Marko Radovic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Marko Radovic has a total of 137 co-authors. Here are the top co-authors by number of shared publications:
- Branko Matović
Vinča Institute of Nuclear Sciences,Vinča,Serbia, Serbia
10 shared publications - Zorana Dohcevic-Mitrovic
Institut za fiziku, Centar za fiziku čvrstog stanja i nove materijale, Beograd
6 shared publications - Georges Dubourg
BioSense Institute University of Novi Sad Novi Sad Serbia
5 shared publications - Maja Scepanovic
University of Belgrade, Institute of Physics Belgrade, Center for Solid State and New Materials, 11000 Belgrade, Serbia
5 shared publications - Stefan Jaric
BioSense Institute, Research and Development Institute for Information Technologies in Biosystems, University of Novi Sad, Dr Zorana Đinđića 1, 21000 Novi Sad, Serbia
4 shared publications - Vasa Radonic
BioSense Institute, Novi Sad, Serbia
4 shared publications
Latest Publications
- Open Access
- 6 September 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (9) , 498
Optical and Electrochemical Biosensors Using Electrochemically Etched Porous Silicon
Versatile nanostructured materials based on electrochemically etched porous silicon (pSi) are being developed, which have tuneable pore morphology and unique optical and electrochemical properties that enable their effective biosensing applications. It has been shown that fabrication parameters critically influence pore formation and sensor performance, yet challenges remain in reproducible synthesis, structural stability and device integration. Here we review the electrochemical etching synthesis of pSi and recent advances in pSi-based optical and electrochemical biosensors for detecting bacteria, biomolecules, and viruses. We highlight strategies such as surface functionalisation, incorporation of nanomaterials, and integration with microfluidic and lab-on-a-chip technologies that enhance sensitivity and response times by addressing mass transfer limitations. These developments highlight pSi’s potential as a low-cost, adaptable biosensing material with applications in clinical diagnostics and environmental monitoring, while mapping future directions to overcome current fabrication and stability challenges.
- 6 September 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (9) , 498
Open AccessOptical and Electrochemical Biosensors Using Electrochemically Etched Porous Silicon
Versatile nanostructured materials based on electrochemically etched porous silicon (pSi) are being developed, which have tuneable pore morphology and unique optical and electrochemical properties that enable their effective biosensing applications. It has been shown that fabrication parameters critically influence pore formation and sensor performance, yet challenges remain in reproducible synthesis, structural stability and device integration. Here we review the electrochemical etching synthesis of pSi and recent advances in pSi-based optical and electrochemical biosensors for detecting bacteria, biomolecules, and viruses. We highlight strategies such as surface functionalisation, incorporation of nanomaterials, and integration with microfluidic and lab-on-a-chip technologies that enhance sensitivity and response times by addressing mass transfer limitations. These developments highlight pSi’s potential as a low-cost, adaptable biosensing material with applications in clinical diagnostics and environmental monitoring, while mapping future directions to overcome current fabrication and stability challenges.
- Open Access
- 5 September 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (9) , 584
Advanced Nanomaterial-Based Electrochemical Biosensing of Loop-Mediated Isothermal Amplification Products
The rapid and sensitive detection of regulatory elements within transgenic constructs of genetically modified organisms (GMOs) is essential for effective monitoring and control of their distribution. In this study, we present several innovative electrochemical biosensing platforms for the detection of regulatory sequences in genetically modified (GM) plants, combining the loop-mediated isothermal amplification (LAMP) method with electrodes functionalized by two-dimensional (2D) nanomaterials. The sensor design exploits the high surface area and excellent conductivity of reduced graphene oxide, Ti3C2Tx, and molybdenum disulfide (MoS2) to enhance signal transduction. Furthermore, we used a “green synthesis” method for Ti3C2Tx preparation that eliminates the use of hazardous hydrofluoric acid (HF) and hydrochloric acid (HCl), providing a safer and more sustainable approach for nanomaterial production. Within this framework, the performance of various custom-fabricated electrodes, including laser-patterned gold leaf films, physical vapor deposition (PVD)-deposited gold electrodes, and screen-printed gold electrodes, is evaluated and compared with commercial screen-printed gold electrodes. Additionally, gold and carbon electrodes were electrochemically covered by gold nanoparticles (AuNPs), and their properties were compared. Several electrochemical methods were used during the DNA detection, and their importance and differences in excitation signal were highlighted. Electrochemical properties, sensitivity, selectivity, and reproducibility are characterized for each electrode type to assess the influence of fabrication methods and material composition on sensor performance. The developed biosensing systems exhibit high sensitivity, specificity, and rapid response, highlighting their potential as practical tools for on-site GMO screening and regulatory compliance monitoring. This work advances electrochemical nucleic acid detection by integrating environmentally-friendly nanomaterial synthesis with robust biosensing technology.
