Xiaohui Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiaohui Lu has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Xiaofei Wang
Department of Environmental Science and Engineering, Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention, Fudan University, Shanghai 200433, China
10 shared publications Xiewen Ma
Department of Environmental Science and Engineering, Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention, Fudan University, Shanghai 200433, China
9 shared publicationsXinghua Jiang
Department of Environmental Science and Engineering, Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention, Fudan University, Shanghai 200433, China
9 shared publicationsGui Dai
Department of Environmental Science and Engineering, Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention, Fudan University, Shanghai 200433, China
8 shared publicationsLuoqiu Quan
Department of Environmental Science and Engineering, Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention, Fudan University, Shanghai 200433, China
8 shared publicationsQianqian Gao
Department of Environmental Science and Engineering, Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention, Fudan University, Shanghai 200433, China
8 shared publications
Latest Publications
- Open Access
- 22 June 2026
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 26 (12) , 8753-8764
Critical role of dust induced electrostatic coagulation in the evolution of aerosol size distributions in the atmosphere
Coagulation modifies the particle size distributions (PSD) of atmospheric aerosols, affecting their optical properties, cloud droplet activation, and gravitational deposition. While Coulomb forces may impact coagulation processes between charged aerosols, such as dust, most coagulation models neglect the effects of aerosol charge. Here, we address the lack of measurements of charge numbers carried by individual dust aerosol particles by developing a method to retrieve their joint size-charge distributions. By incorporating aerosol charge into the coagulation kernel, simulations in a dust-only scenario at typical environmental concentrations show that, on hourly timescales, electrostatic force leads to a reduction of up to ∼ 64 % in number concentration relative to Brownian coagulation. Moreover, electrostatic coagulation between dust and ambient sub-500 nm aerosols modifies the latter's PSD by ∼ 10 % compared with Brownian coagulation. These results strongly suggest that electrostatic coagulation should be considered in air quality models.
- 22 June 2026
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 26 (12) , 8753-8764
Open AccessCritical role of dust induced electrostatic coagulation in the evolution of aerosol size distributions in the atmosphere
Coagulation modifies the particle size distributions (PSD) of atmospheric aerosols, affecting their optical properties, cloud droplet activation, and gravitational deposition. While Coulomb forces may impact coagulation processes between charged aerosols, such as dust, most coagulation models neglect the effects of aerosol charge. Here, we address the lack of measurements of charge numbers carried by individual dust aerosol particles by developing a method to retrieve their joint size-charge distributions. By incorporating aerosol charge into the coagulation kernel, simulations in a dust-only scenario at typical environmental concentrations show that, on hourly timescales, electrostatic force leads to a reduction of up to ∼ 64 % in number concentration relative to Brownian coagulation. Moreover, electrostatic coagulation between dust and ambient sub-500 nm aerosols modifies the latter's PSD by ∼ 10 % compared with Brownian coagulation. These results strongly suggest that electrostatic coagulation should be considered in air quality models.
- Open Access
- 3 May 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-20
Response to Reviewer 2's comments
Coagulation modifies the particle size distributions (PSD) of atmospheric aerosols, affecting their optical properties, cloud droplet activation, and gravitational deposition. While Coulomb forces may impact coagulation processes between charged aerosols, such as dust, most coagulation models neglect the effects of aerosol charge. Here, we address the lack of single-particle charge measurements for dust aerosols by developing a method to retrieve their joint size-charge distributions. By incorporating aerosol charge into the coagulation kernel, simulations in a dust-only scenario at typical environmental concentrations show that, on hourly timescales, electrostatic force leads to a reduction of up to ~64 % in number concentration relative to Brownian coagulation. Moreover, electrostatic coagulation between dust and ambient sub-500 nm aerosols modifies the latter's PSD by ~10 % compared with Brownian coagulation. These results strongly suggest that electrostatic coagulation should be considered in air quality models.
- 3 May 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-20
Open AccessResponse to Reviewer 2's comments
Coagulation modifies the particle size distributions (PSD) of atmospheric aerosols, affecting their optical properties, cloud droplet activation, and gravitational deposition. While Coulomb forces may impact coagulation processes between charged aerosols, such as dust, most coagulation models neglect the effects of aerosol charge. Here, we address the lack of single-particle charge measurements for dust aerosols by developing a method to retrieve their joint size-charge distributions. By incorporating aerosol charge into the coagulation kernel, simulations in a dust-only scenario at typical environmental concentrations show that, on hourly timescales, electrostatic force leads to a reduction of up to ~64 % in number concentration relative to Brownian coagulation. Moreover, electrostatic coagulation between dust and ambient sub-500 nm aerosols modifies the latter's PSD by ~10 % compared with Brownian coagulation. These results strongly suggest that electrostatic coagulation should be considered in air quality models.
