MPMalgorzata Polacin

Malgorzata Polacin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Malgorzata Polacin has a total of 40 co-authors. Here are the top co-authors by number of shared publications:

  • Hatem Alkadhi

    Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland

    4 shared publications
  • Robert Manka

    Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland

    4 shared publications
  • Hatem Alkadhi

    Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland

    3 shared publications
  • Ioannis Matziris

    Department of Cardiology, University Heart Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland

    3 shared publications
  • Matthias Eberhard

    Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland

    3 shared publications
  • Mihaly Karolyi

    Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland

    3 shared publications

Latest Publications

  • Open Access

    Photon-Counting Detector CT Angiography for Endoleak Detection After Endovascular Aortic Repair

    by Ana Maria Turrion Gomollon, Victor Mergen, Thomas Mmed Sartoretti, Malgorzata Md Polacin, Dominik Nakhostin, Gilbert Puippe, Hatem Alkadhi, André Euler

    Objectives: The aim of this study was to compare image quality and endoleak detection after endovascular abdominal aortic aneurysm repair between a triphasic computed tomography (CT) with true noncontrast (TNC) and a biphasic CT with virtual noniodine (VNI) images on photon-counting detector CT (PCD-CT). Materials and Methods: Adult patients after endovascular abdominal aortic aneurysm repair who received a triphasic examination (TNC, arterial, venous phase) on a PCD-CT between August 2021 and July 2022 were retrospectively included. Endoleak detection was evaluated by 2 blinded radiologists on 2 different readout sets (triphasic CT with TNC-arterial-venous vs biphasic CT with VNI-arterial-venous). Virtual noniodine images were reconstructed from the venous phase. The radiologic report with additional confirmation by an expert reader served as reference standard for endoleak presence. Sensitivity, specificity, and interreader agreement (Krippendorf α) were calculated. Image noise was assessed subjectively in patients using a 5-point scale and objectively calculating the noise power spectrum in a phantom. Results: One hundred ten patients (7 women; age, 76 ± 8 years) with 41 endoleaks were included. Endoleak detection was comparable between both readout sets with a sensitivity and specificity of 0.95/0.84 (TNC) versus 0.95/0.86 (VNI) for reader 1 and 0.88/0.98 (TNC) versus 0.88/0.94 (VNI) for reader 2. Interreader agreement for endoleak detection was substantial (TNC: 0.716, VNI: 0.756). Subjective image noise was comparable between TNC and VNI (4; IQR [4, 5] vs 4; IQR [4, 5], P = 0.44). In the phantom, noise power spectrum peak spatial frequency was similar between TNC and VNI (both fpeak = 0.16 mm−1). Objective image noise was higher in TNC (12.7 HU) as compared with VNI (11.5 HU). Conclusions: Endoleak detection and image quality were comparable using VNI images in biphasic CT as compared with TNC images in triphasic CT offering the possibility to reduce scan phases and radiation exposure.


  • Open Access

    Impact of Photon Counting Detector CT Derived Virtual Monoenergetic Images on the Diagnosis of Pulmonary Embolism

    by Tetyana Yalynska, Malgorzata Polacin, Thomas Frauenfelder, Katharina Martini

    Purpose: To assess the impact of virtual-monoenergetic-image (VMI) energies on the diagnosis of pulmonary embolism (PE) in photon-counting-detector computed-tomography (PCD-CT). Methods: Eighty patients (median age 60.4 years) with suspected PE were retrospectively included. Scans were performed on PCD-CT in the multi-energy mode at 120 kV. VMIs from 40–70 keV in 10 keV intervals were reconstructed. CT-attenuation was measured in the pulmonary trunk and the main branches of the pulmonary artery. Signal-to-noise (SNR) ratio was calculated. Two radiologists evaluated subjective-image-quality (noise, vessel-attenuation and sharpness; five-point-Likert-scale, non-diagnostic–excellent), the presence of hardening artefacts and presence/visibility of PE. Results: Signal was highest at the lowest evaluated VMI (40 keV; 1053.50 HU); image noise was lowest at the highest VMI (70 keV; 15.60 HU). Highest SNR was achieved at the lowest VMI (p < 0.05). Inter-reader-agreement for subjective analysis was fair to excellent (k = 0.373–1.000; p < 0.001). Scores for vessel-attenuation and sharpness were highest at 40 keV (both:5, range 4/3–5; k = 1.000); scores for image-noise were highest at 70 keV (4, range 3–5). The highest number of hardening artifacts were reported at 40 keV (n = 22; 28%). PE-visualization was rated best at 50 keV (4.7; range 4–5) and decreased with increasing VMI-energy (r = −0.558; p < 0.001). Conclusions: While SNR was best at 40 keV, subjective PE visibility was rated highest at 50 keV, potentially owing to the lower image noise and hardening artefacts.


