Roberto Adrian Markarian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Roberto Adrian Markarian has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Cristiane Ueda
MSc Program, Department of Prosthodontics, University of São Paulo School of Dentistry, Brazil
2 shared publicationsDalva Cruz Laganá
Professor, Department of Prosthodontics, University of São Paulo School of Dentistry, Brazil
2 shared publicationsAlessandro Dourado Loguercio
Universidade de São Paulo
1 shared publicationCarolina P. Duarte
1 shared publicationClaudio L. Sendyk
1 shared publicationClaudio Luiz Sendyk
Professor, Department of Prosthodontics, University of São Paulo School of Dentistry, Brazil
1 shared publication
Latest Publications
- 1 September 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 128 (3) , 450-457
Dental implant-abutment fracture resistance and wear induced by single-unit screw-retained CAD components fabricated by four CAM methods after mechanical cycling
- 1 September 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 128 (3) , 450-457
Dental implant-abutment fracture resistance and wear induced by single-unit screw-retained CAD components fabricated by four CAM methods after mechanical cycling
- Open Access
- 2 February 2019
- Published by Wiley in Clinical Case Reports
- Vol. 7 (3) , 500-505
Model‐less digital workflow for the replication of an existing complete fixed implant‐supported prosthesis using an intraoral scanner
Key Clinical Message: The use of an intraoral scanner was efficient to produce a full‐contour zirconia CAFIP, with improved esthetics when compared to the original prosthesis.
- 2 February 2019
- Published by Wiley in Clinical Case Reports
- Vol. 7 (3) , 500-505
Open AccessModel‐less digital workflow for the replication of an existing complete fixed implant‐supported prosthesis using an intraoral scanner
Key Clinical Message: The use of an intraoral scanner was efficient to produce a full‐contour zirconia CAFIP, with improved esthetics when compared to the original prosthesis.
- 1 January 2018
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 33 (1) , 127-136
Scanning Electron Microscopy Analysis of the Adaptation of Single-Unit Screw-Retained Computer-Aided Design/Computer-Aided Manufacture Abutments After Mechanical Cycling
Roberto Adrian Markarian, DDS, MS, PhD/Deborah Pedroso Galles, DVM, MS/Fabiana Mantovani Gomes Fran?a, DS, MS, PhD: Purpose: To measure the microgap between dental implants and custom abutments fabricated using different computer-aided design/computer-aided manufacture (CAD/CAM) methods before and after mechanical cycling. Materials and Methods: CAD software (Dental System, 3Shape) was used to design a custom abutment for a single-unit, screw-retained crown compatible with a 4.1-mm external hexagon dental implant. The resulting stereolithography file was sent for manufacturing using four CAD/CAM methods (n = 40): milling and sintering of zirconium dioxide (ZO group), cobalt-chromium (Co-Cr) sintered via selective laser melting (SLM group), fully sintered machined Co-Cr alloy (MM group), and machined and sintered agglutinated Co-Cr alloy powder (AM group). Prefabricated titanium abutments (TI group) were used as controls. Each abutment was placed on a dental implant measuring 4.1× 11 mm (SA411, SIN) inserted into an aluminum block. Measurements were taken using scanning electron microscopy (SEM) (×4,000) on four regions of the implant-abutment interface (IAI) and at a relative distance of 90 degrees from each other. The specimens were mechanically aged (1 million cycles, 2 Hz, 100 N, 37?C) and the IAI width was measured again using the same approach. Data were analyzed using two-way analysis of variance, followed by the Tukey test. Results: After mechanical cycling, the best adaptation results were obtained from the TI (2.29 ? 1.13 μm), AM (3.58 ? 1.80 μm), and MM (1.89 ? 0.98 μm) groups. A significantly worse adaptation outcome was observed for the SLM (18.40 ? 20.78 μm) and ZO (10.42 ? 0.80 μm) groups. Mechanical cycling had a marked effect only on the AM specimens, which significantly increased the microgap at the IAI. Conclusion: Custom abutments fabricated using fully sintered machined Co-Cr alloy and machined and sintered agglutinated Co-Cr alloy powder demonstrated the best adaptation results at the IAI, similar to those obtained with commercial prefabricated titanium abutments after mechanical cycling. The adaptation of custom abutments made by means of SLM or milling and sintering of zirconium dioxide were worse both before and after mechanical cycling.
