Katarzyna Świder
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Katarzyna Świder has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Jacek Matys
Dental Surgery Department, Wroclaw Medical University, Krakowska 26, 50-425 Wroclaw, Poland
5 shared publications - Marzena Dominiak
Oral Surgery Department, Wroclaw Medical University, 50-425 Wroclaw, Poland
4 shared publications - Kinga Grzech-Leśniak
Department of Periodontics, School of Dentistry, Virginia Commonwealth University, Richmond, VA 23298, USA
2 shared publications Rafał Flieger
Private Dental Practice, Kościan, Poland
2 shared publicationsTomasz Dąbrowa
1 shared publication- Umberto Romeo
Department of Oral and Maxillofacial Sciences (SOMF), Sapienza University of Rome, 00161 Rome, Italy
1 shared publication
Latest Publications
- 27 May 2020
- Published by Termedia Sp. z.o.o. in Prosthodontics
- Vol. 70 (2) , 210-219
Allergic reactions to biomaterials utilized in prosthodontics – review of literature
- 27 May 2020
- Published by Termedia Sp. z.o.o. in Prosthodontics
- Vol. 70 (2) , 210-219
Allergic reactions to biomaterials utilized in prosthodontics – review of literature
- Open Access
- 29 June 2019
- Published by MDPI AG in Microorganisms
- Vol. 7 (7) , 189
Effect of Different Laser Wavelengths on Periodontopathogens in Peri-Implantitis: A Review of In Vivo Studies
Nowadays, many studies are examining the effectiveness of dental lasers in the treatment of peri-implantitis; however, most of them only report periodontal parameter changes. The authors of this review tried to address the question: “What is the effect of different laser wavelengths on oral bacteria that cause peri-implantitis?” An electronic search of PubMed and Cochrane Central Register of Controlled Trials was performed. The following search terms were used: (peri-implantitis OR periimplantitis) OR/AND (microbial OR microbiologic) AND (laser OR Er:YAG OR erbium OR diode OR Nd:YAG OR neodymium-doped OR Er,Cr:YSGG OR chromium-doped). Initially, 212 studies were identified. After screening the titles and abstracts and excluding studies according to predefined inclusion criteria, seven publications were included in the review. Three studies about the effect of aPDT (antimicrobial photodynamic therapy) reported a decrease in the different bacterial strains associated with peri-implantitis, e.g., A. actinomycetemcomitans, P. gingivalis, P. intermedia, T. denticola, T. forsythia, F. nucleatum, and C. rectus. Two studies showed that the high-power diode laser may have some effect on peri-implant pathogens. Two articles about the Er:YAG laser reported a lowering in the count of oral pathogens; however, it was hard to determine if this was due to the use of the laser. aPDT has the ability to decrease the count of peri-implant pathogens, whereas Er:YAG laser application shows no significant effect on oral bacteria in the long term.
- 29 June 2019
- Published by MDPI AG in Microorganisms
- Vol. 7 (7) , 189
Open AccessEffect of Different Laser Wavelengths on Periodontopathogens in Peri-Implantitis: A Review of In Vivo Studies
Nowadays, many studies are examining the effectiveness of dental lasers in the treatment of peri-implantitis; however, most of them only report periodontal parameter changes. The authors of this review tried to address the question: “What is the effect of different laser wavelengths on oral bacteria that cause peri-implantitis?” An electronic search of PubMed and Cochrane Central Register of Controlled Trials was performed. The following search terms were used: (peri-implantitis OR periimplantitis) OR/AND (microbial OR microbiologic) AND (laser OR Er:YAG OR erbium OR diode OR Nd:YAG OR neodymium-doped OR Er,Cr:YSGG OR chromium-doped). Initially, 212 studies were identified. After screening the titles and abstracts and excluding studies according to predefined inclusion criteria, seven publications were included in the review. Three studies about the effect of aPDT (antimicrobial photodynamic therapy) reported a decrease in the different bacterial strains associated with peri-implantitis, e.g., A. actinomycetemcomitans, P. gingivalis, P. intermedia, T. denticola, T. forsythia, F. nucleatum, and C. rectus. Two studies showed that the high-power diode laser may have some effect on peri-implant pathogens. Two articles about the Er:YAG laser reported a lowering in the count of oral pathogens; however, it was hard to determine if this was due to the use of the laser. aPDT has the ability to decrease the count of peri-implant pathogens, whereas Er:YAG laser application shows no significant effect on oral bacteria in the long term.