  • Open Access

    Quantitative evaluation of aortic valve regurgitation in 4D flow cardiac magnetic resonance: at which level should we measure?

    by Malgorzata Polacin, Julia Geiger, Barbara Burkhardt, Fraser M. Callaghan, Emanuela Valsangiacomo, Christian Kellenberger

    To find the best level to measure aortic flow for quantification of aortic regurgitation (AR) in 4D flow CMR. In 27 congenital heart disease patients with AR (67% male, 31 ± 16 years) two blinded observers measured antegrade, retrograde, net aortic flow volumes and regurgitant fractions at 6 levels in 4D flow: (1) below the aortic valve (AV), (2) at the AV, (3) at the aortic sinus, (4) at the sinotubular junction, (5) at the level of the pulmonary arteries (PA) and (6) below the brachiocephalic trunk. 2D phase contrast (2DPC) sequences were acquired at the level of PA. All patients received prior transthoracic echocardiography (TTE) with AR severity grading according to a recommended multiparametric approach. After assigning 2DPC measurements into AR grading, agreement between TTE AR grading and 2DPC was good (κ = 0.88). In 4D flow, antegrade flow was similar between the six levels (p = 0.87). Net flow was higher at level 1–2 than at levels 3–6 (p < 0.05). Retrograde flow and regurgitant fraction at level 1–2 were lower compared to levels 3–6 (p < 0.05). Reproducibility (inter-reader agreement: ICC 0.993, 95% CI 0.986–0.99; intra-reader agreement: ICC 0.982, 95%CI 0.943–0.994) as well as measurement agreement between 4D flow and 2DPC (ICC 0.994; 95%CI 0.989 – 0.998) was best at the level of PA. For estimating severity of AR in 4D flow, best reproducibility along with best agreement with 2DPC measurements can be expected at the level of PA. Measurements at AV or below AV might underestimate AR.


  • Open Access

    Segmental strain for scar detection in acute myocardial infarcts and in follow-up exams using non-contrast CMR cine sequences

    by Malgorzata Polacin, Mihaly Karolyi, Matthias Eberhard, Ioannis Matziris, Hatem Alkadhi, Sebastian Kozerke, Robert Manka

    Background: The purpose of the study was to investigate feasibility of infarct detection in segmental strain derived from non-contrast cardiac magnetic resonance (CMR) cine sequences in patients with acute myocardial infarction (AMI) and in follow-up (FU) exams. Methods: 57 patients with AMI (mean age 61 ± 12 years, CMR 2.8 ± 2 days after infarction) were retrospectively included, FU exams were available in 32 patients (35 ± 14 days after first CMR). 43 patients with normal CMR (54 ± 11 years) served as controls. Dedicated software (Segment CMR, Medviso) was used to calculate global and segmental strain derived from cine sequences. Cine short axis stacks and segmental circumferential strain calculations of every patient and control were presented to two blinded readers in random order, who were advised to identify potentially infarcted segments, blinded to LGE and clinical information. Results: Impaired global strain was measured in AMI patients compared to controls (global peak circumferential strain [GPCS] p = 0.01; global peak longitudinal strain [GPLS] p = 0.04; global peak radial strain [GPRS] p = 0.01). In both imaging time points, mean segmental peak circumferential strain [SPCS] was impaired in infarcted tissue compared to remote segments (AMI: p = 0.03, FU: p = 0.02). SPCS values in infarcted segments were similar between AMI and FU (p = 0.8). In SPCS calculations, 141 from 189 acutely infarcted segments were accurately detected (74.6%), visual evaluation of correlating cine images detected 43.4% infarcts. In FU, 80% infarcted segments (91/114 segments) were detected in SPCS and 51.8% by visual evaluation of correlating short axis cine images (p = 0.01). Conclusion: Segmental circumferential strain derived from routinely acquired native cine sequences detects nearly 75% of acute infarcts and 80% of infarcts in subacute follow-up CMR, significantly more than visual evaluation of correlating cine images alone. Acute infarcts may display only subtle impairment of wall motion and no obvious wall thinning, thus SPCS calculation might be helpful for scar detection in patients with acute infarcts, when LGE images are not available.


