivalent Area’ (EA). Statistical analysis revealed comparable accuracy between methods (standard deviations of 1.9 and 1.8 dB respectively), with no significant additional uncertainty when using EA instead of AcOA. Spectral analysis demonstrated that while measured sound insulation varies considerably with frequency, both methods effectively predict overall performance for typical environmental noise sources. This research establishes that EA – already used in thermal modelling – can reliably replace AcOA for acoustic assessments, significantly simplifying interdisciplinary coordination. These findings provide practical guidance for designers, engineers, and regulators developing integrated façade solutions that simultaneously address ventilation requirements and acoustic comfort.


  • Open Access

    Acoustics for Supportive and Healthy Buildings: Emerging Themes on Indoor Soundscape Research

    by Simone Torresin, Francesco Aletta, Francesco Babich, Ethan Bourdeau, Jack Harvie-Clark, Jian Kang, Lisa Lavia, Antonella Radicchi, Rossano Albatici

    The focus of the building industry and research is shifting from delivering satisfactory spaces to going beyond what is merely acceptable with a wave of new research and practice dedicated to exploring how the built environment can support task performance and enhance people’s health and well-being. The present study addresses the role of acoustics in this paradigm shift. Indoor soundscape research has recently emerged as an approach that brings a perceptual perspective on building and room acoustics in order to shape built environments that “sound good” according to building occupants’ preference and needs. This paper establishes an initial discussion over some of the open questions in this field of research that is still in an embryonic stage. A thematic analysis of structured interviews with a panel of experts offered a range of perspectives on the characterization, management, and design of indoor soundscapes and health-related outcomes. The discussion pointed out the importance of both perceptual and multisensory research and integrated participatory design practices to enable a holistic view regarding the complex building–user interrelations and the design of just cities. Soundscape methodologies tailored to the peculiarities of indoor soundscapes can help to measure and predict the human perceptual response to the acoustic stimuli in context, thus reducing the risk of mismatches between expected and real building experiences. This perceptual perspective is expected to widen the scientific evidence for the negative and positive impacts of the acoustic environment on human health, well-being, and quality of life. This will support prioritizing the role of acoustics in building design and challenge many current design practices that are based on a noise control approach.


  • Open Access

    Assessing noise with provisions for ventilation and overheating in dwellings

    by Jack Harvie-Clark, Anthony Chilton, Nick Conlan, David Trew

    In the design of residential developments, it has been common practice for façade sound insulation (to protect against outdoor noise) to be considered separately from the provisions for ventilation and for mitigating overheating. This fragmented approach has led to different designers making different, incompatible assumptions about the internal environmental quality conditions: the acoustic designer assumes that windows are closed to control external noise ingress, while the mechanical designer assumes that windows are open for ventilation or mitigating overheating. This leaves occupants with a choice between reasonable noise levels or thermal comfort, but not both. This problem is exacerbated by increased overheating risk in modern buildings and future climate scenarios. In response to this issue, the Association of Noise Consultants has produced the draft Acoustics Ventilation and Overheating Residential Design Guide – the ‘AVO Guide’. The AVO guide recommends an approach to acoustic assessment that takes regard of the interdependence of provisions for external noise ingress, ventilation and overheating. This paper describes the context, background and content of the AVO Guide. There are references to passive attenuated options for ventilative cooling to help designers avoid simply specifying mechanical cooling. Practical application: This paper is entirely focused on the practical application of the guidance in the Association of Noise Consultants’ Acoustics, Ventilation and Overheating Residential Design Guide. It describes the current practical problem that designers face, and the mistakes that are the common practice across the industry, of failing to integrate the design for noise with the ventilation strategy and provisions for overheating. It outlines how this can be achieved to enable better internal environmental quality conditions for occupants, supported by the current English Planning regime and professional good practice guidance available.


  • How loud is too loud? noise from domestic mechanical ventilation systems

    by Jack Harvie-Clark, Nick Conlan, Weigang Wei, Mark Siddall

    Noise from domestic ventilation systems is currently a little understood problem in the UK. Other European countries that have a longer history of using mechanical domestic ventilation systems have introduced noise limits for these systems. Without mandatory limits for noise in UK, noise is not a factor that is often considered during the design. However, noise can be a significant constraint to the use of ventilation systems. Research is reviewed from across Europe and North America which indicates residents turn off ventilation equipment that has objectionable noise. Without adequate ventilation in modern airtight dwellings, poor air quality can have a significantly adverse effect on the health of the occupants. There is a lack of evidence in the literature and performance standards for appropriate noise metrics and values that occupants find acceptable: this research is urgently required, and the steps to realise this are outlined; interim noise limits are proposed. Causes of excessive noise are found to originate due to problems during the design, procurement, installation, commissioning and operation of ventilation systems. A suitable metric is required along with regulatory control to ensure that residents are not forced to choose between intolerable noise or inadequate air quality.


  • Measurements of ultrasound from public address and voice alarm systems in public places

    by Beth Paxton, Jack Harvie-Clark, Max Albert

    Concerns have been raised about potential health effects of public exposure to ultrasound; however, there are few published surveys of measurements taken in public places. Results are presented of measurements taken in a selection of public places including train stations, shopping centres, galleries and museums, and the difficulties of taking measurements with conventional equipment are highlighted. Tones were identified in the 20 kHz third-octave band at 8 of the 14 locations tested; the characteristics of the tones are consistent with their source being Public Address or Voice Alarm systems. The measured results do not exceed existing interim guidelines for public exposure to ultrasound, and existing research suggests that no significant undesirable effects would be anticipated following exposure to ultrasound of this nature for short periods. The measured data may be reviewed against future public exposure guidelines which consider the variation in response across the population and between continuous and pulsed sources.