CKChristine Kern

Christine Kern

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christine Kern has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Orbi‐SIMS Mediated Metabolomics Analysis of Pathogenic Tissue up to Cellular Resolution

    by Christine Kern, Astrid Scherer, Laura Gambs, Mariia Yuneva, Henning Walczak, Gianmaria Liccardi, Julia Saggau, Peter Kreuzaler, Marcus Rohnke

    Tumors have a complex metabolism that differs from most metabolic processes in healthy tissues. It is highly dynamic and driven by the tumor cells themselves, as well as by the non‐transformed stromal infiltrates and immune components. Each of these cell populations has a distinct metabolism that depends on both their cellular state and the availability of nutrients. Consequently, to fully understand the individual metabolic states of all tumor‐forming cells, correlative mass spectrometric imaging (MSI) up to cellular resolution with minimal metabolite shift needs to be achieved. By using a secondary ion mass spectrometer (SIMS) equipped with an Orbitrap mass analyzer, we present a workflow to image primary murine tumor tissues up to cellular resolution and correlate these ion images with post acquisition immunofluorescence or histological staining. In a murine breast cancer model, we could identify metabolic profiles that clearly distinguish tumor tissue from stromal cells and immune infiltrates. We demonstrate the robustness of the classification by applying the same profiles to an independent murine model of lung cancer, which is accurately segmented by histological traits. Our pipeline allows metabolic segmentation with simultaneous cell identification, which in the future will enable the design of subpopulation‐targeted metabolic interventions for therapeutic purposes.


  • Open Access

    Influence of Moisture on the Electrochemical Performance of Prelithiated Graphite/SiOx Composite Anodes for Li-Ion Batteries

    by Hans Fenske, Teo Lombardo, Jessica Gerstenberg, Christine Kern, Dominik Steckermeier, Peter Michalowski, Jürgen Janek, Arno Kwade

    Prelithiation is widely recognized as a promising technology to enable the use of high capacity anode active materials such as silicon. Numerous prelithiation techniques have been proposed over the years, with a handful successfully undergoing pilot scale testing. Nevertheless, new challenges arise when moving from optimizing single processes to integrating them into the process chain. A major concern is the stability of prelithiated electrodes against moisture. In this study, we investigate the influence of industrially-relevant moisture levels on the electrochemical performance of prelithiated graphite/SiOx composite anodes in 3-electrode half- and full-cells. We identify several indicators of electrode degradation such as an increase in open circuit potential, a decrease in graphite lithiation potential, and changes in specific charge/discharge capacity. The underlying degradation mechanisms are examined using electrochemical impedance spectroscopy, X-ray photoelectron spectroscopy, and time-of-flight secondary ion mass spectrometry, which show increased solid electrolyte interphase (SEI)-related interfacial resistances but no clear evidence of SEI degradation. Based on the experimental results, we define a process window for the stability of the investigated electrodes as a function of dew point and exposure time. Our results indicate an encouragingly high stability at dew points up to −40 °C for a realistic exposure time of 1 h.


  • Open Access

    Bridging the Gap: Electrode Microstructure and Interphase Characterization by Combining ToF‐SIMS and Machine Learning

    by Teo Lombardo, Christine Kern, Joachim Sann, Marcus Rohnke, Jürgen Janek

    This article presents a new analytical methodology to analyze large (hundreds of µm) battery electrode microstructures by mapping the spatial distribution of the main phases (e.g., active material and carbon‐binder domain) and degradation products (solid‐ or cathode‐electrolyte interphase) formed during cycling. The methodology can be used for a better understanding of the relationships between electrode architecture and degradation, paving the way toward the analysis of interphases spatial distribution and their correlations to the electrode formulation, microstructure, and cycling conditions. This work is based on time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS), and focuses on analyzing large 2D electrode cross‐sections at both the microstructure and single particle/agglomerate level. It also shows that this analysis can be expanded to 3D electrode microstructures when combining ToF‐SIMS and devoted machine learning procedures, which can be of particular interest to the 3D electrochemical modeling community.