- 5 September 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (9) , 584
Open AccessAdvanced Nanomaterial-Based Electrochemical Biosensing of Loop-Mediated Isothermal Amplification Products
The rapid and sensitive detection of regulatory elements within transgenic constructs of genetically modified organisms (GMOs) is essential for effective monitoring and control of their distribution. In this study, we present several innovative electrochemical biosensing platforms for the detection of regulatory sequences in genetically modified (GM) plants, combining the loop-mediated isothermal amplification (LAMP) method with electrodes functionalized by two-dimensional (2D) nanomaterials. The sensor design exploits the high surface area and excellent conductivity of reduced graphene oxide, Ti3C2Tx, and molybdenum disulfide (MoS2) to enhance signal transduction. Furthermore, we used a “green synthesis” method for Ti3C2Tx preparation that eliminates the use of hazardous hydrofluoric acid (HF) and hydrochloric acid (HCl), providing a safer and more sustainable approach for nanomaterial production. Within this framework, the performance of various custom-fabricated electrodes, including laser-patterned gold leaf films, physical vapor deposition (PVD)-deposited gold electrodes, and screen-printed gold electrodes, is evaluated and compared with commercial screen-printed gold electrodes. Additionally, gold and carbon electrodes were electrochemically covered by gold nanoparticles (AuNPs), and their properties were compared. Several electrochemical methods were used during the DNA detection, and their importance and differences in excitation signal were highlighted. Electrochemical properties, sensitivity, selectivity, and reproducibility are characterized for each electrode type to assess the influence of fabrication methods and material composition on sensor performance. The developed biosensing systems exhibit high sensitivity, specificity, and rapid response, highlighting their potential as practical tools for on-site GMO screening and regulatory compliance monitoring. This work advances electrochemical nucleic acid detection by integrating environmentally-friendly nanomaterial synthesis with robust biosensing technology.
- Top Cited PapersOpen Access
Recent Advances in Biosensor Technologies for Meat Production Chain
Biosensors are innovative and cost-effective analytical devices that integrate biological recognition elements (bioreceptors) with transducers to detect specific substances (biomolecules), providing a high sensitivity and specificity for the rapid and accurate point-of-care (POC) quantitative detection of selected biomolecules. In the meat production chain, their application has gained attention due to the increasing demand for enhanced food safety, quality assurance, food fraud detection, and regulatory compliance. Biosensors can detect foodborne pathogens (Salmonella, Campylobacter, Shiga-toxin-producing E. coli/STEC, L. monocytogenes, etc.), spoilage bacteria and indicators, contaminants (pesticides, dioxins, and mycotoxins), antibiotics, antimicrobial resistance genes, hormones (growth promoters and stress hormones), and metabolites (acute-phase proteins as inflammation markers) at different modules along the meat chain, from livestock farming to packaging in the farm-to-fork (F2F) continuum. By providing real-time data from the meat chain, biosensors enable early interventions, reducing the health risks (foodborne outbreaks) associated with contaminated meat/meat products or sub-standard meat products. Recent advancements in micro- and nanotechnology, microfluidics, and wireless communication have further enhanced the sensitivity, specificity, portability, and automation of biosensors, making them suitable for on-site field applications. The integration of biosensors with blockchain and Internet of Things (IoT) systems allows for acquired data integration and management, while their integration with artificial intelligence (AI) and machine learning (ML) enables rapid data processing, analytics, and input for risk assessment by competent authorities. This promotes transparency and traceability within the meat chain, fostering consumer trust and industry accountability. Despite biosensors’ promising potential, challenges such as scalability, reliability associated with the complexity of meat matrices, and regulatory approval are still the main challenges. This review provides a broad overview of the most relevant aspects of current state-of-the-art biosensors’ development, challenges, and opportunities for prospective applications and their regular use in meat safety and quality monitoring, clarifying further perspectives.
