FBFrédéric Begnaud

Frédéric Begnaud

*This is an algorithmically generated author record based on publicly available information.

Frédéric Begnaud has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Mass Spectrometry: An Essential Tool for the Flavor and Fragrance Industry

    by Frédéric Begnaud

    Over the past decades, mass spectrometers have become standard instruments in the analytical laboratories of the flavor and fragrance (F&F) industry. As the expansion of the fields of use of flavors and fragrances and the launch of numerous new technologies designed to enhance their performance have led to a diversification and increased complexity of the questions asked to the analytical chemists, mass spectrometry remains an essential tool to address them. The capabilities of the latest generation of instruments combined with advanced molecular separation and data processing tools allow to tackle many of these challenges. Through different examples, and focusing on the period that followed our 2014 review [1], this article illustrates different ways MS is contributing to the discovery development and commercialization of F&F ingredients and technologies, for both volatile and non-volatile molecules.


  • In Vitro Biotransformation Assays Using Liver S9 Fractions and Hepatocytes from Rainbow Trout (Oncorhynchus mykiss): Overcoming Challenges with Difficult to Test Fragrance Chemicals

    by Christian Kropf, Frédéric Begnaud, Sylvia Gimeno, Fabienne Berthaud, Christian Debonneville, Helmut Segner

    In vitro metabolic stability assays using rainbow trout (Oncorhynchus mykiss) isolated hepatocytes (RT‐HEP) or hepatic S9 fractions (RT‐S9) were introduced to provide biotransformation rate data for the assessment of chemical bioaccumulation in fish. The present study explored the suitability of the RT‐HEP and RT‐S9 assays for difficult test chemicals, and the in vitro–based predictions were compared to in silico–based predictions and in vivo–measured bioconcentration factors (BCFs). The results show that volatile or reactive chemicals can be tested with minor modifications of the in vitro protocols. For hydrophobic chemicals, a passive dosing technique was developed. Finally, a design‐of‐experiment approach was used to identify optimal in vitro assay conditions. The modified assay protocols were applied to 10 fragrances with diverse physicochemical properties. The in vitro intrinsic clearance rates were higher in the S9 than in the hepatocyte assay, but the in vitro–in vivo (IVIV) predictions were comparable between the 2 assays. The IVIV predictions classified the test chemicals as nonbioaccumulative (BCF < 2000), which was in agreement with the in vivo data but in contrast to the in silico–based predictions. The findings from the present study provide strong evidence that the RT‐HEP and RT‐S9 assays can provide reliable estimates of in vivo biotransformation rates for test chemicals with difficult physicochemical properties. Environ Toxicol Chem 2020;00:1–13. © 2020 SETAC


  • Open Access

    Quantification of Residual Perfume by Py-GC-MS in Fragrance Encapsulate Polymeric Materials Intended for Biodegradation Tests

    by Giulio Gasparini, Sarah Semaoui, Jessica Augugliaro, Alain Boschung, Damien Berthier, Markus Seyfried, Frédéric Begnaud

    Perfume encapsulates are widely used in commercial products to control the kinetic release of odorant molecules, increase storage stability and/or improve deposition on different substrates. In most of the cases, they consist of core-shell polymeric microcapsules that contain fragrance molecules. A current challenge is to design and produce polymeric materials for encapsulation that are both resistant and non-persistent. The selection of such eco-friendly formulations is linked to a deep understanding of the polymeric material used for encapsulation and its biodegradation profile. To collect this information, pure samples of capsule shells are needed. In this article we present an innovative quantification method for residual volatiles based on pyrolysis-GC-MS to enable validation of sample quality prior to further testing. The presented analytical method also led to the development of a robust and comprehensive purification protocol for polymers from commercial samples. Standard techniques are not suited for this kind of measurement due to the non-covalent embedding of volatiles in the 3D structure of the polymers. We demonstrated the confounding impact of residual volatiles on the estimated biodegradability of fragrance encapsulates.