- Open Access
- 22 April 2019
- Published by Wiley in BioMed Research International
- Vol. 2019, 1-8
Photobiomodulation by a 635nm Diode Laser on Peri-Implant Bone: Primary and Secondary Stability and Bone Density Analysis—A Randomized Clinical Trial
Introduction. Various procedures in dental implantology are performed to enhance the bone healing process and implant stability. One of these methods can be a low-level laser therapy (LLLT).Objectives. The aim of our study was to evaluate the stabilization (primary and secondary) and bone density in peri-implant zone after LLLT protocol using a 635 nm diode laser.Material and Methods. The research included 40 implants placed in the posterior region of a mandible in 24 patients (8 women and 16 man; age: 46.7 ± 8.7 years). The patients were randomly divided into 2 groups G1 (n=12, 18 implants) and G2 (n=12, 22 implants) according to the treatment procedure; G1 (test): 635 nm laser, with handpiece diameter: 8mm, output power: 100mW, spot area: 0.5024cm2, average power density: 199.04mW/cm2, continuous mode, dose: 4J per point (8J/cm2), time: 40 sec per point, 2 points (irradiation on a buccal and a lingual side of the alveolus/implant), and total energy per session 8J; G2 (control): no laser irradiation. The G1 (test) group’s implants were irradiated according to the following protocol: 1 day before surgery, immediately after the surgery and 2, 4, 7, and 14 days after. The total energy after all therapeutic sessions was 48J. The implants stability was measured employing a Periotest device (Periotest Test Value: PTV) (measured immediately after the surgery, 7 days, 2 weeks, 4 weeks, and 2 and 3 months after the surgery) and the bone density using cone-beam computed tomography (grayscale value) (measured immediately after the surgery, 4 weeks and 12 weeks after the treatment).Results. The average implant stability at different time points showed lower PTV value (higher stability) atandweek after 635 nm laser irradiation (G1) compared with a control (G2) group (p0.05). The mean grayscale value at the apical, middle, and cervical level of the titanium implants showed the reduction of pixel grayscale value after 2 weeks and was lower for the G1 group in contrast to the G2 group (p<0.01). The value of grayscale after 12 weeks was significantly higher at the middle and apical level of the implants in the G1group in contrast to the G2 group (p<0.01).Conclusion. The application of the 635 nm diode laser enhanced secondary implant stability and bone density. However, to assess the impact of the LLLT on peri-implant bone with different bone densities, further well-controlled long-term trials on larger study groups are needed.- 22 April 2019
- Published by Wiley in BioMed Research International
- Vol. 2019, 1-8
Open AccessPhotobiomodulation by a 635nm Diode Laser on Peri-Implant Bone: Primary and Secondary Stability and Bone Density Analysis—A Randomized Clinical Trial
Introduction. Various procedures in dental implantology are performed to enhance the bone healing process and implant stability. One of these methods can be a low-level laser therapy (LLLT).Objectives. The aim of our study was to evaluate the stabilization (primary and secondary) and bone density in peri-implant zone after LLLT protocol using a 635 nm diode laser.Material and Methods. The research included 40 implants placed in the posterior region of a mandible in 24 patients (8 women and 16 man; age: 46.7 ± 8.7 years). The patients were randomly divided into 2 groups G1 (n=12, 18 implants) and G2 (n=12, 22 implants) according to the treatment procedure; G1 (test): 635 nm laser, with handpiece diameter: 8mm, output power: 100mW, spot area: 0.5024cm2, average power density: 199.04mW/cm2, continuous mode, dose: 4J per point (8J/cm2), time: 40 sec per point, 2 points (irradiation on a buccal and a lingual side of the alveolus/implant), and total energy per session 8J; G2 (control): no laser irradiation. The G1 (test) group’s implants were irradiated according to the following protocol: 1 day before surgery, immediately after the surgery and 2, 4, 7, and 14 days after. The total energy after all therapeutic