Takeshi Sano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Takeshi Sano has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
H Yano
Shikoku Electric Power Co., Inc., Electrical Engineering Group, Hydropower Department 2-5, Marunouchi, Takamatsu, 760-8573, Japan
1 shared publicationK Miyagawa
Waseda University, Faculty of Science and Engineering3-4-1, Okubo, Shinjuku-ku, Tokyo, 169-8555, Japan
1 shared publicationM Maekawa
Hitachi Mitsubishi Hydro Corporation3-2-1, Saiwai-cho, Hitachi, Ibaraki, 317-8511, Japan
1 shared publicationM Reclari
Research and Innovation Center, Mitsubishi Heavy Industries, Hyogo, Japan
1 shared publication- Martino Reclari
Mitsubishi Heavy Industries, Ltd., Research & Innovation Center, Hyogo Japan
1 shared publication N Okamoto
Shikoku Electric Power Co., Inc., Electrical Engineering Group, Hydropower Department 2-5, Marunouchi, Takamatsu, 760-8573, Japan
1 shared publication
Latest Publications
- Open Access
- 27 March 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 240 (6) , 062058
Investigation of internal flow pattern of a multiphase axial pump
Due to recent advances in computational techniques, single phase performances of pumps can be easily estimated using CFD. However, when the working fluid is a mixture of liquid and gas (multi-phase flow) computations may struggle to capture the more complex physical phenomena that occurs, and the precision of the prediction worsen as the gas volume fraction at pump inlet is increased. To provide reliable benchmark for the improvement of simulations, in this study we experimentally investigated the internal flow pattern of a multiphase pump using high speed camera and high frequency pressure measurements, so as to obtain the data of pressure distribution inside of impeller, or to obtain blade loading, for several gas concentration conditions. Unsteady phenomena were identified at low flow rate conditions, and an explanation of their nature has been attempted.
- 27 March 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 240 (6) , 062058
Open AccessInvestigation of internal flow pattern of a multiphase axial pump
Due to recent advances in computational techniques, single phase performances of pumps can be easily estimated using CFD. However, when the working fluid is a mixture of liquid and gas (multi-phase flow) computations may struggle to capture the more complex physical phenomena that occurs, and the precision of the prediction worsen as the gas volume fraction at pump inlet is increased. To provide reliable benchmark for the improvement of simulations, in this study we experimentally investigated the internal flow pattern of a multiphase pump using high speed camera and high frequency pressure measurements, so as to obtain the data of pressure distribution inside of impeller, or to obtain blade loading, for several gas concentration conditions. Unsteady phenomena were identified at low flow rate conditions, and an explanation of their nature has been attempted.
- Open Access
Experimental Investigation on Transient Pressure Characteristics in a Helico-Axial Multiphase Pump
In oil and gas exploitation, the multiphase pump is a vital piece of equipment to guarantee production with high efficiency and stable operation. The complicated pattern of multiphase flow in the multiphase pump affects the pump performance; for this reason, the multiphase performance and the inner flow should be sufficiently investigated. In the present work, a liquid-gas multiphase pump is designed and manufactured, and then tested in a specialized test rig to reveal the transient pressure characteristics of the multiphase pump. Results show that the dominant frequency under water and water-air conditions is the blade passing frequency, which is induced by the rotor stator interaction. In the downstream of the impeller, the pressure fluctuation is obviously weakened, because the splitter-blade design could improve the control ability of flow pattern in the downstream region. In comparison with water condition, the pressure fluctuation of water-air condition greatly increases, and the multiples of impeller rotating frequency are stimulated due to the movement and merging of air bubbles. Finally, the correlation of transient pressure and phase distribution in impeller is revealed by using a high-speed camera. With the gradual pressure rise from impeller inlet to outlet, the relative movement and separation of two phases induce violent pressure fluctuations.