Top Cited PapersOpen AccessRecent Advances in Biosensor Technologies for Meat Production Chain
Biosensors are innovative and cost-effective analytical devices that integrate biological recognition elements (bioreceptors) with transducers to detect specific substances (biomolecules), providing a high sensitivity and specificity for the rapid and accurate point-of-care (POC) quantitative detection of selected biomolecules. In the meat production chain, their application has gained attention due to the increasing demand for enhanced food safety, quality assurance, food fraud detection, and regulatory compliance. Biosensors can detect foodborne pathogens (Salmonella, Campylobacter, Shiga-toxin-producing E. coli/STEC, L. monocytogenes, etc.), spoilage bacteria and indicators, contaminants (pesticides, dioxins, and mycotoxins), antibiotics, antimicrobial resistance genes, hormones (growth promoters and stress hormones), and metabolites (acute-phase proteins as inflammation markers) at different modules along the meat chain, from livestock farming to packaging in the farm-to-fork (F2F) continuum. By providing real-time data from the meat chain, biosensors enable early interventions, reducing the health risks (foodborne outbreaks) associated with contaminated meat/meat products or sub-standard meat products. Recent advancements in micro- and nanotechnology, microfluidics, and wireless communication have further enhanced the sensitivity, specificity, portability, and automation of biosensors, making them suitable for on-site field applications. The integration of biosensors with blockchain and Internet of Things (IoT) systems allows for acquired data integration and management, while their integration with artificial intelligence (AI) and machine learning (ML) enables rapid data processing, analytics, and input for risk assessment by competent authorities. This promotes transparency and traceability within the meat chain, fostering consumer trust and industry accountability. Despite biosensors’ promising potential, challenges such as scalability, reliability associated with the complexity of meat matrices, and regulatory approval are still the main challenges. This review provides a broad overview of the most relevant aspects of current state-of-the-art biosensors’ development, challenges, and opportunities for prospective applications and their regular use in meat safety and quality monitoring, clarifying further perspectives.
- Open Access
- 23 January 2025
- Published by MDPI AG in Preprints.org
Biosensors in the Meat Production Chain
Biosensors are innovative and cost-effective analytical devices that integrate biological recognition elements (bioreceptors) with transducers to detect specific substances (biomolecules), providing high sensitivity and specificity for rapid and accurate Point-of-Care (POC) quantitative detection of selected biomolecules. In the meat production chain, their application has gained attention due to the increasing demand for enhanced food safety, quality assurance, food fraud detection and regulatory compliance demands. Biosensors can detect foodborne pathogens (Salmonella, Campylobacter, Shiga toxin-producing E. coli/STEC, L. monocytogenes), spoilage bacteria and indicators, contaminants (pesticides, dioxins, mycotoxins), antibiotics, antimicrobial resistance genes, hormones (growth promoters, stress hormones), metabolites (acute phase proteins as inflammation markers) at different modules along the meat chain, from livestock farming to packaging in farm-to-fork (F2F) continuum. By providing real-time data from the meat chain, biosensors enable early interventions, reducing health risks (foodborne outbreaks) associated with contaminated meat/meat products or substandard meat products. Recent advancements in micro and nanotechnology, microfluidics, and wireless communication have further enhanced the sensitivity, specificity, portability, and automation of biosensors, making them suitable for on-site, field applications. Integration of biosensors with blockchain and Internet of Things (IoT) systems allows acquired data integration and management, while integration with Artificial Intelligence (AI) and Machine Learning (ML) enables rapid data processing, analytics and input for risk assessment by competent authorities. This promotes transparency and traceability within the meat chain, fostering consumer trust and industry accountability. Despite biosensors’ promising potential, challenges such as scalability, reliability associated with the complexity of meat matrices and regulatory approval, are still the main challenges. This review provides a broad overview of the most relevant aspects of the current state-of-the-art biosensors` development, challenges and opportunities for prospective biosensors` application and its regular use in meat safety and quality monitoring and clarify further perspectives.
