XXXizhen Xu

Xizhen Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xizhen Xu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Bin Du

    State Key Laboratory of Radio Frequency Heterogeneous Integration, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education/Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen, China

    1 shared publication
  • Fengchan Zhang

    Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China

    1 shared publication
  • Jun He

    Shenzhen University

    1 shared publication
  • Kuikui Guo

    Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China

    1 shared publication
  • Min Zhang

    Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province Shenzhen University Shenzhen P. R. China

    1 shared publication
  • Wei Huang

    Guangdong and Hong Kong Joint Research Centre for Optical Fibre Sensors, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China

    1 shared publication

Latest Publications

  • Open Access

    In-Fiber Collimator-Based Fabry-Perot Interferometer with Enhanced Vibration Sensitivity

    by Bin Du, Xizhen Xu, Jun He, Kuikui Guo, Wei Huang, Fengchan Zhang, Min Zhang, Yiping Wang

    A simple vibration sensor is proposed and demonstrated based on an optical fiber Fabry-Perot interferometer (FPI) with an in-fiber collimator. The device was fabricated by splicing a quarter-pitch graded index fiber (GIF) with a section of a hollow-core fiber (HCF) interposed between single mode fibers (SMFs). The static displacement sensitivity of the FPI with an in-fiber collimator was 5.17 × 10−4 μm−1, whereas the maximum static displacement sensitivity of the device without collimator was 1.73 × 10−4 μm−1. Moreover, the vibration sensitivity of the FPI with the collimator was 60.22 mV/g at 100 Hz, which was significantly higher than the sensitivity of the FPI without collimator (11.09 mV/g at 100 Hz). The proposed FPI with an in-fiber collimator also exhibited a vibration sensitivity nearly one order of magnitude higher than the device without the collimator at frequencies ranging from 40 to 200 Hz. This low-cost FPI sensor is highly-sensitive, robust and easy to fabricate. It could potentially be used for vibration monitoring in remote and harsh environments.