- 1 January 2018
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 33 (1) , 127-136
Scanning Electron Microscopy Analysis of the Adaptation of Single-Unit Screw-Retained Computer-Aided Design/Computer-Aided Manufacture Abutments After Mechanical Cycling
Roberto Adrian Markarian, DDS, MS, PhD/Deborah Pedroso Galles, DVM, MS/Fabiana Mantovani Gomes Fran?a, DS, MS, PhD: Purpose: To measure the microgap between dental implants and custom abutments fabricated using different computer-aided design/computer-aided manufacture (CAD/CAM) methods before and after mechanical cycling. Materials and Methods: CAD software (Dental System, 3Shape) was used to design a custom abutment for a single-unit, screw-retained crown compatible with a 4.1-mm external hexagon dental implant. The resulting stereolithography file was sent for manufacturing using four CAD/CAM methods (n = 40): milling and sintering of zirconium dioxide (ZO group), cobalt-chromium (Co-Cr) sintered via selective laser melting (SLM group), fully sintered machined Co-Cr alloy (MM group), and machined and sintered agglutinated Co-Cr alloy powder (AM group). Prefabricated titanium abutments (TI group) were used as controls. Each abutment was placed on a dental implant measuring 4.1× 11 mm (SA411, SIN) inserted into an aluminum block. Measurements were taken using scanning electron microscopy (SEM) (×4,000) on four regions of the implant-abutment interface (IAI) and at a relative distance of 90 degrees from each other. The specimens were mechanically aged (1 million cycles, 2 Hz, 100 N, 37?C) and the IAI width was measured again using the same approach. Data were analyzed using two-way analysis of variance, followed by the Tukey test. Results: After mechanical cycling, the best adaptation results were obtained from the TI (2.29 ? 1.13 μm), AM (3.58 ? 1.80 μm), and MM (1.89 ? 0.98 μm) groups. A significantly worse adaptation outcome was observed for the SLM (18.40 ? 20.78 μm) and ZO (10.42 ? 0.80 μm) groups. Mechanical cycling had a marked effect only on the AM specimens, which significantly increased the microgap at the IAI. Conclusion: Custom abutments fabricated using fully sintered machined Co-Cr alloy and machined and sintered agglutinated Co-Cr alloy powder demonstrated the best adaptation results at the IAI, similar to those obtained with commercial prefabricated titanium abutments after mechanical cycling. The adaptation of custom abutments made by means of SLM or milling and sintering of zirconium dioxide were worse both before and after mechanical cycling.
- 16 October 2015
- Published by Universidade de São Paulo. Agência de Bibliotecas e Coleções Digitais
"Biomecânica da transmissão de cargas a implantes unitários em função dos materiais protéticos: análise fotoelástica e dinâmica"
Em próteses sobre implantes, o recobrimento oclusal com materiais pouco rígidos como os acrílicos, é por vezes utilizado por supostamente reduzir a carga transmitida ao osso, entretanto não existe um consenso...
- 16 October 2015
- Published by Universidade de São Paulo. Agência de Bibliotecas e Coleções Digitais
"Biomecânica da transmissão de cargas a implantes unitários em função dos materiais protéticos: análise fotoelástica e dinâmica"
Em próteses sobre implantes, o recobrimento oclusal com materiais pouco rígidos como os acrílicos, é por vezes utilizado por supostamente reduzir a carga transmitida ao osso, entretanto não existe um consenso...
- 14 March 2007
- Published by Wiley in Journal of Prosthodontics
- Vol. 16 (2) , 117-122
Stress Distribution after Installation of Fixed Frameworks with Marginal Gaps over Angled and Parallel Implants: A Photoelastic Analysis
The objective of this work was to compare by photoelastic analysis the stress distribution along a fixed framework placed over angled or parallel implants with different gap values between the framework and one of the implants. Two photoelastic models were created: (i) with parallel implants; (ii) with a 30 degrees angled central implant. In both cases, three implants were used, and CP titanium frameworks were constructed with commercial components. A plane polariscope was used to observe the photoelastic fringes generated after initial framework assembly, and also when an axial load of 100 N was applied over the central implant. For both models, stress analysis was conducted on well-fitting frameworks and on another with a 150 microm vertical gap between the framework and the central implant. The photoelastic analysis indicated that in the model with parallel implants, stress distribution followed the implant axis, and in the model with an angled implant, a higher and nonhomogeneous stress concentration was observed around the apical region of the lateral implants. The placement of an ill-fitting framework resulted in increased preload stress patterns. Stresses were generated after screw tightening of the frameworks, increasing when a load was applied and when a vertical gap was present. Angled implants resulted in oblique stress patterns, which were not transferred with homogeneity to the polymeric model.