- 23 January 2025
- Published by MDPI AG in Preprints.org
Open AccessBiosensors in the Meat Production Chain
Biosensors are innovative and cost-effective analytical devices that integrate biological recognition elements (bioreceptors) with transducers to detect specific substances (biomolecules), providing high sensitivity and specificity for rapid and accurate Point-of-Care (POC) quantitative detection of selected biomolecules. In the meat production chain, their application has gained attention due to the increasing demand for enhanced food safety, quality assurance, food fraud detection and regulatory compliance demands. Biosensors can detect foodborne pathogens (Salmonella, Campylobacter, Shiga toxin-producing E. coli/STEC, L. monocytogenes), spoilage bacteria and indicators, contaminants (pesticides, dioxins, mycotoxins), antibiotics, antimicrobial resistance genes, hormones (growth promoters, stress hormones), metabolites (acute phase proteins as inflammation markers) at different modules along the meat chain, from livestock farming to packaging in farm-to-fork (F2F) continuum. By providing real-time data from the meat chain, biosensors enable early interventions, reducing health risks (foodborne outbreaks) associated with contaminated meat/meat products or substandard meat products. Recent advancements in micro and nanotechnology, microfluidics, and wireless communication have further enhanced the sensitivity, specificity, portability, and automation of biosensors, making them suitable for on-site, field applications. Integration of biosensors with blockchain and Internet of Things (IoT) systems allows acquired data integration and management, while integration with Artificial Intelligence (AI) and Machine Learning (ML) enables rapid data processing, analytics and input for risk assessment by competent authorities. This promotes transparency and traceability within the meat chain, fostering consumer trust and industry accountability. Despite biosensors’ promising potential, challenges such as scalability, reliability associated with the complexity of meat matrices and regulatory approval, are still the main challenges. This review provides a broad overview of the most relevant aspects of the current state-of-the-art biosensors` development, challenges and opportunities for prospective biosensors` application and its regular use in meat safety and quality monitoring and clarify further perspectives.
- Open Access
- 4 January 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (2) , 2841-2849
Rapid Detection and Identification of Vancomycin-Sensitive Bacteria Using an Electrochemical Apta-Sensor
In order to combat the complex and diverse infections caused by bacteria, it is essential to develop efficient diagnostic tools. Current techniques for bacterial detection rely on laborious multistep procedures, with high costs and extended time of analysis. To overcome these limitations, we propose here a novel portable electrochemical biosensor for the rapid detection and identification of Gram-positive bacteria that leverages the recognition capabilities of vancomycin and aptamers. A vancomycin-modified screen-printed carbon electrode was used to selectively capture Gram-positive bacteria susceptible to this antibiotic. Electrochemical impedance spectroscopy and scanning electron microscopy demonstrated that capture was achieved in 10 min, with a limit of detection of only 2 CFU/mL. We then tested the device's potential for aptamer-based bacterial identification using Staphylococcus aureus and Bacillus cereus as the test strains. Specifically, electrodes with captured bacteria were exposed to species-specific aptamers, and the resulting changes in current intensity were analyzed using differential pulse voltammetry. When used directly in untreated milk or serum, the system was able to successfully identify a small amount of S. aureus and B. cereus (100 CFU/mL) in less than 45 min. This novel biosensor has the potential to serve as an invaluable tool that could be used, even by inexperienced staff, in a broad range of settings including clinical diagnostics, food safety analysis, environmental monitoring, and security applications.
- 4 January 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (2) , 2841-2849
Open AccessRapid Detection and Identification of Vancomycin-Sensitive Bacteria Using an Electrochemical Apta-Sensor
In order to combat the complex and diverse infections caused by bacteria, it is essential to develop efficient diagnostic tools. Current techniques for bacterial detection rely on laborious multistep procedures, with high costs and extended time of analysis. To overcome these limitations, we propose here a novel portable electrochemical biosensor for the rapid detection and identification of Gram-positive bacteria that leverages the recognition capabilities of vancomycin and aptamers. A vancomycin-modified screen-printed carbon electrode was used to selectively capture Gram-positive bacteria susceptible to this antibiotic. Electrochemical impedance spectroscopy and scanning electron microscopy demonstrated that capture was achieved in 10 min, with a limit of detection of only 2 CFU/mL. We then tested the device's potential for aptamer-based bacterial identification using Staphylococcus aureus and Bacillus cereus as the test strains. Specifically, electrodes with captured bacteria were exposed to species-specific aptamers, and the resulting changes in current intensity were analyzed using differential pulse voltammetry. When used directly in untreated milk or serum, the system was able to successfully identify a small amount of S. aureus and B. cereus (100 CFU/mL) in less than 45 min. This novel biosensor has the potential to serve as an invaluable tool that could be used, even by inexperienced staff, in a broad range of settings including clinical diagnostics, food safety analysis, environmental monitoring, and security applications.