sessions was 48J. The implants stability was measured employing a Periotest device (Periotest Test Value: PTV) (measured immediately after the surgery, 7 days, 2 weeks, 4 weeks, and 2 and 3 months after the surgery) and the bone density using cone-beam computed tomography (grayscale value) (measured immediately after the surgery, 4 weeks and 12 weeks after the treatment).Results. The average implant stability at different time points showed lower PTV value (higher stability) atandweek after 635 nm laser irradiation (G1) compared with a control (G2) group (p0.05). The mean grayscale value at the apical, middle, and cervical level of the titanium implants showed the reduction of pixel grayscale value after 2 weeks and was lower for the G1 group in contrast to the G2 group (p<0.01). The value of grayscale after 12 weeks was significantly higher at the middle and apical level of the implants in the G1group in contrast to the G2 group (p<0.01).Conclusion. The application of the 635 nm diode laser enhanced secondary implant stability and bone density. However, to assess the impact of the LLLT on peri-implant bone with different bone densities, further well-controlled long-term trials on larger study groups are needed. - Open Access
- 4 February 2019
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 56 (1) , 111-116
Er:YAG and diode laser application in implant bed preparation and implant uncovering: A case report
The use of lasers in the field of dentistry has increased recently. Their numerous advantages and applications in soft and hard tissue surgeries make them a great alternative to conservative methods in dental implantology. The most commonly used lasers are diode and erbium-doped yttrium aluminium garnet (Er:YAG) lasers. The Er:YAG laser can be used in implant bed preparation, as it brings no thermal injury to the bone. The laser does not cause bone necrosis and positively affects osseointegration and the healing process. The use of the diode laser in soft tissue surgeries helps to obtain optimal hemostasis. Therefore, it can be used in implant exposure, since it allows performing immediate impressions. The present case report describes the implementation of the Er:YAG laser in the implant bed preparation of a single-tooth dental implant in position 35 (according to the World Dental Federation (Fédération Dentaire Internationale - FDI) notation) for better bone regeneration. The implant exposure was performed with the diode 980-nm laser for hemostasis and immediate impressions. The results of laser employment were compared to traditional drilling and scalpel techniques. The advantages and disadvantages of the application of the above lasers were featured.
- 4 February 2019
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 56 (1) , 111-116
Open AccessEr:YAG and diode laser application in implant bed preparation and implant uncovering: A case report
The use of lasers in the field of dentistry has increased recently. Their numerous advantages and applications in soft and hard tissue surgeries make them a great alternative to conservative methods in dental implantology. The most commonly used lasers are diode and erbium-doped yttrium aluminium garnet (Er:YAG) lasers. The Er:YAG laser can be used in implant bed preparation, as it brings no thermal injury to the bone. The laser does not cause bone necrosis and positively affects osseointegration and the healing process. The use of the diode laser in soft tissue surgeries helps to obtain optimal hemostasis. Therefore, it can be used in implant exposure, since it allows performing immediate impressions. The present case report describes the implementation of the Er:YAG laser in the implant bed preparation of a single-tooth dental implant in position 35 (according to the World Dental Federation (Fédération Dentaire Internationale - FDI) notation) for better bone regeneration. The implant exposure was performed with the diode 980-nm laser for hemostasis and immediate impressions. The results of laser employment were compared to traditional drilling and scalpel techniques. The advantages and disadvantages of the application of the above lasers were featured.
