Jacqueline Bakhit
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jacqueline Bakhit has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Benjamin Privett
Department of Surgery, Western Health, Melbourne, Australia
1 shared publicationBrian Soh
Department of General Surgery, Western Health, Melbourne, Victoria, Australia
1 shared publication- Coralie Simoni
Department of Medical Imaging Western Health Melbourne Victoria Australia
1 shared publication - Grace Carpenter
Department of Medical Imaging Western Health Melbourne Victoria Australia
1 shared publication - Jennifer Yuill
Department of Medical Imaging Western Health Melbourne Victoria Australia
1 shared publication - Joseph Paiva
Department of Medical Imaging Western Health Melbourne Victoria Australia
1 shared publication
Latest Publications
- Open Access
- 12 February 2026
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 70 (3) , 243-251
Preoperative Radar Localisation of Impalpable Breast and Axillary Lesions: Initial Experience in an Australian Tertiary Centre
Introduction: Image‐guided radar localisation (RL) is a wire‐free alternative to hookwire localisation (HWL) for preoperative localisation of impalpable breast and axillary lesions, with potential logistical and technical advantages. This study assesses clinical utility, accuracy of placement and surgical oncologic outcome metrics for RL using the SCOUT reflector compared to HWL after introduction in a tertiary Australian breast service. Methods: Retrospective comparative cohort analysis of consecutive RL with a contemporaneous historical HWL cohort of similar size (between January 2022 and March 2025) was performed. Key outcome markers included device migration, localisation procedure duration, retrieval issues, surgical margin status and breast malignancy re‐excision rates. Results: 287 patients were included (RL n = 144; HWL n = 143). No significant device migration was seen with RL compared to HWL (0.0% vs. 4.2%; p = 0.04) and retrieval issues were less common (4.2% vs. 9.8%; p = 0.10). Excluding MRI placement, procedure duration was shorter with RL (23 min vs. 28 min; p < 0.01). Negative, close, and positive margins were similar and re‐excision rates for breast malignancy comparable (12.5% RL vs 16.8% HWL, p = 0.42). Conclusion: RL is a safe, accurate localisation technique, demonstrating significantly fewer migration issues and fewer retrieval issues than HWL, while maintaining equivalent surgical oncologic outcomes. It offers logistical benefits of placement at any time prior to surgery (including time‐of‐biopsy placement), optimisation of radiology and surgical workflows, and versatility of axillary node and MRI‐guided placement and compatibility.
- 12 February 2026
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 70 (3) , 243-251
Open AccessPreoperative Radar Localisation of Impalpable Breast and Axillary Lesions: Initial Experience in an Australian Tertiary Centre
Introduction: Image‐guided radar localisation (RL) is a wire‐free alternative to hookwire localisation (HWL) for preoperative localisation of impalpable breast and axillary lesions, with potential logistical and technical advantages. This study assesses clinical utility, accuracy of placement and surgical oncologic outcome metrics for RL using the SCOUT reflector compared to HWL after introduction in a tertiary Australian breast service. Methods: Retrospective comparative cohort analysis of consecutive RL with a contemporaneous historical HWL cohort of similar size (between January 2022 and March 2025) was performed. Key outcome markers included device migration, localisation procedure duration, retrieval issues, surgical margin status and breast malignancy re‐excision rates. Results: 287 patients were included (RL n = 144; HWL n = 143). No significant device migration was seen with RL compared to HWL (0.0% vs. 4.2%; p = 0.04) and retrieval issues were less common (4.2% vs. 9.8%; p = 0.10). Excluding MRI placement, procedure duration was shorter with RL (23 min vs. 28 min; p < 0.01). Negative, close, and positive margins were similar and re‐excision rates for breast malignancy comparable (12.5% RL vs 16.8% HWL, p = 0.42). Conclusion: RL is a safe, accurate localisation technique, demonstrating significantly fewer migration issues and fewer retrieval issues than HWL, while maintaining equivalent surgical oncologic outcomes. It offers logistical benefits of placement at any time prior to surgery (including time‐of‐biopsy placement), optimisation of radiology and surgical workflows, and versatility of axillary node and MRI‐guided placement and compatibility.