- Open Access
Mammalian Cell-Growth Monitoring Based on an Impedimetric Sensor and Image Processing within a Microfluidic Platform
In recent years, advancements in microfluidic and sensor technologies have led to the development of new methods for monitoring cell growth both in macro- and micro-systems. In this paper, a microfluidic (MF) platform with a microbioreactor and integrated impedimetric sensor is proposed for cell growth monitoring during the cell cultivation process in a scaled-down simulator. The impedimetric sensor with an interdigitated electrode (IDE) design was realized with inkjet printing and integrated into the custom-made MF platform, i.e., the scaled-down simulator. The proposed method, which was integrated into a simple and rapid fabrication MF system, presents an excellent candidate for the scaled-down analyses of cell growths that can be of use in, e.g., optimization of the cultivated meat bioprocess. When applied to MRC-5 cells as a model of adherent mammalian cells, the proposed sensor was able to precisely detect all phases of cell growth (the lag, exponential, stationary, and dying phases) during a 96-h cultivation period with limited available nutrients. By combining the impedimetric approach with image processing, the platform enables the real-time monitoring of biomasses and advanced control of cell growth progress in microbioreactors and scaled-down simulator systems.
Open AccessMammalian Cell-Growth Monitoring Based on an Impedimetric Sensor and Image Processing within a Microfluidic Platform
In recent years, advancements in microfluidic and sensor technologies have led to the development of new methods for monitoring cell growth both in macro- and micro-systems. In this paper, a microfluidic (MF) platform with a microbioreactor and integrated impedimetric sensor is proposed for cell growth monitoring during the cell cultivation process in a scaled-down simulator. The impedimetric sensor with an interdigitated electrode (IDE) design was realized with inkjet printing and integrated into the custom-made MF platform, i.e., the scaled-down simulator. The proposed method, which was integrated into a simple and rapid fabrication MF system, presents an excellent candidate for the scaled-down analyses of cell growths that can be of use in, e.g., optimization of the cultivated meat bioprocess. When applied to MRC-5 cells as a model of adherent mammalian cells, the proposed sensor was able to precisely detect all phases of cell growth (the lag, exponential, stationary, and dying phases) during a 96-h cultivation period with limited available nutrients. By combining the impedimetric approach with image processing, the platform enables the real-time monitoring of biomasses and advanced control of cell growth progress in microbioreactors and scaled-down simulator systems.
- Open Access
- 13 October 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (10) , 2700
Advances in Nanomaterials-Based Electrochemical Biosensors for Foodborne Pathogen Detection
Electrochemical biosensors utilizing nanomaterials have received widespread attention in pathogen detection and monitoring. Here, the potential of different nanomaterials and electrochemical technologies is reviewed for the development of novel diagnostic devices for the detection of foodborne pathogens and their biomarkers. The overview covers basic electrochemical methods and means for electrode functionalization, utilization of nanomaterials that include quantum dots, gold, silver and magnetic nanoparticles, carbon nanomaterials (carbon and graphene quantum dots, carbon nanotubes, graphene and reduced graphene oxide, graphene nanoplatelets, laser-induced graphene), metal oxides (nanoparticles, 2D and 3D nanostructures) and other 2D nanomaterials. Moreover, the current and future landscape of synergic effects of nanocomposites combining different nanomaterials is provided to illustrate how the limitations of traditional technologies can be overcome to design rapid, ultrasensitive, specific and affordable biosensors.
- 13 October 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (10) , 2700
Open AccessAdvances in Nanomaterials-Based Electrochemical Biosensors for Foodborne Pathogen Detection
Electrochemical biosensors utilizing nanomaterials have received widespread attention in pathogen detection and monitoring. Here, the potential of different nanomaterials and electrochemical technologies is reviewed for the development of novel diagnostic devices for the detection of foodborne pathogens and their biomarkers. The overview covers basic electrochemical methods and means for electrode functionalization, utilization of nanomaterials that include quantum dots, gold, silver and magnetic nanoparticles, carbon nanomaterials (carbon and graphene quantum dots, carbon nanotubes, graphene and reduced graphene oxide, graphene nanoplatelets, laser-induced graphene), metal oxides (nanoparticles, 2D and 3D nanostructures) and other 2D nanomaterials. Moreover, the current and future landscape of synergic effects of nanocomposites combining different nanomaterials is provided to illustrate how the limitations of traditional technologies can be overcome to design rapid, ultrasensitive, specific and affordable biosensors.