- 14 March 2007
- Published by Wiley in Journal of Prosthodontics
- Vol. 16 (2) , 117-122
Stress Distribution after Installation of Fixed Frameworks with Marginal Gaps over Angled and Parallel Implants: A Photoelastic Analysis
The objective of this work was to compare by photoelastic analysis the stress distribution along a fixed framework placed over angled or parallel implants with different gap values between the framework and one of the implants. Two photoelastic models were created: (i) with parallel implants; (ii) with a 30 degrees angled central implant. In both cases, three implants were used, and CP titanium frameworks were constructed with commercial components. A plane polariscope was used to observe the photoelastic fringes generated after initial framework assembly, and also when an axial load of 100 N was applied over the central implant. For both models, stress analysis was conducted on well-fitting frameworks and on another with a 150 microm vertical gap between the framework and the central implant. The photoelastic analysis indicated that in the model with parallel implants, stress distribution followed the implant axis, and in the model with an angled implant, a higher and nonhomogeneous stress concentration was observed around the apical region of the lateral implants. The placement of an ill-fitting framework resulted in increased preload stress patterns. Stresses were generated after screw tightening of the frameworks, increasing when a load was applied and when a vertical gap was present. Angled implants resulted in oblique stress patterns, which were not transferred with homogeneity to the polymeric model.
- 1 July 2006
- Published by Elsevier in Archives of Oral Biology
- Vol. 51 (7) , 548-551
Swine teeth as potential substitutes for in vitro studies in tooth adhesion: A SEM observation
- 1 July 2006
- Published by Elsevier in Archives of Oral Biology
- Vol. 51 (7) , 548-551
Swine teeth as potential substitutes for in vitro studies in tooth adhesion: A SEM observation
- Open Access
- 1 March 2004
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 18 (1) , 45-52
Photoelastic analysis of stress distribution on parallel and angled implants after installation of fixed prostheses.
The longevity of implant-supported prosthetic rehabilitation depends largely on how the masticatory forces are transferred to the implants and surrounding bone. Anatomical conditions, bone morphology and aesthetics usually dictate implant placement in less than ideal positions for prosthetic rehabilitation and sometimes it is possible to find them with different inclinations. The purpose of this paper was to compare, through photoelastic analysis, the stress distribution in a fixed prosthesis with 3 parallel implants, to the stress distribution in the same prosthesis in the existence of an angled central implant. Two photoelastic resin models were made and a polariscope was used in the visualization of isochromatic fringes formed in the models when axial loads of 2 kg, 5 kg and 10 kg were applied to a unique central point of the prosthesis. The presence of inducted tensions (preloads) was observed in the models after applying torque to the retention screws. Preloads were intensified with the incidence of occlusal forces. In the parallel implants, the force dissipation followed the long axis. The angled implant had a smaller quantity of fringes and the stresses were located mostly around the apical region of the lateral implants.
- 1 March 2004
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 18 (1) , 45-52
Open AccessPhotoelastic analysis of stress distribution on parallel and angled implants after installation of fixed prostheses.
The longevity of implant-supported prosthetic rehabilitation depends largely on how the masticatory forces are transferred to the implants and surrounding bone. Anatomical conditions, bone morphology and aesthetics usually dictate implant placement in less than ideal positions for prosthetic rehabilitation and sometimes it is possible to find them with different inclinations. The purpose of this paper was to compare, through photoelastic analysis, the stress distribution in a fixed prosthesis with 3 parallel implants, to the stress distribution in the same prosthesis in the existence of an angled central implant. Two photoelastic resin models were made and a polariscope was used in the visualization of isochromatic fringes formed in the models when axial loads of 2 kg, 5 kg and 10 kg were applied to a unique central point of the prosthesis. The presence of inducted tensions (preloads) was observed in the models after applying torque to the retention screws. Preloads were intensified with the incidence of occlusal forces. In the parallel implants, the force dissipation followed the long axis. The angled implant had a smaller quantity of fringes and the stresses were located mostly around the apical region of the lateral implants.