- Open Access
- 3 May 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-20
Comment on egusphere-2026-486
Coagulation modifies the particle size distributions (PSD) of atmospheric aerosols, affecting their optical properties, cloud droplet activation, and gravitational deposition. While Coulomb forces may impact coagulation processes between charged aerosols, such as dust, most coagulation models neglect the effects of aerosol charge. Here, we address the lack of single-particle charge measurements for dust aerosols by developing a method to retrieve their joint size-charge distributions. By incorporating aerosol charge into the coagulation kernel, simulations in a dust-only scenario at typical environmental concentrations show that, on hourly timescales, electrostatic force leads to a reduction of up to ~64 % in number concentration relative to Brownian coagulation. Moreover, electrostatic coagulation between dust and ambient sub-500 nm aerosols modifies the latter's PSD by ~10 % compared with Brownian coagulation. These results strongly suggest that electrostatic coagulation should be considered in air quality models.
- 3 May 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-20
Open AccessComment on egusphere-2026-486
Coagulation modifies the particle size distributions (PSD) of atmospheric aerosols, affecting their optical properties, cloud droplet activation, and gravitational deposition. While Coulomb forces may impact coagulation processes between charged aerosols, such as dust, most coagulation models neglect the effects of aerosol charge. Here, we address the lack of single-particle charge measurements for dust aerosols by developing a method to retrieve their joint size-charge distributions. By incorporating aerosol charge into the coagulation kernel, simulations in a dust-only scenario at typical environmental concentrations show that, on hourly timescales, electrostatic force leads to a reduction of up to ~64 % in number concentration relative to Brownian coagulation. Moreover, electrostatic coagulation between dust and ambient sub-500 nm aerosols modifies the latter's PSD by ~10 % compared with Brownian coagulation. These results strongly suggest that electrostatic coagulation should be considered in air quality models.
- Open Access
- 3 May 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-20
Response to Reviewer 1's comments
Coagulation modifies the particle size distributions (PSD) of atmospheric aerosols, affecting their optical properties, cloud droplet activation, and gravitational deposition. While Coulomb forces may impact coagulation processes between charged aerosols, such as dust, most coagulation models neglect the effects of aerosol charge. Here, we address the lack of single-particle charge measurements for dust aerosols by developing a method to retrieve their joint size-charge distributions. By incorporating aerosol charge into the coagulation kernel, simulations in a dust-only scenario at typical environmental concentrations show that, on hourly timescales, electrostatic force leads to a reduction of up to ~64 % in number concentration relative to Brownian coagulation. Moreover, electrostatic coagulation between dust and ambient sub-500 nm aerosols modifies the latter's PSD by ~10 % compared with Brownian coagulation. These results strongly suggest that electrostatic coagulation should be considered in air quality models.
- 3 May 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-20
Open AccessResponse to Reviewer 1's comments
Coagulation modifies the particle size distributions (PSD) of atmospheric aerosols, affecting their optical properties, cloud droplet activation, and gravitational deposition. While Coulomb forces may impact coagulation processes between charged aerosols, such as dust, most coagulation models neglect the effects of aerosol charge. Here, we address the lack of single-particle charge measurements for dust aerosols by developing a method to retrieve their joint size-charge distributions. By incorporating aerosol charge into the coagulation kernel, simulations in a dust-only scenario at typical environmental concentrations show that, on hourly timescales, electrostatic force leads to a reduction of up to ~64 % in number concentration relative to Brownian coagulation. Moreover, electrostatic coagulation between dust and ambient sub-500 nm aerosols modifies the latter's PSD by ~10 % compared with Brownian coagulation. These results strongly suggest that electrostatic coagulation should be considered in air quality models.
- Open Access
- 28 February 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-20
Comment on egusphere-2026-486
Coagulation modifies the particle size distributions (PSD) of atmospheric aerosols, affecting their optical properties, cloud droplet activation, and gravitational deposition. While Coulomb forces may impact coagulation processes between charged aerosols, such as dust, most coagulation models neglect the effects of aerosol charge. Here, we address the lack of single-particle charge measurements for dust aerosols by developing a method to retrieve their joint size-charge distributions. By incorporating aerosol charge into the coagulation kernel, simulations in a dust-only scenario at typical environmental concentrations show that, on hourly timescales, electrostatic force leads to a reduction of up to ~64 % in number concentration relative to Brownian coagulation. Moreover, electrostatic coagulation between dust and ambient sub-500 nm aerosols modifies the latter's PSD by ~10 % compared with Brownian coagulation. These results strongly suggest that electrostatic coagulation should be considered in air quality models.
