Xiangyu Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiangyu Chen has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Haiyun Yuan
Department of Cardiovascular Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, 510080 Guangzhou, Guangdong, China
3 shared publications - Qifei Jian
School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou, GuangDong, China
3 shared publications - Jiawei Liu
School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510640, Guangdong, China
2 shared publications - Meiping Huang
Department of Catheterization Lab, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China
2 shared publications - Neichuan Zhang
School of Mechanical and Automotive Engineering, South China University of Technology, Guangzhou 510640, Guangdong, China
2 shared publications Chengbin Zhou
Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Department of Cardiovascular Surgery, Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute, Guangdong Academy of Medical Sciences, Guangzhou, 510000, China
1 shared publication
Latest Publications
- 18 February 2020
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 11 (3) , 268-282
Hemodynamic Effects of Additional Pulmonary Blood Flow on Glenn and Fontan Circulation
Purpose Additional pulmonary blood flow (APBF) can provide better pulsating blood flow and systemic arterial oxygen saturation, while low blood pulsation and low oxygen saturation are defects of the Fontan and Glenn procedure. Studying the hemodynamic effect of APBF is beneficial for clinical decisions. This study aimed to explore the effect on particle washout, as well as the differences among the sensitivities of both different hemodynamic parameters and different procedures to APBF. Methods The patient-specific clinical datasets of a patient who underwent bilateral bidirectional Glenn (BBDG) with APBF were enrolled in this study, and using these datasets, Glenn- and Fontan-type artery models were reconstructed. A series of parameters, including the total caval flow pulsatility index (TCPI), indexed energy loss (iPL), wall shear stress (WSS), systemic arterial oxygen saturation (Satart), particle washout time (WOT), pressure in the right superior vena cava (PRSVC), pulmonary flow distribution (PFD) and hepatic flow distribution (HFD), were computed from computational fluid dynamic (CFD) simulation to evaluate the hemodynamic effect of APBF. Results The result showed that APBF led to better iPL and Satart but worse PRSVC and heart load accompanied by a great impact on HFD, making hepatic flow easier to perfuse the side without MPA and APBF. The increase in the APBF rate also effectively results in larger flow pulsation, region velocity, and wall shear stress and lower WOT, and this effect may be more effective for patients with persistent left superior vena cava (PLSVC). However, APBF might have little effect on PFD. Furthermore, APBF might affect WOT, iPL and HFD more significantly than PRSVC and has a greater improvement effect in patients with poorer iPL and WOT. Conclusions Moderate APBF is not only a measure to promote pulmonary artery growth and systemic arterial oxygen saturation but also an effective method against endothelial dysfunction and thrombosis. However, moderate APBF is patient-specific and should be determined based on hemodynamic preference that leads to desired patient outcomes, and care should be taken to prevent PRSVC and heart load from being too high as well as an imbalance in HFD.
- 18 February 2020
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 11 (3) , 268-282
Hemodynamic Effects of Additional Pulmonary Blood Flow on Glenn and Fontan Circulation
Purpose Additional pulmonary blood flow (APBF) can provide better pulsating blood flow and systemic arterial oxygen saturation, while low blood pulsation and low oxygen saturation are defects of the Fontan and Glenn procedure. Studying the hemodynamic effect of APBF is beneficial for clinical decisions. This study aimed to explore the effect on particle washout, as well as the differences among the sensitivities of both different hemodynamic parameters and different procedures to APBF. Methods The patient-specific clinical datasets of a patient who underwent bilateral bidirectional Glenn (BBDG) with APBF were enrolled in this study, and using these datasets, Glenn- and Fontan-type artery models were reconstructed. A series of parameters, including the total caval flow pulsatility index (TCPI), indexed energy loss (iPL), wall shear stress (WSS), systemic arterial oxygen saturation (Satart), particle washout time (WOT), pressure in the right superior vena cava (PRSVC), pulmonary flow distribution (PFD) and hepatic flow distribution (HFD), were computed from computational fluid dynamic (CFD) simulation to evaluate the hemodynamic effect of APBF. Results The result showed that APBF led to better iPL and Satart but worse PRSVC and heart load accompanied by a great impact on HFD, making hepatic flow easier to perfuse the side without MPA and APBF. The increase in the APBF rate also effectively results in larger flow pulsation, region velocity, and wall shear stress and lower WOT, and this effect may be more effective for patients with persistent left superior vena cava (PLSVC). However, APBF might have little effect on PFD. Furthermore, APBF might affect WOT, iPL and HFD more significantly than PRSVC and has a greater improvement effect in patients with poorer iPL and WOT. Conclusions Moderate APBF is not only a measure to promote pulmonary artery growth and systemic arterial oxygen saturation but also an effective method against endothelial dysfunction and thrombosis. However, moderate APBF is patient-specific and should be determined based on hemodynamic preference that leads to desired patient outcomes, and care should be taken to prevent PRSVC and heart load from being too high as well as an imbalance in HFD.