- Open Access
- 2 January 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (1) , 80
Laser-Tunable Printed ZnO Nanoparticles for Paper-Based UV Sensors with Reduced Humidity Interference
Development of paper-based sensors that do not suffer with humidity interference is desirable for practical environmental applications. In this work, a laser processing method was reported to effectively modulate the cross-sensitivity to humidity of ZnO-based UV (Ultraviolet) sensors printed on paper substrate. The results reveal that the laser induced zinc oxide (ZnO) surface morphology contributes to the super-hydrophobicity of the printed ZnO nanoparticles, reducing humidity interference while enhancing UV sensitivity. Herein, this conducted research highlights for the first time that laser processing is an attractive choice that reduces the cross-sensitivity to water vapor in the UV sensing response of ZnO-based devices printed on paper, paving the way to low-cost and sophisticated paper-based sensors.
- 2 January 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (1) , 80
Open AccessLaser-Tunable Printed ZnO Nanoparticles for Paper-Based UV Sensors with Reduced Humidity Interference
Development of paper-based sensors that do not suffer with humidity interference is desirable for practical environmental applications. In this work, a laser processing method was reported to effectively modulate the cross-sensitivity to humidity of ZnO-based UV (Ultraviolet) sensors printed on paper substrate. The results reveal that the laser induced zinc oxide (ZnO) surface morphology contributes to the super-hydrophobicity of the printed ZnO nanoparticles, reducing humidity interference while enhancing UV sensitivity. Herein, this conducted research highlights for the first time that laser processing is an attractive choice that reduces the cross-sensitivity to water vapor in the UV sensing response of ZnO-based devices printed on paper, paving the way to low-cost and sophisticated paper-based sensors.
- Open Access
- 1 January 2020
- Published by National Library of Serbia in Processing and Application of Ceramics
- Vol. 14 (2) , 102-112
Influence of oxygen vacancy defects and cobalt doping on optical, electronic and photocatalytic properties of ultrafine SnO2-δ nanocrystals
Ultrafine pure and cobalt doped SnO2-? nanocrystals (Sn1-xCoxO2-?, 0 ? x ? 0.05) were synthesized by microwave-assisted hydrothermal method. The as-prepared nanocrystals have single phase tetragonal rutile structure. With increase of Co content (x > 0.01), Co entered into SnO2 lattice in mixed Co2+/Co3+ state. Pronounced blue shift of the band gap with cobalt doping originated from the combined effect of quantum confinement and Burnstain-Moss shift. Raman and photoluminescence study revealed oxygen deficient structure of SnO2-? for which the prevalent defects are in the form of in-plane oxygen vacancies. Co-doping induced decrease of in-plane oxygen vacancy concentration and luminescence quenching. SnO2-? exhibited significantly better photocatalytic activity under UV light irradiation, than Co-doped samples due to better UV light absorption and increased concentration of in-plane oxygen vacancies which, as shallow donors, enable better electron-hole separation and faster charge transport.
- 1 January 2020
- Published by National Library of Serbia in Processing and Application of Ceramics
- Vol. 14 (2) , 102-112
Open AccessInfluence of oxygen vacancy defects and cobalt doping on optical, electronic and photocatalytic properties of ultrafine SnO2-δ nanocrystals
Ultrafine pure and cobalt doped SnO2-? nanocrystals (Sn1-xCoxO2-?, 0 ? x ? 0.05) were synthesized by microwave-assisted hydrothermal method. The as-prepared nanocrystals have single phase tetragonal rutile structure. With increase of Co content (x > 0.01), Co entered into SnO2 lattice in mixed Co2+/Co3+ state. Pronounced blue shift of the band gap with cobalt doping originated from the combined effect of quantum confinement and Burnstain-Moss shift. Raman and photoluminescence study revealed oxygen deficient structure of SnO2-? for which the prevalent defects are in the form of in-plane oxygen vacancies. Co-doping induced decrease of in-plane oxygen vacancy concentration and luminescence quenching. SnO2-? exhibited significantly better photocatalytic activity under UV light irradiation, than Co-doped samples due to better UV light absorption and increased concentration of in-plane oxygen vacancies which, as shallow donors, enable better electron-hole separation and faster charge transport.