- 1 May 2002
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 190 (1) , 186-189
External PIGE–PIXE measurements at the São Paulo 8UD tandem accelerator
- 1 May 2002
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 190 (1) , 186-189
External PIGE–PIXE measurements at the São Paulo 8UD tandem accelerator
- Open Access
- 1 December 2001
- Published by FapUNIFESP (SciELO) in Pesquisa Odontológica Brasileira
- Vol. 15 (4) , 341-347
Alteração dimensional de amálgama de prata e liga à base de gálio
As ligas de gálio surgiram como alternativa à problemática da toxicidade do mercúrio. Apresentam propriedades semelhantes às do amálgama, mas as pesquisas apontam duas características desfavoráveis: corrosão excessiva e grande magnitude de expansão de presa, podendo causar fraturas e rachaduras nas estruturas dentais. O objetivo foi avaliar in vitro a alteração dimensional durante 7 dias de uma liga de gálio (Galloy, SDI, Austrália), comparativamente com uma liga de amálgama contendo zinco (F-400, SDI, Austrália), em função do contato e/ou contaminação com solução salina (NaCl 0,9%) nos estágios iniciais da cristalização. As condições experimentais de armazenagem foram em: ambiente seco; armazenagem em solução salina e contaminação com solução salina durante a condensação. Para o amálgama, foi ainda estudada a condição de contaminação introduzida na cápsula durante a trituração e para a liga de gálio, a proteção com resina fluida durante as primeiras 24 h ou durante todo o experimento. Os corpos-de-prova foram mantidos à temperatura de 37ºC ± 1ºC e suas dimensões monitoradas a cada 24 h, durante sete dias. O contato da liga de gálio com a solução salina durante a condensação ou nas primeiras horas após a condensação desencadeou uma expansão significantemente maior que as outras condições experimentais ao fim dos 7 dias. A aplicação de uma resina fluida para proteger a superfície dos cilindros foi capaz de evitar o aumento da expansão provocado pela umidade superficial. O amálgama não apresentou alterações significantes em nenhuma das condições experimentais, exceto quando contaminado durante a trituração.
- 1 December 2001
- Published by FapUNIFESP (SciELO) in Pesquisa Odontológica Brasileira
- Vol. 15 (4) , 341-347
Open AccessAlteração dimensional de amálgama de prata e liga à base de gálio
As ligas de gálio surgiram como alternativa à problemática da toxicidade do mercúrio. Apresentam propriedades semelhantes às do amálgama, mas as pesquisas apontam duas características desfavoráveis: corrosão excessiva e grande magnitude de expansão de presa, podendo causar fraturas e rachaduras nas estruturas dentais. O objetivo foi avaliar in vitro a alteração dimensional durante 7 dias de uma liga de gálio (Galloy, SDI, Austrália), comparativamente com uma liga de amálgama contendo zinco (F-400, SDI, Austrália), em função do contato e/ou contaminação com solução salina (NaCl 0,9%) nos estágios iniciais da cristalização. As condições experimentais de armazenagem foram em: ambiente seco; armazenagem em solução salina e contaminação com solução salina durante a condensação. Para o amálgama, foi ainda estudada a condição de contaminação introduzida na cápsula durante a trituração e para a liga de gálio, a proteção com resina fluida durante as primeiras 24 h ou durante todo o experimento. Os corpos-de-prova foram mantidos à temperatura de 37ºC ± 1ºC e suas dimensões monitoradas a cada 24 h, durante sete dias. O contato da liga de gálio com a solução salina durante a condensação ou nas primeiras horas após a condensação desencadeou uma expansão significantemente maior que as outras condições experimentais ao fim dos 7 dias. A aplicação de uma resina fluida para proteger a superfície dos cilindros foi capaz de evitar o aumento da expansão provocado pela umidade superficial. O amálgama não apresentou alterações significantes em nenhuma das condições experimentais, exceto quando contaminado durante a trituração.