Shuyu Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shuyu Lin has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Fu Zhiqiang
1 shared publicationHu Jing
1 shared publicationWang Yong
1 shared publicationZhang Xiaoli
1 shared publication
Latest Publications
- 1 September 2013
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 20 (5) , 1161-1167
Radial vibration and ultrasonic field of a long tubular ultrasonic radiator
- 1 September 2013
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 20 (5) , 1161-1167
Radial vibration and ultrasonic field of a long tubular ultrasonic radiator
- 1 March 2007
- Published by Elsevier in Ultrasonics
- Vol. 46 (1) , 51-59
Study on the radial composite piezoelectric ceramic transducer in radial vibration
- 1 March 2007
- Published by Elsevier in Ultrasonics
- Vol. 46 (1) , 51-59
Study on the radial composite piezoelectric ceramic transducer in radial vibration
- 1 December 2006
- Published by Elsevier in Ultrasonics
- Vol. 44, e545-e548
Study on the high power air-coupled ultrasonic compound transducer
- 1 December 2006
- Published by Elsevier in Ultrasonics
- Vol. 44, e545-e548
Study on the high power air-coupled ultrasonic compound transducer
- 28 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 53 (9) , 1671-1678
Study on a new type of radial composite piezoelectric ultrasonic transducers in radial vibration
In this paper, a new type of radial composite ultrasonic transducers in radial vibration is presented and studied. The radial composite ultrasonic transducer consists of a solid piezoelectric ceramic thin disk and a hollow metal thin, circular ring in radial vibration; and they are connected together in the radial direction. The radial vibrations of a piezoelectric ceramic thin disk and a hollow, metal, thin, circular ring are analyzed, respectively. Their radial electromechanical equivalent circuits are obtained. Based on the electromechanical equivalent circuits and using the boundary conditions between the piezoelectric ceramic thin disk and the hollow, metal, thin ring, the electromechanical equivalent circuit of the radial composite ultrasonic transducer is derived and the resonance frequency equation is obtained. The theoretical results from the resonance frequency equation are in good agreement with the measured radial resonance frequencies, and they also are in a good agreement with the results from the numerical method
- 28 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 53 (9) , 1671-1678
Study on a new type of radial composite piezoelectric ultrasonic transducers in radial vibration
In this paper, a new type of radial composite ultrasonic transducers in radial vibration is presented and studied. The radial composite ultrasonic transducer consists of a solid piezoelectric ceramic thin disk and a hollow metal thin, circular ring in radial vibration; and they are connected together in the radial direction. The radial vibrations of a piezoelectric ceramic thin disk and a hollow, metal, thin, circular ring are analyzed, respectively. Their radial electromechanical equivalent circuits are obtained. Based on the electromechanical equivalent circuits and using the boundary conditions between the piezoelectric ceramic thin disk and the hollow, metal, thin ring, the electromechanical equivalent circuit of the radial composite ultrasonic transducer is derived and the resonance frequency equation is obtained. The theoretical results from the resonance frequency equation are in good agreement with the measured radial resonance frequencies, and they also are in a good agreement with the results from the numerical method
- 1 January 2006
- Published by Elsevier in Ultrasonics
- Vol. 44 (1) , 109-114
Study on the Langevin piezoelectric ceramic ultrasonic transducer of longitudinal–flexural composite vibrational mode
- 1 January 2006
- Published by Elsevier in Ultrasonics
- Vol. 44 (1) , 109-114
Study on the Langevin piezoelectric ceramic ultrasonic transducer of longitudinal–flexural composite vibrational mode
- 1 March 2005
- Published by Elsevier in Ultrasonics
- Vol. 43 (5) , 365-373
Load characteristics of high power sandwich piezoelectric ultrasonic transducers
- 1 March 2005
- Published by Elsevier in Ultrasonics
- Vol. 43 (5) , 365-373
Load characteristics of high power sandwich piezoelectric ultrasonic transducers
- 1 November 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 51 (10) , 1280-1286
Effect of electric load impedances on the performance of sandwich piezoelectric transducers
Based on the electromechanical equivalent circuit, the sandwich piezoelectric transducer with adjustable resonance frequency is studied. The underlying theory of frequency adjustment is its piezoelectric effect. In this paper, the influence of electric load impedance (including electric resistance, electric inductance, and electric capacitance) on the resonance frequency, the antiresonance frequency, and the effective electromechanical coupling coefficient is analyzed theoretically and experimentally. It is demonstrated that the electric load impedance can change the resonance frequency, the antiresonance frequency, and the effective electromechanical coupling coefficient. When the electric load resistance is increased, the resonance frequency and the antiresonance frequency are increased; the effective electromechanical coupling coefficient has a maximum value when the electric load resistance changes. When the electric load resistance becomes large, the effect of the electric load resistance on the effective electromechanical coupling coefficient is negligible. When the electric load inductance is increased, the resonance frequency and the antiresonance frequency are decreased, whereas the effective electromechanical coupling coefficient is increased. When the electric load capacitance is increased, the resonance frequency, the antiresonance frequency, and the effective electromechanical coupling coefficient are all decreased. It should be noted that when the electric load impedance becomes large, the effect of the electric load impedance on the resonance frequency, the antiresonance frequency, and the effective electromechanical coupling coefficient of a sandwich piezoelectric transducer becomes negligible.