- 30 November 2019
- Published by Wiley in Anz Journal of Surgery
- Vol. 90 (1-2) , 72-75
Laparoscopic EndoClose fixation of a peritoneal catheter reduces migration
Background: With the introduction of laparoscopic Tenckhoff catheter insertion in the early 1990s, catheter malposition resulting in malfunction remains a frequent complication, often requiring surgical or radiological intervention. In this pioneer study, we describe the technique of suturing the Tenckhoff catheter using an EndoClose (Medtronic, Macquarie Park, NSW, Australia) device to the anterior abdominal wall during laparoscopic insertion and compare its outcomes with those not sutured.Methods: This is a retrospective study of all patients who underwent laparoscopic Tenckhoff catheter insertion at Western Health from January 2013 to June 2018. All procedures were undertaken or supervised by one surgeon. The primary outcome was catheter malposition requiring surgical revision. Secondary outcomes were time to malposition and complications. Peri‐ and post‐operative factors were analysed to adjust for confounders using the Cochran–Mantel–Haenszel test.Results: There were 82 patients in the sutured group and 63 patients in the non‐sutured group. Catheter malposition occurred in 7.32% in the sutured group and 19.05% in the non‐sutured group (P = 0.034; 95% confidence interval for the difference 0.007–0.237). There was an overall reduction in the odds of catheter malposition of 63% in favour of the sutured group. The median time‐to‐malposition was 128 and 182 days for the non‐sutured and sutured group, respectively, but not statistically different. No differences were found for the number of post‐operative complications.Conclusion: Suturing of Tenckhoff catheter with an EndoClose device to the anterior abdominal wall during laparoscopic insertion is a simple, safe and useful method of reducing catheter malposition.
- 30 November 2019
- Published by Wiley in Anz Journal of Surgery
- Vol. 90 (1-2) , 72-75
Laparoscopic EndoClose fixation of a peritoneal catheter reduces migration
Background: With the introduction of laparoscopic Tenckhoff catheter insertion in the early 1990s, catheter malposition resulting in malfunction remains a frequent complication, often requiring surgical or radiological intervention. In this pioneer study, we describe the technique of suturing the Tenckhoff catheter using an EndoClose (Medtronic, Macquarie Park, NSW, Australia) device to the anterior abdominal wall during laparoscopic insertion and compare its outcomes with those not sutured.Methods: This is a retrospective study of all patients who underwent laparoscopic Tenckhoff catheter insertion at Western Health from January 2013 to June 2018. All procedures were undertaken or supervised by one surgeon. The primary outcome was catheter malposition requiring surgical revision. Secondary outcomes were time to malposition and complications. Peri‐ and post‐operative factors were analysed to adjust for confounders using the Cochran–Mantel–Haenszel test.Results: There were 82 patients in the sutured group and 63 patients in the non‐sutured group. Catheter malposition occurred in 7.32% in the sutured group and 19.05% in the non‐sutured group (P = 0.034; 95% confidence interval for the difference 0.007–0.237). There was an overall reduction in the odds of catheter malposition of 63% in favour of the sutured group. The median time‐to‐malposition was 128 and 182 days for the non‐sutured and sutured group, respectively, but not statistically different. No differences were found for the number of post‐operative complications.Conclusion: Suturing of Tenckhoff catheter with an EndoClose device to the anterior abdominal wall during laparoscopic insertion is a simple, safe and useful method of reducing catheter malposition.
- Open Access
- 1 March 2019
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2019 (3) , rjz094
Laparoscopic trans-cystic common bile duct stone retrieval in a patient with gallbladder agenesis
Gallbladder agenesis is a rare but well-documented anatomical variation. Pre-operative diagnosis may be difficult as patients can present with typical symptoms of biliary colic and imaging may be misleading. We report a case of choledochoscopy and common bile duct stone retrieval in a patient found to have agenesis of the gallbladder intra-operatively.
- 1 March 2019
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2019 (3) , rjz094
Open AccessLaparoscopic trans-cystic common bile duct stone retrieval in a patient with gallbladder agenesis
Gallbladder agenesis is a rare but well-documented anatomical variation. Pre-operative diagnosis may be difficult as patients can present with typical symptoms of biliary colic and imaging may be misleading. We report a case of choledochoscopy and common bile duct stone retrieval in a patient found to have agenesis of the gallbladder intra-operatively.
- Open Access
- 1 January 2019
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2019 (1) , rjz012
Proceed or palliate: Surgicel® mimicking tumor recurrence and causing a small bowel obstruction
Surgicel® is a commonly used hemostatic agent. We report a case of small bowel obstruction secondary to the prior placement of Surgicel® within the peritoneal cavity, and the radiological diagnosis conundrum and potential prognostic implications this finding has in a patient with a known history of malignancy.
- 1 January 2019
- Published by Oxford University Press (OUP) in Journal of Surgical Case Reports
- Vol. 2019 (1) , rjz012
Open AccessProceed or palliate: Surgicel® mimicking tumor recurrence and causing a small bowel obstruction
Surgicel® is a commonly used hemostatic agent. We report a case of small bowel obstruction secondary to the prior placement of Surgicel® within the peritoneal cavity, and the radiological diagnosis conundrum and potential prognostic implications this finding has in a patient with a known history of malignancy.