  • Intestinal Fish Cell Barrier Model to Assess Transfer of Organic Chemicals in Vitro: An Experimental and Computational Study

    by Hannah Schug, Jenny Maner, Frédéric Begnaud, Fabienne Berthaud, Sylvia Gimeno, Kristin Schirmer, Anže Županič

    We studied the role of the fish intestine as a barrier for organic chemicals using the epithelial barrier model built on the rainbow trout (Oncorhynchus mykiss) intestinal cell line, RTgutGC and the newly developed exposure chamber, TransFEr, specifically designed to work with hydrophobic and volatile chemicals. Testing 11 chemicals with a range of physico-chemical properties (logKOW: 2.2 to 6.3, logHLC: 6.1 to 2.3) and combining the data with a mechanistic kinetic model enabled the determination of dominant processes underlying the transfer experiments and the derivation of robust transfer rates. Against the current assumption in chemical uptake modelling, chemical transfer did not strictly depend on the logKOW but resulted from chemical-specific intracellular accumulation and biotransformation combined with paracellular and active transport. Modelling also identified that conducting elaborate measurements of the plastic parts, including the polystyrene insert and the PET filter, is unnecessary and that stirring in the TransFEr chamber reduced the stagnant water layers compared to theoretical predictions. Aside from providing insights into chemical uptake via the intestinal epithelium, this system can easily be transferred to other cell-based barrier systems, such as the fish gill or mammalian intestinal models and may improve in vitro-in vivo extrapolation and prediction of chemical bioaccumulation into organisms.


  • From the Representativeness of Sampled Odors to an Olfactive Camera

    by Alain Chaintreau, Urs Keller, Barbara Zellner, Kelly Nguy, Sabine Leocata, Frédéric Begnaud

    Although representativeness is often a prerequisite when sampling odors, the methods used have never been assessed from the analytical and the sensory perspective simultaneously. We validate several critical innovations in the methods used to sample odors, starting with a previously developed static-and-trapped headspace (S&T-HS) cell, to minimize sorptive biases and allow thermodesorption of trapped odors. The addition of a desorption oven allows restoration and testing of odors sampled not only by S&T-HS, but also by other techniques (solid-phase microextraction, HS sorptive extract, purge-and-trap HS). The S&T-HS cell exhibits satisfactory representativeness, much higher than the other three techniques. This allows, for the first time, a proposal to use this technology as an olfactive camera to capture and restore an odor. The method was tested on a sample of a complex fresh ashtray odor.


  • TransFEr: a new device to measure the transfer of volatile and hydrophobic organic chemicals across anin vitrointestinal fish cell barrier

    by Hannah Schug, Frédéric Begnaud, Christian Debonneville, Fabienne Berthaud, Sylvia Gimeno, Kristin Schirmer

    Transfer of compounds across cellular barriers is a critical step of compound uptake into organisms. Using in vitro barrier systems to evaluate such transfer is attractive because of the higher throughput and reduced resource needs compared to animal studies. Thus far, however, studying the transfer of hydrophobic and volatile compounds was hampered by the unavailability of in vitro exposure systems that allow for stable and predictable chemical exposure concentrations. To overcome this limitation, we constructed a novel exposure chamber, TransFEr, and tested it with an in vitro epithelial barrier model using the rainbow trout (Oncorhynchus mykiss) intestinal cell line, RTgutGC. Key features of the chamber are its closed design and rotatable silicon segments, which can serve for chemical dosing and sampling. Using the fragrance damascone beta (log KOW: 3.7, log HLC: −3.9) as a pilot chemical, we were able to demonstrate that our exposure chamber provides for stable chemical exposure concentrations and full mass balance. The RTgutGC epithelium served as barrier for damascone beta transfer, which we attribute to chemical retention and biotransformation in the intestinal cells. Nevertheless, substantial transfer of the chemical across the epithelium occurred. When a chemical sink, i.e. a silicon segment, was included in the basolateral chamber to mimic blood constituents binding in vivo, transfer was about three-fold enhanced. We suggest that the presented methodology can help to obtain insights into chemical uptake mechanisms via the intestinal or other epithelia of fish and other animals for hydrophobic and volatile chemicals.