- 1 November 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 51 (10) , 1280-1286
Effect of electric load impedances on the performance of sandwich piezoelectric transducers
Based on the electromechanical equivalent circuit, the sandwich piezoelectric transducer with adjustable resonance frequency is studied. The underlying theory of frequency adjustment is its piezoelectric effect. In this paper, the influence of electric load impedance (including electric resistance, electric inductance, and electric capacitance) on the resonance frequency, the antiresonance frequency, and the effective electromechanical coupling coefficient is analyzed theoretically and experimentally. It is demonstrated that the electric load impedance can change the resonance frequency, the antiresonance frequency, and the effective electromechanical coupling coefficient. When the electric load resistance is increased, the resonance frequency and the antiresonance frequency are increased; the effective electromechanical coupling coefficient has a maximum value when the electric load resistance changes. When the electric load resistance becomes large, the effect of the electric load resistance on the effective electromechanical coupling coefficient is negligible. When the electric load inductance is increased, the resonance frequency and the antiresonance frequency are decreased, whereas the effective electromechanical coupling coefficient is increased. When the electric load capacitance is increased, the resonance frequency, the antiresonance frequency, and the effective electromechanical coupling coefficient are all decreased. It should be noted that when the electric load impedance becomes large, the effect of the electric load impedance on the resonance frequency, the antiresonance frequency, and the effective electromechanical coupling coefficient of a sandwich piezoelectric transducer becomes negligible.
- 31 December 2003
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 115 (1) , 182-186
Optimization of the performance of the sandwich piezoelectric ultrasonic transducer
The resonance and antiresonance frequency, the effective electromechanical coupling coefficient, and the mechanical quality factor of a sandwich piezoelectric ultrasonic transducer are studied and optimized. The effect of the thickness of thick piezoelectric element electrodes on the transducer performance is analyzed. The effect of the length and position of the piezoelectric elements in the transducer is also studied. It is shown that, although using thick electrodes is beneficial for releasing heat produced by the piezoelectric elements, the effective electromechanical coupling coefficient and the mechanical quality factor are reduced. The length and the position of the piezoelectric elements affect the performances of the transducer. Increasing the length of the piezoelectric elements decreases the mechanical quality factor, but the effective electromechanical coupling coefficient increases. When the length reaches a certain value, the effective electromechanical coupling coefficient reaches a maximum value. When the piezoelectric elements are located at the geometrical center or the displacement node, the effective electromechanical coupling coefficient and the mechanical quality factor are maximized.
- 31 December 2003
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 115 (1) , 182-186
Optimization of the performance of the sandwich piezoelectric ultrasonic transducer
The resonance and antiresonance frequency, the effective electromechanical coupling coefficient, and the mechanical quality factor of a sandwich piezoelectric ultrasonic transducer are studied and optimized. The effect of the thickness of thick piezoelectric element electrodes on the transducer performance is analyzed. The effect of the length and position of the piezoelectric elements in the transducer is also studied. It is shown that, although using thick electrodes is beneficial for releasing heat produced by the piezoelectric elements, the effective electromechanical coupling coefficient and the mechanical quality factor are reduced. The length and the position of the piezoelectric elements affect the performances of the transducer. Increasing the length of the piezoelectric elements decreases the mechanical quality factor, but the effective electromechanical coupling coefficient increases. When the length reaches a certain value, the effective electromechanical coupling coefficient reaches a maximum value. When the piezoelectric elements are located at the geometrical center or the displacement node, the effective electromechanical coupling coefficient and the mechanical quality factor are maximized.