- Open Access
- 14 February 2020
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2020, 1-11
3D Simulation Analysis of Central Shunt in Patient-Specific Hemodynamics: Effects of Varying Degree of Pulmonary Artery Stenosis and Shunt Diameters
The objective of this study was to compare the effects of different shunt diameters and pulmonary artery (PA) stenosis grades on the hemodynamics of central shunts to determine an optimal surgical plan and improve the long-term outcomes of the operation. A 3D anatomical model was reconstructed based on the patient’s clinical CT data. 3D computational fluid dynamics models were built with varying degrees of stenosis (the stenosis ratio α was represented by the ratio of blood flow through the main pulmonary artery to cardiac output, ranging from 0 to 30%; the smaller the value of α, the more severe the pulmonary artery stenosis) and varying shunt diameters (3, 3.5, 4, 4.5, and 5 mm). Our results show that the asymmetry of pulmonary artery flow increased with increasing shunt diameter and α, which will be more conducive to the development of the left pulmonary artery. Additionally, the pulmonary-to-systemic flow ratio (QP/QS) increases with the shunt diameter and α, and all the values exceed 1. When the shunt diameter is 3 mm and α = 0%, QP/QS reaches the minimum value of 1.01, and the oxygen delivery reaches the maximum value of 205.19 ml/min. However, increasing shunt diameter and α is beneficial to reduced power loss and smoother PA flow. In short, for patients with severe PA stenosis (α is small), a larger-diameter shunt may be preferred. Conversely, when the degree of PA stenosis is moderate, a smaller shunt diameter can be considered.
- 14 February 2020
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2020, 1-11
Open Access3D Simulation Analysis of Central Shunt in Patient-Specific Hemodynamics: Effects of Varying Degree of Pulmonary Artery Stenosis and Shunt Diameters
The objective of this study was to compare the effects of different shunt diameters and pulmonary artery (PA) stenosis grades on the hemodynamics of central shunts to determine an optimal surgical plan and improve the long-term outcomes of the operation. A 3D anatomical model was reconstructed based on the patient’s clinical CT data. 3D computational fluid dynamics models were built with varying degrees of stenosis (the stenosis ratio α was represented by the ratio of blood flow through the main pulmonary artery to cardiac output, ranging from 0 to 30%; the smaller the value of α, the more severe the pulmonary artery stenosis) and varying shunt diameters (3, 3.5, 4, 4.5, and 5 mm). Our results show that the asymmetry of pulmonary artery flow increased with increasing shunt diameter and α, which will be more conducive to the development of the left pulmonary artery. Additionally, the pulmonary-to-systemic flow ratio (QP/QS) increases with the shunt diameter and α, and all the values exceed 1. When the shunt diameter is 3 mm and α = 0%, QP/QS reaches the minimum value of 1.01, and the oxygen delivery reaches the maximum value of 205.19 ml/min. However, increasing shunt diameter and α is beneficial to reduced power loss and smoother PA flow. In short, for patients with severe PA stenosis (α is small), a larger-diameter shunt may be preferred. Conversely, when the degree of PA stenosis is moderate, a smaller shunt diameter can be considered.
- Open Access
- 3 February 2019
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2019, 1-10
Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation
Studying the haemodynamics of the central shunt (CS) and modified Blalock–Taussig shunt (MBTS) benefits the improvement of postoperative recovery for patients with an aorta-pulmonary shunt. Shunt configurations, including CS and MBTS, are virtually reconstructed for infants A and B based on preoperative CT data, and three-dimensional models of A, 11 months after CS, and B, 8 months after MBTS, are reconstructed based on postoperative CT data. A series of parameters including energy loss, wall shear stress, and shunt ratio are computed from simulation to analyse the haemodynamics of CS and MBTS. Our results showed that the shunt ratio of the CS is approximately 30% higher than the MBTS and velocity distribution in the left pulmonary artery (LPA) and right pulmonary artery (RPA) was closer to a natural development in the CS than the MBTS. However, energy loss of the MBTS is lower, and the MBTS can provide more symmetric pulmonary artery (PA) flow than the CS. With the growth of infants A and B, the shunt ratio of infants was decreased, but maximum wall shear stress and the distribution region of high wall shear stress (WSS) were increased, which raises the probability of thrombosis. For infant A, the preoperative abnormal PA structure directly resulted in asymmetric growth of PA after operation, and the LPA/RPA ratio decreased from 0.49 to 0.25. Insufficient reserved length of the MBTS led to traction phenomena with the growth of infant B; on the one hand, it increased the eddy current, and on the other hand, it increased the flow resistance of anastomosis, promoting asymmetric PA flow.
- 3 February 2019
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2019, 1-10
Open AccessComputational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation
Studying the haemodynamics of the central shunt (CS) and modified Blalock–Taussig shunt (MBTS) benefits the improvement of postoperative recovery for patients with an aorta-pulmonary shunt. Shunt configurations, including CS and MBTS, are virtually reconstructed for infants A and B based on preoperative CT data, and three-dimensional models of A, 11 months after CS, and B, 8 months after MBTS, are reconstructed based on postoperative CT data. A series of parameters including energy loss, wall shear stress, and shunt ratio are computed from simulation to analyse the haemodynamics of CS and MBTS. Our results showed that the shunt ratio of the CS is approximately 30% higher than the MBTS and velocity distribution in the left pulmonary artery (LPA) and right pulmonary artery (RPA) was closer to a natural development in the CS than the MBTS. However, energy loss of the MBTS is lower, and the MBTS can provide more symmetric pulmonary artery (PA) flow than the CS. With the growth of infants A and B, the shunt ratio of infants was decreased, but maximum wall shear stress and the distribution region of high wall shear stress (WSS) were increased, which raises the probability of thrombosis. For infant A, the preoperative abnormal PA structure directly resulted in asymmetric growth of PA after operation, and the LPA/RPA ratio decreased from 0.49 to 0.25. Insufficient reserved length of the MBTS led to traction phenomena with the growth of infant B; on the one hand, it increased the eddy current, and on the other hand, it increased the flow resistance of anastomosis, promoting asymmetric PA flow.