Kanming Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kanming Wang has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Hongyu Wang
College of Environment, Zhejiang University of Technology, Hangzhou 310014, China
6 shared publications - Bruce Jefferson
Cranfield University, College Road, Cranfield, Bedfordshire, MK43 0AL, UK
5 shared publications - Ewan James McAdam
Cranfield Water Science Institute, Cranfield University, MK43 0AL, UK
5 shared publications - Ana Soares
Cranfield Water Science Institute Cranfield University Cranfield Bedfordshire UK
3 shared publications Hongyu Wang
3 shared publications- Ji Shu
College of Environment, Zhejiang University of Technology, Hangzhou 310014, China
2 shared publications
Latest Publications
- 29 July 2024
- Published by Elsevier in Bioresource Technology
- Vol. 408, 131174
Enhanced methane production from anaerobic digestion of waste activated sludge with weak magnetic field: Insights into performances and mechanisms
- 29 July 2024
- Published by Elsevier in Bioresource Technology
- Vol. 408, 131174
Enhanced methane production from anaerobic digestion of waste activated sludge with weak magnetic field: Insights into performances and mechanisms
- Open Access
Biochar Addition in Membrane Bioreactor Enables Membrane Fouling Alleviation and Nitrogen Removal Improvement for Low C/N Municipal Wastewater Treatment
Membrane bioreactors (MBRs) are frequently used to treat municipal wastewater, but membrane fouling is still the main weakness of this technology. Additionally, the low carbon-nitrogen (C/N) ratio influent has been shown to not only increase the membrane fouling, but also introduce challenges to meet the effluent discharge standard for nitrogen removal. Herein, the authors addressed the challenges by adding cost-effective biochar. The results suggested that the biochar addition can enable membrane fouling alleviation and nitrogen removal improvement. The reduced membrane fouling can be ascribed to the biochar adsorption capacity, which facilitates to form bigger flocs with carbon skeleton in biochar as a core. As a result, the biochar addition significantly altered the mixed liquor suspension with soluble microbial product (SMP) concentration reduction of approximately 14%, lower SMP protein/polysaccharide ratio from 0.28 ± 0.02 to 0.22 ± 0.03, smaller SMP molecular weight and bigger sludge particle size from 67.68 ± 6.9 μm to 113.47 ± 4.8 μm. The nitrogen removal is also dramatically improved after biochar addition, which can be due to the initial carbon source release from biochar, and formation of aerobic–anaerobic microstructures. Microbial diversity analysis results suggested more accumulation of denitrification microbes including norank_f__JG30-KF-CM45 and Plasticicumulans. Less relative abundance of Aeromonas after biochar addition suggested less extracellular polymer substance (EPS) secretion and lower membrane fouling rate.
Open AccessBiochar Addition in Membrane Bioreactor Enables Membrane Fouling Alleviation and Nitrogen Removal Improvement for Low C/N Municipal Wastewater Treatment
Membrane bioreactors (MBRs) are frequently used to treat municipal wastewater, but membrane fouling is still the main weakness of this technology. Additionally, the low carbon-nitrogen (C/N) ratio influent has been shown to not only increase the membrane fouling, but also introduce challenges to meet the effluent discharge standard for nitrogen removal. Herein, the authors addressed the challenges by adding cost-effective biochar. The results suggested that the biochar addition can enable membrane fouling alleviation and nitrogen removal improvement. The reduced membrane fouling can be ascribed to the biochar adsorption capacity, which facilitates to form bigger flocs with carbon skeleton in biochar as a core. As a result, the biochar addition significantly altered the mixed liquor suspension with soluble microbial product (SMP) concentration reduction of approximately 14%, lower SMP protein/polysaccharide ratio from 0.28 ± 0.02 to 0.22 ± 0.03, smaller SMP molecular weight and bigger sludge particle size from 67.68 ± 6.9 μm to 113.47 ± 4.8 μm. The nitrogen removal is also dramatically improved after biochar addition, which can be due to the initial carbon source release from biochar, and formation of aerobic–anaerobic microstructures. Microbial diversity analysis results suggested more accumulation of denitrification microbes including norank_f__JG30-KF-CM45 and Plasticicumulans. Less relative abundance of Aeromonas after biochar addition suggested less extracellular polymer substance (EPS) secretion and lower membrane fouling rate.