  • Simplified image acquisition and detection of ischemic and non-ischemic myocardial fibrosis with fixed short inversion time magnetic resonance late gadolinium enhancement

    by Malgorzata Polacin, Mihaly Karolyi, Christian Blüthgen, Nik Pilz, Matthias Eberhard, Hatem Alkadhi, Sebastian Kozerke, Robert Manka

    Objectives: Late gadolinium enhancement with fixed short inversion time (LGEshort) provides excellent tissue contrast with dark scar and bright blood pool and does not need prior myocardial nulling. We hypothesize better visibility of ischemic scars and equal visibility of non-ischemic LGE in LGEshortcompared to clinically established LGE (LGEstandard).Methods: LGEshortand LGEstandardwere retrospectively evaluated in 179 patients (3043 segments) with suspected or known coronary artery disease by four blinded readers (reader A: most experienced - D: least experienced). The amount of ischemic and non-ischemic LGE as well as visibility (4: very good – 1: poor) of ischemic LGE was visually assessed.Results: All readers detected more infarcted segments in LGEshortcompared to LGEstandard(378 segments reported as infarcted; A:p = 0.5, B:p = 0.8, C,D:p = 0.03). Scar visibility was scored higher in LGEshortby all readers (A,B:p = 0.03; C,D:p = 0.02), especially for subendocardial infarcts (A,B:p = 0.04, C,D:p = 0.02). Less experienced readers detected significantly more infarcted papillary muscles (C:p = 0.02, D:p = 0.03) in a shorter reading time in LGEshort(C:p = 0.04, D:p = 0.02). Non-ischemic LGE was equally visible in both sequences (A:p = 0.9, B:p = 0.8, C,D:p = 0.6).Conclusions: LGEshortdetects more ischemic LGE with improved scar visibility compared to LGEstandard, independent of experience level. The visibility of non-ischemic LGE is equivalent to LGEstandard. Less experienced readers can diagnose ischemic and non-ischemic LGE faster in LGEshort.Advances in knowledge: LGEshortwith its maximal operational simplicity can be used for visualization of all types of fibrosis – ischemic and non-ischemic – instead of LGEstandard, independent of experience level.


  • Open Access

    Photon-counting computed tomography for the diagnosis of myocardial infarction with non-obstructive coronary artery disease

    by Malgorzata Polacin, Christian Templin, Robert Manka, Hatem Alkadhi

    A 61-year-old male with acute chest pain was referred with suspicion of acute coronary syndrome. Blood troponin T (high sensitive) was elevated (100 ng/L, norm S1). Invasive coronary angiography revealed left coronary dominance with irregularities of the left anterior descending artery (LAD), but no significant stenosis or culprit lesion (Panel A). Echocardiography was normal, showing no regional wall motion abnormalities. ECG-gated computed tomography (CT) was performed using first-generation dual-source photon-counting detector CT for ruling-out pulmonary embolism and acute aortic syndrome. CT showed mild coronary calcifications (Agatston score 39) and confirmed absent obstructive coronary artery disease (PanelB). In addition, hypodense myocardium was detected in the midventricular inferolateral wall (PanelC). Dual-energy derived iodine maps from photon-counting CT overlaid onto coronary CT angiography images confirmed the area with reduced iodine concentration (PanelsD and E), yielding a reduced normalized iodine content (11.3% and 10.5% in the corresponding segments, compared to 14.3% and 12.9% in the LAD and CX territory, respectively; PanelF). Cardiac magnetic resonance imaging confirmed normal global (ejection fraction 62%) and regional left ventricular function (Video 1) and demonstrated a small ischaemic, transmural scar in the midventricular inferolateral wall in late gadolinium enhancement and native T1 maps (PanelsG–I), corresponding to the findings from photon-counting CT. Thus, myocardial infarction with non-obstructive coronary artery disease was the most probable diagnosis.


  • Open Access

    Segmental Strain for Scar Detection in Acute Myocardial Infarcts and in Follow-up Exams using Non-Contrast CMR Cine Sequences

    by Malgorzata Polacin, Mihaly Karolyi, Matthias Eberhard, Ioannis Matziris, Hatem Alkadhi, Sebastian Kozerke, Robert Manka