Open AccessExperimental Investigation on Transient Pressure Characteristics in a Helico-Axial Multiphase Pump
In oil and gas exploitation, the multiphase pump is a vital piece of equipment to guarantee production with high efficiency and stable operation. The complicated pattern of multiphase flow in the multiphase pump affects the pump performance; for this reason, the multiphase performance and the inner flow should be sufficiently investigated. In the present work, a liquid-gas multiphase pump is designed and manufactured, and then tested in a specialized test rig to reveal the transient pressure characteristics of the multiphase pump. Results show that the dominant frequency under water and water-air conditions is the blade passing frequency, which is induced by the rotor stator interaction. In the downstream of the impeller, the pressure fluctuation is obviously weakened, because the splitter-blade design could improve the control ability of flow pattern in the downstream region. In comparison with water condition, the pressure fluctuation of water-air condition greatly increases, and the multiples of impeller rotating frequency are stimulated due to the movement and merging of air bubbles. Finally, the correlation of transient pressure and phase distribution in impeller is revealed by using a high-speed camera. With the gradual pressure rise from impeller inlet to outlet, the relative movement and separation of two phases induce violent pressure fluctuations.
- Open Access
- 26 November 2012
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 15 (2) , 022019
Investigation of flow pattern downstream of spiral grooved runner cone in pump-turbine
High amplitude of pressure fluctuation is observed in a draft tube of a hydraulic turbine and a pump-turbine, for the case of partial load operation. Several methods had been reported to mitigate the amplitude so far, such as, air or water injection to the draft tube, fins on the draft tube surface, or runner replacement with optimized velocity profile at runner exit. However, several problems for each method can be considered, such as, negative influence on efficiency, high cost, technical difficulties for installation, and so on. To solve these problems and satisfy the demand for mitigating the amplitude of pressure fluctuation simultaneously, a new runner cone with spiral grooves on the surface was developed. It was developed with unsteady draft tube calculation based on Design of Experiment (DOE) method, and the effect was confirmed by model tests. Finally, developed runner cone was installed to the prototype pump turbine, and predicted performance was confirmed by on-site tests. However, the reason why the grooved runner cone can mitigate the amplitude of pressure fluctuation in draft tube was not clarified. Therefore, numerical investigation focusing around runner cone was carried out. As a result, it was clarified that the velocity profile at runner outlet was modified by the grooved runner cone, such as, reverse flow downstream of runner cone and tangential velocity was reduced. It means the shear stress between main stream and dead water core region was weakened, therefore, it can be estimated that the amplitude of draft pressure fluctuation was reduced.
- 26 November 2012
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 15 (2) , 022019
Open AccessInvestigation of flow pattern downstream of spiral grooved runner cone in pump-turbine
High amplitude of pressure fluctuation is observed in a draft tube of a hydraulic turbine and a pump-turbine, for the case of partial load operation. Several methods had been reported to mitigate the amplitude so far, such as, air or water injection to the draft tube, fins on the draft tube surface, or runner replacement with optimized velocity profile at runner exit. However, several problems for each method can be considered, such as, negative influence on efficiency, high cost, technical difficulties for installation, and so on. To solve these problems and satisfy the demand for mitigating the amplitude of pressure fluctuation simultaneously, a new runner cone with spiral grooves on the surface was developed. It was developed with unsteady draft tube calculation based on Design of Experiment (DOE) method, and the effect was confirmed by model tests. Finally, developed runner cone was installed to the prototype pump turbine, and predicted performance was confirmed by on-site tests. However, the reason why the grooved runner cone can mitigate the amplitude of pressure fluctuation in draft tube was not clarified. Therefore, numerical investigation focusing around runner cone was carried out. As a result, it was clarified that the velocity profile at runner outlet was modified by the grooved runner cone, such as, reverse flow downstream of runner cone and tangential velocity was reduced. It means the shear stress between main stream and dead water core region was weakened, therefore, it can be estimated that the amplitude of draft pressure fluctuation was reduced.