- 28 February 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-20
Open AccessComment on egusphere-2026-486
Coagulation modifies the particle size distributions (PSD) of atmospheric aerosols, affecting their optical properties, cloud droplet activation, and gravitational deposition. While Coulomb forces may impact coagulation processes between charged aerosols, such as dust, most coagulation models neglect the effects of aerosol charge. Here, we address the lack of single-particle charge measurements for dust aerosols by developing a method to retrieve their joint size-charge distributions. By incorporating aerosol charge into the coagulation kernel, simulations in a dust-only scenario at typical environmental concentrations show that, on hourly timescales, electrostatic force leads to a reduction of up to ~64 % in number concentration relative to Brownian coagulation. Moreover, electrostatic coagulation between dust and ambient sub-500 nm aerosols modifies the latter's PSD by ~10 % compared with Brownian coagulation. These results strongly suggest that electrostatic coagulation should be considered in air quality models.
- Open Access
- 23 February 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-20
Comment on egusphere-2026-486
Coagulation modifies the particle size distributions (PSD) of atmospheric aerosols, affecting their optical properties, cloud droplet activation, and gravitational deposition. While Coulomb forces may impact coagulation processes between charged aerosols, such as dust, most coagulation models neglect the effects of aerosol charge. Here, we address the lack of single-particle charge measurements for dust aerosols by developing a method to retrieve their joint size-charge distributions. By incorporating aerosol charge into the coagulation kernel, simulations in a dust-only scenario at typical environmental concentrations show that, on hourly timescales, electrostatic force leads to a reduction of up to ~64 % in number concentration relative to Brownian coagulation. Moreover, electrostatic coagulation between dust and ambient sub-500 nm aerosols modifies the latter's PSD by ~10 % compared with Brownian coagulation. These results strongly suggest that electrostatic coagulation should be considered in air quality models.
- 23 February 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-20
Open AccessComment on egusphere-2026-486
Coagulation modifies the particle size distributions (PSD) of atmospheric aerosols, affecting their optical properties, cloud droplet activation, and gravitational deposition. While Coulomb forces may impact coagulation processes between charged aerosols, such as dust, most coagulation models neglect the effects of aerosol charge. Here, we address the lack of single-particle charge measurements for dust aerosols by developing a method to retrieve their joint size-charge distributions. By incorporating aerosol charge into the coagulation kernel, simulations in a dust-only scenario at typical environmental concentrations show that, on hourly timescales, electrostatic force leads to a reduction of up to ~64 % in number concentration relative to Brownian coagulation. Moreover, electrostatic coagulation between dust and ambient sub-500 nm aerosols modifies the latter's PSD by ~10 % compared with Brownian coagulation. These results strongly suggest that electrostatic coagulation should be considered in air quality models.
- Open Access
- 10 February 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-20
Critical Role of Dust Induced Electrostatic Coagulation in the Evolution of Aerosol Size Distributions in the Atmosphere
Coagulation modifies the particle size distributions (PSD) of atmospheric aerosols, affecting their optical properties, cloud droplet activation, and gravitational deposition. While Coulomb forces may impact coagulation processes between charged aerosols, such as dust, most coagulation models neglect the effects of aerosol charge. Here, we address the lack of single-particle charge measurements for dust aerosols by developing a method to retrieve their joint size-charge distributions. By incorporating aerosol charge into the coagulation kernel, simulations in a dust-only scenario at typical environmental concentrations show that, on hourly timescales, electrostatic force leads to a reduction of up to ~64 % in number concentration relative to Brownian coagulation. Moreover, electrostatic coagulation between dust and ambient sub-500 nm aerosols modifies the latter's PSD by ~10 % compared with Brownian coagulation. These results strongly suggest that electrostatic coagulation should be considered in air quality models.