    Background The purpose of the study was to investigate feasibility of infarct detection in segmental strain derived from non-contrast cardiac magnetic resonance (CMR) cine sequences in patients with acute myocardial infarction (AMI) and in follow-up (FU) exams.Methods57 patients with AMI (mean age 61 ± 12 years, CMR 2.8 ± 2 days after infarction) were retrospectively included, FU exams were available in 32 patients (35 ± 14 days after first CMR). 28 patients with normal CMR (47 ± 8 years) served as controls. Dedicated software (Segment CMR, Medviso) was used to calculate global and segmental strain derived from cine sequences. Cine short axis stacks and segmental circumferential strain calculations of every patient and control were presented to two blinded readers in random order, who were advised to identify potentially infarcted segments, blinded to LGE and clinical information. Results Impaired global strain was measured in AMI patients compared to controls (global peak circumferential strain [GPCS] p= 0.01; global peak longitudinal strain [GPLS] p= 0.04; global peak radial strain [GPRS] p= 0.01). In both imaging time points, mean segmental peak circumferential strain [SPCS] was impaired in infarcted tissue compared to remote segments (AMI: p=0.03, FU: p=0.02). SPCS values in infarcted segments were similar between AMI and FU (p=0.8), remote segments were marginally more impaired in AMI than in FU (p= 0.07). In SPCS calculations, 141 from 189 acutely infarcted segments were accurately detected (74.6%), visual evaluation of correlating cine images detected 44.4% infarcts. In FU, 81.5 % infarcted segments (93/114 segments) were detected in SPCS and 51.8% by visual evaluation of correlating short axis cine images (p=0.01).ConclusionSegmental circumferential strain derived from routinely acquired native cine sequences detects nearly 75 % of acute infarcts and about 80% of infarcts in subacute follow-up CMR, significantly more than visual evaluation of correlating cine images alone. Acute infarcts may display only subtle impairment of wall motion and no obvious wall thinning, thus SPCS calculation might be helpful for scar detection in patients with acute infarcts, when only cine images are available.

  • Open Access

    Segmental Strain for Myocardial Scar Detection in Acute Infarcts and Follow-Up CMR Using Non-Contrast Cine Images

    by Malgorzata Polacin, Mihaly Karolyi, Matthias Eberhard, Alexander Gotschy, Ioannis Matziris, Hatem Alkadhi, Sebastian Kozerke, Robert Manka

    Aims Scar tissue from myocardial infarction is best visualized with cardiac magnetic resonance (CMR) late gadolinium enhancement (LGE). Gadolinium-free alternatives for detection of myocardial scars are limited. This study investigated the feasibility of myocardial scar detection in acute infarcts and follow-up CMR using non-contrast cine images. Methods Fifty-seven patients with acute infarcts (15 female, mean age 61 ± 12 years, CMR 2.8 ± 2 days after infarction) were retrospectively evaluated with follow-up CMR exams available in thirty-two patients (9 female, 35 ± 14 days after infarction). Twenty-eight patients with normal CMR scans (2 female, mean age 47 ± 8 years) served as controls. Global and segmental strain parameters (global peak circumferential [GPCS], global peak longitudinal [GPLS], global peak radial strain [GPRS], segmental peak circumferential [SPCS], segmental peak longitudinal [SPLS], and segmental peak radial strain [SPRS]) were calculated from standard non-contrast balanced SSFP cine sequences using commercially available software (Segment CMR, Medviso, Sweden). Visual assessment of wall motion abnormalities on short axis cine images, as well as segmental circumferential strain calculations (endo-/epicardially contoured short axis cine and resulting polar plot strain map) of every patient (acute imaging and follow-up CMR) and control were presented for two blinded readers in random order, who were advised to localize potentially infarcted segments, blinded to LGE images and clinical information.Results While global strain values were impaired in patients with acute infarcts compared to controls (GPCS p= 0.01; GPLS p= 0.04; GPRS p= 0.01), global strain was similar between first CMR and follow-up imaging in the subgroup of 32 patients (GPCS p= 0.7; GPLS p=0.8; GPRS p=0.2). In acute infarcts and in follow-up CMR, patients had reduced mean SPCS in infarcted segments compared to remote myocardium (acute p= 0.03, follow-up exams p= 0.02). SPCS values in infarcted areas were similar in acute infarcts and in follow-up exams (p=0.8). In acute infarcts 74.6% of all in LGE infarcted segments (141/189) were correctly localized in polar plot strain maps compared to 44.4% (84/189) of infarcted segments detected by visual wall motion assessment only (p < 0.01). In follow-up exams, 81.5% of all in LGE infarcted segments (93/114 segments) were correctly localized in polar plot strain maps compared to 51.8% (59/114) of infarcted segments detected by visual wall motion assessment (p < 0.01).Conclusion Segmental circumferential strain derived from routinely acquired cine sequences detects nearly 75% acute infarcts and about 80% of infarcts in follow-up CMR and can potentially be used for scar identification based on non-contrast cine images, when gadolinium cant not be applied or LGE images are not available.

  • Open Access

    3D whole heart imaging in severe funnel chest and non-compaction cardiomyopathy

    by M. Polacin, P. Biaggi, H. Alkadhi, S. Kozerke, R. Manka


  • Open Access

    Cardiovascular magnetic resonance T2* mapping for structural alterations in hypertrophic cardiomyopathy

    by Mareike Gastl, Alexander Gotschy, Jochen von Spiczak, Malgorzata Polacin, Florian Bönner, Christiane Gruner, Malte Kelm, Frank Ruschitzka, Hatem Alkadhi, Sebastian Kozerke, et al.