- 25 August 2021
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 7 (11) , 2021-2032
Membrane fouling amelioration through pseudo dead-end filtration coupled with transmembrane pressure (TMP) set-point control in an anaerobic membrane bioreactor for municipal wastewater treatment
In this study, a novel gas sparging regime was applied, in which filtration was conducted without gas sparging to create a pseudo dead-end (DE) filtration cycle followed by membrane relaxation/backwashing for a short period of time with gas sparging until the TMP set-point was achieved. Compared with conventional continuous filtration and continuous gas sparging (CGS) modes and temporal pseudo DE filtration modes, this pseudo DE filtration coupled with TMP set-point control mode can achieve lower energy demand with sustainable membrane operation. The impacts of the TMP set-point value, imposed flux and physical cleaning process (membrane relaxation/backwash coupled with gas sparging) were evaluated. The result indicated that a moderate TMP set-point value (10–12 kPa) should be selected. Backwashing can significantly reduce the irreversible fouling and enhance the net permeate flux. However, when the TMP set-point value was higher (TMPset = 14 kPa), severe cake layer consolidation occurred and no appreciable improvement of fouling control was observed even with backwashing coupled with gas sparging. The optimum condition can be established when the TMP set-point value was 12 kPa at a flux of 15 L m−2 h−1 in terms of a higher net flux and lower specific energy demand. Importantly, sustainable membrane operation can be achieved under pseudo DE filtration coupled with TMP set-point control mode with a low energy demand (0.09 kWh m−3) and low operational cost ($0.027 per m3), promoting energy neutral municipal wastewater treatment to be realized.
- 25 August 2021
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 7 (11) , 2021-2032
Membrane fouling amelioration through pseudo dead-end filtration coupled with transmembrane pressure (TMP) set-point control in an anaerobic membrane bioreactor for municipal wastewater treatment
In this study, a novel gas sparging regime was applied, in which filtration was conducted without gas sparging to create a pseudo dead-end (DE) filtration cycle followed by membrane relaxation/backwashing for a short period of time with gas sparging until the TMP set-point was achieved. Compared with conventional continuous filtration and continuous gas sparging (CGS) modes and temporal pseudo DE filtration modes, this pseudo DE filtration coupled with TMP set-point control mode can achieve lower energy demand with sustainable membrane operation. The impacts of the TMP set-point value, imposed flux and physical cleaning process (membrane relaxation/backwash coupled with gas sparging) were evaluated. The result indicated that a moderate TMP set-point value (10–12 kPa) should be selected. Backwashing can significantly reduce the irreversible fouling and enhance the net permeate flux. However, when the TMP set-point value was higher (TMPset = 14 kPa), severe cake layer consolidation occurred and no appreciable improvement of fouling control was observed even with backwashing coupled with gas sparging. The optimum condition can be established when the TMP set-point value was 12 kPa at a flux of 15 L m−2 h−1 in terms of a higher net flux and lower specific energy demand. Importantly, sustainable membrane operation can be achieved under pseudo DE filtration coupled with TMP set-point control mode with a low energy demand (0.09 kWh m−3) and low operational cost ($0.027 per m3), promoting energy neutral municipal wastewater treatment to be realized.
- 1 February 2020
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 384, 121458
Efficient electrochemical generation of ferrate(VI) by iron coil anode imposed with square alternating current and treatment of antibiotics
- 1 February 2020
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 384, 121458
Efficient electrochemical generation of ferrate(VI) by iron coil anode imposed with square alternating current and treatment of antibiotics