David Alejandro Rodríguez-Valderrama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David Alejandro Rodríguez-Valderrama has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Juan Manuel Belman Flores
Grupo de Investigación IRSE, Departamento de Ingeniería Mecánica, División de Ingenierías, Campus Irapuato-Salamanca, Universidad de Guanajuato, Salamanca-Valle de Santiago km. 3.5+1.8, Salamanca C.P. 36885, Guanajuato, Mexico
3 shared publications - Diana Pardo-Cely
Universidad de Guanajuato
2 shared publications - Donato Hernández-Fusilier
Department of Electronic Engineering, Engineering Division, Campus Irapuato-Salamanca, University of Guanajuato, Salamanca-Valle de Santiago km 3.5 + 1.8, Salamanca 36885, Mexico
2 shared publications - Juan Jose Garcia Pabon
Universidade Federal de Itajubá
2 shared publications - Ivan Hernández Pérez
División Académica de Ingeniería y Arquitectura, Universidad Juárez Autónoma de Tabasco
1 shared publication - Miguel A. Gomez-Martinez
Department of Electrical Engineering, University of Guanajuato, Salamanca 36787, Mexico
1 shared publication
Latest Publications
- Open Access
- 30 April 2024
- Published by MDPI AG in Clean Technologies
- Vol. 6 (2) , 528-550
Intelligent Control Based on Usage Habits in a Domestic Refrigerator with Variable Speed Compressor for Energy-Saving
Maintaining adequate temperatures for preserving food in a domestic refrigerator is a task that is affected by several factors, including the daily use of the appliance. In this sense, this work presents the development of a novel control system based on fuzzy logic that considers usage habits such as the amount of food entering the refrigerator and the frequency of opening doors. Thus, the control comprises input variables corresponding to the internal temperatures of both compartments, the thermal load entered, and the refrigerator door-opening signal. By simulating the usage habits of a refrigerator with a variable-speed compressor, the control performance was evaluated. The results showed that implementing fuzzy control using usage habits was robust enough to maintain adequate thermal conditions within the compartments and a lower thermal fluctuation concerning the reference control of the refrigerator (factory control). In terms of energy, the fuzzy control resulted in an energy saving of 3.20% with the refrigerator empty (without thermal load) compared to the reference control. On the other hand, the individual integration of the thermal load in the fuzzy control resulted in 2.08% energy savings and 5.45% for the integration of the thermal load compared to the reference control. Finally, considering the combination of usage habits, the fuzzy control presented a higher energy consumption than the reference control, around 9.7%. In this case, the fuzzy control maintained more favorable thermal conditions in both compartments, whereas the reference control presented a warmer thermal condition in the freezer.
- 30 April 2024
- Published by MDPI AG in Clean Technologies
- Vol. 6 (2) , 528-550
Open AccessIntelligent Control Based on Usage Habits in a Domestic Refrigerator with Variable Speed Compressor for Energy-Saving
Maintaining adequate temperatures for preserving food in a domestic refrigerator is a task that is affected by several factors, including the daily use of the appliance. In this sense, this work presents the development of a novel control system based on fuzzy logic that considers usage habits such as the amount of food entering the refrigerator and the frequency of opening doors. Thus, the control comprises input variables corresponding to the internal temperatures of both compartments, the thermal load entered, and the refrigerator door-opening signal. By simulating the usage habits of a refrigerator with a variable-speed compressor, the control performance was evaluated. The results showed that implementing fuzzy control using usage habits was robust enough to maintain adequate thermal conditions within the compartments and a lower thermal fluctuation concerning the reference control of the refrigerator (factory control). In terms of energy, the fuzzy control resulted in an energy saving of 3.20% with the refrigerator empty (without thermal load) compared to the reference control. On the other hand, the individual integration of the thermal load in the fuzzy control resulted in 2.08% energy savings and 5.45% for the integration of the thermal load compared to the reference control. Finally, considering the combination of usage habits, the fuzzy control presented a higher energy consumption than the reference control, around 9.7%. In this case, the fuzzy control maintained more favorable thermal conditions in both compartments, whereas the reference control presented a warmer thermal condition in the freezer.
- Open Access
- 26 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1302
A Review on Applications of Fuzzy Logic Control for Refrigeration Systems
The use of fuzzy logic controllers in refrigeration and air conditioning systems, RACs, has as main objective to maintain certain thermal and comfort conditions. In this sense, fuzzy controllers have proven to be a viable option for use in RACs due to their ease of implementation and their ability to integrate with other control systems and control improvements, as well as their ability to achieve potential energy savings. In this document, we present a review of the application of fuzzy controls in RACs based on vapor compression technology. Application information is discussed for each type of controller, according to its application in chillers, air conditioning systems, refrigerators, and heat pumps. In addition, this review provides detailed information on controller design, focusing on the potential to achieve energy savings; this design discusses input and output variables, number and type of membership functions, and inference rules. The future perspectives on the use of fuzzy control systems applied to RACs are shown as well. In other words, the information in this document is intended to serve as a guide for the creation of controller designs to be applied to RACs.
- 26 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1302
Open AccessA Review on Applications of Fuzzy Logic Control for Refrigeration Systems
The use of fuzzy logic controllers in refrigeration and air conditioning systems, RACs, has as main objective to maintain certain thermal and comfort conditions. In this sense, fuzzy controllers have proven to be a viable option for use in RACs due to their ease of implementation and their ability to integrate with other control systems and control improvements, as well as their ability to achieve potential energy savings. In this document, we present a review of the application of fuzzy controls in RACs based on vapor compression technology. Application information is discussed for each type of controller, according to its application in chillers, air conditioning systems, refrigerators, and heat pumps. In addition, this review provides detailed information on controller design, focusing on the potential to achieve energy savings; this design discusses input and output variables, number and type of membership functions, and inference rules. The future perspectives on the use of fuzzy control systems applied to RACs are shown as well. In other words, the information in this document is intended to serve as a guide for the creation of controller designs to be applied to RACs.
- Open Access
Thermal and Energy Evaluation of a Domestic Refrigerator under the Influence of the Thermal Load
This study seeks to understand the thermal and energetic behavior of a domestic refrigerator more widely by experimentally evaluating the main effects of the thermal load (food) and the variation of the ambient temperature. To carry out the experiments, the thermal load was classified based on the results of a survey conducted on different consumers in the state of Guanajuato, Mexico. The thermal behavior of both compartments of the refrigerator, the total energy consumption, the power of the compressor in its first on-state, and the coefficient of performance, according to the classification of the thermal loads and the room temperature, were evaluated. Finally, it is verified that the thermal load and the room temperature have a significant influence on the energy performance of the refrigerator.
Open AccessThermal and Energy Evaluation of a Domestic Refrigerator under the Influence of the Thermal Load
This study seeks to understand the thermal and energetic behavior of a domestic refrigerator more widely by experimentally evaluating the main effects of the thermal load (food) and the variation of the ambient temperature. To carry out the experiments, the thermal load was classified based on the results of a survey conducted on different consumers in the state of Guanajuato, Mexico. The thermal behavior of both compartments of the refrigerator, the total energy consumption, the power of the compressor in its first on-state, and the coefficient of performance, according to the classification of the thermal loads and the room temperature, were evaluated. Finally, it is verified that the thermal load and the room temperature have a significant influence on the energy performance of the refrigerator.