  • Open Access

    Good quantification practices of flavours and fragrances by mass spectrometry

    by Frédéric Begnaud, Alain Chaintreau

    Over the past 15 years, chromatographic techniques with mass spectrometric detection have been increasingly used to monitor the rapidly expanded list of regulated flavour and fragrance ingredients. This trend entails a need for good quantification practices suitable for complex media, especially for multi-analytes. In this article, we present experimental precautions needed to perform the analyses and ways to process the data according to the most recent approaches. This notably includes the identification of analytes during their quantification and method validation, when applied to real matrices, based on accuracy profiles. A brief survey of application studies based on such practices is given.This article is part of the themed issue ‘Quantitative mass spectrometry’.


  • Limits of rapid log P determination methods for highly lipophilic and flexible compounds

    by Sophie Martel, Frédéric Begnaud, William Schuler, Fabrice Gillerat, Nils Oberhauser, Alessandra Nurisso, Pierre-Alain Carrupt


  • LogP measurement of a highly hydrophobic properfume: evaluation of extrapolation of RP‐HPLC results and impact of chemical moieties on accuracy

    by F. Begnaud, J.‐P. Larcinese, P. Fankhauser, U. Maddalena

    The n‐octanol/water partition coefficient (LogP) of a chemical substance is a key parameter for assessing its potential (eco)‐toxicological effects and environmental fate. To measure the LogP of properfume Haloscent®D (expected LogP > 9), no direct measurement technique can be applied and the reliability of in silico models is impaired by the absence of robust datasets in the high LogP range. Indirect method using reversed‐phase‐HPLC (RP‐HPLC) is promising but we demonstrate that the lack of suitable standards lead to significant discrepancy and poor accuracy.Extrapolation of the correlation between the RP‐HPLC retention factor (logk) of low‐carbon chain homologues and their LogP measured by slow‐stir method has been studied. To select the most suitable standards, the impact of specific moiety representative of Haloscent®D (linear alkyl chain, delta‐damascone moiety, thioether function) on the logk vs. estimated LogP has been checked on different molecules and it was demonstrated that the alkyl chain had the most impact on this correlation. The stability in the molecular conformation of Haloscent®D homologue series was also verified to ensure that no folding occurred as from a certain alkyl chain length, and that consequently extrapolation is feasible up to Haloscent®D. Accuracy of the extrapolated LogP value was calculated from the prediction interval of the logk vs. LogP regression. The LogP of the Haloscent®D was concluded to be 9.7 ± 0.5. Copyright © 2016 John Wiley & Sons, Ltd.


  • Extraction, thermal cleanup, and GC/MS quantification with disposable solid extractants: Application to hydrophobic analytes in aqueous surfactant solutions

    by Frédéric Begnaud, Christian Debonneville, Alain Chaintreau

    Fragranced consumer products are generally formulated together with surfactants. In application, these products are often highly diluted with water. Analyzing trace amounts of fragrance ingredients in such mixtures is challenging and usually requires either time‐consuming sample cleanup or extensive cleaning of the trapping device to avoid memory effect and cross‐contamination between samples. To overcome these limitations, a new disposable extraction device has been developed to be used in combination with a thermodesorption–GC–MS unit. Made of PDMS foam cylinders, it efficiently extracts trace amounts of hydrophobic compounds from complex aqueous solutions and provides an online sample cleanup, thanks to the controlled desorption temperature, which allows retaining the low volatile constituents of the matrix within the absorptive foam. Combined with a stable isotope dilution assay, accurate quantifications of Cetalox®, Muscenone™, Helvetolide®, Polysantol®, Dartanol, and Myrrhone® from aqueous solution containing surfactant and from water from the aeration tank of a sewage plant were successfully conducted. LOQ varied between 1 and 25 ppb (20% confidence interval, α=0.1).