  • Open Access

    ToF-SIMS in battery research: Advantages, limitations, and best practices

    by Teo Lombardo, Felix Walther, Christine Kern, Yannik Moryson, Timo Weintraut, Anja Henss, Marcus Rohnke

    Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful analytical technique whose application has great potential for battery research and that today is not used at its full potential. The goal of this article is to encourage battery researchers to add ToF-SIMS to their research toolbox and to incite ToF-SIMS experts to collaborate more strongly with battery researchers. It is, therefore, addressed to both new and experienced ToF-SIMS operators. First, an introduction to the analysis technique is given, in which the fundamental operating principle and the most common measurement modes are briefly explained. Additionally, we provide information on different machines commercially available. Based on this knowledge, we discuss the suitability of ToF-SIMS for battery research and highlight its method-specific characteristics for corresponding analytical tasks. We show that the high sensitivity of this analytical method (fractions < 10 ppm are detectable) combined with high flexibility for all analyzable materials (organic, inorganic, and hybrid) and sample formats (powders, thin films, electrodes, etc.) make ToF-SIMS particularly relevant for battery research, where the chemical nature of interfaces/interphases and traces of reaction products are of paramount importance. As practical guidance, we introduce and discuss the most common pitfalls when using ToF-SIMS for battery research and give hints on how they could be avoided or minimized. A major goal of this article is to review best practices, focusing on improving data quality, avoiding artifacts, and improving reproducibility.


  • Open Access

    Secondary ion mass spectrometry for bone research

    by Christine Kern, Stefanie Kern, Anja Henss, Marcus Rohnke

    The purpose of this Tutorial is to highlight the suitability of time-of-flight secondary ion mass spectrometry (ToF-SIMS) and OrbiTrap™ SIMS (Orbi-SIMS) in bone research by introducing fundamentals and best practices of bone analysis with these mass spectrometric imaging (MSI) techniques. The Tutorial includes sample preparation, determination of best-suited measurement settings, data acquisition, and data evaluation, as well as a brief overview of SIMS applications in bone research in the current literature. SIMS is a powerful analytical technique that allows simultaneous analysis and visualization of mineralized and nonmineralized bone tissue, bone marrow as well as implanted biomaterials, and interfaces between bone and implants. Compared to histological staining, which is the standard analytical procedure in bone research, SIMS provides chemical imaging of nonstained bone sections that offers insights beyond what is conventionally obtained. The Tutorial highlights the versatility of ToF- and Orbi-SIMS in addressing important questions in bone research. By illustrating the value of these MSI techniques, it demonstrates how they can contribute to advance progress in bone research.


  • Open Access

    Characterisation of Sr2+mobility in osteoporotic rat bone marrow by cryo-ToF-SIMS and cryo-OrbiSIMS

    by Christine Kern, Reem Jamous, Thaqif El Khassawna, Marcus Rohnke

    Mass spectrometric imaging approach forex vivomonitoring of drug transport in bone sections. Cryo-ToF-SIMS depth profiling and high-resolution imaging as well as OrbiSIMS analysis revealed inhomogeneous Sr2+transport in rat bone marrow.


  • Open Access

    Determination of Sr 2+ mobility in viscous bovine bone marrow by cryo‐time‐of‐flight secondary ion mass spectrometry

    by Christine Kern, Anna Pauli, Marcus Rohnke

    Rationale: In osteoporosis research, strontium ions (Sr 2+ ) have emerged as promising therapeutic agent in modified bone cements for better fracture healing. Modeling of Sr 2+ dispersion in bone could be used as a predictive tool for the evaluation of functionalized biomaterials in future. Therefore, determination of experimental parameters for Sr 2+ transport in bone is essential. In this study, we focus on the determination of Sr 2+ diffusion in viscous bovine bone marrow by time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS). Methods: For this comparatively fast diffusion (FD) experiment, a specific experimental protocol of ToF‐SIMS depth profiling under cryogenic conditions was developed. The validity of our experimental approach is proven by a time‐dependent experimental series. Furthermore, 2D and 3D mass spectrometric imaging analysis was used to study Sr 2+ surface and bulk distribution within bovine bone marrow. Results: Detailed 2D and 3D mass spectrometric imaging analysis revealed that Sr 2+ diffusion is slower in bone marrow areas with high intensity of lipid and fatty acid signals than in areas with less lipid content. The Sr 2+ transport within this passive model can be described by Fickian diffusion. Average diffusion coefficients of Sr 2+ in bovine bone marrow were obtained from diffusion profiles in FD areas ( D bovine,FD = [2.09 ± 2.39]·10 −9 cm 2 s −1 ), slow diffusion areas ( D bovine,SD = [1.52 ± 1.80]·10 −10 cm 2 s −1 ), and total area diffusion ( D bovine,TA = [1.94 ± 2.40]·10 −9 cm 2 s −1 ). Conclusions: We were able to show that cryo‐ToF‐SIMS is a useful tool for the characterization of rapid diffusion in water‐containing highly viscous media. To the best of our knowledge, this is the first reported experimental approach for the investigation of the distribution of low concentrated therapeutic agents in bone marrow. Overall, our results provide important insights about Sr 2+ diffusion in bovine bone marrow.