- 10 February 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-20
Open AccessCritical Role of Dust Induced Electrostatic Coagulation in the Evolution of Aerosol Size Distributions in the Atmosphere
Coagulation modifies the particle size distributions (PSD) of atmospheric aerosols, affecting their optical properties, cloud droplet activation, and gravitational deposition. While Coulomb forces may impact coagulation processes between charged aerosols, such as dust, most coagulation models neglect the effects of aerosol charge. Here, we address the lack of single-particle charge measurements for dust aerosols by developing a method to retrieve their joint size-charge distributions. By incorporating aerosol charge into the coagulation kernel, simulations in a dust-only scenario at typical environmental concentrations show that, on hourly timescales, electrostatic force leads to a reduction of up to ~64 % in number concentration relative to Brownian coagulation. Moreover, electrostatic coagulation between dust and ambient sub-500 nm aerosols modifies the latter's PSD by ~10 % compared with Brownian coagulation. These results strongly suggest that electrostatic coagulation should be considered in air quality models.
- Open Access
- 18 November 2025
- Published by American Chemical Society (ACS) in ACS Environmental Au
- Vol. 6 (1) , 82-92
Development of Control Methods for Submicron Particulate Matter Emissions and Inhalation Exposure from Cosmetic Spray Products
Cosmetic spray products, widely used for personal care, are popular due to their ease of application and rapid, uniform coverage. However, the particulate matter (PM) that they emit can be inhaled and deposited in the respiratory tract, potentially posing respiratory health risks. Existing studies have seldom addressed emissions from cosmetic spray products applied directly to the human body, especially the face and neck, and few have proposed practical methods to reduce exposure. This study systematically evaluates the particle size distribution and number- and mass-based concentrations of 12 products under a laboratory setting that simulated real-use conditions. It is found that PM emissions from some spray products could be significant and strongly influenced by nozzle design and product chemical composition. The maximum PM10 number concentration reached 1.03 × 106 #/cm3, while the maximum PM10 mass concentration was 36.17 mg/m3. Using the Multiple-Path Particle Dosimetry model, we quantified the deposition doses across different respiratory regions (head, tracheobronchial, and pulmonary). To reduce exposure risks, a new development of actuator structures on a spray bottle was proposed and tested by incorporating external tubing and modifying mechanical breakup designs, without impairing the delivery efficiency of the product. Among these, tapered tubing was most effective, reducing total number- and mass-based deposition doses of submicron particles by 88.6% and 65.7%, respectively. The study highlighted significant differences in exposure risk among product types and proposed cost-effective, highly compatible engineering controls through nozzle modification, offering practical strategies for minimizing inhalation exposure from cosmetic spray products.
- 18 November 2025
- Published by American Chemical Society (ACS) in ACS Environmental Au
- Vol. 6 (1) , 82-92
Open AccessDevelopment of Control Methods for Submicron Particulate Matter Emissions and Inhalation Exposure from Cosmetic Spray Products
Cosmetic spray products, widely used for personal care, are popular due to their ease of application and rapid, uniform coverage. However, the particulate matter (PM) that they emit can be inhaled and deposited in the respiratory tract, potentially posing respiratory health risks. Existing studies have seldom addressed emissions from cosmetic spray products applied directly to the human body, especially the face and neck, and few have proposed practical methods to reduce exposure. This study systematically evaluates the particle size distribution and number- and mass-based concentrations of 12 products under a laboratory setting that simulated real-use conditions. It is found that PM emissions from some spray products could be significant and strongly influenced by nozzle design and product chemical composition. The maximum PM10 number concentration reached 1.03 × 106 #/cm3, while the maximum PM10 mass concentration was 36.17 mg/m3. Using the Multiple-Path Particle Dosimetry model, we quantified the deposition doses across different respiratory regions (head, tracheobronchial, and pulmonary). To reduce exposure risks, a new development of actuator structures on a spray bottle was proposed and tested by incorporating external tubing and modifying mechanical breakup designs, without impairing the delivery efficiency of the product. Among these, tapered tubing was most effective, reducing total number- and mass-based deposition doses of submicron particles by 88.6% and 65.7%, respectively. The study highlighted significant differences in exposure risk among product types and proposed cost-effective, highly compatible engineering controls through nozzle modification, offering practical strategies for minimizing inhalation exposure from cosmetic spray products.
- 13 September 2023
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 148, 298-305
Ultrasonic humidifier aerosols: Observed high heavy metal enrichment and a new emission control method
- 13 September 2023
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 148, 298-305
Ultrasonic humidifier aerosols: Observed high heavy metal enrichment and a new emission control method
- 10 March 2023
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 138, 88-101
Aqueous-phase formation of N-containing secondary organic compounds affected by the ionic strength
- 10 March 2023
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 138, 88-101
Aqueous-phase formation of N-containing secondary organic compounds affected by the ionic strength