- 1 August 2018
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 120 (2) , 177-180
Complete dentures for a patient after a stroke by means of orofacial myofunctional therapy: A clinical report
- 1 August 2018
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 120 (2) , 177-180
Complete dentures for a patient after a stroke by means of orofacial myofunctional therapy: A clinical report
- Open Access
- 31 August 2017
- Published by Wroclaw Medical University in Advances in Clinical and Experimental Medicine
- Vol. 26 (5) , 803-809
Assessment of the primary stability of root analog zirconia implants designed using cone beam computed tomography software by means of the Periotest® device: An ex vivo study. A preliminary report
The implant primary stability is a fundamental prerequisite for a success of osseointegration process which determines the prosthetic reconstruction time. The aim of the present study was to assess the quality and precision of modern conical bone computer tomography (CBCT) software in preparing root analog zirconia implants (RAZIs) by measuring its primary stability by means of the Periotest device. Thirteen pig jaws with proper erupted first premolar (P1) teeth were used in the study. The CBCT examination was conducted in the area of the P1 tooth in each mandible. The 3-dimensional (3D) view of each tooth was designed from CBCT scan. The created 3D images were used to prepare root analog zirconia implants milled from a medical-grade zirconia block by means of laboratory milling. The RAZIs and titanium implants were placed into an alveolar socket after the tooth had been removed. The primary stability of the teeth before their extraction (G1), RAZIs (G2) and titanium implants (G3) were checked by Periotest devices. The mean results in PTV were: 15.9, 3.35, 12.7 for G1, G2 and G3 group, respectively. RAZIs during immediate loading achieved a significantly higher primary stability (lower Periotest value) as compared to the teeth and implants. The modern CBCT device allows us to design a precise image of an extracted tooth for the purpose of manufacturing a root analog implant. The additional feature of the surgical protocol using RAZI is the possibility of avoiding the augmentation procedure, which reduces the whole cost of the treatment.
- 31 August 2017
- Published by Wroclaw Medical University in Advances in Clinical and Experimental Medicine
- Vol. 26 (5) , 803-809
Open AccessAssessment of the primary stability of root analog zirconia implants designed using cone beam computed tomography software by means of the Periotest® device: An ex vivo study. A preliminary report
The implant primary stability is a fundamental prerequisite for a success of osseointegration process which determines the prosthetic reconstruction time. The aim of the present study was to assess the quality and precision of modern conical bone computer tomography (CBCT) software in preparing root analog zirconia implants (RAZIs) by measuring its primary stability by means of the Periotest device. Thirteen pig jaws with proper erupted first premolar (P1) teeth were used in the study. The CBCT examination was conducted in the area of the P1 tooth in each mandible. The 3-dimensional (3D) view of each tooth was designed from CBCT scan. The created 3D images were used to prepare root analog zirconia implants milled from a medical-grade zirconia block by means of laboratory milling. The RAZIs and titanium implants were placed into an alveolar socket after the tooth had been removed. The primary stability of the teeth before their extraction (G1), RAZIs (G2) and titanium implants (G3) were checked by Periotest devices. The mean results in PTV were: 15.9, 3.35, 12.7 for G1, G2 and G3 group, respectively. RAZIs during immediate loading achieved a significantly higher primary stability (lower Periotest value) as compared to the teeth and implants. The modern CBCT device allows us to design a precise image of an extracted tooth for the purpose of manufacturing a root analog implant. The additional feature of the surgical protocol using RAZI is the possibility of avoiding the augmentation procedure, which reduces the whole cost of the treatment.
- Open Access
- 31 March 2017
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 54 (1) , 101-106
Laser instant implant impression method: A case presentation
- 31 March 2017
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 54 (1) , 101-106
Open AccessLaser instant implant impression method: A case presentation