  • Open Access

    New insights into ToF-SIMS imaging in osteoporotic bone research

    by Christine Kern, Seemun Ray, Michael Gelinsky, Allen T. Bellew, Alexander Pirkl, Marcus Rohnke

    The present work focuses on the application of time-of-flight secondary ion mass spectrometry (ToF-SIMS) in osteoporotic bone research. In order to demonstrate the benefit, the authors present concrete application examples of ToF-SIMS in three different areas of bone research. ToF-SIMS as a mass spectrometric imaging technique allows simultaneous visualization of mineralized and nonmineralized bone tissue as well as implanted biomaterials and bone implant interphases. In the first example, the authors show that it is possible to study the incorporation and distribution of different components released from bone filler materials into bone with a single mass spectrometric measurement. This not only enables imaging of nonstained bone cross sections but also provides further insights beyond histologically obtained information. Furthermore, they successfully identified several mass fragments as markers for newly formed cartilage tissue and growth joint in bone. Different modes of ToF-SIMS as well as different SIMS instruments (IONTOF's TOF.SIMS 5 and M6 Hybrid SIMS, Ionoptika's J105) were used to identify these mass signals and highlight the high versatility of this method. In the third part, bone structure of cortical rat bone was investigated from bone sections embedded in technovit (polymethyl methacrylate, PMMA) and compared to cryosections. In cortical bone, they were able to image different morphological features, e.g., concentric arrangement of collagen fibers in so-called osteons as well as Haversian canals and osteocytes. In summary, the study provides examples of application and shows the strength of ToF-SIMS as a promising analytical method in the field of osteoporotic bone research.


  • Investigation of strontium transport and strontium quantification in cortical rat bone by time-of-flight secondary ion mass spectrometry

    by Christine Kern, Mandy Quade, Seemun Ray, Jürgen Thomas, Matthias Schumacher, Thomas Gemming, Michael Gelinsky, Volker Alt, Marcus Rohnke

    Next-generation bone implants will be functionalized with drugs for stimulating bone growth. Modelling of drug release by such functionalized biomaterials and drug dispersion into bone can be used as predicting tool for biomaterials testing in future. Therefore, the determination of experimental parameters to describe and simulate drug release in bone is essential. Here, we focus on Sr2+transport and quantification in cortical rat bone. Sr2+dose-dependently stimulates bone-building osteoblasts and inhibits bone-resorbing osteoclasts. It should be preferentially applied in the case of bone fracture in the context of osteoporotic bone status. Transport properties of cortical rat bone were investigated by dipping experiments of bone sections in aqueous Sr2+solution followed by time-of-flight secondary ion mass spectrometry (ToF-SIMS) depth profiling. Data evaluation was carried out by fitting a suitable mathematical diffusion equation to the experimental data. An average diffusion coefficient ofD= (1.68 ± 0.57) · 10−13cm2s−1for healthy cortical bone was obtained. This value differed only slightly from the value ofD= (4.30 ± 1.43) · 10−13cm2s−1for osteoporotic cortical bone. Transmission electron microscopy investigations revealed a comparable nano- and ultrastructure for both types of bone status. Additionally, Sr2+-enriched mineralized collagen standards were prepared for ToF-SIMS quantification of Sr2+content. The obtained calibration curve was used for Sr2+quantification in cortical and trabecular bone in real bone sections. The results allow important insights regarding the Sr2+transport properties in healthy and osteoporotic bone and can ultimately be used to perform a simulation of drug release and mobility in bone.